首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The determination of volatile organic compounds (VOC) species and concentrations are important for the evaluation of indoor air quality. Numerous methods exist for the determination of levels of both VOC and TVOC (total volatile organic compounds). These include the use of direct-reading instruments as well as gas chromatographic techniques. The benefits and drawbacks of the various methods are well known, and none provide precise measurement of the complex VOC mixtures that constitute TVOC in indoor air. A specific approach for TVOC measurement has been proposed in Europe in ECA-report no.19 to overcome these shortcomings. On this basis a practical analytical method was developed and applied to emission test chamber studies. Special focus was required on compounds of high volatility and the preparation of calibration standards.  相似文献   

2.
Applications of solid-phase microextraction (SPME) to the sampling and analysis of volatile organic compounds in indoor air are reviewed, including a summary of quantification methods, coatings, compounds, concentrations, sampling locations and times, and detection limits. Strategies for on-site and off-site sampling and analysis, advantages and challenges associated with SPME for air sampling are discussed.  相似文献   

3.
Three kinds of diffusion samplers, conceived to perform long-term samplings in indoor sites are illustrated in this work. Two of them, in part deriving from the previous "Analyst for VOC" device, extend the field of application up to the semi-volatile organic compounds (SVOC), PAHs and nicotine in particular. A third device, which employs a basic barium hydroxide solution as an absorbing medium, is proposed for the determination of carbon dioxide levels which indicate the air change quality in the indoor sites. Laboratory and field experiments, performed in order to assess the reliability of the proposed devices, are shown. A monthly monitoring campaign, performed at three private apartments in Rome and its outskirts highlights that the indoor pollution levels are a complex function of various concurrent and opposite factors, like external air pollution, internal sources, air change rate and sink effect of surfaces, which contribute to depletion phenomena through adsorption and/or decomposition processes.  相似文献   

4.
This article reviews recent literature on the analysis of industrial contaminants in indoor air in the framework of the REACH project, which is mainly intended to improve protection of human health and the environment from the risks of more than 34 millions of chemical substances. Industrial pollutants that can be found in indoor air may be of very different types and origin, belonging to the volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) categories. Several compounds have been classified into the priority organic pollutants (POPs) class such as polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and furans (PCDD/PCDFs) and related polychlorinated compounds, and polycyclic aromatic hydrocarbons (PAHs). Many of these compounds are partially associated to the air gas phase, but also to the suspended particulate matter. Furthermore, settled dust can act as a concentrator for the less volatile pollutants and has become a matrix of great concern for indoors contamination. Main literature considered in this review are papers from the last 10 years reporting analytical developments and applications regarding VOCs, aldehydes and other carbonyls, PCBs, PCDDs, PCDFs, and PAHs in the indoor environment. Sample collection and pretreatment, analyte extraction, clean-up procedures, determination techniques, performance results, as well as compound concentrations in indoor samples, are summarized and discussed. Emergent contaminants and pesticides related to the industrial development that can be found in indoor air are reviewed in a second part in this volume.  相似文献   

5.
Field air analysis with SPME device   总被引:5,自引:0,他引:5  
Solid-phase microextraction (SPME) devices were used for a wide scope of air-monitoring including field sampling and analysis of volatile organic compounds (VOCs), formaldehyde, and particulate matter (PM) in air. Grab (instantaneous) and time-weighted average (TWA) sampling were accomplished using exposed and retracted SPME fibers, respectively. Sampling time varied from 1 to 75 min, followed by analysis with a gas chromatograph (GC). A portable GC equipped with unique, in-series detectors: photoionization (PID), flame ionization (FID), and dry electrolytic conductivity (DELCD), provided almost real-time analysis and speciation for common VOCs during an indoor air quality surveys. Indoor air samples collected with SPME devices were compared with those collected using conventional National Institute for Occupational Safety and Health (NIOSH) methods. Air concentrations measured with the SPME device were as low as 700 parts-per-trillion (ppt) for semi-volatile organic compounds. SPME methodology proved to be more sensitive than conventional methods, and provided a simple approach for fast, cost-effective sampling and analysis of common VOCs in indoor air. SPME technology combined with fast portable GC reduced the sampling and analysis time to less than 15 min. The configuration offered the conveniences of immediate on-site monitoring and decision making, that are not possible with conventional methods. In addition, SPME fibers were applied to sampling of particulate matter in diesel engine exhaust. Linear uptake and particulate build-up on the fiber were observed. Preliminary research suggests that SPME fibers could also be applied to sampling of airborne particulate matter.  相似文献   

