首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The function of hemoglobin (Hb) as oxygen transporter is mediated by reversible O2 binding to Fe(2+) heme in each of the α and β subunits. X-ray crystallography revealed different subunit arrangements in oxy-Hb and deoxy-Hb. The deoxy state is stabilized by additional contacts, causing a rigidification that results in strong protection against hydrogen/deuterium exchange (HDX). Aquomet-Hb is a dysfunctional degradation product with four water-bound Fe(3+) centers. Heme release from aquomet-Hb is relatively facile, triggering oxidative damage of membrane lipids. Aquomet-Hb crystallizes in virtually the same conformation as oxy-Hb. Hence, it is commonly implied that the solution-phase properties of aquomet-Hb should resemble those of the oxy state. This work compares the structural dynamics of oxy-Hb and aquomet-Hb by HDX mass spectrometry (MS). It is found that the aquomet state exhibits a solution-phase structure that is significantly more dynamic, as manifested by elevated HDX levels. These enhanced dynamics affect the aquomet α and β subunits in a different fashion. The latter undergoes global destabilization, whereas the former shows elevated HDX levels only in the heme binding region. It is proposed that these enhanced dynamics play a role in facilitating heme release from aquomet-Hb. Our findings should be of particular interest to the MS community because oxy-Hb and aquomet-Hb serve as widely used test analytes for probing the relationship between biomolecular structure in solution and in the gas phase. We are not aware of any prior comparative HDX/MS experiments on oxy-Hb and aquomet-Hb.
Figure
?  相似文献   

2.
Information on the higher-order structure is important in the development of biopharmaceutical drugs. Recently, hydrogen/deuterium exchange coupled with mass spectrometry (HDX-MS) has been widely used as a tool to evaluate protein conformation, and unique automated systems for HDX-MS are now commercially available. To investigate the potential of this technique for the prediction of the activity of biopharmaceuticals, granulocyte colony stimulating factor (G-CSF), which had been subjected to three different stress types, was analyzed using HDX-MS and through comparison with receptor-binding activity. It was found that HDX-MS, in combination with ion mobility separation, was able to identify conformational changes in G-CSF induced by stress, and a good correlation with the receptor-binding activity was demonstrated, which cannot be completely determined by conventional peptide mapping alone. The direct evaluation of biological activity using bioassay is absolutely imperative in biopharmaceutical development, but HDX-MS can provide the alternative information in a short time on the extent and location of the structural damage caused by stresses. Furthermore, the present study suggests the possibility of this system being a versatile evaluation method for the preservation stability of biopharmaceuticals. Graphical Abstract
?  相似文献   

3.
4.
蛋白质是生命功能的执行者,其功能的发挥受自身结构动态变化、与其他生物分子的相互作用及修饰等因素的调节。因此,对蛋白质及蛋白复合物结构的研究有助于揭示重要生命过程中的分子机理与机制。氢氘交换质谱(Hydrogen deuterium exchange mass spectrometry,HDX-MS)是研究蛋白质结构、动态变化和相互作用的强有力工具,也是传统生物物理手段的重要补充。该文综述了HDX-MS的基本原理、机制、实验方法和研究最新进展,并从蛋白质自身动态变化、蛋白质-小分子相互作用、蛋白质-蛋白质相互作用3个方面介绍了近年来HDX-MS在蛋白及蛋白复合物研究中的应用进展。  相似文献   

5.
When highly concentrated, an antibody solution can exhibit unusual behaviors, which can lead to unwanted properties, such as increased levels of protein aggregation and unusually high viscosity. Molecular modeling, along with many indirect biophysical measurements, has suggested that the cause for these phenomena can be due to short range electrostatic and/or hydrophobic protein–protein interactions. Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a useful tool for investigating protein conformation, dynamics, and interactions. However, “traditional” continuous dilution labeling HDX-MS experiments have limited utility for the direct analysis of solutions with high concentrations of protein. Here, we present a dialysis-based HDX-MS (di-HDX-MS) method as an alternative HDX-MS labeling format, which takes advantage of passive dialysis rather than the classic dilution workflow. We applied this approach to a highly concentrated antibody solution without dilution or significant sample manipulation, prior to analysis. Such a method could pave the way for a deeper understanding of the unusual behavior of proteins at high concentrations, which is highly relevant for development of biopharmaceuticals in industry.
Graphical Abstract ?
  相似文献   

