首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new ammonia optical sensor was designed using bis(acetylacetoneethylendiamine)tributylphosphin cobalt(III) tetraphenylborate complex, coated on transparent triacetylcellulose film as membrane. The change in the absorbance of the optode at the maximum wavelength of 408 nm was related to ammonia concentration in aqueous samples. A buffer solution with a pH of 9 (sodium borate-HCl) was used. The optode was fully regenerated in pH 2. The linear dynamic range for determination of ammonia was 3.3 x 10(-4) to 6.9 x 10(-3) mol l(-1) with a detection limit of 5.0 x 10(-5) mol l(-1) and a response time range of 4 - 6 min. This membrane was successfully applied for determination of ammonia in drinking water.  相似文献   

2.
An aminobenzanthrone Schiff base has been synthesized as a new fluorescence carrier for the preparation of an optical chemical sensor for iodine. The response of the sensor is based on fluorescence quenching of the aminobenzanthrone Schiff base by iodine. The sensor shows a linear response toward iodine in the range of 1.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), with a detection limit of 6.0 x 10(-6) mol l(-1) at pH 8.0. Leaching of the fluorophore from the membrane is effectively hindered by covalent immobilization, resulting in an enhanced sensor lifetime. In addition to satisfactory reproducibility and reversibility, the prepared sensor exhibits sufficient selectivity toward iodine with respect to other coexisting ions. The sensor has been applied to the determination of iodine in common salt samples.  相似文献   

3.
Diffusion coefficient measurements in microfluidic devices   总被引:2,自引:0,他引:2  
A glassy carbon electrode (GCE) modified with Pd/IrO(2) provides excellent electrocatalytic oxidation of hydrogen peroxide. Glucose oxidase (GOD) and xanthine oxidase (XOD) were co-immobilized on the modified electrode with a thin film Nafion coated on the enzyme layer to form a glucose (Glu)/hypoxanthine (Hx) sensor, without interference from electroactive species such as ascorbic acid (AA) and uric acid (UA). Its response was evaluated with respect to the enzyme amount on the electrode, pH and temperature of the electrolyte. The prepared bienzymic biosensor, used as the detector of HPLC gave a detection limit of 1.0x10(-6) mol l(-1) Glu and 2.0x10(-7) mol l(-1) Hx (Hx) with a linear concentration range of 5.0x10(-6)-2.5x10(-3) mol l(-1) and 1.0x10(-6)-5.0x10(-4) mol l(-1), respectively. Coupled with microdialysis, it was used to monitor the concentrations of Glu and Hx in rat brain.  相似文献   

4.
Tütem E  Apak R  Günaydı E  Sözgen K 《Talanta》1997,45(2):249-255
A coated graphite-epoxy ion-selective electrode for bismuth(III), based on the ion-pair between the [Bi(EDTA)](-) anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated onto a poly(vinylchloride) (PVC) matrix is constructed. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) or ortho-nitrophenyloctylether (o-NPOE) in PVC was deposited directly onto a Perspex(R) tube which contained a graphite-epoxy conductor substrate attached to the end of a glass tube. The coating solution was prepared by dissolving 30% (w/w) of PVC in 10 ml of tetrahydrofuran following addition of 65% (w/w) DBPh or o-NPOE and 5% (w/w) of the ionic pair. The effect of pH, EDTA concentration and some cation and anion on the electrode response is investigated. The bismuth(III) ion-selective electrode shows a linear response in the bismuth(III) concentration range from 1.0 x 10(-8) to 1.0 x 10(-1) mol 1(-1) and 1.0 x 10(-7) to 1.0 x 10(-1) mol 1(-1) and a slope of 56.8 and 59.2 mV dec.(-1) for the polymeric membranes containing DBPh and o-NPOE, respectively. The lifetime of this electrode was superior to 1 year (over 1600 determinations for each polymeric membrane), with practical detection limits of 6.3 x 10(-9) and 4.4 x 10(-8) mol 1(-1) with these plasticizers. Application of this electrode with bismuth(III) determination in a stomach anti-acid sample is described.  相似文献   

