首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
 Adsorptive accumulation of the Pd(II) complex with dimethylglyoxime was evaluated for stripping voltammetry with respect to different parameters. The sensitivity of the method and the linearity between the peak current and the concentration of Pd(II) depends on the ionic strength, the electrode area, the preconcentration time, the transport rate to the electrode, and the potential scan rate. The most appropriate medium was 0.1 mol/L acetate buffer between pH 3.5 and 4. Using 2 min of preconcentration at a 2.6 mm2 electrode and the differential pulse mode, a detection limit of 0.05 μg/L Pd was achieved for liquid samples and 50 ng/g for solid samples. Different aqueous and solid samples were analysed and the recovery from biological and inorganic materials investigated. Received: 29 February 1996/Revised: 29 July 1996/Accepted: 1 August 1996  相似文献   

2.
The adsorption behavior and differential pulse cathodic adsorptive stripping voltammetry of the pesticide Chlorpyrifos (CP) were investigated at the hanging mercury drop electrode (HMDE). The pesticide was accumulated at the HMDE and a well-defined stripping peak was obtained at –1.2 V vs Ag/AgCl electrode at pH 7.50. A voltammetric procedure was developed for the trace determination of Chlorpyrifos using differential pulse cathodic adsorptive stripping voltammetry (DP-CASV). The optimum working conditions for the determination of the compound were established. The peak current was linear over the concentration range 9.90 × 10–8– 5.96 × 10–7 mol/L of Chlorpyrifos. The influence of diverse ions and some other pesticides was investigated. The analysis of Chlorpyrifos in commercial formulations and treated waste water was carried out satisfactorily  相似文献   

3.
The adsorption behavior and differential pulse cathodic adsorptive stripping voltammetry of the pesticide Chlorpyrifos (CP) were investigated at the hanging mercury drop electrode (HMDE). The pesticide was accumulated at the HMDE and a well-defined stripping peak was obtained at –1.2 V vs Ag/AgCl electrode at pH 7.50. A voltammetric procedure was developed for the trace determination of Chlorpyrifos using differential pulse cathodic adsorptive stripping voltammetry (DP-CASV). The optimum working conditions for the determination of the compound were established. The peak current was linear over the concentration range 9.90 × 10–8– 5.96 × 10–7 mol/L of Chlorpyrifos. The influence of diverse ions and some other pesticides was investigated. The analysis of Chlorpyrifos in commercial formulations and treated waste water was carried out satisfactorily Received: 10 July 1997 / Revised: 1 April 1998 / Accepted: 6 April 1998  相似文献   

4.
A procedure is presented for determining Se(IV) and total dissolved Se in sea water using cathodic stripping voltammetry in the presence of added copper. Experiments using cyclic voltammetry indicate that the preconcentration step consists in adsorption of a Cu(I)2Se complex species on the hanging mercury drop electrode. The optimized analytical conditions include a copper concentration of 40 μM and a solution pH of 1.6. Differential pulse modulation is used. Interference caused by organic surface-active substances present in natural waters in eliminated by UV photolysis of the sample. Cadmium interferes with the determination of Se only when present at a concentration 100 times higher than normal. UV photolysis at pH ≈ 8 is used to convert Se(VI), which is the electroactive species. The response is linear for Se concentrations between 0 and 200 nM. The limit of detection is 0.01 nM Se when a deposition time of 15 min is used.  相似文献   

5.
Opydo J 《Talanta》1997,44(6):1081-1086
This paper presents a method of determination of aluminium in tree samples (wood, leaves, roots) based on the cathodic adsorptive stripping voltammetry. Al(III) complexed with alizarin S was determined by ASV method using a hanging mercury drop electrode. Optimal conditions were found to be: accumulation time 30-90 s, accumulation potential - 0.70 V versus SCE, supporting electrolyte 0.1 M ammonia-ammonium chloride buffer at pH 8.2 and concentration of alizarin 1 x 10(-5) M. The response of the system, a linear current-concentration relationship was observed up to 8 x 10(-6) M. The developed method has been tested by analysing international reference materials (BCR 62 Olive leaves and BCR 101 spruce needles).  相似文献   