6.
Management of the enormous amount of data produced during solution-phase hydrogen/deuterium exchange monitored by mass spectrometry has stimulated software analysis development. The proteolysis step of the experiment generates multiple peptide fragments, most of which overlap. Prior automated data reduction algorithms extract the deuteration level for individual peptides, but do not exploit the additional information arising from fragment overlap. Here, we describe an algorithm that determines discrete rate constant values to each of the amide hydrogens in overlapped fragments. By considering all of the overlapped peptide segments simultaneously, sequence resolution can be improved significantly, sometimes to the individual amino acid level. We have validated the method with simulated deuterium uptake data for seven overlapped fragments of a poly-Ala nonapeptide, and then applied it to extract rate constant values for the first 29?N-terminal amino acids of C22A FK506-binding protein.  相似文献   

7.
Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a well established method for the measurement of solution-phase deuterium incorporation into proteins, which can provide insight into protein conformational mobility. However, most HDX measurements are constrained to regions of the protein where pepsin proteolysis allows detection at peptide resolution. Recently, single-amide resolution deuterium incorporation has been achieved by limiting gas-phase scrambling in the mass spectrometer. This was accomplished by employing a combination of soft ionization and desolvation conditions coupled with the radical-driven fragmentation technique electron transfer dissociation (ETD). Here, a hybrid LTQ-Orbitrap XL is systematically evaluated for its utility in providing single-amide deuterium incorporation for differential HDX analysis of a nuclear receptor upon binding small molecule ligands. We are able to show that instrumental parameters can be optimized to minimize scrambling and can be incorporated into an established and fully automated HDX platform making differential single-amide HDX possible for bottom-up analysis of complex systems. We have applied this system to determine differential single amide resolution HDX data for the peroxizome proliferator activated receptor bound with two ligands of interest.  相似文献   

8.
Noisy and overlapped mass spectrometry data hinder the sequence coverage that can be obtained from hydrogen deuterium exchange analysis, and places a limit on the complexity of the samples that can be studied by this technique. Advances in instrumentation have addressed these limits, but as the complexity of the biological samples under investigation increases, these problems are re-encountered. Here we describe the use of binomial distribution fitting with asymmetric linear squares regression for calculating the accurate deuterium content for mass envelopes of low signal or that contain significant overlap. The approach is demonstrated with a test data set of HIV Env gp140 wherein inclusion of the new analysis regime resulted in obtaining exchange data for 42 additional peptides, improving the sequence coverage by 11 %. At the same time, the precision of deuterium uptake measurements was improved for nearly every peptide examined. The improved processing algorithms also provide an efficient method for deconvolution of bimodal mass envelopes and EX1 kinetic signatures. All these functions and visualization tools have been implemented in the new version of the freely available software, HX-Express v2.
Figure
?  相似文献   

9.
Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein–protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.  相似文献   

10.
PEGylation is the covalent attachment of polyethylene glycol to proteins, and it can be used to alter immunogenicity, circulating half life and other properties of therapeutic proteins. To determine the impact of PEGylation on protein conformation, we applied hydrogen/deuterium exchange mass spectrometry (HDX MS) to analyze granulocyte colony stimulating factor (G-CSF) upon PEGylation as a model system. The combined use of HDX automation technology and data analysis software allowed reproducible and robust measurements of the deuterium incorporation levels for peptic peptides of both PEGylated and non-PEGylated G-CSF. The results indicated that significant differences in deuterium incorporation were induced by PEGylation of G-CSF, although the overall changes observed were quite small. PEGylation did not result in gross conformational rearrangement of G-CSF. The data complexity often encountered in HDX MS measurements was greatly reduced through a data processing and presentation format designed to facilitate the comparison process. This study demonstrates the practical utility of HDX MS for comparability studies, process monitoring, and protein therapeutic characterization in the biopharmaceutical industry.  相似文献   

11.
Ion mobility spectrometry-mass spectrometry (IMS-MS) in combination with gas-phase hydrogen/deuterium exchange (HDX) and collision-induced dissociation (CID) is evaluated as an analytical method for small-molecule standard and mixture characterization. Experiments show that compound ions exhibit unique HDX reactivities that can be used to distinguish different species. Additionally, it is shown that gas-phase HDX kinetics can be exploited to provide even further distinguishing capabilities by using different partial pressures of reagent gas. The relative HDX reactivity of a wide variety of molecules is discussed in light of the various molecular structures. Additionally, hydrogen accessibility scoring (HAS) and HDX kinetics modeling of candidate (in silico) ion structures is utilized to estimate the relative ion conformer populations giving rise to specific HDX behavior. These data interpretation methods are discussed with a focus on developing predictive tools for HDX behavior. Finally, an example is provided in which ion mobility information is supplemented with HDX reactivity data to aid identification efforts of compounds in a metabolite extract.
Graphical Abstract ?
  相似文献   

