共查询到20条相似文献,搜索用时 15 毫秒
1.
A technique is described for the determination of total gaseous lead in the atmosphere by honeycomb denuder collection, followed by an electrothermal atomic absorption spectrometry (ETAAS) measurement. The collection efficiency of the honeycomb denuder in which a solution containing 2% HNO3/2% glycerine/1% ammonium dihydrogenphosphate was coated for trapping the gaseous lead in the atmosphere was 98.8%. The linear absorbance response was obtained for a concentration range of 0-1.39 microg m(-3) of lead in the atmosphere. A precision of 4.8% RSD (peak-height absorbance, n = 11) for an aqueous solution of 1 ng of lead standard, characteristic masses (CM) of 23 pg and detection limit (3sigma) of 54 pg for an aqueous solution of 0.01 ng lead standard was achieved with 100 microg ammonium dihydrogenphosphate as a chemical modifier. The average recovery of lead in three standard samples prepared by the independent digestion of NIST SRM 1648 (Urban Particulate Matter) using our analytical system was 97.8%. The total content of the gaseous lead in the atmosphere of our laboratories was 0.35-0.38 microg m(-3). 相似文献
2.
A procedure based on differential pulse cathodic stripping voltammetry on the graphite electrode is described for the determination of dissolved manganese in natural waters buffered at pH about 6.5 with acetate solution. In order to avoid interference of iron(II) the addition of fluoride is used. The limit of detection is 3 g/l for a deposition time of 6 min. Acidification and UV-irradiation are recommended for samples containing dissolved organic matter. Results of manganese determination in table mineral waters are reported and the possibility of manganese speciation is discussed. 相似文献
3.
研究了呋喃唑酮在玻碳电极上的伏安行为。在 1mol LHCl底液中 ,用微分脉冲阴极溶出伏安法得到一灵敏的呋喃唑酮还原峰 ,峰电位为 0 .0 38V(vs.Ag AgCl)。峰电流与呋喃唑酮浓度在 8× 1 0 -6~ 1× 1 0 -4 mol L范围内呈线性关系 (r=0 .9984) ,检出限为 8× 1 0 -8mol L。该法已用于片剂与合成血清样品中呋喃唑酮含量的测定 相似文献
4.
A procedure is presented for determining Se(IV) and total dissolved Se in sea water using cathodic stripping voltammetry in the presence of added copper. Experiments using cyclic voltammetry indicate that the preconcentration step consists in adsorption of a Cu(I)2Se complex species on the hanging mercury drop electrode. The optimized analytical conditions include a copper concentration of 40 μM and a solution pH of 1.6. Differential pulse modulation is used. Interference caused by organic surface-active substances present in natural waters in eliminated by UV photolysis of the sample. Cadmium interferes with the determination of Se only when present at a concentration 100 times higher than normal. UV photolysis at pH ≈ 8 is used to convert Se(VI), which is the electroactive species. The response is linear for Se concentrations between 0 and 200 nM. The limit of detection is 0.01 nM Se when a deposition time of 15 min is used. 相似文献
5.
C. L. Rojas S. B. Maroto P. Valenta 《Fresenius' Journal of Analytical Chemistry》1994,348(11):775-776
A new voltammetric method is elaborated for the trace determination of selenium in soils. The use of the square-wave cathodic stripping voltammetry in the determination step efficiently eliminates the interference of electroactive components. The detection limit is 0.75 g/l. 相似文献
6.
A voltammetric method for the determination of 3-mercapto-D-2-methylpropanoyl-L-proline, a hypotensive drug whose pharmaceutical name is Captopril (CPT), in the concentration range from 9.0×10−10M to 3×10−6M, is described. In this range the peak current increases linearly with drug concentration even when different collection periods are used. A self-cleaning Hanging Mercury Drop Electrode (HMDE) was used and a negative Differential Pulse potential (DP) was applied to the indicator electrode. The stripping peak of CPT splits into two peaks as soon as the concentration is increased over about 10−5M; in the oxidation DP scan, instead, this splitting is observed at a concentration of 2.0×10−4M. Some attempts were made to verify the suitability of other techniques such as Alternating Current polarography (AC) and the use of a different electrode, the Wax-Impregnated Graphite Electrode (WIGE). 相似文献
7.
