首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
碳糊电极阳极吸附伏安法测定洛美沙星   总被引:3,自引:0,他引:3  
报道了碳糊电极阳极吸附伏安法测定洛美沙星的新方法。在0.096mol L的KHP NaOH(pH5.4)缓冲液中,用碳糊电极为工作电极,在0.3V(vs.SCE)富集一定时间,然后从0.3~1 3V以300mV s扫速线性扫描,记录其在1 02V的二次导数阳极溶出峰。溶出峰电流与洛美沙星浓度在8.0×10-9~8.0×10-8mol L(富集90s)和8.0×10-8~8.0×10-7mol L(富集30s)范围内呈良好的线性关系,相关系数分别为0.9844和0.9967,检出限为9.0×10-10mol L(S N=3)。探讨了洛美沙星在碳糊电极上的伏安性质和电极反应机理,并且成功地应用于人体尿液中洛美沙星的测定,结果与紫外光度法基本吻合。  相似文献   

2.
A novel and sensitive electrochemical sensor based on porous pseudo-carbon paste electrode (PPCPE) for tannic acid detection is described. PPCPE is fabricated by mixing calcium carbonate microspheres as the template, graphite powders as the filler, and pyrrole as the precursor of polymer which actually acted as the paste. After the polymerization of pyrrole catalyzed by Fe3+, the template calcium carbonate microspheres are removed with 0.1 M hydrochloric acid to form PPCPE. The diameters of these pores are in the range from 2 to 5 μm by SEM observations and the specific surface area of PPCPE is 59.26 m2/g by the Brunauer–Emmet–Teller (BET) method. A linear relationship between the anodic stripping peak current and the concentration of tannic acid from 0.02 to 1 μM and a limit of detection as low as 0.01 μM are obtained using PPCPE.  相似文献   

3.
A sensitive method is described for the determination of trace bismuth based on the bismuth-bromopyrogallol red (BPR) adsorption at a carbon paste electrode (CPE). The overall analysis involved a three-step procedure: accumulation, reduction, and anodic stripping. Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, a 0.30 mol l−1 HCl solution containing 2.0×10−5 mol l−1 BPR as supporting medium; accumulation potential and time, −0.10 V, 3 min; reduction potential and time, −0.35 V, 60 s; scan rate 100 mV s−1; scan range from −0.35 to 0.15 V. It was found that the Bi(III)-BPR complex could be accumulated on the electrode surface during the accumulation period. Then the Bi(III) in the Bi(III)-BPR complex on the CPE surface was reduced to Bi(0) during reduction interval and finally reoxidized during the anodic stripping step for voltammetric quantification. Factors affecting the accumulation, reduction, and stripping steps were investigated. Interferences by other ions were studied as well. The detection limit was found to be 5×10−10 mol l−1 with a 3 min accumulation time. The linear range was from 1.0×10−9 to 5.0×10−7 mol l−1. Application of the procedure to the determination of bismuth in water and human hair samples gave good results.  相似文献   

4.
This work reports the use of and -cyclodextrin-modified carbon paste electrodes (CPE-CD and CPE-CD) to determine simultaneously Pb(II) and Cd(II) by means of the electrochemical technique known as anodic stripping voltammetry (ASV). Both modified electrodes displayed good resolution of the oxidation peaks of the said metals. Statistic analysis of the results strongly suggests that the CPE-CD exhibited a better analytical response that the CPE-CD, while the detection limits obtained for Pb(II) were 6.3×10–7 M for the CPE-CD and 7.14×10–7 M for the CPE-CD, whereas for Cd(II) they were 2.51×10–6 M for the CPE-CD and 2.03×10–6 M for the CPE-CD.  相似文献   

5.
碳糊修饰电极吸附伏安法测定食品中的锑   总被引:3,自引:0,他引:3  
研制了溴邻苯三酚红 (BPR)作修饰剂的碳糊修饰电极 ,并用此电极作工作电极建立了测定痕量锑的吸附伏安法。在选定的实验条件下 ,峰电流与Sb(Ⅲ )浓度在 8.0× 1 0 -9~ 2 .0× 1 0 -7mol L范围内呈线性关系 ,检出限为 2 .0×1 0 -9mol L ,1 0次测定相对标准偏差为 2 .0 % ,不用分离 ,可直接测定食品中痕量Sb(Ⅲ ) ,测定的回收率为 90 %~ 1 0 3%。  相似文献   

6.
Radi A  El-Sherif Z 《Talanta》2002,58(2):319-324
The adsorption behavior of levofloxacin on a glassy carbon electrode was explored by cyclic and square-wave voltammetry. The drug was accumulated on a glassy carbon electrode and a well-defined oxidation peak was obtained in acetate buffer pH 5.0. Using square-wave anodic stripping voltammetry and accumulation at +0.4 V versus Ag/AgCl (saturated KCl) for 300 s, linear calibration graph was obtained from 6.0x10(-9) to 5.0x10(-7) M levofloxacin. The detection limit was calculated to be 5.0x10(-9) M. The R.S.D. determined from ten determinations at the 1.0x10(-7) M level was 1.7%. The method was applied for the direct determination of levofloxacin in diluted urine samples. It was validated using high-performance liquid chromatography (HPLC) as a reference method.  相似文献   

