首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
CoO(100)表面高分辩电子能损失谱与量子化学的从头算石守衡(大连轻工业学院基础部物理化学教研室,大连,116034)关键词CoO(100)表面,高分辩电子能损失谱,从头算A.Freitag等[1]用高辩电子能损失谱研究了NiO(100)表面的电子...  相似文献   

2.
Metabolomics experiments require chemical identifications, often through MS/MS analysis. In mass spectrometry imaging (MSI), this necessitates running several serial tissue sections or using a multiplex data acquisition method. We have previously developed a multiplex MSI method to obtain MS and MS/MS data in a single experiment to acquire more chemical information in less data acquisition time. In this method, each raster step is composed of several spiral steps and each spiral step is used for a separate scan event (e.g., MS or MS/MS). One main limitation of this method is the loss of spatial resolution as the number of spiral steps increases, limiting its applicability for high-spatial resolution MSI. In this work, we demonstrate multiplex MS imaging is possible without sacrificing spatial resolution by the use of overlapping spiral steps, instead of spatially separated spiral steps as used in the previous work. Significant amounts of matrix and analytes are still left after multiple spectral acquisitions, especially with nanoparticle matrices, so that high quality MS and MS/MS data can be obtained on virtually the same tissue spot. This method was then applied to visualize metabolites and acquire their MS/MS spectra in maize leaf cross-sections at 10 μm spatial resolution.
Graphical Abstract ?
  相似文献   

3.
We have investigated the use of a Gaussian beam laser for MALDI Imaging Mass Spectrometry to provide a precisely defined laser spot of 5 μm diameter on target using a commercial MALDI TOF instrument originally designed to produce a 20 μm diameter laser beam spot at its smallest setting. A Gaussian beam laser was installed in the instrument in combination with an aspheric focusing lens. This ion source produced sharp ion images at 5 μm spatial resolution with signals of high intensity as shown for images from thin tissue sections of mouse brain.
Figure
?  相似文献   

4.
胡建芳  彭平安 《分析化学》2000,10(3):283-287
研究全球变化的手段多种多样,高分辨分子地层学是最有力的工具之一,进行此项研究工作要分析的样品大且溶量小,因此建立一种合适的有机质分离及定量方法十分重要。本文采用冷抽提法的方法抽提出这类样品的有机质,衍生化合利用GC/MS对化合物进行定性、定量分析。利用本方法分析的空白加标(地质体中最常见化合物)回收率结果为:烷烃95.8%,脂肪酸92.3%,胆甾醇99.7%;脂肪醇93.7%;基质加标加收率结果为  相似文献   

5.
We describe a systematic comparison of high and low resolution LC-MS/MS assays for quantification of 25-hydroxyvitamin D3 in human serum. Identical sample preparation, chromatography separations, electrospray ionization sources, precursor ion selection, and ion activation were used; the two assays differed only in the implemented final mass analyzer stage; viz. high resolution quadrupole-quadrupole-time-of-flight (QqTOF) versus low resolution triple quadrupole instruments. The results were assessed against measured concentration levels from a routine clinical chemiluminescence immunoassay. Isobaric interferences prevented the simple use of TOF-MS spectra for extraction of accurate masses and necessitated the application of collision-induced dissociation on the QqTOF platform. The two mass spectrometry assays provided very similar analytical figures of merit, reflecting the lack of relevant isobaric interferences in the MS/MS domain, and were successfully applied to determine the levels of 25-hydroxyvitamin D for patients with chronic liver disease.
Graphical Abstract ?
  相似文献   

6.
High‐field dynamic nuclear polarization (DNP) has emerged as a powerful technique for improving the sensitivity of solid‐state NMR (SSNMR), yielding significant sensitivity enhancements for a variety of samples, including polymers. Overall, depending upon the type of polymer, the molecular weight, and the DNP sample preparation method, sensitivity enhancements between 5 and 40 have been reported. These promising enhancements remain, however, far from the theoretical maximum (>1000). Crucial to the success of DNP SSNMR is the DNP signal enhancement (εDNP), which is the ratio of the NMR signal intensities with and without DNP. It is shown here that, for polymers exhibiting high affinity toward molecular oxygen (e.g., polystyrene), removing part of the absorbed (paramagnetic) oxygen from the solid‐state samples available as powders (instead of dissolved or dispersed in a solvent) increases proton nuclear relaxation times and εDNP, hereby providing up to a two‐fold sensitivity increase (i.e., a four‐fold reduction in experimental time).