6.
This article describes the determination of Eu by adsorptive cathodic stripping voltammetry after complexation with N-nitroso-N-phenylhydroxylamine (cupferron). The accumulation of the complex at the HMDE was performed at 0.0 V and the subsequent potential scan was made in the square wave mode. The analyte signal occurred at −0.88 V. The detection limit is 0.06 nmol dm−3. The effect of instrumental and chemical parameters on the peak height and potential was investigated. The same technique can be used for the determination of ytterbium and of the other rare earth elements (REEs) after separation.  相似文献   

7.
Guanine is determined at the 5.0×10–10 –2.0×10–7 mol/l level by differential-pulse adsorptive stripping voltammetry at a hanging mercury drop electrode using the reduction peak of its copper (II) complex at –0.21 V vs. Ag-AgCl electrode. The optimum analytical conditions were found to be Britton-Robinson buffer solution (pH 4.8), an accumulation potential of 0.0 V and an accumulation time of 3 min. Under these conditions, the detection limit is 5.0×10–10 mol/l and the relative standard deviation 2.6% for 1.0×10–7 mol/l guanine. The method is compared with the previous voltammetric methods. The presence of some purine derivatives does not interfere.  相似文献   

8.
A square-wave cathodic adsorptive stripping voltametric (SWCASV) method for the determination of kanamycin was developed on a thin-film mercury electrode (TFME). The optimal working conditions for the application of the method were found to be pH 8.0, provided by a Britton-Robinson (B.R.) buffer, and an adsorption potential of +0.30 V during 300 s. The equilibration time was applied during 10 s, and potential scans were performed at a scan rate of 40 mV/s, with a square-wave frequency of 100 Hz. The measuring-system response was linear over the kanamycin concentration range from 1.2 × 10−9 to 5.0 × 10−8 M and the detection limit achieved was 4.8 × 10−10 M. The relative error and relative standard deviation obtained were 1.20 and 4.67%, respectively. The voltammetric procedure was applied successfully to give a rapid and precise assay of kanamycin in kanamycin sulfate injection form. Published in Elektrokhimiya in Russian, 2008, Vol. 44, No. 12, pp. 1433–1437. The text was submitted by author in English  相似文献   

9.
An electrochemical method has been developed for the detection and determination of 2-amino-5-nitrothiazole (2,5-ANT) by adsorption square-wave voltammetric stripping. The best sensitivity/resolution ratio was obtained by adsorption at pH 8.0 using a phosphate buffer, an accumulation potential of –10 mV (vs. Ag/AgCl 3 mol/l) and an accumulation time of 15 s. Under these conditions, the proposed method provides a linear electrode response over the 2,5-ANT concentration range 5–300 ng ml–1, and a detection and determination limit of 4 and 7.5 ng ml–1, respectively. The method was applied to the determination of 2,5-ANT in bacon.  相似文献   

10.
Molybdenum is determined by adsorptive cathodic stripping voltammetry in 0.15 M nitric acid solution containing 15 μM 2′,3,4′,5,7-pentahydroxyflavone (morin) as a ligand. In this medium, molybdenum is preconcentrated on a hanging mercury drop electrode and stripped cathodically in square-wave voltammetry mode, with a peak potential of -350 mV vs. Ag/AgCl (saturated KCl). The effect of various parameters (ligand concentration, supporting electrolyte composition, accumulation potential and collection time) on the sensitivity and linear range of the calibration curve are discussed. With controlled accumulation for 1 min, the detection limit (3σ) was 0.45 ng ml?1 molybdenum and the calibration curve is linear up to 70 ng ml?1. The procedure is applied to the determination of molybdenum in real samples with satisfactory results.  相似文献   

