首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
适配体是一小段经体外筛选得到的寡核苷酸序列。适配体中的胸腺嘧啶(T)碱基可与Hg~(2+)形成比双链DNA更加稳定的T-Hg~(2+)-T结构。利用该性质结合电化学测量方法可制作检测Hg~(2+)的特异性强、灵敏度高的适配体电化学传感器,并建立微量Hg~(2+)的检测方法。该文对近年来发展的检测Hg~(2+)的适配体电化学传感器进行了综述和总结,对文献报道的几类传感器的构建过程和检测机理进行了详述,对检测方法的优缺点进行了分析。最后,对此类传感器今后的发展方向提出了展望,引用文献83篇。  相似文献   

2.
Electroanalysis has obtained considerable progress over the past few years, especially in the field of electrochemical sensors. Broadly speaking, electrochemical sensors include not only conventional electrochemical biosensors or non-biosensors, but also emerging electrochemiluminescence (ECL) sensors and photoelectrochemical (PEC) sensors which are both combined with optical methods. In addition, various electrochemical sensing devices have been developed for practical purposes, such as multiplexed simultaneous detection of disease-related biomarkers and non-invasive body fluid monitoring. For the further performance improvement of electrochemical sensors, material is crucial. Recent years, a kind of two-dimensional (2D) nanomaterial MXene containing transition metal carbides, nitrides and carbonitrides, with unique structural, mechanical, electronic, optical, and thermal properties, have attracted a lot of attention form analytical chemists, and widely applied in electrochemical sensors. Here, we reviewed electrochemical sensors based on MXene from Nov. 2014 (when the first work about electrochemical sensor based on MXene published) to Mar. 2021, dividing them into different types as electrochemical biosensors, electrochemical non-biosensors, electrochemiluminescence sensors, photoelectrochemical sensors and flexible sensors. We believe this review will be of help to those who want to design or develop electrochemical sensors based on MXene, hoping new inspirations could be sparked.  相似文献   

3.
Carbon nanotubes (CNTs) have been incorporated in electrochemical sensors to decrease overpotential and improve sensitivity. In this review, we focus on recent literature that describes how CNT-based electrochemical sensors are being developed to detect neurotransmitters, proteins, small molecules such as glucose, and DNA. Different types of electrochemical methods are used in these sensors including direct electrochemical detection with amperometry or voltammetry, indirect detection of an oxidation product using enzyme sensors, and detection of conductivity changes using CNT-field effect transistors (FETs). Future challenges for the field include miniaturizing sensors, developing methods to use only a specific nanotube allotrope, and simplifying manufacturing.  相似文献   

4.
General tendencies of the progress in the development of electrochemical DNA sensors devoted to the determination of biologically active low-molecular compounds have been considered on the base on own authors investigations and literary data. The ways for the generation of analytical signal of DNA sensors are considered depending on the mechanism of DNA- analyte interaction. The application of DNA sensors for the determination of pharmaceuticals (anthracyclines,. phenothiazines, sulfonylamides etc.) and environmental pollutants is described. The prospects of DNA sensor development are discussed.  相似文献   

5.
赵元弟  庞代文 《分析化学》1996,24(3):364-368
本文对电化学脱氧核糖核酸(DNA)传感器的原理,DNA在电极表面的固定化,杂交指示剂的研究和电化学DNA传感器的性能、分析应用及电化学石英晶体微天平DNA传感器等方面的研究进展作了评述。提出了今后研究工作的方向。  相似文献   

6.
In the field of DNA sensing, DNA hybridisation detection is generally performed by fluorescence microscopy. However, fluorescence instrumentation is difficult to miniaturise in order to produce fully integrated DNA chips. In this context, electrochemical detection of DNA hybridisation may avoid this limitation. Therefore, the use of DNA intercalators is particularly attractive due to their selectivity toward DNA double strand enabling DNA labelling without target chemical modification and, for most of them, to their electroactivity. We have synthesized a pyridoacridone derivative dedicated to DNA hybridisation electrochemical-sensing which presents good electrochemical reversibility, electroactivity at mild potentials and specificity toward DNA double strand. The electrochemical behaviour of this molecule has been assessed using cyclic voltammetry (CV). DNA/intercalator interactions were studied by differential pulse voltammetry (DPV) before application to hybridisation detection onto DNA sensors based on polypyrrole modified electrodes.  相似文献   

