1.
Acar O 《Talanta》2001,55(3):613-622
The electrothermal atomic absorption spectrometric determination of cadmium and lead in biological certified reference materials (CRMs) has been carried out by using NH(4)H(2)PO(4), Ni, Pd, Ni+NH(4)H(2)PO(4), Pd+NH(4)H(2)PO(4) and Ni+Pd+NH(4)H(2)PO(4) as chemical modifiers. A comprehensive comparison was made among the modifiers in 1% Triton X-100 plus 0.2% nitric acid as diluent and without modifier. Zeeman background correction and graphite tubes inserted with platforms were used. Comparison was made in terms of pyrolysis and atomization temperatures, atomization and background absorption profiles. Ni+Pd+NH(4)H(2)PO(4) modifier mixture was found to be preferable for the determination of Cd and Pb. Pyrolysis temperatures of analytes were increased up to 900 degrees C for Cd and 1250 degrees C for Pb by using Ni+Pd+NH(4)H(2)PO(4) in 1% Triton X-100 plus 0.2% nitric acid diluent solution. Biological CRMs were analyzed to verify the accuracy and precision of this method. Depending on the biological sample type, the percent recoveries were increased from 62 to 102% for Cd and from 58 to 106% for Pb by using the proposed modifier mixture. The detection limits of Cd and Pb were found to be 0.04, 0.92 mug l(-1), respectively.  相似文献   

2.
Three chemical modifiers ((NH(4))(2)HPO(4), NH(4)H(2)PO(4), and Pd as Pd(NO(3))(2)) were evaluated for the determination of Cd in acid-digested solutions of hair and blood using electrothermal atomic absorption spectrometry in a tungsten coil atomizer (TCA). All modifiers caused some thermal stabilization of Cd when compared to the behavior observed in nitric acid medium. The best effects were observed in 15 mug ml(-)(1) Pd medium; the characteristic mass of Cd was 0.3 pg and the method detection limits were 0.009 mug g(-)(1) in hair and 0.2 mug l(-)(1) in blood. In addition to a slight thermal stabilization effect, Pd also increased the sensitivity for Cd by ca. 40% and the tungsten coil lifetime by 20% (i.e. from 300 to 360 heating cycles), reduced background signals, and eliminated condensed phase interferences caused by concomitants. The accuracy (3.2% as mean relative error in the Pd modifier) was checked for the determination of Cd in acid-digested solutions of certified reference materials of human hair and blood and by recoveries of Cd in spiked hair and blood samples by both TCA and a graphite furnace procedure. All results obtained in chemical modifiers are in agreement at a 95% confidence level.  相似文献   

3.
This method was developed to improve sensitivity and eliminate time consuming, evaporative pre-concentration in AOAC Method 973.82 and American Society for Testing and Materials method C738 for testing foodware. The method was developed using leach solutions obtained by leaching 9 differently decorated ceramic vessels with 4% acetic acid for 24 h at room temperature. Lead and cadmium concentrations in leach solutions were 0.005-17,600 and 0.0004-0.500 microg/mL, respectively. Concentrations were determined using peak area, phosphate chemical modifier (8.3 microg PO4(-3)), and a standard curve for quantitation. Optimized pre-atomization and atomization temperatures were 1,300 and 1,800 degrees C, respectively, for Pb and 1,100 and 1,700 degrees C, respectively, for Cd. Characteristic masses (mo) were 10 and 0.4 pg for Pb and Cd, respectively. Precision of repeated analyses of calibration solutions was < or =3% relative standard deviation. Precision of duplicate leach solution analyses on different days was 0-9% relative difference. Recovery from fortified leach solutions was 96-106%. Results obtained by this method agreed 92-110% with those of confirmatory analyses. Results of certified reference material solutions agreed 94-100% with certificate values. Pb and Cd limits of quantitation (LOQ) were 0.005 and 0.0005 microg/mL, respectively. Results from 3 trial laboratories for 4 leach solutions containing Pb and Cd concentrations of 0.017-1.47 and <0.0005-0.0864 microg/mL, respectively, agreed 89-102% with results of the author. Two attributes of this method were noteworthy: (1) Background absorbance due to organic matter was entirely absent from atomization profiles, making the use of short pre-atomization hold times (2 s) possible. (2) Instrument precision was excellent and only one determination per solution was needed. Acceptance criteria for quality control measurements and a practical procedure for estimating the method LOQ during routine regulatory analyses are described.  相似文献   

