首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
The core-shell luminol-doped SiO2 nanoparticles were synthesized and immobilized on the surface of chitosan film coating graphite electrode by the self-assembled technique. Then, a novel electrogenerated chemiluminescence (ECL) sensor for pyrogallol was developed based on its ECL enhancing effect for the core-shell luminol-doped silica nanoparticles. The ECL analytical performances and the sensing mechanism of this ECL sensor for pyrogallol were investigated in detail. The corresponding results showed that: compared with the conventional ECL reaction procedures by luminol ECL reaction system, the electrochemical (EC) reaction of pyrogallol and its subsequent chemiluminescence (CL) reaction occurred in the different spatial region whilst offering a high efficiency to couple the EC with the CL reaction to form the ECL procedures. In this case, this new sensing scheme offered more potential to improve the analytical performances of the ECL reaction. Under the optimum experimental conditions, this ECL sensor showed less than 5% decrease in continuums over 100 times ECL measurements, the detection limit was 1.0 × 1.0−9 mol/L for pyrogallol. The linear range extended from 3.0 × 10−9 mol/L to 2.0 × 10−5 mol/L for pyrogallol.  相似文献   

2.
Nie F  Lu J 《Talanta》2008,74(5):1242-1246
Calcein was found to be able to use as chemiluminescence reagent and post-chemiluminescence was observed when fenfluramine was injected into the mixture after the CL reaction of calcein–potassium permanganate. Based on this phenomenon, a flow injection CL method was established for the determination of fenfluramine. The possible CL mechanism was proposed. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10−7 to 6.0 × 10−6 g mL−1 and the detection limit was 6 × 10−8 g mL−1. The relative standard deviation was 2.2% for 5.0 × 10−7 g mL−1 fenfluramine (n = 11). This method was applied to the determination of fenfluramine in weight-reducing tonic successfully.  相似文献   

3.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


4.
Zhang BT  Zhao L  Lin JM 《Talanta》2008,74(5):1154-1159
Based on the chemiluminescence (CL) phenomena of folic acid in peroxomonosulfate-cobalt(II) system, a rapid and sensitive CL method was developed for determination of folic acid in pharmaceutical preparations and its urinary metabolism processes. Under the optimum conditions, the relative CL intensity was linear over the concentration ranging from 10−9 to 8 × 10−7 mol L−1 (R2 = 0.9991) with a detection limit as low as 6 × 10−10 mol L−1 (S/N = 3) and relative standard deviation was 2.63% for 2 × 10−8 mol L−1 folic acid (n = 11). This method has been successfully applied to the determination of folic acid in tablets and human urine. The blank CL emission was yielded owing to the formation of singlet oxygen molecular pair from the quenching experiment of 1,4-diazabicyclo[2.2.2]octane, and pterine-6-carboxylic acid might be the degradation intermediate in this system and it also acts an energy acceptor and sensitizes the chemiluminescence based on the studies of the CL and fluorescence spectra.  相似文献   

5.
A very sensitive electroanalytical method was employed to determine bergenin in phosphate buffer with a pH of 6.0, bergenin was accumulated at a 4-(2-pyridylazo)-resorcinol (PAR) polymer film modified glassy carbon electrode (GCE) surface under the condition of open-circuit. In the following anodic sweep from −0.4 to 0.8 V, bergenin adsorbed at the PAR polymer film modified electrode surface, was oxidized and yielded a sensitive oxidation peak at 0.595 V. Due to its unique structure and extraordinary properties, the PAR polymer film shows higher accumulation efficiency toward bergenin compared with a bare GCE. Hence, the amount of bergenin at the PAR polymer film modified GCE surface increases significantly, and finally the oxidation peak current improves greatly. The experimental conditions, such as supporting electrolyte, pH value, accumulation time and scan rate, were optimized for the measurement of bergenin, and a sensitive electroanalytical method was proposed for bergenin determination. The oxidation peak current varies linearly with the concentration of bergenin over the range of 2.0 × 10−7 to 1.2 × 10−5 mol/L, and the detection limit is 2.0 × 10−8 mol/L after 3 min open-circuit accumulation. The relative standard deviation of the same electrode in 10 successive scans is 1.8% for 1.0 × 10−6 mol/L bergenin and 2.1% for interelectrodes, indicating excellent reproducibility. This new method was successfully demonstrated with bergenin tablets and diluted urine.  相似文献   

