首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The reaction, involving the oxidation of thiamine by copper(II) in basic solutions to fluorescent thiochrome, has been adapted to the determination of thiamine by flow-injection analysis. Linear calibration graphs are obtained between 0.30 and 6.02 mug/ml with a sampling rate of 50 samples/hr and a relative standard deviation of 0.53%. This reaction has also been adapted to the determination of copper(II) over the range 0.5-5.0 mug/ml. The applicability of both methods for determination of thiamine and copper is demonstrated by investigating the effect of potential interferences and by the analysis of real samples (pharmaceuticals for thiamine and ores and alloys for copper).  相似文献   

2.
Aly FA  Al-Tamimi SA  Alwarthan AA 《Talanta》2001,53(4):885-893
A new chemiluminescence (CL) method using flow injection has been described for the rapid and sensitive determination of three fluoroquinolone derivatives, namely ofloxacin, norfloxacin and ciprofloxacin hydrochloride. The method is based on the CL reaction of the studied fluoroquinolones with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bipy)(3)(2+)] and Ce(IV) in sulfuric acid medium. Under the optimum conditions, the CL intensity is proportional to the concentration of the drugs in solution over the range 0.05-7.0 mug ml(-1) for norfloxacin, 0.05-6.0 mug ml(-1) for ciprofloxacin hydrochloride and 0.003-0.7 mug ml(-1) for ofloxacin. The limits of detection (s/n=3) were 3.1x10(-8) M norfloxacin, 2.6x10(-8) M ciprofloxacin hydrochloride and 5.5x10(-9) M ofloxacin. The method was applied successfully to the determination of these compounds in dosage forms and biological fluids.  相似文献   

3.
Aly FA  Alarfaj NA  Alwarthan AA 《Talanta》2001,54(4):715-725
A simple, highly sensitive chemiluminescent method using flow injection is described for the determination of three substituted benzamides, namely: sulpiride, sultopride and tiapride. The method is based on the sensitizing effect of these drugs on the chemiluminometric oxidation of sulphite by cerium(IV). The different experimental parameters affecting the chemiluminescence intensity were carefully studied and incorporated into the procedure. The method permits the determination of 0.05-2.5 mug ml(-1) sulpiride, 0.01-2.5 mug ml(-1) sultopride hydrochloride and 0.01-1.5 mug ml(-1) tiapride hydrochloride with minimum detectability of 0.01 mug ml(-1). The method was applied to the determination of these benzamides in pharmaceutical preparations and biological fluids.  相似文献   

4.
Li B  Zhang Z  Wu M 《Talanta》2000,51(3):515-521
A novel chemiluminescence (CL) flow system for the determination of quinine is described. It is based on the direct chemiluminescence reaction of quinine and cobalt(III) in sulfuric acid medium. The unstable Co(III) was on-line electrogenerated by constant-current electrolysis. The chemiluminescence intensity was linear with a quinine concentration in the range of 0.1-100 mug ml(-1). The determination limit was 3.3x10(-8) g ml(-1). The whole process could be completed in 1 min. The proposed method is suitable for automatic and continuous analysis, and has been applied successfully to the analysis of quinine in pharmaceutical preparation.  相似文献   

5.
Zhang Z  Qin W 《Talanta》1996,43(1):119-124
A novel flow sensor based on chemiluminescence (CL) for the determination of ascorbic acid has been proposed. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion-exchange resin column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column through sodium phosphate injection, was decreased in the presence of ascorbic acid. The CL emission intensity was linear with ascorbic acid concentration in the range 0.01-0.8 mug ml(-1); the detection limit was 5.5 x 10(-3) mug ml(-1). The whole process, including sampling and washing, could be completed in 1 min with a relative standard deviation of less than 5%. The sensor could be reused more than 100 times and has been applied successfully to the analysis of ascorbic acid in pills and vegetables.  相似文献   