5.
以利巴韦林为模板分子,甲基丙烯酸为功能单体,采用沉淀聚合法制备利巴韦林分子印迹聚合物(MIP).以利巴韦林分子印迹聚合物掺杂氧化石墨烯(GO)为离子载体,聚氯乙烯为基质,癸二酸二辛酯为增塑剂制备电极敏感膜.结果表明,敏感膜组成为100.8 mg MIP、14.7 mg GO、450.8 mg聚氯乙烯和901.6 mg癸二酸二辛酯,内充液组成为0.1 mol/L NaCl+0.05 mol/L NaAc-0.05 mol/L HAc缓冲溶液+ 1.0×10.-5 mol/L利巴韦林,电极的响应性能最好.此电极的能斯特响应斜率为45.565 mV/decade,线性范围为1.0×10.-6~1.0×10.-4 mol/L, 检出限为1.0×10.-7 mol/L(S/N=3),工作pH范围为3~5,响应时间小于3 min.此电极对利巴韦林具有高选择性,可用于检测饲料和注射液中利巴韦林含量,加标回收率为90%~110%,RSD为3.0%~7.9%.  相似文献   

6.
A PVC membrane sensor for the selective determination of mebendazole (MBZ) was fabricated. The sensor is based on an ion association of MBZ with silicotungstic acid (STA) as ion pair and bis(2-ethylhexyl)phthalate (BEP) as the plasticizing agent in a PVC matrix. The sensor showed a linear response for MBZ for a concentration range 1.0x10(-6)-5.0x10(-2) M with a Nernstian slope of 55.8 mV/decade (limit of detection 6.3x10(-7) M) in the pH range 4-7. It has a fast response time of <30 s. The sensor showed a very good selectivity for MBZ with respect to a large number of ions. The direct determination of MBZ in pharmaceutical formulations gave results that compare well with the data obtained from the standard method.  相似文献   

7.
A sulfate ion-selective PVC membrane sensor based on 4-(4-bromophenyl)-2,6-diphenylpyrilium perchlorate (BDPP) as a novel sensing material is successfully developed. The electrode shows a good selectivity for sulfate ion with respect to common organic and inorganic anions. The sensor exhibits a good linear response with slope of -28.9+/-0.5 mV per decade over the concentration range of 1.0x10(-6)-1.0x10(-2) M, and a detection limit of 8.0x10(-7) M of SO(4)(2-) ions. The electrode response is independent of pH in the range of 4.0-9.0. The proposed sensor was applied as an indicator electrode in potentiometric titration of sulfate and barium ions, and to the determination of zinc in zinc sulfate tablets.  相似文献   

8.
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.  相似文献   

9.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

10.
An electroanalytical method for the determination of the herbicide desmetryne at nanomolar levels in dispersed media, based on adsorptive stripping voltammetry, is reported. The adsorption of desmetryne at the hanging mercury drop electrode was checked both in micellar solutions, where the anionic surfactant sodium pentanesulphonate was chosen as the most suitable surfactant agent, and in oil-in-water emulsions prepared with ethyl acetate as the organic solvent. In a micellar medium formed with 0.02% sodium pentanesulphonate and with 0.1 mol l(-1) Britton-Robinson buffer (pH 1.5), the herbicide could be determined over the 1.0 x 10(-8)-4.0 x 10(-7) mol l(-1) concentration range, when an accumulation potential of -0.70 V was applied for 50 s. On the other hand, in an oil-in-water emulsion formed with 2% ethyl acetate and 0.04% sodium pentanesulphonate as emulsifying agent in 0.1 mol l(-1) HClO(4), desmetryne could be determined over the 2.0 x 10(-9)-1.0 x 10(-7) mol l(-1) concentration range. The limits of detection were 2.4 x 10(-9) and 4.2 x 10(-10) mol l(-1) in micellar and emulsified media, respectively, with R.S.D.s (n=10) 3.6 and 3.7%. The degree of interference from some other s-triazines on the desmetryne differential pulse response was also evaluated. Finally, the method developed in emulsified medium was applied to the determination of desmetryne in spiked apple juice.  相似文献   