6.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

7.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

8.
Fenoterol and salbutamol were determined by electrogenerated chemiluminescence (ECL) coupled with flow injection analysis (FIA), using Ru(bpy)32+ as the luminescent substance. Fenoterol and salbutamol oxidize together with the ruthenium 2,2-bipyridyl at a platinum electrode, which leads to an increase in the luminescent intensity, and this increase is proportional to the analyte concentration. For fenoterol a linear calibration curve within the range from 1.0 × 10−5 to 1.0 × 10−4 mol l−1 was obtained with a correlation coefficient of 0.998 (n = 5) and for salbutamol the linear analytical curve was also obtained in this range with a correlation coefficient of 0.995 (n = 5). The relative standard deviation was estimated as ≤2.5% for 3 × 10−5 mol l−1 for fenoterol solution and as ≤1.3% for 5.0 × 10−5 mol l−1 salbutamol solution for 15 successive injections. The limit of detection for fenoterol was 2.4 × 10−7 mol l−1 and for salbutamol was 4.0 × 10−7 mol l−1. Fenoterol and salbutamol were successfully determined in drug tablets and the soluble components of the matrix did not interfere in the luminescent emission. The results obtained using the luminescent methodology were not statistically different from those obtained by UV-spectrophotometry at 95% confidence level.  相似文献   

9.
Trivelin LA  Rohwedder JJ  Rath S 《Talanta》2006,68(5):1536-1543
An automated system for liquid–liquid extraction flow analysis (LLE-FA) for the determination of Sb(V) in antileishmanial drugs is presented. The method is based on extraction in a 5 mL glass extraction chamber of an ion pair formed between hexachloroantimoniate anion and rhodamine B cation into toluene. The detection system consists of a green light emitting diode (LED) and a photodiode. The system is controlled by a microcomputer using a program written in Visual Basic 3.0. The extraction process was optimized and the following experimental parameters were established: sample loop of 150 μL; reagent loop of 900 μL; stirring time of 100 s; phase separation time of 80 s; volumetric ratio of 1:1 (aqueous/organic). The method was in-house validated for the determination of Sb(V) in meglumine antimoniate. The following performance criteria were obtained: linearity of 0.9989, linear range of 7.0 × 10−5 to 7.2 × 10−4 mol Sb(V) L−1, sensitivity of 1.61 × 106 ± 2 arbitrary units L mol−1 (P < 0.05), intra-assay precision of 3.5% (n = 5; 4.1 × 10−4 mol L−1 Sb(V). Whereas the method is selective in the presence of Sb(III), As(III) and Pb(II) at concentrations up to one tenth of the concentration of Sb(V), As(V) interferes. The accuracy of the method was evaluated through comparison of results obtained from analyses of pharmaceutical formulations by the proposed LLE-FA method with those obtained by inductively coupled plasma optic emission spectrometry (ICP OES) and differential pulse polarography for total antimony and Sb(III), respectively. The proposed method presented an analytical frequency of eight analysis per hour and is suitable for Sb(V) determination in the quality control of drugs employed for the treatment of leishmaniasis.  相似文献   

10.
Li Zheng  Junfeng Song   《Talanta》2007,73(5):943-947
The voltammetric behavior of urapidil was investigated. In pH 6.8 Britton-Robinson buffer, an irreversible oxidation peak of urapidil at 0.62 V (versus SCE) at a multi-wall carbon nanotube paste electrode (MWNT-PE) was observed, which was more sensitive with lower potential than that at the carbon paste electrode (CPE). The oxidation of urapidil was a two-electron and two-proton process with adsorption character. A differential pulse voltammetric method was proposed for the determination of urapidil. The peak current of the oxidation peak of urapidil was linearly with its concentration in a range from 5.0 × 10−8 to 2.0 × 10−6 mol/L at open-circuit accumulation for 60 s, with a detection limit of 3.8 × 10−8 mol/L. The proposed method was employed to determine urapidil in urapidil tablets.  相似文献   