6.
Exposure to fragrance substances is exponentially increasing in our daily life due to the enhanced use of scented products. Some fragrances are known to be important sensitizers, inhalation being an important exposure pathway in indoor environments. A simple and sensitive method based on solid-phase enrichment and solid-phase microextraction (SPME) followed by gas chromatography–mass spectrometry (GC–MS) has been developed for the analysis of 24 volatile fragrance allergens in indoor air. Suspected allergens present in the air (0.2 m3) were adsorbed onto a very small quantity of florisil (25 mg) and then transferred to a SPME fiber in the headspace mode (HS). To the best of our knowledge, this paper describes the first application of SPME for the determination of these compounds in air samples. The experimental parameters affecting the microextraction process have been optimized using a multifactor experimental design strategy. Accuracy, linearity, precision and detection limits (LODs) were evaluated to assess the performance of the proposed method. External calibration, using spiked sorbent standards, and not requiring the complete sampling process (only the SPME step), demonstrated to be suitable for the quantification of all suspected allergens. Recovery studies were performed at three concentration levels (0.04, 1.00 and 50 μg m−3), obtaining quantitative recoveries (≥85%) in most cases. LOD values at the low ng m−3 level were achieved for all the target compounds. The application of the method to daily home air samples demonstrated the ubiquity of this kind of fragrance ingredients in quotidian indoor environments, finding 18 of the 24 considered compounds in concentrations ranging from 0.01 to 56 μg m−3. Benzyl alcohol, linalool, citronellol, ionone and lilial were found in most analyzed samples.  相似文献   

7.
An analytical method was established for the simultaneous determination of 39 polycyclic aromatic hydrocarbons (PAHs) in air. The method was applied to a survey of gaseous and particulate PAHs in household indoor air. The survey was performed in 21 houses in the summer of 1999 and in 20 houses in the winter of 1999-2000 in Fuji, Japan. Thirty-eight PAHs were determined in indoor and outdoor air in the summer, and 39 PAHs were determined in indoor and outdoor air in the winter. The concentrations of gaseous PAHs in indoor air tended to be higher than those in outdoor air in the summer and winter. The concentrations of particulate PAHs in indoor air were the same as or lower than those in outdoor air in the summer and winter. PAH profiles, correlations between PAH concentrations, and multiple regression analysis were used to determine the factors affecting the indoor PAH concentrations. These results showed that gaseous PAHs in indoor air were primarily from indoor emission sources, especially during the summer, and that indoor particulate PAH concentrations were significantly influenced by outdoor air pollution.  相似文献   

8.
An analytical method was established for the determination of benzene and 13 of its alkyl derivatives. The method was applied to a survey of indoor pollution that investigated the usefulness of the method, concentration levels, seasonal variations, profiles, correlations between compounds, and factors that affected indoor pollution by these compounds. The survey was performed in 21 houses in the summer of 1999 and 20 houses in the winter of 1999-2000 in Fuji, Japan. All the target compounds were detected in the indoor and outdoor air of all houses. Outdoor concentrations of benzene ranged from 0.779 to 3.17 microg/m3 in summer and from 1.35 to 6.04 microg/m3 in winter, whereas indoor concentrations of benzene ranged from 0.694 to 3.11 microg/m3 in summer and from 1.65 to 6.89 microg/m3 in winter. Indoor concentrations of the target compounds, except for benzene, were elevated, compared with outdoor concentrations. Because indoor and outdoor concentrations of benzene and its derivatives in summer were lower than in winter, the emission of these compounds may be increased by use of a heater and other variables present in winter. Profiles of the compounds, correlations between the compounds, and factors that affected indoor pollution (determined by multiple regression analysis) were investigated. These results suggested that indoor benzene predominantly penetrated from outdoors and that other benzene derivatives were emitted from indoor sources, such as paint solvents and kerosene heaters.  相似文献   

9.
An instrument has been developed and tested for the continuous measurement of volatile organic compounds (VOC) in air. The system consists of a gas chromatograph equipped with a dedicated sampling device that allows the sample to be transferred to a cooled microtrap via sampling loops (10, 100, 250 ml) or via a direct pump transfer to the trap. The microtrap is placed in the chromatographic oven just below a modified split-splitless injector, allowing direct liquid injection for calibration of the system; the injector is in communication with the sampling valve equipped with the loop and the sampling pump. The system allows 24-hour sampling and analysis of a large number of VOC (up to 25 individual hydrocarbons ranging from C2 C9) and also polar volatile organic compounds PVOC. Thanks to the particular trap geometry, a minimum consumption of liquid nitrogen (between 150 300 ml) is needed for each analytical run and no water managing system is normally required for humid air samples.  相似文献   