  相似文献   


7.
Secondary organic aerosol (SOA) is formed when organic molecules react with oxidants in the gas phase to form particulate matter. Recent measurements have shown that more than half of the mass of laboratory-generated SOA consists of high molecular weight oligomeric compounds. In this work, the formation mechanisms of oligomers produced in the laboratory by ozonolysis of α-pinene, an important SOA precursor in ambient air, are studied by MS and MS/MS measurements with high accuracy and resolving power to characterize monomer building blocks and the reactions that couple them together. The distribution of oligomers in an SOA sample is complex, typically yielding over 1000 elemental formulas that can be assigned from an electrospray ionization mass spectrum. Despite this complexity, MS/MS spectra can be found that give strong evidence for specific oligomer formation pathways that have been postulated but not confirmed. These include aldol and gem-diol reactions of carbonyls as well as peroxyhemiacetal formation from hydroperoxides. The strongest evidence for carbonyl reactions is in the formation of hydrated products. Less compelling evidence is found for dehydrated products and secondary ozonide formation. The number of times that a monomer building block is observed as a fragmentation product in the MS/MS spectra is shown to be independent of the monomer vapor pressure, suggesting that oligomer formation is not driven by equilibrium partitioning of a monomer between the gas and particle phases, but rather by reactive uptake where a monomer collides with the particle surface and rapidly forms an oligomer.  相似文献   

8.
A novel specimen preparation method has been devised utilizing an Ar ion beam with a masking plate and an apparatus for this method has been developed for the preparation of good quality cross sections for high spatial resolution microscopy and microanalysis. This apparatus is defined as a Cross-section Polisher. The method overcomes most of the drawbacks inherent in the traditional method of mechanical grinding and polishing and enabled us to prepare good quality cross sections with much larger areas than those prepared by a focused ion beam method, essentially retaining the excellent characteristics of the latter method. Microstructural observations of corrosion morphology and chemical analysis of corrosion products in a corrosion-resistant alloy (Alloy 825) with a thermal field emission type electron probe X-ray microanalyzer are reported to show the power of the Cross-section Polisher.  相似文献   

9.
土壤中二(噁)英的分析检测包括样品预处理和仪器分析两部分,预处理主要包括提取、净化两个过程,通常预处理占整个分析工作时间的70%~80%,且预处理的质量直接影响最后的检测结果.  相似文献   

10.
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.  相似文献   

11.
张建清  钟伟祥  单慧媚 《分析化学》2002,30(12):1481-1485
采用高分辨气相色谱 高分辨双聚焦磁式质谱联用仪 (HRGC HRMS)定量检测了市售猪肉中 1 7个 4~ 8个氯原子取代的二英和呋喃 (PCDDs Fs)。样品中的二英经过索式抽提、浓缩、碳柱富集、色谱柱纯化和分离 ,以HRGC HRMS 多离子检测方式对样品中的PCDDs Fs进行定性分析 ,同位素稀释技术定量 ,该方法定量可精确到pg g水平。结果表明 :该方法的检出限TCDF和TCDD均为 0 0 1pg g。同位素标准物的回收率分布于 68.6%~ 92 .4 %之间。样品中 1 7个同系物异构体以OCDD的含量为最高 ,为 0 .65 3pg g,OCDF为0 1 2 6pg g,其它均未检出。采用WHO的毒性等量因子 (TEF)计算样品的PCDDs Fs浓度为 0 .0 0 0 1pgTEQ g。该方法定性、定量准确 ,为目前国际上权威认可的二英定量检测方法  相似文献   

12.
Celosin A (CA), a natural compound isolated from Celosia argentea L., has been shown significant hepatoprotective effect on AHNP‐induced liver injury. This study described a rapid and sensitive ultra‐high‐pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) assay for determination of CA in rat plasma. Methanol‐mediated precipitation was used for sample pretreatment. Chromatographic separation was achieved on a T3 column with gradient elution using water and acetonitrile as mobile phase. Determination was obtained using an electrospray ionization source in negative selected reaction monitoring mode at the transitions of m/z 793.3 → m/z 661.2 and m/z 955.6 → m/z 793.2 for CA and IS, respectively. The assay was linear over the concentration range 0.25–2500 ng/mL (r > 0.995) with a lowest limit of quantification (LLOQ) of 0.25 ng/mL. The intra‐ and inter‐day precisions (RSD) were 1.65–9.84 and 2.46–13.49%, respectively, while accuracy (RR) ranged from 96.21 to 99.45%, respectively. The recovery ranged from 95.09 to 102.22% and the matrix effect from 98.29 to 100.13%. The analyte was stable under the tested storage conditions. The method has been successfully applied to a preclinical pharmacokinetic study in rats after a single intravenous (2 mg/kg) or oral (50 mg/kg) administration. The oral bioavailability of CA was ~1.94%; in addition, there was no difference between male and female rats. This is the first time of the use of an UHPLC–MS/MS method for determination of CA concentration in rat plasma and for evaluation of its pharmacokinetic behavior.  相似文献   

