首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the determination of Se in pharmaceutical samples (nutritional supplements and shampoos) is proposed. The method involves two steps: (1) digestion of the samples and reduction of all forms of Se to Se(IV), which is complete in only 10 min by the use of a focused microwave digestor; and (2) continuous derivatisation (hydride formation) and spectrometry detection by atomic fluorescence. The method can be applied over a wide range of concentrations (0.3-1300 ng ml(-1) of Se) with good repeatability (RSD values lower than 4.6%). The method has been applied successfully to a reference material, and two different types of pharmaceuticals (namely, five different nutritional supplements-with Se present as sodium selenite and Se-methionine-and two shampoos, with selenium sulphide), in agreements with the certified and nominal values, respectively. Yields ranged between 86.5 and 104.8%, and good precision (RSD values lower than 4.2%) were obtained in all instances.  相似文献   

2.
通过对比电感耦合等离子体发射光谱法(ICP-OES)与石墨炉原子吸收法(AAS)测定水中重金属的检出限、重复性、加标回收率等实验,验证两种方法的准确性,从而为饮用水中重金属的测定提供可靠的方法。结果表明,石墨炉原子吸收法测定饮用水中砷、镉、铬、铅、汞、硒检出限均低于ICP-OES法,但ICP-OES法测定线性范围宽,重复性和加标回收率均优于石墨炉原子吸收法,分析速度快,操作便捷,结果满意,是目前饮用水中重金属的测定非常可靠的方法。  相似文献   

3.
通过对比电感耦合等离子体原子发射光谱法(ICP-OES)与石墨炉原子吸收光谱法(AAS)测定水中重金属的检出限、重复性、加标回收率等实验,验证两种方法的准确性,从而为饮用水中重金属的测定提供可靠的方法。结果表明,石墨炉原子吸收光谱法测定饮用水中砷、镉、铬、铅、汞、硒的检出限均低于ICP-OES法,但ICP-OES法测定线性范围宽,重复性和加标回收率均优于石墨炉原子吸收光谱法,分析速度快,操作便捷,结果满意,是目前饮用水中重金属测定非常可靠的方法。  相似文献   

4.
Membrane-assisted solvent extraction (MASE) was applied for the determination of seven phenols (phenol, 2-chlorophenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 4-chloro-3-methylphenol, 2,4,6-trichlorophenol and pentachlorophenol) with log Kow (octanol-water-partition-coefficient) between 1.46 (phenol) and 5.12 (pentachlorophenol) in water. The extraction solvents cyclohexane, ethyl acetate and chloroform were tested and ethyl acetate proved to be the best choice. The optimisation of extraction conditions showed the necessity of adding 5 g of sodium chloride to each aqueous sample to give a saturated solution (333 g/L). The pH-value of the sample was adjusted to 2 in order to convert all compounds into their neutral form. An extraction time of 60 min was found to be optimal. Under these conditions the recovery of phenol, the most polar compound, was 11%. The recoveries of the other analytes ranged between 42% (2-chlorophenol) and 98% (2,4-dichlorophenol). Calibration was performed using large volume injection (100 microL injection volume). At optimised conditions the limits of detection were between 0.01 and 0.6 microg/L and the relative standard deviation (n = 3) was on average about 10%. After the method optimisation with reagent water membrane-assisted solvent extraction was applied to two contaminated ground water samples from the region of Bitterfeld in Saxony-Anhalt, Germany. The results demonstrate the good applicability of membrane-assisted solvent extraction for polar analytes like phenols, without the necessity of derivatisation or a difficult and time-consuming sample preparation.  相似文献   

5.
The present paper describes radiochemical separation procedures developed for the determination of seven elements: As, Cd, Cr, Cu, Hg, Sb and Se in different Brazilian regional diets. In the case of the elements As, Hg, Sb and Se, the procedure was based on retention in inorganic exchanger TDO (tin dioxide) and determination of Hg by extraction with Ni(DDC)2. For determination of Cd, Cr, Cu and Se the procedure chosen was based on retention in inorganic exchanger HMD (hydrated managese dioxide) and extraction of Cu and Cd as diethyldithiocarbamate compounds. The accuracy and precision of the methods studied were tested by means of analyses of different reference materials. Due to the lack of data on trace element levels in Brazilian foodstuffs and diets, these methods were applied to determination of these elements in different Brazilian regional diets. These diets were supplied by the Food and Experimental Nutrition Department of the Faculty of Pharmaceutical Science, University of São Paulo. The daily dietary intake values for these diets are presented for As, Cd, Cr, Cu, Hg, Sb and Se.  相似文献   