7.
DNA电化学传感器灵敏度高、选择性好、分析时间短和检测成本低,极大地推动了生物传感器的发展. 结合蛋白质酶、功能核酸酶的催化效率高与特异性好,可提高检测灵敏度和选择性. 本文评述了酶放大DNA电化学传感器的研究进展,并分析现存问题,展望发展趋势.  相似文献   

8.
《Electroanalysis》2006,18(2):163-168
Nanostructured films were deposited at the surface of working electrode of the screen‐printed assembly and utilized for the surface modification with double‐stranded DNA. The basic electrochemical properties of the sensors were investigated using voltammetric methods. Modified electrodes were also characterized by scanning electron microscopy and electrochemical impedance measurements. It was found that the electrode modification with DNA and nanomodifier leads to an enhanced sensitivity of the DNA voltammetric detection. New potentialities of the utilization of the K3[Fe(CN)6] cyclic voltammetric signal and electrochemical impedance spectroscopy were found. The DNA‐based biosensors showed good repeability and necessary stability within several days.  相似文献   

9.
Lu Y  Zhu N  Yu P  Mao L 《The Analyst》2008,133(9):1256-1260
This study describes a new kind of aptamer-based electrochemical sensor that is not based on the target binding-induced conformational change of the aptamers by using a 15-mer thrombin-binding aptamer (5'-GGTTGGTGTGGTTGG-3') as the model oligonucleotide. The sensors are developed by first self-assembling the aptamer (i.e. a thrombin-binding aptamer) onto an Au electrode and then hybridizing the assembled aptamer with a ferrocene (Fc)-labeled short aptamer-complementary DNA oligonucleotide to form an electroactive double-stranded DNA (ds-DNA) oligonucleotide onto the Au electrode. The binding of the target (i.e. thrombin) towards the aptamer essentially destroys the Watson-Crick helix structure of the ds-DNA oligonucleotide assembled onto the electrode and leads to the dissociation of the Fc-labeled short complementary DNA oligonucleotide from the electrode surface to the solution, resulting in a decrease in the current signal obtained at the electrode, which can be used for the determination of the target. With the thrombin-binding aptamer as the model oligonucleotide, the current decrease obtained with the aptamer-based electrochemical sensors is linear with the concentration of thrombin within the concentration range from 0 to 10 nM (DeltaI/nA = 6.7C(thrombin)/nM + 2.8, gamma = 0.975). Unlike most kinds of existing aptamer-based electrochemical sensor, the electrochemical aptasensors demonstrated here are not based on the conformational change of the aptamers induced by the specific target binding. Moreover, the aptasensors are essentially label-free and are very responsive toward the targets. This study may pave a facile and general way to the development of aptamer-based electrochemical sensors.  相似文献   

10.
Palecek E  Fojta M 《Talanta》2007,74(3):276-290
Magnetic beads (MBs) are versatile tools in the separation of nucleic acids, proteins and other biomacromolecules, their complexes and cells. In this article recent application of MBs in electrochemical biosensing and particularly in the development of DNA hybridization sensors is reviewed. In these sensors MBs serve not only for separation but also as a platform for optimized DNA hybridization. A hybridization event is detected separately at another surface, which is an electrode. The detection is based either on the intrinsic DNA electroactivity or on various kinds of DNA labeling, including chemical modification, enzyme tags, nanoparticles, electroactive beads, etc., greatly amplifying the signals measured. In addition to DNA hybridization, other kinds of biosensing in combination with MBs, such as DNA-protein interactions, are reviewed.  相似文献   

11.
Up to now, the development of the electrochemical DNA hybridization sensors relied on solid electrodes, on which both the hybridization and detection steps have been performed. Here we propose a new method in which the DNA hybridization is performed at commercially available magnetic beads and electrochemical detection on detection electrodes (DE). Due to minimum nonspecific DNA adsorption at the magnetic beads, very high specificity of the DNA hybridization is achieved. Optimum DE can be chosen only with respect to the given electrode process. It is shown that high sensitivity and specificity in the detection of relatively long target DNAs can be obtained (a) by using cathodic stripping voltammetry at mercury or solid mercury amalgam DEs for the determination of purine bases, released from DNA by acid treatment, and (b) by enzyme-linked immunoassay of target DNA modified by osmium tetroxide,2,2'-bipyridine (Os,bipy) at carbon DEs. Direct determination of Os,bipy at mercury and carbon electrodes is also possible.  相似文献   