6.
Zhou Y  Nagaoka T  Li F  Zhu G 《Talanta》1999,48(2):461-467
A novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO(4). Hydrogen peroxide can be directly determined by luminol-KIO(4)-H(2)O(2) CL system. The detection limit was 3.0x10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0x10(-7)-6.0x10(-4) mol l(-1). The relative standard deviation of H(2)O(2) was 1.1% for 2.0x10(-6) mol l(-1) (N=11). Glucose was indirectly determined through measuring the H(2)O(2) generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H(2)O(2), which, in turn, coupled with the luminol-KIO(4)-H(2)O(2) CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mug ml(-1). The relative standard deviation was 2.1% for 10 mug ml(-1) (N=11). Detection limit of glucose was 0.08 mug ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO(4)-H(2)O(2) CL system. The calibration curve was linear over the range of 1.0x10(-7)-1.0x10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0x10(-7) mol l(-1) (N=11). Detection limit of ascorbic acid was 6.0x10(-8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection.  相似文献   

7.
Grekas N  Calokerinos AC 《Talanta》1990,37(11):1043-1048
The chemiluminescence produced by oxidation of thiamine by ferricyanide in alkaline medium has been investigated by using a simple continuous flow analyser and a procedure developed for the determination of thiamine hydrochloride or nitrate in the range 2.00 x 10(-5)-5.00 x 10(-4)M (equivalent to 6.75-169 mug/ml thiamine hydrochloride) with coefficients of variation <2%. A measurement rate of 112/hr can be obtained. When applied to pharmaceutical formulations, the only interferent among common excipients and coexisting drugs is ascorbic acid. The results obtained for the assay of dosage forms compared well with those obtained by an official method and demonstrated an error <4%.  相似文献   

8.
Sedaira H 《Talanta》2000,51(1):39-48
A new direct spectrophotometric determination of manganese with 5,8-dihydroxy-1,4-naphthoquinone (naphthazarin,NAZA) is reported. Absorption maximum, molar absorptivity and Sandell's sensitivity of 1:2 (M:L) complex are 695 nm, 1.88x10(4) l mol(-1) cm(-1) and 2.92 ng cm(-2), respectively. A linear calibration graph is obtained up to a concentration of 7.2 mug ml(-1) of manganese. The optimum range for determination (Ringbom) is between 0.20 and 6.8 mug ml(-1). A rapid method for simultaneous determination of manganese and zinc in their mixture using derivative spectra is described. The range 0.28-5.6 mug ml(-1) manganese could be determined in the presence of 0.33-6.8 mug ml(-1) zinc and vice versa. The developed method was applied to the simultaneous spectrophotometric determination of manganese and zinc in some synthetic mixtures and was found to give satisfactory results.  相似文献   

9.
Yang W  Teng XL  Chen M  Gao JZ  Yuan L  Kang JW  Ou QY  Liu SX 《Talanta》1998,46(4):527-532
In the present paper, N,N'-dinaphthyl-N,N'-diphenyl-3,6-dioxaoctanediamide acts as a specific reagent for enhancing the fluorescence intensity of Eu(III) complex with thenoyl trifluoroacetone (TTA), the spectrofluorimetric determination of trace amounts of Eu(III) based on the above system was carried out and its luminescence mechanism was studied. The excitation and emission wavelengths are 343.6 and 613.3 nm, respectively. The fluorescence intensities vary linearly with the concentration of europium(III) in the range 3.647x10(-3)-3.039 mug ml(-1) for the original fluorescence with a detection limit down to 2.279x10(-4) mug ml(-1) and the standard deviation is 0.063 mug ml(-1) for 10 times measurements, and in the range 7.598x10(-4)-0.0243 mug ml(-1) (SD=0.035 for 15 times measurements), 0.06078-0.6100 mug ml(-1) (SD=0.52 for 10 times measurements) for the first derivative fluorescence signal with a detection limit down to 8.566x10(-5) mug ml(-1). The interferences of other rare earths and some of inorganic ions are described. This method is a direct, rapid, selective and sensitive analytical method for the determination of trivalent europium in rare earth ore samples and high purity of rare earth oxides.  相似文献   

10.
Aly FA  Alarfaffj NA  Alwarthan AA 《Talanta》1998,47(2):471-478
A chemiluminescent method using flow injection is described for the determination of cefadroxil monohydrate. The method is based on the chemiluminescence reaction of cefadroxil with potassium permanganate in sulphuric acid, sensitized by quinine. The proposed procedure allows the determination of cefadroxil over the concentration range 0.1-30 mug ml(-1) with a detection limit of 0.05 mug ml(-1) and a sample measurement frequency of 150 samples h(-1). The method was successfully applied to the determination of cefadroxil in pharmaceutical preparations and biological fluids.  相似文献   