13.
14.
A variable flow "peak trapping" liquid chromatography (LC) interface has been developed for the coupling of nanoscale LC to electrospray ionization mass spectrometry (ESI-MS). The presented peak trapping LC interface allows for the extended analysis time of co-eluting compounds and has been employed for the identification of proteins via tandem mass spectrometry (MS/MS). The variable flow process can be controlled either manually or in a completely automated manner where the mass spectrometer status determines the status of the variable flow interface. When the mass spectrometer operates in MS survey mode, the interface is operated in a so-called "high-flow" mode. Alternatively, the interface is operated in a "low-flow" mode during MS/MS analysis. In the "high-flow" mode of the variable flow process the column flow rate is typically around 200 nL/min, whereas in the "low-flow" mode the column effluent is introduced into the source of the mass spectrometer at 25 nL/min. In addition to the flow reduction during MS/MS analysis, the gradient is paused to preserve the peptide separation on the analytical nanoscale LC column. The performance of the variable flow nanoscale LC/MS/MS interface is demonstrated by the automated analysis of standard peptide mixtures and protein digests utilizing variable flow, data-dependent scanning MS/MS techniques, and automated database searching.  相似文献   

15.
Electrochemistry combined with mass spectrometry represents an emerging analytical technique used to study the oxidation pathway of various drugs and in vivo occurring compounds, continuously showing a capability to generate many known metabolites or new oxidation products. An on‐line HPLC/EC/HR ESI‐MS method had been used to investigate the oxidation of selected cytokinin compounds. This setup allowed rapid identification and general structure elucidation of the obtained products. An electrochemical oxidation of isopentenyladenine resulted in five products, including hydroxylated and dehydrogenated products, which correlates very well with its in vivo metabolism. Electrochemical conversion of trans‐zeatin revealed six products, with two dehydrogenation products corresponding to its in vivo occurring metabolites. cis‐Zeatin oxidation in the electrochemical cell gave rise to eight products, resembling similarity to trans‐zeatin oxidation. All three compounds underwent a complete turnover mainly through two oxidation reactions occurring in the electrochemical cell? dehydrogenation and a less typical aliphatic hydroxylation. The resulting products are in correlation with their known in vivo metabolism.  相似文献   

16.
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.  相似文献   

17.
An HPLC/MS/MS method has been developed and validated for the quantification and confirmation of nicarbazin and ionophores (lasalocid, monensin, salinomycin, and narasin) in eggs. Nicarbazin is determined in the negative electrospray mode with a basic mobile phase that supports creation of negative ions. Consequently, our ability to maintain instrument sensitivity over time has significantly improved. The analysis of the ionophores is done in the positive electrospray mode using ammonium buffer for HPLC separation. Monitoring ammonium adduct parent ions resulted in enhanced sensitivity and better reproducibility of the ionophore analysis. The validation of this improved HPLC/MS/MS method for the detection of nicarbazin and the ionophores demonstrated excellent precision of below 10% RSD and lower LOD values (microg/kg) for nicarbazin (0.018), lasalocid (0.015), monensin (0.015), salinomycin (0.033), and narasin (0.039).  相似文献   

18.
Accurate measurement of low levels of testosterone is critical for diagnosis and treatment of androgen disorders. The very low concentrations of testosterone in children, females, and males with androgen suppression therapies necessitate the use of mass spectrometry‐based methods. We aimed to develop a liquid chromatography with tandem mass spectrometry method with simplified sample preparation and online solid‐phase extraction cleanup to achieve enhanced precision, accuracy, robustness, and cost‐effectiveness. The assay was linear from 10 to 20 000 pg/mL with an analytical recovery of 93–104%. The total coefficient of variation was 2.5, 1.9, and 1.7% at concentration levels of 348, 5432, and 10 848 pg/mL, respectively. No significant carryover was observed from samples with concentrations up to 20 000 pg/mL. No significant interference was observed from androstenedione, dehydroepiandrosterone, epi‐testosterone, and estriol. Comparison with CDC Hormone Standardization program (HoSt) reference samples with defined values (n = 40) showed a Deming regression slope of 0.963, intercept of 28.06 pg/mL, standard error of estimate was 66.9, a correlation coefficient of 0.9996, and a mean bias of ?0.6%. The method met the accuracy criteria by the CDC HoSt program. In addition, we achieved >12 000 injections on a single analytical column without significant performance deterioration due to the specific online solid‐phase extraction settings.  相似文献   

19.
Abstract

Methods have been developed for the quantification of low-microgram levels of the extractable organic matter contained in the atmospheric fine aerosol fraction. Extract quantification is accomplished by computer-assisted high-resolution gas chromatography (HRGC) used in conjunction with a procedural recovery mixture containing perdeuterated compounds of differing polarity and molecular weight. Recovery data for these species indicate that relative volatility rather than functional group classification is the primary factor affecting overall recovery. Routine quality control analysis is performed on a per-sample basis by high-resolution gas chromatography/mass spectrometry (HRGC/MS) for confirmation of the standard components and for identification of procedural contaminants. By the way of illustration, fine aerosol samples have been analyzed from Anaheim. California. The absolute solvent extract yields range from 49 to 346μg of organic carbon, and demonstrate a seasonal variation with winter maximum and summer minimum concentrations.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号