首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Human serum immunoglobulin M (IgM) or human immunoglobulin G (IgG) were adsorbed to dichlorodimethyl silane (DDS) treated silicon. Subsequently, the model surfaces were incubated in normal-, complement factor 1q (C1q)-complement factor B or complement factor 2 (C2)-depleted human sera at 37 degrees C for up to 1.5 h. The serum deposition and binding of selected polyclonal complement antibodies into this layer were then quantified by null ellipsometry. Both types of precoated surfaces bound large amounts of anti-complement factor 3c (anti-C3c), anti-properdin and anti-C3d, after incubation in normal serum. In contrast to IgG coated surfaces, IgM coated surfaces bound no anti-C1q after the serum incubations and no anti-C3c deposition lag time was observed after incubations in EGTA serum. Upon immersions of IgM coated surfaces in the different sera, a rapid complement activation via a C1q factor B, and Ca(2+)-independent, but C2 dependent pathway, was indicated. When IgM was instead immobilized to APTES/glutaraldehyde surfaces, anti-C3c deposition was lower after incubations in EGTA than normal serum. The results suggest that, under the present experimental conditions, human IgM and IgG activate the complement system differently.  相似文献   

2.
一种新的压电免疫传感器中生物分子固定化方法的研究   总被引:11,自引:0,他引:11  
生物分子固定化或传感界面设计技术是研制压电免疫传感器的关键之一。本文 结合自组装单分子膜(SAMs)和聚电解质静电吸附组装技术,提出了一种新的压电 免疫传感器中生物分子固定化方法,研制成一种检测补体C_3的压电免疫传感器。 先在石英晶振的金电极表面组装一层胱胺SAMs,再在膜上组装带相反电荷的聚苯磺 酸钠(PSS)单层膜,通过静电吸附作用固定抗体(抗原),实现对相应抗原(抗 体)的检测。利用扫描电镜技术,从形态上考察了晶振组装胱氨SAMs与PSS及固定 补体C_3抗体后的表面形貌。研究了抗体的固定化条件,探讨了传感器采用这种固 定化方法的响应与再生性能,并与戊二醛键合固定法进行比较。结果表明,这种固 定化方法不仅对蛋白质类生物分子的固定化具有普适性,而且对所固定的生物分子 的活性影响小,传感器的响应的频移值大,灵敏度高,选择性和再生性能均较好。  相似文献   

3.
The anticoagulant properties of heparin stem in part from high‐affinity binding to antithrombin‐III (AT‐III) inducing a 300‐fold increase in its inhibitory activity against the coagulation protease factor Xa. The minimal structural requirements for AT‐III binding are contained in the rare heparin pentasaccharide sequence containing a 3,6‐O‐sulfated N‐sulfoglucosamine residue. ACE is used in this work to measure the relative AT‐III binding affinities of the low molecular weight heparins (LWMHs) dalteparin, enoxaparin, and tinzaparin and the synthetic pentasaccharide drug fondaparinux (Arixtra). Determination of the AT‐III binding affinities of the LWMHs is complicated by their inherent structural heterogeneity and polydispersity. The fractional composition of 3‐O‐sulfo‐N‐sulfoglucosamine residues was determined for each drug substance using 2D NMR and used in the interpretation of the ACE results.  相似文献   

4.
In recent papers, we presented a new analytical method for thiol quantification in serum. It is based on the use of capillary electrophoresis and laser-induced fluorescence to analyze thiol 6-iodoacetamidofluoresceine (IAF) derivatives. Quantitative results of homocysteine, glutathione, cysteine-glycin, and cysteine were shown (Clin. Chem. 45 (1999) 412). A comprehensive comparison of the quantitation of homocysteine in serum, using high-performance liquid chromatography/conventional fluorescence detection and fluorescence polarization immunoassay was also used (E. Caussé et al., Electrophoresis 21 (2000) 2074). Sample preparation prior to derivatization with IAF had never been investigated. In this work we present the results of quantitation of thiols in serum and plasma with three different anticoagulants widely used: ethylenediaminetetraacetic acid (EDTA), heparin, and sodium citrate. We show that serum and EDTA plasma gave the same results. Then serum protein precipitations by acetonitrile, acetone, sulfosalicylic acid, perchloric acid and trichloracetic acid, prior to derivatization by IAF, were also investigated. Their influence on the concentrations of the thiols were determined. Sulfosalicylic acid and acetonitrile precipitations are well adapted, whereas acetone cannot be used.  相似文献   