6.
A novel analytical method is reported that combines continuous solid-phase extraction and gas chromatography for the determination of 22 carboxylic acids in water. The highly polar and hydrophilic analytes were preferentially sorbed on a mixture of LiChrolut EN-Supelclean ENVI-18 (1:1) sorbent column and eluted with methanol; this extraction process did not require derivatisation. The extract was analysed by gas chromatography coupled to a flame ionisation detector as well as a mass spectrometer with electron impact (EI) or positive chemical ionisation modes. The highest sensitivity was achieved when using MS-EI, with good linearity in calibration curves and low detection limits (2-40ngL(-1)) for 50mL of sample. The entire procedure from raw aqueous sample to a ready-to-inject methanol solution of the acids requires less than 15min. Another benefit of this method is the good accuracy (recoveries between 93 and 102%) and precision (relative standard deviation, 3.4-6.2%), which allows the determination of carboxylic acids in environmental water and in real chlorinated and ozonated drinking water.  相似文献   

7.
Procedures for the isolation of poly(propylene glycol)s (PPGs) from a water matrix have been developed. Solid-phase extraction with an octadecylsilica cartridge and elution with methanol or with a graphitised carbon black cartridge and elution with a mixture of dichloromethane-methanol (4:1) or liquid-liquid extraction with chloroform were all suitable for model samples. However, only liquid-liquid extraction was suitable both for model and real environmental samples. Methods for reversed-phase liquid chromatographic determination of PPGs based on derivatisation and ultraviolet or fluorescence detection have been developed. Four derivatisation agents [3,5-dinitrobenzoyl chloride, phenyl isocyanate, 1-naphthoyl chloride and 1-naphthyl isocyanate (NIC)] were tested. Only NIC was found to give good reproducibility as well as a satisfactory detection limit. Finally, a method with liquid-liquid extraction with chloroform, derivatisation with NIC and liquid chromatographic separation with fluorescence detection was established. The developed method shows a highly correlated linearity of the analytical signals of particular homologues within a wide concentration range (approximately from 0.01 to 10 mg l(-1)). The precision of measurements is satisfactory for homologues having 5-9 oxypropylene subunits and becomes worse with an increase in the number of oxypropylene subunits. The limit of detection is 2 microg l(-1) for the majority of homologues. The method is suitable for the isolation and quantitative determination of PPGs in river water samples and as a tool for biodegradation testing.  相似文献   

8.
Continuous ultrasound-assisted extraction of nitropolycyclic aromatic hydrocarbons from soil prior to their individual separation and determination by gas chromatography (GC) with MS-MS detection is presented here. A multivariate optimisation of the variables affecting the continuous extraction step (namely, probe position, ultrasound radiation amplitude, percentage of duty cycle of ultrasonic exposure, sonication time, total extractant volume, extractant flow rate and temperature of the water-bath in which the extraction cell was placed) was performed. The method was compared with the reference EPA method 3540 using natural contaminated soils. Similar efficiencies were obtained but with a drastic reduction of both the extraction time (10 min versus 24 h) and the extractant volume (less than 10 ml versus 100 ml) by the proposed method. Detection limits of low picogram were obtained, with repeatability and reproducibility between 4.21-5.70 and 5.20-7.23%, respectively.  相似文献   

9.
植物样品中各元素的含量,是评价土壤质量及健康的重要指标。为满足测定大批量生态地球化学植物样品中多金属元素分析要求,建立了交互模式-电感耦合等离子体质谱(ICP-MS)法测定植物样品中7种痕量金属元素的定量分析方法。讨论了ICP-MS的STD、KED(He)、交互模式3种方法测定植物样品中7种金属元素结果。结果表明,利用工作曲线法配制Hg标准溶液,更改82Se在线校正方程系数为1.83,在ICP-MS的交互模式下测定植物样品中82Se、63Cu、60Ni、66Zn、111Cd、75As、202Hg可以得到准确可靠的结果,克服了植物样品中Se和Hg元素测定的难题。基于所建方法各元素校准曲线系数>0.999,方法检出限为0.000 4~0.08 mg/kg,加标回收率在96.2%~107%,测定GBW10010a(大米)、GBW10012(玉米)、GBW10021(豆角)3种标准物质,结果均在参考值范围内,相对标...  相似文献   