11.
A PVC membrane electrode based on a cadmium-salen (N,N'-bis-salicylidene-1,2-ethylenediamine) complex as an anion carrier is described. The electrode has an anti-Hofmeister selectivity sequence with a preference for thiocyanate at pH 1.5-11.0. It has a linear response to thiocyanate from 1.0 x 10(-6) to 1.0 x 10(-1) mol L(-1) with a slope of 59.1 +/- 0.2 mV per decade, and a detection limit of 7 x 10(-7) mol L(-1). This electrode has high selectivity for thiocyanate relative to many common organic and inorganic anions. The proposed sensor has a fast response time of approximately 15 s. It was applied to the determination of thiocyanate in a milk sample.  相似文献   

12.
In our experiments, it was observed that adding bromide to Pb2+ solution of N,N'-dimethylformamide (DMF), the highly emissive cluster Pb4Br11(3-) can be formed and the fluorescence intensity of the formed cluster is proportional to the concentration of Pb2+, based on which, a novel, simple approach that uses the emission from itself as the sensor for determination of Pb2+ is proposed. Under the optimum conditions, the linear range and detection limit is 1.0 x 10(-7) to 1.0 x 10(-5) mol l(-1) (correlation coefficient r = 0.9997) and 7.6 x 10(-9) mol l(-1), respectively. Foreign substrates effects were also investigated. The proposed method has been successfully applied to the determination of lead in the synthetic samples. The mechanism of the reaction is also studied.  相似文献   

13.
A procedure for the determination of morphine in process streams by sequential injection analysis based on the chemiluminescence reaction of morphine with acidic potassium permanganate in the presence of sodium hexametaphosphate is presented. The chemiluminescence emission has been monitored using an in-house detection system which consisted of a fibre optic flowthrough cell and a sensitive, low dark current, photomultiplier tube. The calibration graph (range 2 x 10(-8) to 1 x 10(-4) mol/l) was not linear over the entire range of concentration, with a polynomial equation of best fit of y = 1.0 x 10(15) x(3) - 2.2 x 10(11) x(2) + 1.3 x 10(7) x - 8.3. The calibration function approximates linearity over the concentration range 2.5 x 10(-6) to 3.0 x 10(-5) mol/l where the slope of the log-log plot is 1.09 +/- 0.16. The detection limit was estimated at about 10(-8) mol/l from the response of the lowest calibration standard (2.5 x 10(-8) mol/l) which gave a signal to noise ratio of 3 : 1. Although the structurally related codeine did not interfere significantly the results suggest that this method may be susceptible to matrix effects, dependent on the location of sampling from the process stream.  相似文献   

14.
Mahajan RK  Kumar M  Sharma V  Kaur I 《The Analyst》2001,126(4):505-507
A PVC membrane electrode for silver(I) ion based on Schiff base-p-tert-butylcalix[4]arene is reported. The electrode works well over a wide range of concentration (1.0 x 10(-5)-1.0 x 10(-1) mol dm-3) with a Nernstian slope of 59.7 mV per decade. The electrode shows a fast response time of 20 s and operates in the pH range 1.0-5.6. The sensor can be used for more than 6 months without any divergence in the potential. The selectivity of the electrode was studied and it was found that the electrode exhibits good selectivity for silver ion over some alkali, alkaline earth and transition metal ions. The silver ion-selective electrode was used as an indicator electrode for the potentiometric titration of silver ion in solution using a standard solution of sodium chloride; a sharp potential change occurs at the end-point. The applicability of the sensor to silver(I) ion measurement in water samples spiked with silver nitrate is illustrated.  相似文献   