7.
The electrochemical behavior of vardenafil HCl (VRL) at a carbon paste electrode (CPE) was investigated by cyclic voltammetry, and the mechanism of its oxidation was suggested and discussed. A simple Nujol-based CPE in combination with a sensitive square-wave adsorption anodic stripping voltammetry method was described for trace determination of VRL. The described method showed excellent performance for trace determination of VRL in its formulation “Levitra® tablets” without interference from excipients. The results were statistically compared with those obtained with an established HPLC method; nonsignificant differences were found between the described voltammetric and HPLC methods. The described stripping voltammetric method is highly sensitive (limit of detection?=?3?×?10?10?mol?L?1 and limit of quantitation?=?1?×?10?9?mol?L?1). It was successfully applied for the determination of VRL in spiked human serum without the necessity for pretreatment and/or time-consuming extraction steps prior to the analysis.  相似文献   

8.
In this work, an antimony trioxide-modified multi-walled carbon nanotube paste electrode (Sb2O3/CNTPE) was employed for determination of Cu2+ ions by using square wave anodic stripping voltammetry (SWASV) in the presence of 8-hydroxy-7-iodo-5-quinoline sulfonic acid (HIQSA) as a chelating agent. The field emission scanning electron microscopy (FE-SEM), energy-dispersive spectroscopy (EDS) and electrochemical impedance spectroscopy (EIS) methods were applied to estimate the morphology and properties of the modified electrode. Measurements related to SWASV were taken in 0.6 M HCl at ?1.0 V versus Ag|AgCl|KCl (3 M) for 90 s (deposition step). After equilibrium time of 15 s, an ASV appeared at 0.0 V versus Ag|AgCl|KCl (3 M) (stripping step). The sensor depicted a fairly linear response for Cu2+ in the concentration range of 2–100 ppb with appropriate detection limit about 0.39 ppb and limit of quantification about 1.3 ppb. The stability of the modified electrode during 7 weeks and its behavior in the presence of some metal ions was evaluated. The practical applicability of the Sb2O3/CNTPE was established on the voltammetric determination of Cu2+ in tap water as a sample.  相似文献   

9.
建立了一种测定痕量铋的新方法,即利用掺杂硒碳糊电极作为工作电极的阳极溶出法.在0.1 mol/L的HCl底液中,Bi3+于+0.05V(vs.Ag/AgCl)出现灵敏的氧化溶出峰,铋离子的浓度在1.0×10-5~1.0×10-9 mol/L范围内其对数值lgc与铋的氧化峰电流值呈线性关系,检出限达1.0×10 -10 ...  相似文献   

10.
11.
Hwang GH  Han WK  Park JS  Kang SG 《Talanta》2008,76(2):301-308
A bismuth-modified carbon nanotube electrode (Bi-CNT electrode) was employed for the determination of trace lead, cadmium and zinc. Bismuth film was prepared by in situ plating of bismuth onto the screen-printed CNT electrode. Operational parameters such as preconcentration potential, bismuth concentration, preconcentration time and rotation speed during preconcentration were optimized for the purpose of determining trace metals in 0.1M acetate buffer solution (pH 4.5). The simultaneous determination of lead, cadmium and zinc was performed by square wave anodic stripping voltammetry. The Bi-CNT electrode presented well-defined, reproducible and sharp stripping signals. The peak current response increased linearly with the metal concentration in a range of 2-100 microg/L. The limit of detection was 1.3 microg/L for lead, 0.7 microg/L for cadmium and 12 microg/L for zinc (S/N=3). The Bi-CNT electrode was successfully applicable to analysis of trace metals in real environments.  相似文献   

12.
13.
The adsorptive and electrochemical behaviors of medecamycin were investigated on a glassy carbon electrode (GCE) pretreated by anodic oxidation at +1.8 V for 5 min in 0.025 mol l–1 NH3-NH4Cl (pH 8.6) solution. An adsorptive stripping voltammetric method for the determination of medecamycin at the pretreated glassy carbon electrode has been developed. Medecamycin was accumulated in NH3-NH4Cl buffer (pH 9.0) at a potential of –0.7 V (vs. saturated calomel electrode (SCE)) for a certain time, and then determined by second-order differential anodic stripping voltammetry. The second-order differential anodic stripping peak current at +0.72 V was proportional to the concentration of medecamycin in the range 2.0 g ml–1 to 50.0 g ml–1. The detection limit (three times the signal-to-noise) was 1.0 g ml–1 and the relative standard deviation of the results was 3.28% for eight successive determinations of 10.0 g ml–1 medecamycin. This method has been applied to the direct determination of medecamycin in commercial tablets and spiked urine samples with satisfactory results.  相似文献   