4.
A multi-element graphite furnace atomic absorption spectrometry (GFAAS) method was elaborated for the simultaneous determination of As, Cd, Cu, and Pb in wine samples of various sugar contents using the transversally heated graphite atomizer (THGA) with end-capped tubes and integrated graphite platforms (IGPs). For comparative GFAAS analyses, direct injection (i.e., dispensing the sample onto the IGP) and digestion-based (i.e., adding oxidizing agents, such as HNO(3) and/or H(2)O(2) to the sample solutions) methods were optimized with the application of chemical modifiers. The mixture of 5 microg Pd (applied as nitrate) plus 3 microg Mg(NO(3))(2) chemical modifier was proven to be optimal for the present set of analytes and matrix, it allowing the optimal 600 degrees C pyrolysis and 2200 degrees C atomization temperatures, respectively. The IGP of the THGA was pre-heated at 70 degrees C to prevent the sputtering and/or foaming of sample solutions with a high organic content, dispensed together with the modifier solution, which method also improved the reproducibility of the determinations. With the digestion-based method, the recovery ranged between 87 and 122%, while with the direct injection method it was between 96 and 102% for Cd, Cu, and Pb, whereas a lower, compromise recovery of 45-85% was realized for As. The detection limits (LODs) were found to be 5.0, 0.03, 1.2, and 0.8 microg l(-1) for As, Cd, Cu, and Pb, respectively. The characteristic mass (m(0)) data were 24 pg As, 1.3 pg Cd, 13 pg Cu, and 35 pg Pb. The upper limits of the linear calibration range were 100, 2, 100, and 200 microg l(-1) for As, Cd, Cu, and Pb, respectively. The precisions were not worse than 4.8, 3.1, 3.7, and 2.3% for As, Cd, Cu, and Pb, respectively. For arsenic, a higher amount of the modifier (e.g., 20 microg Pd plus 12 microg Mg(NO(3))(2)) could be recommended to overcome the interference from the presence of sulphate and phosphate in wines. Although this method increased the sensitivity for As (m(0)=20 pg), it also enhanced the background noise, thus only a slight improvement in the LOD of As (3.9 microg l(-1)) was realized. For the 35 red and white wine samples studied, the highest metal contents were observed for Cu ranging from 20 to 640 microg l(-1) (average: 148 microg l(-1)), followed by Pb from 6 to 90 microg l(-1) (average: 32.3 microg l(-1)), and Cd from 0.05 to 16.5 microg l(-1) (average: 1.06 microg l(-1)), whereas the As content was below the LOD. This wide fluctuation in the trace metal content could be associated with the origin of wines from various regions (i.e., different trace metal level and/or quality of soil, and/or anthropogenic impact), and with diverse materials (e.g., additives and containers) involved in the wine production processes. The Cu content of wine samples was significantly correlated with Pb, whereas its weak anti-correlation was found with Cd. Interestingly, the level of Pb was anti-correlated with the year of production of the wines. This is likely due to the gradual decrease in the Pb content of soils of vineyards by time, which certainly causes less Pb-uptake of the grape plant, thus a decrease in the Pb content of wines as well.  相似文献   

5.
提出了用石墨炉原子吸收法测定绿色食品农田腐殖土中Pb、Cr、Cd ,以PdCl2 和NH4H2 PO4作为基体改进剂 ,经国家标准物质测定证明本法可行 .  相似文献   

6.
In this work, tetramethylammonium hydroxide (TMAH) was used to solubilize the DORM-1 dogfish muscle certified reference material as a model substance for the determination of As, Cd, Pb and Se by electrothermal atomic absorption spectrometry (ET AAS). The sample was mixed with a small amount of TMAH and heated to 60 °C for 10 min in a water bath. After dissolution, As and Se were determined using palladium and magnesium nitrates as a chemical modifier added in solution. For Cd and Pb, best results were obtained with a mixture of 250 μg of each of iridium and rhodium as permanent modifiers. In both cases, the calibration was performed with aqueous solutions in 0.2% v/v HNO3. The temperature program for each analyte was optimized using pyrolysis and atomization curves established with the fish reference material. The detection limits in dry samples and the characteristic mass values were: Cd 0.005 μg g−1 and 0.9 pg; Pb 0.04 μg g−1 and 7.6 pg; As 0.4 μg g−1 and 13 pg and Se 0.6 μg g−1 and 20 pg, respectively. Results from the determination of these elements in the DORM-1 certified fish reference material were within the 95% confidence interval of the certified values.  相似文献   