12.
In electrochemical DNA hybridization sensors generally a single-stranded probe DNA was immobilized at the electrode followed by hybridization with the target DNA and electrochemical detection of the hybridization event at the same electrode. In this type of experiments nonspecific adsorption of DNA at the electrode caused serious difficulties especially in the case of the analysis of long target DNAs. We propose a new technology in which DNA is hybridized at a surface H and the hybridization is detected at the detection electrode (DE). This technology significantly extends the choice of hybridization surfaces and DEs. Here we use paramagnetic Dynabeads Oligo(dT)(25) (DBT) as a transportable reactive surface H and a hanging mercury drop electrode as DE. We describe a label-free detection of DNA and RNA (selectively captured at DBT) based on the determination of adenines (at ppb levels, by cathodic stripping voltammetry) released from the nucleic acids by acid treatment. The DNA and RNA nonspecific adsorption at DBT is negligible, making thus possible to detect the hybridization event with a great specificity and sensitivity. Specific detection of the hybridization of polyribonucleotides, mRNA, oligodeoxynucleotides, and a DNA PCR product (226 base pairs) is demonstrated. New possibilities in the development of the DNA hybridization sensors opened by the proposed technology, including utilization of catalytic signals in nucleic acid determination at mercury (e.g. signals of osmium complexes covalently bound to DNA) and solid DEs (e.g. using enzyme-labeled antibodies against chemically modified DNAs) are discussed.  相似文献   

13.
蒋宇婷  陈文 《分析测试学报》2017,36(10):1279-1286
多氯联苯(PCBs)为环境中持久性有毒有机污染物之一,对生态环境产生了严重的危害。随着科研人员对PCBs危害性认识的深入,PCBs监测方法的研究日益增多。该文概述了近年来国内外PCBs的主要分析方法,重点介绍了电化学传感器检测PCBs的研究成果,指出了目前电化学传感器检测PCBs存在的问题,并对电化学传感器在PCBs检测中的发展前景进行了展望。  相似文献   

14.
MXenes are recently developed two-dimensional layered materials composed of early transition metal carbides and/or nitrides that provide unique characteristics for biosensor applications. This review presents the recent progress made on the usage and applications of MXenes in the field of electrochemical biosensors, including microfluidic biosensors and wearable microfluidic biosensors, and highlights the challenges with possible solutions and future needs. The multilayered configuration and high conductivity make these materials as an immobilization matrix for the biomolecule immobilization with activity retention and to be explored in the fabrication of electrochemical sensors, respectively. First, how the MXene nanocomposite as an electrode modifier affects the sensing performance of the electrochemical biosensors based on enzymes, aptamer/DNA, and immunoassays is well described. Second, recent developments in MXene nanocomposites as wearable biosensing platforms for the biomolecule detection are highlighted. This review pointed out the future concerns and directions for the use of MXene nanocomposites to fabricate advanced electrochemical biosensors with high sensitivity and selectivity. Specifically, possibilities for developing microfluidic electrochemical sensors and wearable electrochemical microfluidic sensors with integrated biomolecule detection are emphasized.  相似文献   

15.
A novel switch-cytosensing strategy has been designed, which is based on the changes of electron transfer efficiency between ferrocene at the end of DNA and the electrode surface before and after cell transfection. This strategy provided a general and convenient method to fabricate efficient electrochemical cell sensors.  相似文献   

16.
E-DNA sensors, the electrochemical equivalent of molecular beacons, appear to be a promising means of detecting oligonucleotides. E-DNA sensors are comprised of a redox-modified (here, methylene blue or ferrocene) DNA stem-loop covalently attached to an interrogating electrode. Because E-DNA signaling arises due to binding-induced changes in the conformation of the stem-loop probe, it is likely sensitive to the nature of the molecular packing on the electrode surface. Here we detail the effects of probe density, target length, and other aspects of molecular crowding on the signaling properties, specificity, and response time of a model E-DNA sensor. We find that the highest signal suppression is obtained at the highest probe densities investigated, and that greater suppression is observed with longer and bulkier targets. In contrast, sensor equilibration time slows monotonically with increasing probe density, and the specificity of hybridization is not significantly affected. In addition to providing insight into the optimization of electrochemical DNA sensors, these results suggest that E-DNA signaling arises due to hybridization-linked changes in the rate, and thus efficiency, with which the redox moiety collides with the electrode and transfers electrons.  相似文献   