10.
Levels of urban gaseous and particulate pollutants were investigated in the Cathedral of Cologne, Germany in the framework of the EU-project “VIDRIO”. The purpose of this study was to evaluate the influence of a protective double glazing system on the preservation of ancient stained glass windows by sampling at protected and unprotected windows (indoors, in the interspace and outdoor of the Cathedral). The interspace between the ancient stained glass window and the protective glazing is flushed in the Cathedral by indoor air, hence isolating the historic glass from the outdoor air and exposing it to indoor air on both sides of the glass panels. Concentrations of aggressive gaseous pollutants such as NO2, SO2, O3 and CO2 as well as elemental concentrations of bulk particles and relative abundances of single particles were surveyed at all sampling locations. Elemental concentrations in bulk particulate matter were found to be significantly lower inside the Cathedral in comparison to the outdoor air. This result is advantageous for the stained glass windows. Single particle analysis of the samples from Cologne showed also soil dust and organic particles as well as sulphates and nitrates, from which the latter two compounds are dangerous for the stained glass windows. On the base of the obtained results, it can be concluded that the protective glazing system in the Cathedral of Cologne can be considered as predominantly advantageous from both the gases' point of view (except for NO2-candles burning) and from the particles' point of view.  相似文献   

11.
Speciated volatile organic compounds (VOC), either as ozone precursors or air toxics in the air, are commonly monitored by triggered canister method or continuous ozone precursor analyzer (commonly known as Auto-gas chromatography (GC)) method. In the triggered canister method, a canister sample is collected when a total non-methane organic compound (TNMOC) concentration exceeds a pre-determined trigger level. The canister sample is then analyzed in a lab in a later time. In the Auto-GC method, an online GC runs in a “continuous” mode with a sampling and analysis cycle of 1 h. Within the cycle hour, samples are collected only during the first 40 min.A new approach of Auto-GC running in trigger mode is developed in this study. This new approach uses Auto-GC but operates it in a trigger mode similar to the triggered canister sampling method. Compared to the triggered canister sample method, this system provides near real-time speciated VOC data, which are critical for responding to a high VOC concentration episode. Although the canister system generally costs less, its cost advantage may diminish if trigger events are frequent and the monitoring duration is long. Compared to continuous Auto-GC, triggered GC has its niche—it is better for capturing transient plumes with a small footprint. The continuous GC either misses a transient plume if the plume does not arrive at the sampling site during the sampling cycle or flattens the plume concentration peak by dilution with non-plume air sample.Field experience with this system for fenceline VOC monitoring is presented. The sampling and calibration strategy for trigger mode operation is described. The chromatograph retention time drift issues are discussed. The system performance is evaluated, including the method detection limit, precision and accuracy. The trigger mode configuration for VOC fenceline or near source monitoring in this work proved effective for local and transient plume identification.  相似文献   

12.
This paper describes the process of determining the presence of volatile organic compounds in air emissions from industrial wastewater treatment plants (WWTP). The analytical method, based on thermal desorption-gas chromatography-mass spectrometry, was developed to simultaneously determine of 99 volatile organic compounds (VOCs) in air samples. This method is rapid, environmentally-friendly (since no organic solvents are used to extract the analytes) and compatible with a large range of thermally stable polar and apolar compounds. The target VOCs were selected on the basis of their occurrence in real samples and their adverse effects on the environment and human health. To cover the wide range of target compounds, multisorbent tubes filled with Tenax TA and Carbograph 1TD were used. Method validation showed good repeatabilities, low detection limits, a high linear range and good recoveries. At a fixed sample volume of 600?mL no significant losses for any of the target compounds were found in the samples. Stability during storage indicated that samples must be keep refrigerated at 4°C and analysed within three days of collection. Real samples were taken from air emissions of an industrial wastewater treatment plant located in the Southern Industrial Area of Tarragona (Spain) with the aim of studying its contribution as a source of atmospheric VOCs. This WWTP collects wastewater from several chemical factories which produce isocyanates, polyurethanes, chlorinated organics and functional chemicals among other products. Samples from the collecting tank after the primary sedimentation showed higher VOC concentrations than samples from the secondary treatment tank. The most abundant VOCs found in these emissions are included in the USEPA List of Hazardous Air Pollutants. The highest values correspond to acrylonitrile (up to 1843?µg?m?3) and styrene (up to 573.70?µg?m?3). The levels of chloroform, 1,4-dioxane, ethylbenzene, 1,2,3-trimethylbenzene and 1,4-diethylbenzene were also high.  相似文献   