5.
Clotting and anticoagulation of blood samples may give rise to different metabolic profiles of serum and plasma samples, respectively. The anticoagulant used for blood plasma preparation may affect the resulting metabolic profile due to different mechanisms involved in anticoagulation by various agents, e.g. heparin, EDTA and citrate. In the present study, we looked into metabolite and other differences in matched serum and plasma samples and different plasma preparations by using untargeted UPLC-ESI-QTOF/MS profiling and multivariate data analysis (PCA and OPLS-DA). Metabolite differences between serum and plasma samples were mainly related to small peptides reflecting presence or absence of coagulation. Only subtle metabolite differences between the different plasma preparations were noticed, which were primarily related to ion suppression or enhancement caused by citrate and EDTA anticoagulants. For the first time, we also report that anticoagulant counter cation (Na+ or K+) in Na-citrate and K-EDTA plasma can make some metabolites more dominant in ESI-MS. Polymeric material residues originating from blood collection tubes for serum preparation were observed only in serum samples. Hypoxanthine and xanthine were found at higher levels in serum than in plasma samples, possibly due to release from the clot. Mass spectral features of sodium formate and potassium formate ion clusters were detected in citrate and EDTA plasma samples, respectively, originating from formate in mobile phase and Na+ (in Na-citrate tubes) and K+ (in K-EDTA tubes). Among the anticoagulants, heparin is recommended for plasma samples used for LC-ESI/MS-based metabolomics of hydrophilic compounds because no plasma interferences or matrix effects were noticed for this polarity range. Citrate and EDTA should be avoided since interferences and serious matrix effects were encountered on some co-eluting polar metabolites. Serum is recommended as a second choice and an alternative to plasma. In conclusion, heparin plasma or serum should be the order of best choice for LC-ESI/MS-based metabolomics research.  相似文献   

6.
We have developed a methodological system consisting of a new surface sensitive quartz crystal microbalance with dissipation monitoring (QCM-D) sensor surfaces together with different surface modification methods for the investigation of surface associated complement activation in human sera. The QCM-D surface, 10 mm in diameter, was modified by spin-coating of poly(urethane urea) (PUUR) and polystyrene (PS). Some sensor surfaces were also sputtered with titanium (Ti) or modified by hydrophobic self-assembled monolayer (SAM) of an 18-carbon alkane thiol with a ---CH3 end group. The amount of surface deposited complement protein was investigated by incubation of the modified sensor surfaces in human sera, followed by incubation with antibodies directed against complement factor 3c (C3c). The amounts of bound anti-C3c were then used as an arbitrary measure of surface induced complement activation. The order of complement activation of the different surfaces, as judged by three separate measurements per surface modification, was PUUR>PS=SAM>Ti. The Ti surface had a similar low degree of anti-C3c binding as the negative controls (heat inactivated sera). The novel QCM-D methodology was found to be very simple, accurate, sensitive and well suited as a screening method for complement activation and protein adsorption on different materials. We also compared the sensitivity of QCM-D method with surface plasmon resonance (SPR) for the quantification of protein adsorption and complement activation on gold sensor surfaces. The QCM-D method was equally sensitive as the SPR for the detection of protein adsorption from a solution independently if low flow rate (5 μl/min) was used. A slight increase in sensitivity was found at higher flow rate (30 μl/min). However, we found it difficult to use the SPR method on the Ti, PS and PUUR surfaces due to decreased light penetration of the modified SPR sensor chip.  相似文献   