17.
Electrochemical DNA sensors represent a simple, accurate and economical platform for DNA detection. Gold nanoparticles are known to be efficient labels in electrochemical sensors and to be viable materials to modify the surface of electrodes thereby to enhance the detection limit of the sensor. For surface modification, gold nanoparticles are used in combination with nanomaterials like graphene, graphene oxide, or carbon nanotubes to improve electrochemical performance in general. This review (with 116 refs.) mainly covers the advances made in recent years in the use of gold nanoparticles in DNA sensing. It is divided into the following main sections: (a) An introduction covers aspects of electrochemical sensing of DNA and of appropriate nanomaterials in general. (b) The use of gold nanoparticles in DNA is specifically addressed next, with subsections on AuNPs acting as electrochemical labels, electron transfer mediators, signal amplifiers, carriers of electroactive molecules, catalysts, immobilization platforms, on silver enhancement strategies, on AuNPs modified with carbonaceous materials (such as graphenes and nanotubes), and on multiple amplification schemes. The review concludes with a discussion of current challenges and trends in terms of highly sensitive DNA based sensing using AuNPs.
Graphical abstract The review describes the state of the art in the use of gold nanoparticles in the electrochemical DNA sensors and contains sections on the use of AuNPs as labels, signal amplifiers, carriers of electroactive molecules, catalyst, immobilization platform, and on silver enhancement and multiple amplification strategies.
  相似文献   

18.
Single?Clayered graphene, emerging as a true two?Cdimensional nanomaterial, has tremendous potential for electrochemical catalysis and biosensing as a novel electrode material. Considering the excellent properties of graphene, such as large surface?Cto?Cvolume ratio, high conductivity and electron mobility at room temperature, low energy dynamics of electrons with atomic thickness, robust mechanical and flexibility, we give a general view of recent advances in electrochemical sensors based on graphene. We are highlighting here important applications of graphene and graphene nanocomposites, and the assay strategies in electrochemical sensors for DNA, proteins, neurotransmitters, phytohormones, pollutants, metal ions, gases, hydrogen peroxide, and in medical, enzymatic and immunosensors.
Graphical Abstract
Graphene, a recent star carbon nanomaterial with lots of excellent properties, has caused increasing interests on the development of new-types graphene-based electrochemical sensors including DNA and protein sensor, enzyme based sensor, immunosensor, neurotransmitter sensor, medicine sensor, phytohormone sensor, pollutants sensor, metals ion sensor, gas sensor, and H2O2 sensor  相似文献   

19.
We review the development of reagentless, electrochemical sensors for the sequence-specific detection of nucleic acids that are based on the target-induced folding or unfolding of electrode-bound oligonucleotides. These devices, which are sometimes termed E-DNA sensors, are comprised of an oligonucleotide probe modified on one terminus with a redox reporter and attached to an electrode at the other. Hybridization of this probe DNA to a target oligonucleotide influences the rate at which the redox reporter collides with the electrode, leading to a detectable change in redox current. Because all sensing elements of this method are strongly linked to the interrogating electrode, E-DNA sensors are label-free, operationally convenient and readily reusable. As E-DNA signaling is predicated on a binding-specific change in the dynamics of the probe DNA (rather than simply monitoring the adsorption of a target to the sensor surface) and because electroactive contaminants (interferents) are relatively rare, this class of sensors is notably resistant to false positives arising from the non-specific adsorption of interferents, and performs well even when challenged directly with blood serum, soil and other complex sample matrices. We review the history of and recent advances in this promising DNA and RNA detection approach.  相似文献   

20.
An electrochemical device is proposed for high-throughput electrochemical detection that consists of 32 row and 32 column electrodes on a single glass substrate. The row and column electrodes are connected to interdigitated array (IDA) electrodes to form 1024 (32 × 32) addressable sensor points in the device. Electrochemical responses from each of the 1024 sensors were successfully acquired on the device within 1 min using redox cycling at individual IDA electrodes, which ensures application of the device to comprehensive, high-throughput electrochemical detection for enzyme-linked immunosorbent assay (ELISA), reporter gene assay for monitoring gene expressions, and DNA analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号