7.
A large-volume (100 microl) injection-ETAAS with W-treated PG furnace combined with a phosphate modifier was applied to the determination of unpolluted levels of Cd in tap, snow and river-water samples. The limit of detection of 1.1 ng l(-1) was observed for a 4 w/v% NH4H2PO4 modifer. Matrix interference studies were tested for major ion species well found in fresh water. The direct determination of Cd in certified river water (12 +/- 2 ng l(-1)) was carried out and the observed value was in agreement with the certified one. The good recoveries of Cd added to real environmental water samples were also observed. This method was applied to the determination of Cd in unpolluted environmental water samples.  相似文献   

8.
Bozsai G  Schlemmer G  Grobenski Z 《Talanta》1990,37(6):545-553
A graphite-furnace AAS method using the stabilized-temperature platform furnace (STPF) concept, mixed palladium and magnesium nitrates as chemical modifier and Zeeman background correction has been applied to the direct determination of As, Cd, Pb and Se in highly mineralized waters used for medicinal purposes. These contain 20-40 g/l. concentrations of salts, mainly sodium and magnesium chlorides, bicarbonates and sulphates. The use of a pre-atomization cool-down step to 20 degrees in the graphite-furnace programme reduced the background absorption. Increasing the mass of magnesium nitrate modifier to 5 times that originally proposed improved the analyte peak shape. Under these conditions, no interference was found in analysis of the chloride/bicarbonate type of water, but the sodium and magnesium sulphate type of water had to be diluted, and even then an interference remained. Calibration with matrix-free standard solutions was used, but use of spike recovery is strongly recommended for testing the accuracy. The limits of determination (4.65sigma) of the proposed method for undiluted samples are 2.0 mug/l. for As, 0.05 mug/l. for Cd, 1.0 mug/l. for Pb and 1.5 mug/l. for Se.  相似文献   

9.
Pozebon D  Dressler VL  Curtius AJ 《Talanta》2000,51(5):903-911
Isotopic dilution for the determination of Ag, Cd, Hg, Pb and Tl in biological materials by ETV-ICP-MS is proposed. The sample was simply dissolved with tetramethylammonium hydroxide (TMAH) or acid digested in a microwave furnace, with an on line matrix separation. When the dissolution was employed, Ir was used as a chemical modifier for Hg and Pb and Pd was used for Cd and Tl. No modifier was used for Ag. The pyrolysis temperatures were taken from pyrolysis temperature curves. The on line preconcentration was performed in a flow injection system with solenoid valves and was based on the analyte complexation with ammonium diethyldithiophosphate and sorption of the complexes on C(18) bonded to silica gel in a minicolumn. For the digested sample submitted to the analyte preconcentration procedure, a modifier, Ir, was only used for Hg. For the other analytes, since a low pyrolysis temperature, 300 degrees C, was employed, no modifier was added. The isotopic dilution calibration was applied to two certified materials, bovine liver and dog fish muscle, dissolved with TMAH or acid digested, and to another two certified materials, corn bran and rice flour, acid digested and submitted to analyte preconcentration. The obtained concentration values agree with the certified ones, showing that this calibration procedure leads to accurate results in the determination of low concentrations of volatile elements. Due to simplicity, the dissolution with TMAH is very attractive.  相似文献   

10.
土壤样品经硝酸、氢氟酸和过氧化氢加热消解,采用石墨炉原子吸收光谱法测定其中铅和镉的含量。以磷酸铵作为基体改进剂,铅和镉的灰化温度分别为400℃,250℃,原子化温度分别为2 100℃,1 800℃。铅和镉的质量浓度分别在0.50~50.0,0.10~2.5μg.L-1范围内与其吸光度呈线性关系,检出限依次为6.5,0.4pg。应用此法分析了4个土壤标准样品,测定值与标准值相符,相对标准偏差(n=6)分别在1.5%~6.3%和2.3%~5.1%之间。铅、镉的加标回收率分别在85.4%~103.2%,91.5%~102.3%之间。  相似文献   