10.
Stir-bar sorptive extraction in combination with an in situ derivatisation reaction and thermal desorption–gas chromatography–mass spectrometry was successfully applied to determine parabens (methylparaben, isopropylparaben, n-propylparaben, butylparaben and benzylparaben), triclosan and methyltriclosan in water samples. This approach improves both the extraction efficiency and the sensitivity in the GC in a simple way since the derivatisation reaction occurs at the same time as the extraction procedure. The in situ derivatisation reaction was carried out with acetic anhydride under alkaline conditions. Thermal desorption parameters (cryofocusing temperature, desorption flow, desorption time, desorption temperature) were optimised using a Box–Behnken experimental design. All the analytes gave recoveries higher than 79%, except methylparaben (22%). The method afforded detection limits between 0.64 and 4.12 ng/L, with good reproducibility and accuracy values. The feasibility of the method for the determination of analytes in water samples was checked in tap water and untreated and treated wastewater.  相似文献   

11.
The feasibility of stir-bar sorptive extraction (SBSE) followed by liquid desorption in combination with large volume injection (LVI)-in port silylation and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of a broad range of 46 acidic and polar organic pollutants in water samples has been evaluated. The target analytes included phenols (nitrophenols, chlorophenols, bromophenols and alkylphenols), acidic herbicides (phenoxy acids and dicamba) and several pharmaceuticals. Experimental variables affecting derivatisation yield and peak shape as a function of different experimental PTV parameters [initial injection time, pressure and temperature and the ratio solvent volume/N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) volume] were first optimised by an experimental design approach. Subsequently, SBSE conditions, such as pH, ionic strength, agitation speed and extraction time were investigated. After optimisation, the method failed only for the extraction of most polar phenols and some pharmaceuticals, being suitable for the determination of 37 (out of 46) pollutants, with detection limits for these analytes ranging between 1 and 800 ng/L and being lower than 25 ng/L in most cases. Finally, the developed method was validated and applied to the determination of target analytes in various aqueous environmental matrices, including ground, river and wastewater. Acceptable accuracy (70-130%) and precision values (<20%) were obtained for most analytes independently of the matrix, with the exception of some alkylphenols, where an isotopically labelled internal standard would be required in order to correct for matrix effects. Among the drawbacks of the method, carryover was identified as the main problem even though the Twisters were cleaned repeatedly.  相似文献   

12.
《Analytica chimica acta》2004,522(2):259-266
A new procedure for Co determination in a complex matrix (coal fly ash) by slurry extraction-electrothermal atomic absorption spectrometry (ETAAS) is presented. Fractional experimental designs were applied to find the most important variables affecting Co extraction. Two liquid media (HCl + HNO3 and HF) and three agitation modes (ultrasonic probe, ultrasonic bath and manual shaking) were assayed. HF revealed as the most suitable medium for Co extraction, being its concentration and time of contact the most significant variables. Quantitative extraction was obtained after their optimisation (16%, v/v HF; 5 min), with good accuracy (coal fly ash SRM 1633a and SRM 1633b) and precision (R.S.D. < 11.5%). The limit of detection of the method was 0.02 μg g−1 (100 mg mL−1 slurry), and the characteristic mass was 15 ± 1 pg. The ‘slurry-extraction procedure’ established is simple, fast, cheap and was also validated for soil and sediment analysis. As far as we know, a slurry-extraction procedure has not yet been applied to quantify cobalt by ETAAS in such matrices. Moreover, nine coal fly ashes, 12 sediments and 18 soils were analysed by the proposed method and also by a direct slurry sampling-ETAAS procedure in order to compare their performance. In general, the HF-extraction slurry procedure revealed superior.  相似文献   

13.
Current approaches to mercury speciation and total trace element analysis require separate extraction/digestions of the sample. Ecologically important aquatic organisms--notably primary consumers such as zooplankton, polychaetes and amphipods--usually yield very low biomass for analysis, even with significant compositing of multiple organisms. Individual organisms in the lower aquatic food chains (mussels, snails, oysters, silversides, killifish) can also have very low sample mass, and analysis of whole single organisms is important to metal uptake studies. A method for the determination of both methyl Hg and total heavy metal concentrations (Zn, As, Se, Cd, Hg, Pb) in a single, low-mass sample of aquatic organisms was developed. Samples (2 to 50 mg) were spiked with enriched with (201)MeHg and (199)Hg, then leached in 4 M HNO(3) at 55 degrees C for extraction of MeHg. After 16 h, an aliquot (0.05 mL) was removed to determine mercury species (methyl and inorganic Hg) by isotope dilution gas chromatography inductively coupled plasma mass spectrometry (ICP-MS). The leachate was then acidified to 9 M HNO(3) and digested in a microwave at 150 degrees C for 10 min, and total metal concentrations were determined by collision cell ICP-MS. The method was validated by analyzing five biological certified reference materials. Average percent recoveries for Zn, As, Se, Cd, MeHg, Hg(total) and Pb were 99.9%, 103.5%, 100.4%, 103.3%, 101%, 97.7%, and 97.1%, respectively. The correlation between the sum of MeHg and inorganic Hg from the speciation analysis and total Hg by conventional digestion of the sample was determined for a large sample set of aquatic invertebrates (n = 285). Excellent agreement between the two measured values was achieved. This method is advantageous in situations where sample size is limited, and where correlations between Hg species and other metals are required in the same sample. The method also provides further validation of speciation data, by corroborating the sum of the Hg species concentrations with the total Hg concentration.  相似文献   