An analytical method was developed for the determination of total dissolved selenium in fresh waters, using linear sweep cathodic stripping voltammetry (CSV) in combination with UV photolytic digestion. Both the CSV method, based on the electrodeposition and stripping of Cu(2)Se, and the UV irradiation procedure were investigated in detail. In the presence of dissolved organic substances, as in freshwaters, Se(VI) is reduced to Se(IV) by UV irradiation in 0.1M hydrochloric acid. Glucose can be used as the carbon source in samples low in natural dissolved organic carbon (DOC). The photolytic yields of Se(IV) were about 90% in both cases. Five freshwater samples were analysed for total selenium by CSV after UV photolysis, and by hydride generation atomic absorption spectrometry (HG-AAS) after oxidative digestion followed by reduction with hydrochloric acid. The results agreed well and the concentrations were in the range 70-190 ng/l., well above the detection limit of the CSV method at 2 ng/l. 相似文献
8.
微分脉冲阴极溶出伏安法测定阿米卡星 总被引:1,自引:1,他引:0
硫酸阿米卡星(Am ikacin sulfate)是一种氨基糖苷酸类抗生素,化学名为O-3氨基-3-脱氧-а-D-蒲吡喃糖基-(1-6)-O-[6-氨基-6-脱氧-а-D-蒲吡喃糖基-(1-4)]-N-(4-氨基-2-羟基-1-氧丁基)-2-脱氧?D-链霉胺硫酸盐。目前报道的测定方法主要有高效液相法[1]、镍毛细管电泳法[2]。本文研究了阿米卡星在玻碳电极上的电化学行为。微分脉冲溶出伏安法是一种灵敏度很高的痕量分析方法,本文利用该方法对阿米卡星进行了测定,发现阿米卡星在pH=2的盐酸底液中,产生一灵敏的还原峰,可用于定量测定。平行测定了7次,RSD为2·05%,该方法可用于注射液及血清中… 相似文献
9.
Summary The determination of gallium traces is carried out on the hanging drop mercury electrode in solutions of low ionic strength and in absence of complexing agents. At pH=3.2, where stable solutions are obtained, concentrations of 0.2 g Ga l–1 are determinated with a standard deviation of 0.96% and a detection limit of 4 ng Ga l–1.The effect of various instrumental parameters is investigated and optimized conditions established. The theory of differential pulse anodic stripping voltammetry is verified with the results obtained experimentally. The use of salicylate as base electrolyte is also considered.
Bestimmung von Galliumspuren durch Differentialpuls-Anodic Stripping-Voltammetrie相似文献
10.
Determination of naringin in grapefruit juice by cathodic stripping differential pulse voltammetry at the hanging mercury drop electrode 总被引:1,自引:0,他引:1
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated. 相似文献
11.
D. W. Bryce A. Izquierdo M. D. Luque de Castro 《Fresenius' Journal of Analytical Chemistry》1995,351(4-5):433-437
A semi-automatic continuous method for the determination of Se(IV) based on flow-injection cathodic stripping voltammetry (FICSV) is reported. The flow injection approach incorporates a thin mercury film on glassy carbon as the working electrode, on which Se(IV) is deposited at an applied potential of 0.0 V. A cathodic scan (from 0.0 to –0.9 V) is applied and the Se is stripped at –0.54 V, providing a current intensity proportional to the Se(IV) concentration in the sample. This method features a linear determination range between 0.5 and 30 ng/ml (r2=0.998, RSD=3.6%). The non-interference levels (foreign species to analyte ratio) are 2.5:1 for Cu(II), 7.5:1 for Pb(II), 35:1 for Cd(II), 250:1 for Zn(II) and 500:1 for Fe(III). After developing the method for Se(IV), the speciation of this element has been performed by sequential injection of the dissolved sample into a carrier which may or may not have been previously reduced off-line thus determining the sum (Se(IV)+Se(VI)) or only Se(IV), respectively. The method has been applied to selenium speciation in water samples. 相似文献
12.
A method has been designed for the reduction of iodate to iodide in seawater and subsequent determination of total dissolved iodine as iodide by cathodic stripping square wave voltammetry. The pH of the sample is lowered to about 1-2 and iodate is reduced to iodide with sodium sulfite under this acidic condition. The pH of the sample is then raised to 8-9 before the concentration of iodide is measured. 相似文献
13.
Determination of chitosan by cathodic stripping voltammetry. 总被引:1,自引:0,他引:1
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of CTS from 5.0 x 10(-7) to 1.5 x 10(-5) g ml(-1), and the detection limit is 1.0 x 10(-7) g ml(-1). We studied the characteristics and the mechanism of the electrode reaction, which proved that this process was diffusion controlled. This method was applied to determine the content of CTS in real samples with satisfactory results. 相似文献
14.