14.
Gazy AA 《Talanta》2004,62(3):575-582
The adsorptive and electrochemical behavior of amlodipine besylate on a glassy carbon electrode were explored in Britton-Robinson buffer solution by using cyclic and square-wave voltammetry. Cyclic voltammetric studies indicated the oxidation of amlodipine besylate at the electrode surface through a single two-electron irreversible step and fundamentally controlled by adsorption. The solution conditions and instrumental parameters were optimized for the determination of the authentic drug by adsorptive square-wave stripping voltammetry. Amlodipine besylate gave a sensitive adsorptive oxidation peak at 0.510 V (versus Ag/AgCl). The oxidation peak was used to determine amlodipine besylate in range 4.0×10−8 to 2.0×10−6 with a detection limit of 1.4×10−8 M. The procedure was successfully applied for the assay of amlodipine besylate in tablets (Norvasc)®. The percentage recoveries were in agreement with those obtained by the reference method. Applicability to assay the drug in urine and serum samples was illustrated. The mean percentage recoveries were 96.31±1.18 and 96.98±1.17, respectively. The proposd method used for monotoring clinically relevant concntrations of drug in human urine and serum.  相似文献   

15.
Wang Z  Zhang H  Zhou S  Dong W 《Talanta》2001,53(6):1133-1138
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum.  相似文献   

16.
The antihypertensive drug amlodipine has been characterized voltammetrically in a carbon paste electrode by means of anodic stripping voltammetry. An adsorptive stripping method in a carbon paste electrode for trace determination of amlodipine has been described. Cyclic voltammetric studies indicated the oxidation of amlodipine besylate at the electrode surface through a single two-electron irreversible step fundamentally controlled by adsorption. A study of the variation in the peak current with solution variables such as pH, ionic strength, concentration of amlodipine, possible interference, and instrumental variables, such as preconcentration time and accumulation potential, has resulted in the optimization of the oxidation signal for analytical purposes. By anodic adsorptive anodic stripping voltammetry, the calibration plot was linear in the range 9.9 × 10?9 ? 1.4 × 10?7 M with a detection limit of 2 × 10?10 M in a carbon paste electrode at pH 11.0. The procedure was successfully applied to the assay of amlodipine besylate in some commercial products in the market (Amlopres®, Amlodipine, and Norvasc®). The percentage recoveries were in agreement with those obtained by the reference method.  相似文献   

17.
A rotating mercury-plated reticulated vitreous carbon (RVC) electrode is tested for square-wave anodic stripping voltammetry; RVC provides very large surface areas which are easily plated with mercury. Despite the ill-defined geometry of the electrode, the square-wave stripping peaks are very well defined; their behaviour conforms partly to known theory for square-wave stripping from mercury film electrodes. Fast analytical determinations of lead and cadmium in the μg l?1 range are facilitated by the high efficiency of the preconcentration step and the high sensitivity given by the stripping waveform.  相似文献   

18.
An adsorptive stripping voltammetric procedure for the determination of U(VI) at an in situ plated lead film electrode is described. The U(VI) complex with cupferron was accumulated from an acetate buffer solution of pH 4.2 at the potential −0.65 V. The measurements were carried out from undeaerated solutions. The calibration graph for an accumulation time of 180 s was linear from 5 × 10−10 to 2 × 10−8 mol L−1. The detection limit was 2 × 10−10 mol L−1, the relative standard deviation for 2 × 10−8 mol L−1 U(VI) was 4.3%. The proposed procedure was validated in the course of U(VI) determination in water certified reference materials.  相似文献   

19.
An adsorptive stripping voltammetric method for the determination of the pesticide dinoseb (2-sec.-butyl-4,6-dinitrophenol) at the mercury film electrode is described. The deposition of the mercury film on a glassy carbon disk electrode was optimized. The temperature, at which the mercury film was deposited, was demonstrated to have a strong influence on the stripping peaks, the first one being much more intense than the second. A systematic study of the variables affecting the stripping response was carried out by differential pulse voltammetry. The results obtained have been compared with those at the HMDE; a significant improvement in the sensitivity of the method developed with the MFE was observed. Using a 300 s accumulation time, the limits of determination and detection were 3.6 × 10–10 and 1.1 × 10–10 mol L–1, respectively. The effect of the presence of several herbicides on the dinoseb response was also tested. The method has been applied to the determination of the pesticide in spiked apple juice at two concentration levels: 12.0 and 1.2 g L–1 of juice.  相似文献   

20.
制备了茜素红S/多壁碳纳米管修饰碳糊电极,提出了一种灵敏的溶出伏安法测定痕量铜的新方法.在极谱分析仪上采用二阶导数线性扫描伏安法进行分析,在0.1 moL/L的HAc-NaAc缓冲溶液(pH 4.1)中,Cu与修饰电极表面的茜素红S(ARS)形成Cu(Ⅱ)-ARS络合物而富集于电极表面,于-400 mV处还原后,再进行阳极化扫描,于64 mV处获得一灵敏的铜的阳极溶出峰,峰电流与Cu(Ⅱ)浓度在2×10-11 mol/L~6×10-7 mol/L范围内呈良好的线性关系,检出限(S/N=3) 为8.0×10-12 mol/L(富集时间240 s).方法应用于人发中铜含量的测定,回收率为98%~102%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