11.
A selective and sensitive stripping voltammetric method for the determination of trace amounts of copper(II) with a recently synthesized naphthol-derivative Schiff's base (2,2'-[1,2-ethanediylbis(nitriloethylidyne)]bis(1-naphthalene)) is presented. The method is based on adsorptive accumulation of the resulting copper-Schiff's base complex on a hanging mercury drop electrode, followed by the stripping voltammetric measurement at the reduction current of adsorbed complex at -0.15 V (vs. Ag/AgCl). The optimal conditions for the stripping analysis of copper include pH 5.5 to 6.5, 8 microM Schiff's base and an accumulation potential of -0.05 V (vs. Ag/AgCI). The peak current is linearly proportional to the copper concentration over a range 2.3-50.8 ng ml(-1) with a limit of detection of 1.9 ng ml(-1). The accumulation time and RSD are 90 s and (3.2-3.5)%, respectively. The method was applied to the determination of copper in some analytical grade salts, tap water, human serum and sheep's liver.  相似文献   

12.
In this work, a simple and sensitive electroanalytical method was developed for the determination of enrofloxacin (ENRO) by adsorptive cathodic stripping voltammetry (ADSV) using Cu(II) as a suitable probe. The complex of copper(II) with ENRO was accumulated at the surface of a hanging mercury drop electrode at −0.10 V for 40 s. Then, the preconcentrated complex was reduced and the peak current was measured using square wave voltammetry (SWV). The optimization of experimental variables was conducted by experimental design and support vector machine (SVM) modeling. The model was used to find optimized values for the factors such as pH, Cu(II) concentration and accumulation potential. Under the optimized conditions, the peak current at −0.30 V is proportional to the concentration of ENRO over the range of 10.0-80.0 nmol L−1 with a detection limit of 0.33 nmol L−1. The influence of potential interfering substances on the determination of ENRO was examined. The method was successfully applied to determination of ENRO in plasma and pharmaceutical samples.  相似文献   

13.
The electrochemical reduction of secnidazole was carried out in BR buffer solutions in the pH range 2.0–11.8 by dc polarography. The polarograms exhibited two irreversible reduction waves in acidic media and one wave in alkaline media, corresponding to the reduction of nitro group in the drug. The cathodic adsorptive voltammetric behavior was studied on glassy carbon electrode to optimize an analytical method for determination of secnidazole. The drug was determined in the range between 4.0 × 10?6 and 1.2 × 10?4 mol L?1. The proposed method was successfully applied to the determination of the drug content in tablets with mean recovery and relative standard deviation of 100.91% and 1.82%, respectively. It was also applied to human serum with a good precision and accuracy.  相似文献   

14.
Trace amounts of thallium(I) can be determined using adsorptive cathodic stripping voltammetry in the presence of Xylenol Orange (XO). The reduction current of the thallium(I)-XO complex ion was measured by square-wave cathodic stripping voltammetry. The peak potential was at -0.44 V vs. Ag/AgCl. The effect of various parameters (pH, ligand concentration, accumulation potential and collection time) on the response are discussed. The response was linearly related to the thallium concentration in the range 0.5-110 ng ml(-1) and 110-2000 ng ml(-1). The limit of detection was 0.2 ng ml(-1). The relative standard deviation for the determination of 80 ng ml(-1) thallium was 2.8%. Many common anions and cations did not interfere with the determination of thallium. The interference of lead was reduced by the addition of 0.003 M sodium carbonate. The voltammetric procedure was then successfully applied to the determination of thallium in various complex samples.  相似文献   

15.
A voltammetric method for the determination of 3-mercapto-D-2-methylpropanoyl-L-proline, a hypotensive drug whose pharmaceutical name is Captopril (CPT), in the concentration range from 9.0×10−10M to 3×10−6M, is described. In this range the peak current increases linearly with drug concentration even when different collection periods are used. A self-cleaning Hanging Mercury Drop Electrode (HMDE) was used and a negative Differential Pulse potential (DP) was applied to the indicator electrode. The stripping peak of CPT splits into two peaks as soon as the concentration is increased over about 10−5M; in the oxidation DP scan, instead, this splitting is observed at a concentration of 2.0×10−4M. Some attempts were made to verify the suitability of other techniques such as Alternating Current polarography (AC) and the use of a different electrode, the Wax-Impregnated Graphite Electrode (WIGE).  相似文献   