7.
Amino acid analysis in plasma samples is a very important and difficult task and could represent a useful tool for preventing the occurrence of some diseases (diabetes, cancer, HIV disease). Even though amino acid analysis has been thoroughly investigated, there are still some steps which are not so clear in this analytical procedure, e.g. the coagulation process of the blood to afford plasma and serum. Various anticoagulants are used in clinical chemistry: in this paper we have investigated three commonly used anticoagulants, heparin, EDTA, and sodium citrate. The blood samples have been divided into three portions and each portion treated with a different anticoagulant. The entire analytical procedure (from blood collection to the coagulation all the way to HPLC analysis) has been extensively investigated; the chromatograms and the amino acid recoveries are reported, and the three anticoagulants compared. Finally, the best anticoagulant has been used to analyze glycemic curves of healthy patients: the behavior of essential amino acids in the different blood samples withdrawn has been studied.  相似文献   

8.
Crosslinked multilayer protein films were prepared from fibrinogen, albumin, IgG, a combination of fibrinogen and catalase, and blood plasma on silicon by ethyl-dimethyl-aminopropylcarbodiimide and N-hydroxy-succinimide coupling chemistry. The 4–70 nm thick films were placed in blood plasma and the additional protein deposition measured by null ellipsometry after 5 or 60 min of incubation. The activation of the complement system and intrinsic pathway of coagulation were indicated through the subsequent binding of anti-C3c, anti-C3d, anti-properdin and anti-HMWK on top of the surface bound blood plasma. The proportion of Annexin V, Propidium Iodide and 4,6-diamidino-2-phenylindole positive cells, and the secretion of tumor necrosis factor (TNF-) and interleukin-10 (IL-10) were analysed in a monocyte culture. The results show that well known protein coupling techniques can be used for the preparation of protein layers with well controlled thickness. The layers possess low contact activation of blood plasma and induce different release of TNF- and IL-10 in monocyte cultures.  相似文献   

9.
刘栗加  胡继明  裴仁军  沈竞凯 《分析化学》1999,27(10):1190-1192
研制了一种可重复使用的压电免疫传感器用于检测补体C1q.比较了聚乙烯亚胺粘附、戊二醛交联法,物理吸附法以及蛋白A法三种固定化抗体蛋白的方法.使用蛋白A法,补体C1q在所测浓度范围内有良好的线性关系.使用过的晶片用0.1 mol/L柠檬酸盐缓冲溶液(pH 3.0)解吸,可重复使用4次.  相似文献   

10.
为了赋予聚丙烯微孔膜(PPMM)选择性吸附低密度脂蛋白(LDL)的能力,发展了一种有效的PPMM表面共价固定肝素的方法.基于紫外引发丙烯酸的接枝聚合,通过碳二亚胺活化,以乙二胺为间隔臂,将肝素共价固定于PPMM表面,获得表面肝素化的PPMM.ATR-FTIR和XPS分析确证了修饰过程中膜表面基团及化学成分的变化.采用静...  相似文献   

11.
H Kohno  Y Ohkubo  A Kubodera 《Radioisotopes》1987,36(10):523-525
The effect of sodium citrate on the blood disappearance of 67Ga was examined in rats. The half life value of the alpha phase and the initial AUC value (0-60 min) were dose-dependently decreased by sodium citrate. The binding of 67Ga to serum proteins was also dose-dependently inhibited by sodium citrate.  相似文献   

12.
在水溶液中分别以十六烷基三甲基溴化铵(CTAB)和CTAB/柠檬酸钠混合剂为包覆剂合成钯纳米颗粒,并研究其形貌演变.钯纳米颗粒在成核阶段会形成具有不同孪晶结构的晶核,在生长阶段又会选择性的放大某一组晶面,这两个因素导致了钯纳米颗粒形貌的多样性.在合成中CTAB既会影响钯纳米颗粒的成核,也会影响颗粒晶面的选择性生长.通过改变CTAB和还原剂的量可以调控钯纳米颗粒的形貌.溶液中CTAB和还原剂浓度的改变,非常明显地影响合成产物中不同形貌钯纳米颗粒的产率.通过向溶液中引入柠檬酸离子调控纳米颗粒的成核与生长过程,首次合成出了星状钯二十面体和截面为五角星形的钯纳米棒.这些不同形貌的钯纳米颗粒有着不同的表面等离子体共振和表面增强拉曼散射性质.  相似文献   