11.
In this work, we demonstrate for the first time that 4-methyl-5-nitrocatechol (4M5NC) and 2,4,5-trihydroxytoluene (2,4,5-THT), two compounds obtained from the 2,4-DNT biodegradation are recognized by polyphenol oxidase as substrates. An amperometric biosensor is described for detecting these compounds and for evaluating the efficiency of the 2,4-DNT conversion into 4M5NC in the presence of bacteria able to produce the 2,4-DNT-biotransformation. The biosensor format involves the immobilization of polyphenol oxidase into a composite matrix made of glassy carbon microspheres and mineral oil. The biosensor demonstrated to be highly sensitive for the quantification of 4M5NC and 2,4,5-THT. The analytical parameters for 4M5NC are the following: sensitivity of (7.5 ± 0.1) × 105 nAM−1, linear range between 1.0 × 10−5 and 8.4 × 10−5 M, and detection limit of 4.7 × 10−6 M. The sensitivity for the determination of 2,4,5-THT is (6.2 ± 0.6) × 106 nAM−1, with a linear range between 1.0 × 10−6 and 5.8 × 10−6 M, and a detection limit of 2.0 × 10−7. Under the experimental conditions, it was possible to selectively quantify 4M5NC even in the presence of a large excess of 2,4-DNT. The suitability of the biosensor for detecting the efficiency of 2,4-DNT biotransformation into 4M5NC is demonstrated and compared with HPLC-spectrophotometric detection, with very good correlation. This biosensor holds great promise for decentralized environmental testing of 2,4-DNT.  相似文献   

12.
Zenki M  Tanishita A  Yokoyama T 《Talanta》2004,64(5):1273-1277
Ascorbic acid (AA) could be determined in large quantities of a co-existing oxidant. The incorporation of an on-line reagent regeneration step based on redox reaction eliminates the baseline drift in the procedure. This makes it possible to adopt a circulatory flow injection method (cyclic FIA) and to determine AA repetitively. The method is based on the reduction of iron(III) to iron(II) by the analyte, the reaction of the produced iron(II) with 1,10-phenanthroline (phen) in a weak acidic medium to form a colored complex, and the subsequent oxidation reaction of iron(II) to iron(III) by the co-existing peroxodisulfate. A solution (50 ml) of 3.0×10−4 mol l−1 ferric chloride, 9.0×10−4 mol l−1 phen and 5.0×10−2 mol l−1 ammonium peroxodisulfate in acetate buffer (0.2 mol l−1, pH 4.5) is continuously circulated at a constant flow rate of 1.0 ml min−1. Into this stream, an aliquot (20 μl) of the sample solution containing AA is quickly injected by means of a six-way valve. The complex formed is monitored spectrophotometrically (at 510 nm) in the flow system. The stream then returns to the reservoir after passing through a time-delay coil (50 m). The iron(II)–(phen)3 complex is oxidized to iron(III)–(phen)3 complex by peroxodisulfate which exists excessively in the circulating reagent solution. The proposed method allows as many as 300 repetitive determinations of 15 mg l−1 AA with only 50 ml reservoir solution. The contents of AA in commercial pharmaceutical products were analyzed to demonstrate the capability of the developed system.  相似文献   

13.
Acetone and diazotized anthranilic acid react in alkaline solution, giving a fluorescent intermediate that can be measured at excitation and emission wavelengths of 305 and 395 nm, respectively. Based on this, a fluorimetric flow-injection method is proposed for the determination of acetone in aqueous solution. Under the proposed conditions, acetone can be detected at concentrations higher than 8 × 10−7 M, with a linear application range from 1 × 10−6 to 2 × 10−4 M and an R.S.D. of 2.7% (1.0 × 10−5 M, n = 10). A sampling frequency of 24 h−1 is achieved. Some potentially interfering species are investigated.  相似文献   

14.
Various amino acid derivatives of monascus pigments were synthesized. The effects of pigment derivatives on the pigment adsorption ratio, electrophoretic mobility (EPM) of bacterial cells, and antibacterial activity were investigated under varying conditions of pigment type, pigment concentration, pH, and ionic strength. Two hydrophobic and two hydrophilic derivatives were selected as model pigments. There was a close relationship between the antimicrobial activity and the pigment adsorption ratio. Against Escherichia coli, the hydrophobic l-Tyr and l-Phe derivatives (log P = 3.18 and 3.57) exhibited high antimicrobial activities (MIC = 8 and 16 mg/L) and high cellular adsorption ratios (9.6 and 10.9 mg/L). The hydrophilic l-Glu and l-Asn derivatives (log P = 1.40 and 0.47) exhibited low activities (MIC = 64 and 128 mg/L) and low adsorption ratios (4.7 and 4.0 mg/L). The electrophoretic mobility of 11 different bacteria varied between −1.93 × 10−8 and −1.19 × 10−8 m2 V−1 s−1 regardless of Gram+ or Gram. The l-Phe derivative showed low MIC values (high antimicrobial activities) against bacteria with a high electrophoretic mobility. A positive linearity between the pigment adsorption ratio and the electrophoretic mobility was established. When the four pigment derivatives were added to E. coli solutions, the electrophoretic mobility of cells in all cases sharply increased with an increasing pigment concentration. The mobility value was high for hydrophobic pigment derivatives in descending order of l-Phe (0.8 × 10−8 m2 V−1 s−1), l-Tyr (0.68 × 10−8 m2 V−1 s−1), l-Glu (0.46 × 10−8 m2 V−1 s−1), and l-Asn (0.44 × 10−8 m2 V−1 s−1). Additional adsorption of the hydrophobic derivatives probably occurred due to a hydrophobic interaction between the pigment and the pigment-coated cells. The electrophoretic mobility decreased gradually with an increasing pH and/or ionic strength with both addition and no addition of the pigment derivatives. The pattern of change of the pigment adsorption ratio under varying pH and/or ionic strength values was similar to the pattern for electrophoretic mobility.  相似文献   