11.
A 1:12 phosphomolybdic anion film modified carbon paste electrode (PMo(12) electrode) is prepared by electrochemical deposition and its application is studied by cyclic voltammetry. The film modified electrode can adsorb PMo(12) selectively and thus be used for the determination of trace phosphorus. In a solution containing 2 mug ml(-1) phosphorus, the relative standard deviation is 4.69% (n=4), the peak height also varies linearly with the concentration of phosphorus over the range 0.4-25 mug ml(-1), and the detection limit is 0.04 mug ml(-1). The method is convenient and rapid. It has been used for the determination of inorganic phosphorus in phytic acid directly with satisfactory results.  相似文献   

12.
Paseková H  Polásek M 《Talanta》2000,52(1):67-75
Local anaesthetics procaine hydrochloride (I), benzocaine (II), and tetracaine hydrochloride (III) were determined by the technique of sequential injection analysis (SIA) with chemiluminescence (CL) detection. The CL was emitted during the oxidation of the analytes by permanganate in aqueous sulphuric acid in the presence of various CL enhancers (4-hydroxybiphenyl, Rhodamine B, glycolaldehyde, glutaraldehyde and formic acid). The optimum enhancer or reagent concentrations, order and volumes of the injected zones were: 0.37 M formic acid (40, 23 or 28 mul for I-III, respectively), sample (40 mul), 2.3 M H(2)SO(4) (20, 16 or 18 mul for I-III, respectively), and 0.5 mM KMnO(4) (19, 13 or 15 mul for I-III, respectively). After a double (or single for III) reversal of the flow the mixed zone was pushed into the detector at a flow rate of 100 mul s(-1). The transient CL signal was recorded at >/=390 nm. The calibration graphs relating the intensity of the emission (peak heights) to the concentration of the analytes were curvilinear (a second order polynomial showed the best fit) and they were suitable for determining I-III in the ranges 0.5-50, 0.5-25 and 0.2-25 mug ml(-1), respectively. The limits of detection (3sigma) were 0.3 mug ml(-1) for I and II and 0.1 mug ml(-1) for III. The sample throughput was 120 h(-1). The relative standard deviations were 相似文献   

13.
Akseli A  Rakicioğlu Y 《Talanta》1996,43(11):1983-1988
Sodium triphosphate acts as a specific reagent for enhancing the fluorescence intensity of cerium(III). The purpose of this study was to investigate the spectrofluorimetric determination of trace amounts of Ce(III) in sodium triphosphate solution. The excitation and emission wavelengths are 303.5 nm and 353 nm respectively. Optimum sodium triphosphate concentration is found to be 0.074 g l(-1) at room temperature. The fluorescence varies linearly with the concentration of cerium(III) in the range 0.001-45 mug ml(-1). The detection limit is 9.4 x 10(-4)mug ml(-1). The relative standard deviations for 30 mug ml(-1) and 0.05 mug ml(-1) Ce(III) in 0.074 g l(-1) sodium triphosphate solution are 1.1% and 0.72% respectively. Quenching effects of other lanthanides and some inorganic anions are described. This method is a direct and rapid analytical method for the determination of Ce(III) in rare earth mixtures and cerium concentrates.  相似文献   

14.
Zhao S  Xia X  Yu G  Yang B 《Talanta》1998,46(5):845-850
A flow-injection method for the simultaneous determination of iron and zinc in the human hair with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) using a pH gradient technique has been developed. The linear range for the determination of iron is 0.1 approximately 1.8 mug ml(-1) and for zinc is 0.2 approximately 5.0 mug ml(-1). About 20 approximately 30 samples can be determined in 1 h. The proposed method is simple, rapid and accurate. It has been applied to the simultaneous determination of trace amounts of iron and zinc in the human hair with satisfactory results.  相似文献   

15.
A novel, rapid and sensitive analytical method is described for determination of ofloxacin and levofloxacin by enhanced chemiluminescence (CL) with flow-injection sampling. The method is based on the CL reaction of the Ce(IV)-Na2S2O4-ofloxacin/levofloxacin-H2SO2 system. The enhanced CL mechanism was developed and the optimum conditions for CL emission were investigated. The CL intensity was correlated linearly (r = 0.9988) with the concentration of ofloxacin (or levofloxacin) in the range of 1.0 x 10(-8) - 1.0 x 10(-7) g ml(-1) and 1.0 x 10(-7) - 6.0 x 10(-6) g ml(-1). The detection limit (S/N = 3) is 7 x 10(-9) g ml(-1). The relative standard derivation (RSD, n = 11) is 2.0% for ofloxacin at 4 x 10(-7) g ml(-1) and for levofloxacin at 6 x 10(-7) g ml(-1). This method has been successfully applied for the determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids with satisfactory results.  相似文献   