12.
In this study, the effects of lead ions(Pb2+) on the conformations of leucine encephalin(LE) and methionine encephalin(ME) in gas phase were studied using hydrogen/deuterium exchange mass spectrometry(HDX-MS) and quantum chemistry theoretical calculations at the molecular level. The HDX-MS result revealed that the complexes with the monovalent compounds [LE+Pb–H]+ and [ME+Pb–H]+had a 1:1 stoichiometric ratio, and different HDX reactivates were observed in a follow of [ME+H]+>[LE+H]+>[LE+Pb–H]+> [ME+Pb–H]+. Combining the collision-induced dissociation energies of the complexes and their HDX results, it was found that the more stable the complex, the harder it was for HDX. In addition, the favo-rable conformations of the complexes were obtained by theoretical calculations, revealing that the similar coordination type with diffe-rent bond lengths was obtained. Then, the proton affinity(PA) values of the optimized complexes were calculated to interpret the HDX observations, indicating that the higher the PA values, the more difficult it was for HDX. Overall, the experiments and theoretical calculations revealed that Pb2+ could induce conformational changes of LE and ME, and generate ME into a more rigid conformation than LE. The results will prompt further fundamental investigations on the conformational properties of LE/ME in coordination with Pb2+.  相似文献   

13.
Gas-phase hydrogen deuterium exchange (HDX), collision cross section (CCS) measurement, and molecular dynamics simulation (MDS) techniques were utilized to develop and compare three methods for estimating the relative surface area exposure of separate peptide chains within bovine insulin ions. Electrosprayed [M – 3H]3? and [M – 5H]5? insulin ions produced a single conformer type with respective collision cross sections of 528 ± 5 Å2 and 808 ± 2 Å2. [M – 4H]4? ions were comprised of more compact (Ω = 676 ± 3 Å2) and diffuse (i.e., more elongated, Ω = 779 ± 3 Å2) ion conformer types. Ions were subjected to HDX in the drift tube using D2O as the reagent gas. Collision-induced dissociation was used to fragment mobility-selected, isotopically labeled [M – 4H]4? and [M – 5H]5? ions into the protein subchains. Deuterium uptake levels of each chain can be explained by limited inter-chain isotopic scrambling upon collisional activation. Using nominal ion structures from MDS and a hydrogen accessibility model, the deuterium uptake for each chain was correlated to its exposed surface area. In separate experiments, the per-residue deuterium content for the protonated and deprotonated ions of the synthetic peptide KKDDDDDIIKIIK were compared. The differences in deuterium content indicated the regional HDX accessibility for cations versus anions. Using ions of similar conformational type, this comparison highlights the complementary nature of HDX data obtained from positive- and negative-ion analysis.
Graphical Abstract ?
  相似文献   

14.
15.
Top down mass spectrometry, using a Fourier transform instrument, has unique capabilities for biomolecule kinetic studies, in that the concentration of large molecules in a reaction mixture can be monitored simultaneously from its mass spectrum produced by electrospray ionization. This is demonstrated with enzyme modifications occurring in the biosynthesis of the thiazole moiety of thiamin phosphate. The formation rate of ThiS-thiocarboxylate from ThiS was determined from the relative abundance of the corresponding m/z 10162 and 10146 isotopic peak clusters for all the observable charge states in the mass spectra measured at different reaction times. Even without measuring standard ionization efficiencies, the rate and precision of 0.018 +/- 0.004 min(-1) agree well with the 0.027 +/- 0.003 min(-1) obtained with a radiochemical assay, which requires a separate derivatization step. To illustrate the simultaneous characterization of the reaction kinetics of a native enzyme and its mutant, the imine formation rate of ThiG and its substrate DXP was compared between the native protein (M(r) = 26803.9) and its E98A (M(r) = 26745.9) or D182A (M(r) = 26759.9) mutant in the same reaction mixture. The kinetic data show clearly that neither the E98 nor the D182 residues participate in the imine formation. The high resolution and MS/MS capabilities of FTMS should make possible the extension of this kinetics approach to far more complicated systems, such as simultaneous monitoring of 24 native, intermediate, and reduced forms in the reductive unfolding of a mixture of ribonuclease A and the five isoforms of ribonuclease B. Stable intermediates with different SS bonding (same molecular weight) can be differentiated by MS/MS, while molecular ions differing by only 2 Da are distinguished clearly by synthesizing isotopically depleted proteins.  相似文献   