15.
An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slope of -59.8 +/- 0.5 mV decade(-1) for I- ion over a concentration range of 1.0 x 10(-5) - 1.0 x 10(-2) M with a limit of detection of 7.0 x 10(-6) M. The electrode displays a good selectivity for I- with respect to a number of inorganic and organic species. It canbe used over a pH range of 2.5 - 8.5. The membrane sensor was successfully applied to the determination of iodide in water samples and blood serum, as well as in pharmaceutical products such as iodoquinol and thyroxin.  相似文献   

16.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

17.
A simple flow injection system is proposed for the determination of thiamine in pharmaceutical formulations. The determination is based on the precipitation reaction of thiamine with silicotungstic acid in acidic medium to form a thiamine silicotungstate suspension that is measured at 420 nm. Adding 0.05% (w/v) poly(ethyleneglycol) in the carrier solution (0.5 mol l(-1) hydrochloric acid), an improvement in the sensitivity, repeatability and baseline stability of the flow injection system was obtained. The calibration graph was linear in the thiamine concentration range from 5.0x10(-5) to 3.0x10(-4) mol l(-1) with a detection limit of 1.0x10(-5) mol l(-1). The relative standard deviations for ten successive measurements of 1.0x10(-4) mol l(-1) and 2.5x10(-4) mol l(-1) thiamine were less than 1% and an analytical frequency of 90 h(-1) was obtained.  相似文献   

18.
Cadmium ion-selective electrode based on tetrathia-12-crown-4   总被引:1,自引:0,他引:1  
Shamsipur M  Mashhadizadeh MH 《Talanta》2001,53(5):1065-1071
A new polyvinylchloride membrane sensor for Cd(2+) ions based on tetrathia-12-crown-4 as an ionophore was prepared. The sensor exhibits a Nernstian response for cadmium ions over a wide concentration range (4.0 x 10(-7) to 1.0 x 10(-1) M) with a slope of 29+/-1 mV decade(-1). The limit of detection is 1.0 x 10(-7) M (0.01 ppm). It has a fast response time of <10 s and can be used for at least 6 weeks without any divergence in potential. The electrode can be used in the pH range from 2.5 to 8.5. The proposed sensor shows fairly good discriminating ability towards Cd(2+) ion in comparison with some alkali, alkaline earth, transition and heavy metal ions. It was successfully applied for the direct determination of Cd(2+) in solution and, as an indicator electrode, in potentiometric titration of cadmium ions.  相似文献   

19.
Abbaspour A  Izadyar A 《Talanta》2001,53(5):1009-1013
A PVC-based membrane of 4-dimethylaminoazobenzene reveals a Nernstian potentiometric response (with slope of 19.5+/-0.6 mV/decade and a correlation coefficient of 0.999) for Cr(III) over a wide concentration range (1.66 x 10(-6)-1.0 x10(-2) mol dm(-3)). The potential of this electrode is independent of pH in the range of 3.0-5.5. It has a fast response time of about 10 s and was used for a period of 3 months with good reproducibility. The detection limits of this membrane electrode was 8 x 10(-7) M. the proposed electrode has been used as an indicator electrode in the potentiometric titration of Cr(III) with EDTA. This sensor exhibits a very good selectivities for Cr(III) over a wide variety of metal ions.  相似文献   

20.
Zhang XB  Guo CC  Xu JB  Shen GL  Yu RQ 《The Analyst》2000,125(5):867-870
Lanthanide porphyrin complexes synthesized by a solid state method were used to prepare a novel ethacrynic acid (EA) sensor. The sensor, based on pentane-2,4-dionato(meso-tetraphenylporphinato)terbium [TbTPP(acac)] with an optimized membrane composition, exhibits a Nernstian response to EA- ion in the concentration range 7.4 x 10(-6)-1.0 x 10(-1) mol l-1 with a pH range from 3.2 to 6.8 and a fast response time of 30 s. The electrode shows improved selectivity towards EA- ion with respect to common co-existing ions compared with the previously reported EA sensor. As electroactive materials, lanthanide porphyrin complexes show better potentiometric response characteristics than copper porphyrin complexes. The effect of solvent mediators and lipophilic ion additives was studied and the experimental conditions were optimized. The electrode was applied to the determination of EA in human urine samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号