13.
The aim of the present study was to develop a new analytical method of chromatographic determination of two important markers of ETS exposure: nicotine and 3-vinylpyridine (3-ethenylpyridine, 3-EP) in mainstream (MS) and sidestream (SS) smoke of one single cigarette and in indoor air using direct solid phase extraction combined with gas chromatography. The method can be utilised for both nicotine and 3-EP determination in SS and MS of one single cigarette as well as it allows for a precise determination of compound distribution in indoor air. The application of the same analytical method for both kinds of samples allows anticipating indoor air distribution of both analysed compounds in a very precise way. The precision of the method (calculated as a relative standard deviation) was 9.78% for nicotine and 2.67% for 3-EP; whereas the accuracy (evaluated by a recovery study conducted at three different levels) was 70.1 and 87.3%, respectively. The limit of detection was 0.06 µg per cigarette for both nicotine and 3-EP. The method was evaluated by determining the compounds of interest in two commercially available brands of cigarettes as well as in the reference cigarettes 3R4F and also in indoor air polluted with tobacco smoke. Determined levels of compounds of interest in MS varied from 586 to 772 (nicotine) µg per cigarette and from 3.5 to 10.7 (3-EP) µg per cigarette. In SS smoke the level varied from 14,370 to 22,590 (nicotine) µg per cigarette and from 185 to 550 (3-EP) µg per cigarette, whereas levels in indoor air polluted with tobacco smoke varied from 50.1 to 157.3 (nicotine) µg m?3and from 7.7 to 20.8 (3-EP) µg m?3.  相似文献   

14.
This article reviews recent literature on the analysis of several contaminants related to the industrial development in indoor air in the framework of the REACH project. In this second part, the attention is focused on emergent contaminants and biocides. Among these chemicals, phthalates, polybrominated and phosphate flame retardants, fragrances, pesticides, as well as other emerging pollutants, are increasing their environmental and health concern and are extensively found in indoor air. Some of them are suspected to behave as priority organic pollutants (POPs) and/or endocrine disrupting compounds (EDC), and can be found both in air and associated to the suspended particulate matter (PM) and settled dust. Main literature considered for this review is from the last ten years, reporting analytical developments and applications regarding the considered contaminants in the indoor environment. Sample collection and pretreatment, analyte extraction or desorption, clean-up procedures, determination techniques, and performance results are summarized and discussed.  相似文献   

15.
A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography–mass spectrometry (GC–MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30 min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods.  相似文献   

16.
This paper reports the results of a study carried out with solid sorbents in order to establish the optimum procedure for sampling and determination of diphenylamine (DPA), the most widely used post-harvest chemical in apples, in the indoor air of apple storage buildings. Different sorbents (Amberlite XAD-2, Amberlite XAD-4, Supelpak 2, Florisil, and the octadecyl silica bonded sorbent, C-18) were evaluated for their capacity to efficiently retain DPA under different air sampling and storage conditions, whereas a desorption study of all sorbents tested was also performed to optimise a simple extraction procedure using low volumes of organic solvents. In general all sorbents produced acceptable results for DPA air sampling whereas DPA was recovered easily by the use of low volumes of both ethyl acetate and acetone from all sorbents studied thus making DPA a suitable analyte to be used in methods of indoor air analysis for multi-organic pollutants. However, the best results (analytical features, recovery results, and stability results during storage) were obtained by the use of Supelpak 2 as a sorbent for DPA active sampling. Limits of Quantification (LOQs) for the GC-NPD system ranged from 1.0 to 2.0?µg?m?3 for 120 and 60?L air sampled, respectively. The developed air sampling procedure and analytical methodology was applied with success in the field to measure DPA residues in indoor air of two apple storage plants in Greece and results were further used to calculate the occupational inhalation exposure to DPA and consequently risk characterisation. Since DPA was detected in indoor air (at concentrations ranged from 1.6 to 580?µg?m?3), there is no zero occupational risk for workers. However, the inhalation exposure of workers to DPA estimated in this study is far below the Acceptable Operator Exposure Level recently reviewed by the European Union and far below the critical exposure level for haematotoxicity systemic effect observed in carcinogenicity studies in rats for long-term inhalation exposure to DPA.  相似文献   