11.
A method for direct determination of cadmium, chromium, copper and lead in sediments and soil samples by electrothermal atomic absorption spectrometry using Zr, Ir, etylenediamine acetic acid (EDTA), Zr + EDTA, Ir + EDTA, Zr + Ir and Zr + Ir + EDTA as chemical modifiers in 0.5% (v/v) Triton X-100 plus 0.2% (v/v) nitric acid mixture used as diluent was developed. The effects of mass and mass ratio of modifiers on analytes in sample solutions were studied. The optimum masses and mass ratios of modifiers: 20 microg of Zr, 4 microg of Ir, 100 microg of EDTA and 20 microg of Zr + 4 microg of Ir + 100 microg of EDTA, were used to enhance the analyte signals. Pyrolysis and atomization temperatures, atomization and background absorption profiles, characteristic masses, and detection limits of analytes in samples were compared in the presence or absence of a modifier. The detection limits and characteristic masses of analytes in a 0.5% (m/v) dissolved sample (dilution factor of 200 ml g(-1)) obtained with Zr + Ir + EDTA are 8.0 ng g(-1) and 1.2 pg for Cd, 61 ng g(-1) and 4.3 pg for Cr, 32 ng g(-1) and 23 pg for Cu, and 3.4 ng g(-1) and 19 pg for Pb, respectively. The Zr + Ir + EDTA modifier mixture was found to be preferable for the determination of analytes in sediment and soil-certified and standard reference materials. Depending on the sample type, the percent recoveries of analytes were increased from 81 to 103% by using the proposed modifier mixture; the results obtained are in good agreement with the certified values.  相似文献   

12.
A method for the multielement determination of cadmium and lead in urine is proposed by simultaneous electrothermal atomic absorption spectrometry (SIMAAS) with an end-capped transversely heated graphite atomizer (EC-THGA). The best conditions for cadmium and lead determination were obtained in the presence of NH4H2PO4 as a chemical modifier, using 500 degrees C and 1800 degrees C as the pyrolysis and atomization temperatures, respectively. Urine samples were diluted 1 + 4 directly in autosampler cups with a mixture of 0.125% (w/v) Triton X-100 + 2.5% (v/v) HNO3 + 0.31% (w/v) NH4H2PO4. The optimized heating program was carried out in 57 s, and the instrument calibration was done with aqueous reference solutions. The use of EC-THGA increased the sensitivity of cadmium and lead by 14% and 25%, respectively. The detection limits (n = 20, 3delta) were 0.03 microg L(-1) (0.36 pg) for cadmium and 0.57 microg L(-1) (6.8 pg) for lead. The performance of EC-THGA was acceptable up to 500 heating cycles. The reliability of the entire procedure was checked with the analysis of a lyophilized urine certified reference material. The found concentrations were in agreement with the recommended values (95% confidence level).  相似文献   

13.
A comparison between open microwave digestion and digestion by conventional heating was carried out for the determination of Cd, Cr, Cu, and Pb in two algae matrices using transverse heated electrothermal atomic absorption spectrometry (ETAAS). A SRM GBW 08504 cabbage was also analysed. These matrices were digested with HNO3, using a quartz vessel for microwave digestion and PFA vessel for digestion by conventional heating. Cd, Cu and Cr were determined without any modifier, while magnesium nitrate and ammonium phosphate mixed modifier was used for Pb. Results obtained by both the procedures were in good agreement with each other at 95% confidence level, and for SRM GBW 08504 cabbage the values agree well with the certified values. The limits of detection obtained were 0.0004, 0.060, 0.065 and 0.054 mg/kg for Cd, Cr, Cu, and Pb, respectively, using the microwave digestion process. The RSD for Cd was 10-15% and for the other elements 5-10%.  相似文献   