16.
Neurodegenerative disorders are characterized by the formation of protein oligomers and amyloid fibrils, which in the case of Parkinson’s disease involves the protein α‐synuclein (αSN). Cytotoxicity is mainly associated with the oligomeric species, but we still know little about their assembly and structure. Hydrogen/deuterium exchange (HDX) monitored by mass spectrometry is used to analyze oligomers formed by wild‐type (wt) αSN and also three familial αSN mutants (A30P, E46K, and A53T). All four variants show co‐existence of two different oligomers. The backbone amides of oligomer type I are protected from exchange with D2O until they dissociate into monomeric αSN by EX1 exchange kinetics. Fewer residues are protected against exchange in oligomer type II, but this type does not revert to αSN monomers. Both oligomers are protected in the core sequence Y39–A89. Based on incubation studies, oligomer type I appears to form straight fibrils, while oligomer type II forms amorphous clusters that do not directly contribute to the fibrillation process.  相似文献   

17.
AMP-activated protein kinase (AMPK) is a serine/threonine protein kinase that is essential in regulating energy metabolism in all eukaryotic cells. It is a heterotrimeric protein complex composed of a catalytic subunit (α) and two regulatory subunits (β and γ). C-terminal truncation of AMPKα at residue 312 yielded a protein that is active upon phosphorylation of Thr172 in the absence of β and γ subunits, which is refered to as the AMPK catalytic domain and commonly used to substitute for the AMPK heterotrimeric complex in in vitro kinase assays. However, a comprehensive characterization of the AMPK catalytic domain is lacking. Herein, we expressed a His-tagged human AMPK catalytic domin (denoted as AMPKΔ) in E. coli, comprehensively characterized AMPKΔ in its basal state and after in vitro phosphorylation using top-down mass spectrometry (MS), and assessed how phosphorylation of AMPKΔ affects its activity. Unexpectedly, we found that bacterially-expressed AMPKΔ was basally phosphorylated and localized the phosphorylation site to the His-tag. We found that AMPKΔ had noticeable basal activity and was capable of phosphorylating itself and its substrates without activating phosphorylation at Thr172. Moreover, our data suggested that Thr172 is the only site phosphorylated by its upstream kinase, liver kinase B1, and that this phosphorylation dramatically increases the kinase activity of AMPKΔ. Importantly, we demonstrated that top-down MS in conjunction with in vitro phosphorylation assay is a powerful approach for monitoring phosphorylation reaction and determining sequential order of phosphorylation events in kinase-substrate systems.
Graphical Abstract ?
  相似文献   

18.
小鼠髓系白血病M1细胞经IL-6诱导分化后一系列蛋白质点的表达量发生了变化,其中A点表达量显著增加。MALDI-TOF-MS的肽质量指纹谱鉴定表明A点为肿瘤蛋白D52(tumor protein D52,TP D52)。为进一步确认该结果,对A点进行了ESI-MS/MS分析,测定了3个肽段的序列。Mascot数据库查询结果很肯定地表明该蛋白为TP D52,但只有两个肽段与之匹配。对未匹配肽段的序列分析表明它对应于TP D52N端1-10氨基酸MDRGEQGLLK,其中N端第1个氨基酸甲硫氨酸M发生了乙酰化。分析结果与M乙酰化的规律一致,即当第2个氨基酸是酸性氨基酸D或E时,M很容易发生乙酰化。本研究文首次报道了TP D52的N端乙酰化,其功能需要进一步研究。  相似文献   

19.
20.
Measurement of the naturally occurring hydrogen exchange (HX) behavior of proteins can in principle provide highly resolved thermodynamic and kinetic information on protein structure, dynamics, and interactions. The HX fragment separation-mass spectrometry method (HX-MS) is able to measure hydrogen exchange in biologically important protein systems that are not accessible to NMR methods. In order to achieve high structural resolution in HX-MS experiments, it will be necessary to obtain many sequentially overlapping peptide fragments and be able to identify and analyze them efficiently and accurately by mass spectrometry. This paper describes operations which, when applied to four different proteins ranging in size from 140 to 908 residues, routinely provides hundreds of useful unique peptides, covering the entire protein length many times over. Coverage in terms of the average number of peptide fragments that span each amino acid exceeds 10. The ability to achieve these results required the integrated application of experimental methods that are described here and a computer analysis program, called ExMS, described in a following paper.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号