14.
Summary The spectral interferences by Al, Ca, Fe, K, Mg and Na in the direct simultaneous determination of As, Cd, Co, Cu, Hg, Pb and Se in plant and soil samples by ICP-AES are investigated, and a non-linear relationship between the apparent analyte concentration for As, Cd, Co, Hg and Se is observed. A correction method for non-linear spectral interferences is discussed and non-linear spectral correction coefficients are calculated.  相似文献   

15.
This paper describes a robust and sensitive HPLC method for determination of glyphosate in water and plant material after pre-column derivatisation with 9-fluorenylmethyl chloroformate (FMOC-Cl) using single and coupled polymeric amino columns, respectively. New findings about optimisation of the derivatisation reaction and chromatographic behaviour of glyphosate and AMPA on polymeric amino column are also presented.The best HPLC conditions for the separation of glyphosate and AMPA in water samples were achieved using a single polymeric amino column and mobile phase at pH 10 which contained 55% (v/v) acetonitrile and 50 mM phosphate buffer. The method was validated by analysing 10 fortified rainwater samples at a level of 1 μg/l. The average recovery was 94% with relative standard deviation (R.S.D.) of 5.4% and the method detection limit of 0.16 μg/l.The HPLC separation of glyphosate (only) in plant material entailed the coupling of two polymeric amino columns via a switching valve to separate interfering products from the desired analyte. The method was validated using grass samples spiked at the level of 1 mg/kg and gave a method detection limit of 0.3 mg/kg for glyphosate and a recovery of 82.4% with R.S.D. of 10.3%.  相似文献   

16.
The analysis of organic pollutants in environmental water samples requires a pre-concentration step. Pre-concentration techniques such as stir bar sorptive extraction (SBSE) have gained popularity since they minimise the use of toxic organic solvents and can be considered as green analytical techniques. Similar to other pre-concentration techniques, one of the problems when SBSE is used is the matrix effect, which often occurs during the analysis of environmental water samples such as estuarine or wastewater samples. The present work studied the matrix effect during SBSE coupled to in-tube derivatisation–thermal desorption (TD)–gas chromatography–mass spectrometry for the determination of several endocrine disruptor compounds, such as alkylphenols, bisphenol A, estrogens and sterols, in environmental water samples, after optimisation of the major variables affecting the determination. Variables such as the addition of methanol or an inert salt to the donor phase, the extraction temperature, the volume of the donor phase, the stirring rate and the extraction time were studied during the SBSE optimisation. In the case of the in-tube derivatisation and TD step, the volume of the derivatisation reagent (N,O-bis(trimethylsilyl)triufloroacetamide with 1% of trimethylchlorosilane (BSTFA + 1% TMCS)) and the cryo-focusing temperature were fixed (2 μL and −50 °C, respectively) according to a consensus between maximum signal and optimal operation conditions. Good apparent recovery values (78–124%) were obtained for most of the analytes in Milli-Q water, except for 4-tert-octylphenol (4-tOP), which showed apparent recovery values exceeding 100%. Precision (n = 4) was in the 2–27%, and method detection limits were in the low nanogrammes per litre level for most of the analytes studied. The matrix effect was studied using two different approaches. On the one hand, Milli-Q water samples were spiked with humic acids, and apparent recovery values were studied with and without correction with the corresponding deuterated analogue. On the other hand, estuarine water and wastewater samples were spiked with known concentrations of target analytes, and apparent recoveries were studied as explained above. In general, the matrix effect could be corrected with the use of deuterated analogues, except for 4-tOP and nonylphenols for which [2H4]-n-nonylphenol did not provide good corrections.  相似文献   