16.
Cha KW  Park CI  Park SH 《Talanta》2000,52(6):689-989
Uranium(VI) complexed with aluminon (3-[bis(3-carboxy-4-hydroxy-phenyl)methylene]-6-oxo-1,4-cyclohexadiene-1-carboxylic acid triammonium salt) was determined by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode. Trace uranium(VI) and zinc(II) can be simultaneously determined in a single scan in the presence of aluminon and urea. Optimal conditions were found to be: accumulation time; 180–200 s, accumulation potential; 50 mV versus Ag/AgCl, scan rate; 40 mV s−1, supporting electrolyte; 0.1 M sodium acetate buffer at pH 6.5–7.0, and concentration of aluminon; 1×10−6 M. The linear range of uranium(VI) and zinc(II) were observed over the concentration range 2–33 and 30–120 ng ml−1, respectively. The detection limit (S/N=3) are 0.2 ng ml−1 (uranium) and 30 ng ml−1 (zinc). A good reproducibility shows RSDs of 2.5–4.0% (n=10). The procedure offers high selectivity, with the presence of urea masking some metal ions.  相似文献   

17.
A procedure for the determination of gallium by differential pulse adsorptive stripping voltammetry (DPADSV), using different complexing agents (ammonium pyrrolidine dithiocarbamate (APDC), pyrocatechol violet (PCV) and diethyldithiocarbamate (DDTC)), has been optimized. The selection of the experimental conditions was made using experimental design methodology. Under these conditions, the calibration was made and the detection limit was determined for each gallium-ligand complex. A robust regression method was applied which allowed the elimination of anomalous points. The detection limit, with α=β=0.05, for gallium-APDC complex was 5.0×10−8 mol dm−3, for gallium-PCV complex was 9.9×10−9 mol dm−3, and the lowest detection limit (1.3×10−9 mol dm−3) was obtained with DDTC. For this reason, DDTC was selected for the determination of the gallium concentration in a certificate sample and in a spiked tap water sample. The linear dynamic range for gallium-APDC complex was from 5.0×10−8 to 2.7×10−7 mol dm−3, for gallium-PCV complex was from 5.0×10−9 to 4.8×10−7 mol dm−3, and for gallium-DDTC complex was from 1.0×10−9 to 2.1×10−7 mol dm−3.  相似文献   

18.
Trichlorobiphenyl is determined in the concentration range 0.004–1 mg l?1 by adsorptive stripping voltammetry at a hanging mercury drop electrode. Preconcentration is achieved by adsorption at a potential of ?0.40 (V (vs. Ag/AgCl), and desorption at ?1.10 V. Biphenyl interferes with the determination only when present in 5-fold molar amounts compared to trichlorophenyl. The interference of DDT is eliminated by prior treatment of the sample solution with sulphuric acid. The method was applied for the analysis of waste and natural waters, the relative standard deviation being <5%.  相似文献   

19.
A very sensitive electrochemical stripping procedure for azinphos-methyl (Guthion) is reported. Accumulation is achieved by adsorption of the compound on a hanging mercury drop electrode. The adsorptive stripping response was evaluated with respect to accumulation time and potential, concentration dependence, electrolyte and other variables. The determination limit is 0.2 ng ml?1 after 300 s accumulation and 0.4 ng ml?1 after 180 s accumulation. The procedure was applied to spiked river water.  相似文献   

20.
A voltammetric method for the determination of uranium in natural waters in the concentration range from 0.4 μg 1−1 to 0.2 mg 1−1 is described. The method is based on adsorptive accumulation of the uranium(VI)—pyrocatechol complex on the hanging mercury drop electrode followed by the reduction of the absorbed complex.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号