13.
以2,3-O-(2-氰基苄基)-4-O-氯乙酰基-β-对甲基苯基-D-葡萄糖醛酸硫苷等7个单糖模块作为糖基供体, 以甲醇等醇类化合物作为糖基受体, 分别在二氯甲烷和甲苯溶剂中进行了糖基化反应, 研究了葡萄糖醛酸C2位引入2-氰基苄基(BCN)以及溶剂效应对糖苷键α/β选择性的影响. 通过对糖基产物的 1H NMR, 13C NMR和HSQC等谱图分析发现, BCN可以有效提高糖苷键的β选择性, 其中部分糖基化产物的糖苷键α/β比例最高可达1/50. 为磺达肝癸钠分子中葡萄糖醛酸的β糖苷键的构建方法做出了初步探索.  相似文献   

14.
结合纳米金及混合自组装技术, 制备了一种新型网状混合膜, 提出了一种新的生物分子固定化方法, 研制了一种用于检测人血清抗精子抗体的压电免疫传感器. 首先, 将纳米金溶胶、巯基丙酸和1,6-二巯基己烷按一定的比例混合制得网状混合自组装膜, 然后将此膜组装到压电石英晶振的金电极表面, 经EDC/NHS活化后, 再将抗原固定到电极上, 实现对抗精子抗体的检测. 结果表明, 该方法能明显提高抗体抗原结合效率, 从而提高传感器的灵敏度, 并降低传感界面的非特异性吸附. 将此传感器应用于人血清抗精子抗体的检测, 线性范围为10~800 mU/mL, 检出限为7 mU/mL. 此传感器为抗精子抗体的临床检测提供了新平台.  相似文献   

15.
Probing BSA binding to citrate-coated gold nanoparticles and surfaces   总被引:5,自引:0,他引:5  
The interaction of bovine serum albumin (BSA) with gold colloids and surfaces was studied using zeta-potential and quartz crystal microbalance (QCM) measurements, respectively, to determine the surface charge and coverage. The combination of these two measurements suggests that BSA binding to gold nanoparticles and gold surfaces occurs by an electrostatic mechanism when citrate is present. The binding of BSA to bare gold is nearly two times greater than the binding of BSA to a citrate-coated gold surface, suggesting that protein spreading (denaturation) on the surface may occur followed by secondary protein binding. On the other hand, binding to citrate-coated gold surfaces can be fit to a Langmuir isotherm model to obtain a maximum surface coverage of (3.7 +/- 0.2) x 10(12) molecules/cm(2) and a binding constant of 1.0 +/- 0.3 microM(-1). The zeta-potential measurements show that the stabilization of colloids by BSA has a significant contribution from a steric mechanism because the colloids are stable, even at their isoelectric point (pI approximately 4.6). To be consistent with the observed phenomena, the electrostatic interactions between BSA and citrate must consist of salt-bridges, for example, of the carboxylate-ammonium type, between the citrate and the lysine on the protein surface. The data support the role of strong electrostatic binding but do not exclude contributions from steric or hydrophobic interactions with the surface adlayer.  相似文献   

16.
pH敏感相分离高分子的免疫分析应用研究   总被引:1,自引:0,他引:1  
合成了溶解性受pH值影响的高分子化合物聚甲基丙烯酸甲酯-丙烯酸-顺丁烯二酸酐(MAM)及聚甲基丙烯酸一丙烯酰胺-N-羟基琥珀酰亚胺丙烯酸酯(MAN),分别与抗体进行了共价连接,将其用作免疫分析载体,利用其溶解性可调节特征,建立了新的免疫分析方法.以聚甲基丙烯酸-丙烯酰胺-N-羟基琥珀酰亚胺丙烯酸酯为载体,对血清中乙肝表面抗原进行了检测,阴阳性检出结果与常规ELISA方法相符.  相似文献   