16.
Huang Y  Chen Z 《Talanta》2002,57(5):953-959
A new chemiluminescence (CL) method is proposed for the determination of chlorpromazine hydrochloride, a drug often used to treat the psychiatric patients suffering from clinical depression. The method is based on the reaction between studied drug and Ce(IV) in a nitric acid medium and measurement of the CL intensity produced by rhodamine 6G used as a sensitizer. In the optimum conditions, CL intensities are proportional to concentrations of the studied drug over the range 0-1x10(-5) g ml(-1) with a detection limit of 6.5x10(-9) g ml(-1). The relative standard deviation (R.S.D.) is 4.1% for 1.5x10(-6) g ml(-1) chlorpromazine hydrochloride (n=11). The method has been applied to the determination of studied drug in tablets and biological fluids with satisfactory results.  相似文献   

17.
Li B  Zhang Z  Zhao L  Xu C 《Talanta》2002,57(4):765-771
A novel chemiluminscence (CL) flow-through sensor for ofloxacin is described. It was based on the sensitizing effect of ofloxacin on the CL oxidation of sulfite by PbO(2) in H(2)SO(4) media. By a very simply means, the solid-phase PbO(2) was immobilized inside of the CL flow cell as CL oxidant. The column of solid PbO(2) could be reused about 400 times during a period of 50 h. The calibration graph is linear in the range 0.2-10 mug ml(-1) with a detection limit of 7.8x10(-8) g ml(-1) (S/N=3). This method has been successfully applied to determine ofloxacin in pharmaceutical preparation.  相似文献   

18.
A simple, rapid and sensitive flow injection spectrophotometric method for determination of selenium (0.005-1.5 mug ml(-1)) is described. The method is based on the catalytic effect of Se(IV) on the reduction reaction of thionine (TN) with sulphide ion, monitored spectrophotometrically at 598 nm. The detection limit is 5 ng ml(-1) the relative standard deviation for eight replicate measurements is 1.1% for 1 mug ml(-1) of selenium. The sampling rate is 25-30 samples h(-1). The procedure was applied successfully to the determination of selenium in real samples.  相似文献   

19.
A new procedure for the determination of clenbuterol is proposed using flow-injection and fluorimetric detection. The method is based on the derivatization reaction of the primary amine group with o-phthalaldehyde in the presence of 2-mercaptoethanol. The calibration graph based on peak area was linear in the range 0.2-5 mug ml(-1) and the detection limit was 0.06 mug ml(-1). The method was validated using a reference spectrophotometric procedure and was applied to the determination of the drug in commercial pharmaceutical preparations.  相似文献   

20.
Zaia DA  Verri WA  Zaia CT 《Talanta》1999,49(2):373-376
A previous study was undertaken to test the reaction of several quinones (p-benzoquinone; 2,5-dichloro and 2,6-dichloro p-benzoquinone; tetrachloro-p-benzoquinone; tetrachloro-o-benzoquinone; 2,5-dichloro-3,6-dihydroxy-p-benzoquinone; benz[a]anthracene-7,12-dione) with bovine serum albumin (BSA). From this study, we have devised a spectrophotometric method for determination of total proteins. The quinone, tetrachloro-p-benzoquinone (p-chloranil), showed the best result. The product of reaction between proteins and p-chloranil absorbed at 360 nm and Beer's law was followed up to 200 mug ml(-1) of BSA. The product of reaction of BSA/p-chloranil was stable for 30 min, after that the absorbance increased 16% and kept stable for 24 h. The p-chloranil method showed a limit of detection (1.25 mug ml(-1)) lower than the biuret method (52.0 mug ml(-1)) or p-benzoquinone (PBQ) method (2.6-4.0 mug ml(-1)). The method was applied to spectrophotometric determination of total proteins in blood plasma; the results were compared with the biuret method that is widely used in clinical analysis.  相似文献   