14.
A method for the simultaneous determination of aluminum (Al), cadmium (Cd) and lead (Pb) in whole blood has been developed by using simultaneous atomic absorption spectrometry (SIMAAS) with oxygen charring. The optimized conditions for the simultaneous determination of Al, Cd and Pb were obtained in the presence of palladium (Pd) as the chemical modifier, using 600 °C and 2400 °C as the pyrolysis and the atomization temperature, respectively. The whole blood samples were diluted 1+5 (v/v) directly with 0.1% (v/v) Triton X‐100. Oxygen was employed to eliminate the interference of carbonaceous residues in the charring step before pyrolysis. The calibration curves were carried out with aqueous standard solutions and the linear ranges were 0–40 ng mL−1, 0–4 ng mL−1 and 0–40 ng mL−1 for Al, Cd and Pb, respectively. The detection limits were 0.96 ng mL−1 (19.2 pg) for Al, 0.03 ng mL−1 (0.6 pg) for Cd and 0.60 ng mL−1 (12.0 pg) for Pb. The spiked recoveries of Al, Cd and Pb in whole blood were 98.0%, 100.0% and 101.7%, respectively. The accuracy of the proposed method was evaluated with the analysis of a whole blood certified reference material (Seronorm, level 2). The found concentrations were in agreement with the recommended values. The proposed method has been successfully applied to the simultaneous determination of Al, Cd and Pb in whole blood of healthy volunteers before and after eating barbecued foods.  相似文献   

15.
Acar O 《Talanta》2005,65(3):672-677
Cadmium, copper and lead in soils, sediments and spiked sea water samples have been determined by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background corrector using NH4NO3, Sc, Pd, Sc + NH4NO3, Pd + NH4NO3, Sc + Pd and Sc + Pd + NH4NO3 as chemical modifiers. A comprehensive comparison was made among the modifiers and without modifier in terms of pyrolysis and atomization temperatures, atomization and background absorption profiles, characteristic masses, detection limits and accuracy of the determinations. Sc + Pd + NH4NO3 modifier mixture was found to be preferable for the determination of analytes in soil and sediment certified and standard reference materials, and sea water samples because it increased the pyrolysis temperature up to 900 °C for Cd, 1350 °C for Cu and 1300 °C for Pb. Optimum masses of mixed modifier components found are 20 μg Sc + 4 μg Pd + 8 μg NH4NO3. Characteristic masses of Cd, Cu and Pb obtained are 0.6, 5.3 and 15.8 pg, respectively. The detection limits of Cd, Cu and Pb were found to be 0.08, 0.57 and 0.83 μg l−1, respectively. Depending on the solid sample type, the percent recoveries were increased up to 103% for Cd, Cu and Pb by using the proposed modifier mixture. The accuracy of the determination of analytes in the sea water samples was also increased.  相似文献   

16.
Ernst T  Popp R  van Eldik R 《Talanta》2000,53(2):347-357
Analytical data on element concentrations in plastics is an important prerequisite for the recycling of technical waste plastics. The chemical resistance and high additive contents of such materials place a high demand on analytical methods for quantifying elements in thermoplastics from electrotechnical applications. The applicability of three common independent analytical methods (EDXRF, AAS, ICP-AES) for the quantification of heavy metals in such technical waste plastics of varying composition was studied. Following specific sample pre-treatments, such as closed vessel microwave assisted digestion and wet ashing with H(2)SO(4), three hazardous metals (Pb, Cd, Sb) were determined. Conditions were investigated to minimize matrix effects for all analytical techniques employed. The trueness for the quantification of Cd was checked by using the certified reference material VDA 001-004 (40-400 mug g(-1) Cd in polyethylene), and no significant differences to certified values were found. The best detection limits were found to be 2, 1.3 and 7.9 mug g(-1) for Cd, Pb and Sb, respectively. In technical waste polymers, Sb was detected to be in the range 1-7%, Cd in the range 80-12 000 mug g(-1) and Pb in the range 90-700 mug g(-1). The precision reached for the analysis of this complex material, is comparable for all methods, and can be expressed by a relative standard deviation smaller than 8%. Application of multivariate analysis of variances (MANOVA) showed no differences between the mean results, except for the ICP-AES analysis following wet ashing with H(2)SO(4).  相似文献   