17.
Rapid liquid chromatographic procedures are proposed for analysis of paracetamol and orphenadrine citrate in pharmaceutical preparations and human serum using acetonitrile: water (50:50) as a mobile phase, adjusting pH to 2.6, UV detection at 215 nm and propylparaben sodium as internal standard. The advantages of this method include good and rapid separation, well resolved peaks, and only a small amount of sample is required for assay and adequate precision. The method showed good linearity in the range of 6 to 10000 ng/mL for paracetamol serum concentrations with a correlation coefficient 0.9999 (inter and intra day CV < 3.15) and in the range 3–10000 ng/mL for orphenadrine citrate serum concentrations with a correlation coefficient of 0.9999 (inter and intra day CV < 3.58). The recovery of paracetamol and orphenadrine citrate was > 96.9% and > 96.7%, respectively. The proposed method may be used for the quantitative analysis of paracetamol and orphenadrine citrate alone or in combination from raw materials, in bulk drugs, dosage formulations and in serum.  相似文献   

18.
化学发光酶联免疫分析测定血清中抗DNA抗体   总被引:1,自引:1,他引:1  
建立起适于临床应用的抗DNA抗体化学发光酶联免疫分析法。该法精密度良好,相对标准偏差为2.4%。比ELISA法更加简便、经济、省时,同时提高了灵敏度(8倍)和血清的阳性检出率。探讨了检测系统中对碘苯酚增强鲁米诺-过氧化氢-辣根过氧化物酶化学发光反应机理。  相似文献   

19.
Liu G  Khor SM  Iyengar SG  Gooding JJ 《The Analyst》2012,137(4):829-832
An electrochemical immuno-biosensor for detecting glycosylated haemoglobin (HbA1c) is reported based on glassy carbon (GC) electrodes with a mixed layer of an oligo(phenylethynylene) molecular wire (MW) and an oligo(ethylene glycol) (OEG). The mixed layer is formed from in situ-generated aryl diazonium cations. To the distal end of the MW, a redox probe 1,1'-di(aminomethyl)ferrocene (FDMA) was attached followed by the covalent attachment of an epitope N-glycosylated pentapeptide (GPP), an analogon to HbA1c, to which an anti-HbA1c monocolonal antibody IgG can selectively bind. HbA1c was detected by a competitive inhibition assay based on the competition for binding to anti-HbA1c IgG antibodies between the analyte in solution, HbA1c, and the surface bound epitope GPP. Exposure of the GPP modified sensing interface to the mixture of anti-HbA1c IgG antibody and HbA1c results in the attenuation of ferrocene electrochemistry due to free antibody binding to the interface. Higher concentrations of analyte led to higher Faradaic currents as less anti-HbA1c IgG is available to bind to the electrode surface. It was observed that there is a good linear relationship between the relative Faradaic current of FDMA and the concentration of HbA1c from 4.5% to 15.1% of total haemoglobin in serum without the need for washing or rinsing steps.  相似文献   

20.
Critical micelle concentrations of AOT in water in the presence of sodium chloride, sodium acetate, sodium propionate, and sodium butyrate were determined at 25 degrees C by the surface tension method. The co-ions do not have any effect on the value of critical micelle concentration. The surface density of AOT at the air-water interface increases in the presence of added electrolyte and attains a maximum value of 2.5+/-0.1 mol m-2 at a particular electrolyte concentration which is different for sodium chloride and the other three electrolytes. From the Corrin-Harkins plot it has been found that for AOT micelles the counterion binding constant has values 0.40 and 0.82 below and above approximately 0.015 mol kg-1 electrolyte concentration (c*), respectively. Measurement of sodium ion activity from the EMF method has confirmed such a shift in the counterion binding constant of AOT at c*. The higher value of the counterion binding constant for AOT has been reported for the first time. From fluorescence spectroscopy it has been found that the aggregation number of AOT is 22 in water and its average aggregation numbers in the presence of electrolytes are about 34 and 136 below and above c*, respectively. The increase by a factor of 2 in the counterion binding constant is shown to be due to a change in the shape of the AOT micelles around c*. The shape of AOT micelles in the electrolyte concentration range c* is inferred to be oblate spheroid and a change from this shape appears to occur above c*. A sudden increase in the polarity of the micelle-solution interface is also observed above c*.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号