17.
The distribution of volatile organic compounds (VOC) in urban-influenced air and river waters was investigated. The aquatic VOC were extracted with the closed-loop stripping technique (CLST) and the airborne compounds were studied using two methods, charcoal and polyurethane foam adsorption. In both types of samples, C1-C5 alkylbenzenes and n-alkanes constitute the two major VOC groups, and the presence of these groups indicates a predominance of petroleum products in these two environmental compartments. Chlorinated compounds such as polychlorobenzenes, polychloronaphthalenes and hexachlorobutadiene are abundant in water samples, whereas tetrachloroethene is the predominant chlorinated airborne VOC. The compounds collected with each sampling system can be described in terms of ranges of volatility. These ranges (expressed as mmHg vapour pressure at 25 degrees C) can be defined approximately as 140 (methylcyclopentane)-0.65 (n-undecane) for charcoal, 5.1 (n-nonane)-0.000061 (n-docosane) for polyurethane foam and 29 (toluene)-0.000029 (n-eicosane) for the CLST. Parallel air sampling with charcoal and polyurethane foam is therefore needed to cover a VOC range similar to that afforded by the CLST in water.  相似文献   

18.
Two types of passive samplers differing in their geometry (OVM 3500 by 3M, ORSA 5 by Dräger) were compared with respect to their suitability for typical environmental indoor and outdoor VOC concentrations. Benzene, toluene, o-, m-, p-xylene, ethylbenzene, tetrachloroethene, trichloroethene, nonane and ethyl acetate were representatively analyzed by dual-column capillary gas chromatography with tandem ECD-FID detection. There was a good correlation between the results obtained with OVM 3500 and ORSA 5 monitors indicating that both monitors can be used for this kind of application. The ratio between the results for indoor air sampling with OVM 3500 and ORSA 5 monitors was between 0.89 and 1.14 showing no systematic variation. For outdoor air sampling the ratio was between 1.06 and 1.26 indicating that the results obtained with OVM 3500 monitors were slightly higher. Reproducibility was slightly better when using ORSA 5 monitors. But, due to the higher sampling rates which are a result of the larger cross-sectional area, signal-to-noise ratios obtained with OVM 3500 monitors were between six to nine times higher than those of ORSA 5 samplers. Blank values of the unexposed samplers were comparable for both sampler types. As a consequence, detection limits were by a factor of 1.5 to 4 better for OVM 3500 monitors.  相似文献   

19.

Background

A sampling campaign of indoor air was conducted to assess the typical concentration of indoor air pollutants in 8 National Libraries and Archives across the U.K. and Ireland. At each site, two locations were chosen that contained various objects in the collection (paper, parchment, microfilm, photographic material etc.) and one location was chosen to act as a sampling reference location (placed in a corridor or entrance hallway).

Results

Of the locations surveyed, no measurable levels of sulfur dioxide were detected and low formaldehyde vapour (< 18???g?m-3) was measured throughout. Acetic and formic acids were measured in all locations with, for the most part, higher acetic acid levels in areas with objects compared to reference locations. A large variety of volatile organic compounds (VOCs) was measured in all locations, in variable concentrations, however furfural was the only VOC to be identified consistently at higher concentration in locations with paper-based collections, compared to those locations without objects. To cross-reference the sampling data with VOCs emitted directly from books, further studies were conducted to assess emissions from paper using solid phase microextraction (SPME) fibres and a newly developed method of analysis; collection of VOCs onto a polydimethylsiloxane (PDMS) elastomer strip.

Conclusions

In this study acetic acid and furfural levels were consistently higher in concentration when measured in locations which contained paper-based items. It is therefore suggested that both acetic acid and furfural (possibly also trimethylbenzenes, ethyltoluene, decane and camphor) may be present in the indoor atmosphere as a result of cellulose degradation and together may act as an inferential non-invasive marker for the deterioration of paper. Direct VOC sampling was successfully achieved using SPME fibres and analytes found in the indoor air were also identified as emissive by-products from paper. Finally a new non-invasive, method of VOC collection using PDMS strips was shown to be an effective, economical and efficient way of examining VOC emissions directly from the pages of a book and confirmed that toluene, furfural, benzaldehyde, ethylhexanol, nonanal and decanal were the most concentrated VOCs emitted directly from paper measured in this study.  相似文献   

20.
The variations of concentrations of volatile halocarbons (CHCl3, CCl4, CH2Cl—CH2Cl, CCl3—CH3, CHCl—CCl2, and CCl2=CCl2) in rural and urban air are demonstrated by two series of air sampling carried out in Southern Germany. The interpretation of the changes in concentrations for the individual compounds is based on specific local input for the chlorinated solvents and on changing weather conditions during the sampling periods.Dedicated to Professor J. F. K. Huber on the occasion of his 65th birthday  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号