17.
Chromium, cadmium and lead were determined in different fractions of the winemaking process such as in grape, pressed pomace, must deposit, deposit of lees, must and wine. Grape, pressed pomace, must deposit and deposit of lees were digested by a high-pressure microwave-assisted digestion system with a mixture of nitric acid and hydrogen peroxide, while for must and wine no special treatment was required. The temperature programs of the graphite furnace were optimised and different matrix modifiers were applied: Mg(NO3)2, NaVO3 for Cr and NH4H2PO4, Pd(NO3)2 for Pb and Cd determinations. Mg(NO3)2 and NaVO3 thermally stabilized Cr and enabled the increase of pyrolysis temperatures up to 1500 degrees C. NH4H2PO4 and Pd(NO3)2 are suitable modifiers for Pb and allowed pyrolysis temperatures up to 800 degrees C in grape, pressed pomace and wine samples, 1100 degrees C in must samples and 1200 degrees C in deposit of lees. The non-specific background absorption of NH4H2PO4 was 1.5-2 orders of magnitude higher than that of the Pd(NO3)2.  相似文献   

18.
Lead and cadmium concentrations in sewage sludge samples are determined by suspending the ground samples in a solution containing 10% (v/v) concentrated hydrofluoric acid, 1% (v/v) concentrated nitric acid, 0.5% (m/v) dihydrogen ammonium phosphate and 0.1% (m/v) sodium hexametaphosphate. Aliquots of 20 microL of these suspensions (4 mg/mL) are diluted to 1000 microL with the same solution and then injected into the electrothermal atomizer. The drying stage is performed by programming a 400 degrees C temperature, a ramp time of 20 s and a hold time of 15 s on the power supply of the atomizer. No ashing step is used. Platform atomization is carried out at 1600 and 1800 degrees C for Pb and Cd, respectively. Calibration is performed using aqueous standards in the 5-75 and 0.2-5 microg/L Pb and Cd ranges, respectively. Results obtained for three certified reference materials and four samples demonstrate the reliability of the procedures described.  相似文献   

19.
A method for determination of manganese and selenium in serum by simultaneous atomic absorption spectrometry (SIMAAS) is proposed. The samples (30 mul) were diluted (1+3) to 1.0% v/v HNO(3)+0.10% w/v Triton X-100 directly in the autosampler cups. A total of 20 mug Pd+10 mug Mg(NO(3))(2) was used as chemical modifier. The pyrolysis and atomization temperatures for the simultaneous heating program were 1200 and 2300 degrees C, respectively. The addition of an oxidant mixture (15% w/w H(2)O(2)+1.0% v/v HNO(3)) and the inclusion of a low temperature pyrolysis step (400 degrees C) attenuated the build-up of carbonaceous residues onto the integrated platform. An aliquot of 15 mul of the reference or sample solution was introduced into the graphite tube and heated at 80 degrees C; subsequently, 10 mul of oxidant mixture+10 mul of chemical modifier was introduced over that aliquot and the remaining heating program steps were executed. This strategy allowed at least 250 heating cycles for each THGA tube without analytical signal deterioration. The characteristic masses for manganese (6 pg) and selenium (46 pg) were estimated from the analytical curves. The detection limits were 6.5 pg (n=20, 3delta) for manganese and 50 pg (n=20, 3delta) for selenium. The reliability of the entire procedure was checked with the analysis of serum from Seronormtrade mark Trace Elements in Serum (Sero AS) and by addition and recovery tests (97+/-9% for manganese and 96+/-7% for selenium) using five serum samples.  相似文献   

20.
A comparison between open microwave digestion and digestion by conventional heating was carried out for the determination of Cd, Cr, Cu, and Pb in two algae matrices using transverse heated electrothermal atomic absorption spectrometry (ETAAS). A SRM GBW 08504 cabbage was also analysed. These matrices were digested with HNO3, using a quartz vessel for microwave digestion and PFA vessel for digestion by conventional heating. Cd, Cu and Cr were determined without any modifier, while magnesium nitrate and ammonium phosphate mixed modifier was used for Pb. Results obtained by both the procedures were in good agreement with each other at 95% confidence level, and for SRM GBW 08504 cabbage the values agree well with the certified values. The limits of detection obtained were 0.0004, 0.060, 0.065 and 0.054 mg/kg for Cd, Cr, Cu, and Pb, respectively, using the microwave digestion process. The RSD for Cd was 10–15% and for the other elements 5–10%.  相似文献   