15.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

16.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

17.
A new, highly sensitive and simple kinetic method for the determination of thyroxine was proposed. The method was based on the catalytic effect of thyroxine on the oxidation of As(III) by Mn(III) metaphosphate. The kinetics of the reaction was studied in the presence of orthophosphoric acid. The reaction rate was followed spectrophotometrically at 516 nm. It was established that orthophosphoric acid increased the reaction rate and that the extent of the non-catalytic reaction was extremely small. A kinetic equation was postulated and the apparent rate constant was calculated. The dependence of the reaction rate on temperature was investigated and the energy of activation and other kinetic parameters were determined.

Thyroxine was determined under the optimal experimental conditions in the range 7.0 × 10−9 to 3.0 × 10−8 mol L−1 with a relative standard deviation up to 6.7% and a detection limit of 2.7 × 10−9 mol L−1. In the presence of 0.08 mol L−1 chloride, the detection limit decreased to 6.6 × 10−10 mol L−1. The proposed method was applied for the determination of thyroxine in tablets. The accuracy of the method was evaluated by comparison with the HPLC method.  相似文献   


18.
In this work, nickel hexacyanoferrate-modified electrode was developed to determine potassium ions in biodiesel by potentiometry. The modified electrodes exhibit a linear response to potassium ions in the concentration range of 4.0 × 10−5 to 1.0 × 10−2 mol L−1, with a detection limit of 1.9 × 10−5 mol L−1, and a near-Nernstian slope (53–55 mV per decade) at 25 °C. The method developed in this work was compared with flame photometry and the potassium concentration found in biodiesel showed that the modified electrode method gives results similar to those obtained by flame photometry.  相似文献   

19.
A new approach for the synthesis and application of tailor-made derivatizing agents for liquid chromatography is presented. The s-triazine ring serves as the backbone for these substances. Synthesis is performed in three steps based on substitution reactions of cyanuric chloride. A chromophor or fluorophor, a reactive group and a third moiety intended to modify the polarity of the derivatizing agent are coupled to cyanuric chloride. The three groups may be selected freely from molecules which carry functional groups which might be linked to cyanuric chloride. As an example, the synthesis and application of a respective reagent for the determination of aldehydes and ketones using HPLC with fluorescence detection is carried out. Baseline separation of the derivatives and low limits of detection (1.5×10−9 mol/l for formaldehyde, 2.0×10−9 mol/l for acetaldehyde and 3.0×10−9 mol/l for p-tolualdehyde) are obtained with the new versatile reagent.  相似文献   

20.
A chemically modified electrode is constructed based on the multi-walled carbon nanotubes (MWNTs)/4-aminobenzeresulfonic acid (4-ABSA) film-coated glassy carbon electrode. The electrocatalytic oxidation of tyrosine (Tyr) is investigated on the surface of the MWNTs/4-ABSA-modified electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The prepared modified electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in optimal conditions, which makes it very suitable for sub-micromolar detection of Tyr. A sensitive oxidation peak at +0.64 V is employed to determine Tyr. Good linear relationship between the oxidation peak current and the Tyr concentration in the range of 1 × 10−7 to 5 × 10−5 mol/L is obtained in phosphate buffer solution with pH 7.0. By use of modified electrode, the voltammetric detection limit for Tyr in DPV measurements is 8 × 10−8 mol/L (S/N = 3). Good sensitivity, selectivity and stability of the low-cost modified electrode make it very suitable for the determination of trace amounts of Tyr in pharmaceutical and clinical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