A study of chlorophenols using differential pulse cathodic stripping voltammetry (dpcsv) is reported. Of the wide range of chlorophenols investigated, only pentachlorophenol and 2,3,4,6-tetrachlorophenol yield stripping peaks.For pentachlorophenol in water, two peaks are obtained at stripping potentials of –1.2 V and –1.58 V versus SCE. In methanol, pentachlorophenol shows one peak with a stripping potential at –1.6 V versus SCE.In the case of 2,3,4,6-tetrachlorophenol in water, two peaks are observed at –1.06 V and –1.6 V versus SCE, while in methanol only one peak arises at a stripping potential of –1.6 V. A procedure was developed for the determination of pentachlorophenol in natural waters. 相似文献
15.
Lucas Hernandez Pedro Hernandez Encarnacion Lorenzo Claudio Gonzalez Inmaculada Gonzalez 《Fresenius' Journal of Analytical Chemistry》1990,336(3):222-225
Summary A method is described for the determination of Bentazepam using DPP and ADSV with DP. Bentazepam is determined in buffer Britton-Robinson 0.04 mol l-1 at pH 9 with detection limits of 3.1×10-9 mol/l and a relative standard deviation of 0.8 DPP was used to determine Bentazepam in Tiadipona, the commercial product. ADSV was used to determine Bentazepam in urine with a detection limit of 2.7 ng ml-1 (accumulation time 5 min) and a relative standard deviation of 1.5%. 相似文献
16.
A procedure was developed for the determination of cadmium in sewage sludge by differential pulse anodic stripping voltammetry. A sodium peroxide fusion carried out in zirconium crucibles was found to give satisfactory results, based on analysis of standard reference materials. Samples collected from the municipal sludge lagoon in Fort Wayne, Indiana were found to have cadmium abundances ranging from 120 to 250 ppm, with most samples falling in the 120 to 170 ppm range. Interference from zinc is easily eliminated by carrying out the deposition step at -0.95 V vs. Ag/AgCl. Lead-to-cadmium ratios as high as 50:1 (ppm basis) have no effect on the height of the cadmium peak. 相似文献
17.
A method is described for the determination of selenium by differential pulse cathodic-stripping voltammetry (DPCSV) at a hanging mercury-drop electrode. The dried sample is burnt in an oxygen flask and the selenium absorbed in a persulphate-sulphuric acid mixture. The solution is analysed by DPCSV following treatment with hydrochloric acid to destroy excess of persulphate and to reduce the Se(VI) to Se(IV). Results are given for two soils and a series of plant materials and compared with those obtained by fluorimetric analysis by means of the 2,3-diaminonaphthalene piazselenol complex. 相似文献
18.
A method was developed to determine the biocide pyrithione in natural waters. The method is based on cathodic stripping voltammetry (CSV) in the presence of Triton-X-100, which is used to separate the peak from interfering thiol compounds. Optimised conditions include a Triton-X-100 concentration of 4 ppm and a pH adjusted to 9 using ammonia buffer. The adsorption potential for pyrithione was −0.10 V and the peak occurred at −0.2 to −0.3 V. Detection was by differential-pulse CSV. The detection limit in UV-digested seawater was 1.5 nM for a deposition time of 60 s. In principle, this limit of detection could be lowered by extending the adsorption time, but in practice this may not be possible due to interferences by other organic compounds (surfactants and thiol compounds) in natural waters. 相似文献
19.
20.
A method for the determination of nickel(II) by stripping voltammetry is described. The method is based on the adsorptive accumulation of nickel(II) calconcarboxylic acid complex onto a hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed complex using differential pulse voltammetry. The optimum operating conditions and parameters were found to be 0.05 M NH3/NH4Cl buffer (pH = 9.5) as the supporting electrolyte, a ligand concentration of 1 × 10?6 M, accumulation potential of ?0.5 V (vs. Ag/AgCl) and accumulation time of 60 s. At the optimized conditions, the peak current is proportional to the concentration of nickel in the range of 1.7 × 10?9 to 4.7 × 10?7 M (0.1–28 ng ml?1) with a detection limit of 0.05 ng ml?1. The relative standard deviation (n = 10) at nickel concentrations of 2, 10 and 15 ng ml?1 varies in the range 0.76 to 2.1%. Possible interferences by metal ions, which are of great significance in real matrices, have been studied. The method was successfully applied to the determination of nickel content in a chocolate sample. 相似文献