17.
The purpose of the study was to optimise analytical methods for determination of the chemical speciation of mercury in studies of protective mechanisms of selenium. Optimisation of the methods was performed using CRM DOLT-2 (Dogfish liver), both in its original form and after separation of various fractions. The sample was homogenised with 10 mM Tris-HCl buffer (pH 7.6) and ultracentrifuged. The soluble phase obtained was applied to a size exclusion chromatography column (Sephadex G-75 column) for separation of various protein fractions. Total mercury (total Hg), monomethyl mercury (MeHg) and selenium (Se) were determined in whole dogfish liver tissue and its soluble and insoluble phases (pellet). Different approaches for determination of total Hg and MeHg were compared. Simultaneous determination of MeHg and inorganic mercury (Hg2+) was based on alkaline dissolution and/or acid leaching, followed by ethylation, room temperature precollection, isothermal gas chromatography (GC), pyrolysis and detection with cold vapour atomic fluorescence spectrometry (CVAFS). The sum of MeHg and Hg2+ was compared to total Hg results obtained by acid digestion and CVAAS detection. The accuracy of MeHg determination was checked by its determination using acid leaching at room temperature, solvent extraction, back extraction into Milli-Q water, ethylation, GC and CVAFS detection. For the insoluble phase it is recommended to use solvent extraction for MeHg and acid digestion CVAAS for total Hg. For determination of MeHg and Hg2+ in the lyophilised sample and water soluble fractions containing low concentrations of mercury species, the simultaneous measurement of MeHg and Hg2+ after alkaline dissolution is the most appropriate method.  相似文献   

18.
Chen YW  Tong J  D'Ulivo A  Belzile N 《The Analyst》2002,127(11):1541-1546
Systematic experiments were conducted to evaluate and compare the analytical figures of merit of two reducing agents (SnCl2 and NaBH4) in a continuous flow cold vapor atomic fluorescence mercury analyzer. It was found that sodium tetrahydroborate can efficiently reduce Hg2+ in various environmental samples at a concentration as low as 10 microM (ca. 3.8 x 10(-5)% w/v). Most commonly encountered transition metals (Fe2+, Fe3+, Zn2+, Cu2+, Ni2+, Pb2+ and Cr3+) did not interfere with total Hg determination. No interference from hydride-forming elements (Se4+, Sb3+ and As3+) was observed. Interference caused by Mn2+ and Ag+ could be readily removed by dilution and by using appropriate modification of the reaction matrix. A higher concentration of NaBH4 (0.1 M) is stable for I month when stored in the NaOH matrix (0.2 M) and at low temperature (4 degrees C). A working solution of NaBH4 can be freshly prepared by dilution. With NaBH4, the whole continuous flow system is kept clean much more easily as no precipitate is formed, which in turn considerably reduces memory effects, simplifies analytical operation and reduces the chemical cost six-fold.  相似文献   

19.
对现有国标检测方法(GB/T 22105.1-2008和GB/T 22105.2-2008)进行改进,采用王水水浴浸提-双通道原子荧光光谱法同时测定土壤样品中砷、汞的含量。采用土壤国家一级标准物质GSS-3,GSS-8,GSS-9与山西农田土壤样品为试验对象,筛选得到检测砷、汞元素含量最佳实验条件及仪器工作条件。砷、汞的质量浓度分别在0~150μg/L,0~2μg/L范围内与荧光强度成良好的线性关系,线性相关系数均大于0.999,砷、汞的检出限分别为0.021,0.0015 mg/kg。测定结果的相对标准偏差为1.81%~4.64%(n=8),砷、汞的样品加标回收率分别为92.7%~103.0%,82.0%~95.5%。经国家一级标准物质验证,该法检出限、准确度和精密度均满足检测要求。改良后的方法可以同时准确、快速地测定土壤中砷、汞,极大地提高了工作效率,可以更好地适应当前大量的土壤分析工作。  相似文献   

20.
《Analytical letters》2012,45(15):2257-2268
An analytical procedure was developed for determination of Hg, As, Pb, and Cd in soil samples using sequential injection vapor generation atomic fluorescence spectrometry (SI-VG-AFS) with sample preparation by microwave digestion system. The effects of analytical conditions on the fluorescence intensity were investigated and optimized. Under the optimized condition, the detection limits of the method were 5, 68, 40, and 3 ng L?1 for Hg, As, Pb, and Cd, respectively. The accuracy of method was verified by the determination of the certified reference soil, and the recoveries for Hg, As, Pb, and Cd were in the range of 98.7–106.1%. The proposed method has been successfully applied to determine the heavy metals in navel orange orchard soils in Ganzhou, and the environmental quality of the orchard soils was assessed based on the content of the heavy metals. According to the second criterion of environmental quality standard for soils, Pb content in all soil samples collected from the orchards of 18 districts were within safe limits, but a few orchards were slightly contaminated with Hg, As, and Cd. Comparison of heavy metal mean concentrations with the safe limits of environmental quality standard for soils, the quality of Ganzhou navel orange orchard soils were in line with the request of the green food production base.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号