1.
A simple and rapid gradient RP HPLC method for simultaneous separation and determination of venlafaxine and its related substances in bulk drugs and pharmaceutical formulations has been developed. As many as four process impurities and one degradation product of venlafaxine have been separated on a Kromasil KR100-5C18 (4.6 mm x 250 mm; particle size 5 microm) column with gradient elution using 0.3% diethylamine buffer (pH 3.0) and ACN/methanol (90:10 v/v) as a mobile phase. The column was maintained at 40 degrees C and the eluents were monitored with photo diode array detection at 225 nm. The chromatographic behaviour of all the compounds was examined under variable compositions of different solvents, temperatures, buffer concentrations and pH. The method was validated in terms of accuracy, precision and linearity as per ICH guidelines. The inter- and intraday assay precision was < 4.02% (%RSD) and the recoveries were in the range of 96.19-101.14% with %RSD < 1.15%. The correlation coefficients (r2) for calibration curves of venlafaxine as well as impurities were in the range of 0.9942-0.9999. The proposed RP-LC method was successfully applied to the analysis of commercial formulations and the recoveries of venlafaxine were in the range of 99.32-100.67 with %RSD <0.58%. The method could be of use not only for rapid and routine evaluation of the quality of venlafaxine in bulk drug manufacturing units but also for the detection of its impurities in pharmaceutical formulations. Forced degradation of venlafaxine was carried out under thermal, photo, acidic, basic and peroxide conditions and the acid degradation products were characterized by ESI-MS/MS, 1H NMR and FT-IR spectral data.  相似文献   

2.
An RP-HPLC method for the simultaneous separation and determination of olanzapine (OLZ) and its process impurities in bulk drugs and pharmaceutical formulations was developed. The separation was accomplished on Inertsil ODS 3V (4.6 mm x 250 mm; particle size 5 microm) column using 0.2 M ammonium acetate (pH = 4.50) and ACN as mobile phase in gradient elution mode. The analytes were monitored by a photo diode array (PDA) detector set at 254 nm and the flow rate was kept at 1.0 mL/min. The chromatographic behavior of all the compounds was examined under variable compositions of different solvents, buffer concentrations, and pH. The method was validated in terms of accuracy, precision, and linearity. Four unknown process impurities observed consistently during the analysis of different batches of OLZ were isolated and characterized by ESI-MS/MS, (1)H NMR, and FT-IR. The proposed RP-HPLC method was successfully applied to the analysis of commercial formulations. The method could be of use not only for rapid and routine evaluation of the quality of OLZ in bulk drug manufacturing units but also for the detection of its impurities in pharmaceutical formulations.  相似文献   

3.
A simple and rapid gradient reversed-phase high-performance liquid chromatographic method for simultaneous separation and determination of paracetamol and its related compounds in bulk drugs and pharmaceutical formulations has been developed. As many as nine process impurities and one degradation product of paracetamol have been separated on a Symmetry C18 column (4.6 x 250 mm i.d., particle size 5 microm) with gradient elution using 0.01 M potassium dihydrogen phosphate buffer (pH 3.0) and acetonitrile as mobile phase and photo diode array detection at 215 nm. The chromatographic behavior of all the compounds was examined under variable compositions of different solvents, temperatures, buffer concentrations and pH values. The correlation coefficients for calibration curves for paracetamol as well as impurities were in the range of 0.9951 - 0.9994. The proposed RP-LC method was successfully applied to the analysis of commercial formulations; the recoveries of paracetamol were in the range of 99-101%. The method could be of use not only for rapid and routine evaluation of the quality of paracetamol in bulk drug manufacturing units but also for detection of its impurities in pharmaceutical formulations.  相似文献   

4.
In this study, the RP-HPLC method was investigated for the separation of citalopram and its four impurities by use of statistical experimental design. Initially, the influence of different experimental conditions (buffer pH, flow rate, and column temperature) on the chromatographic behavior of citalopram and its four impurities was investigated by use of partial least squares regression (PLSR) and multilayer perceptron (MLP) artificial neural networks (ANNs) trained by back-propagation. The developed models and the corresponding response surface plots were used to select the optimal HPLC conditions, buffer pH 7.0, flow rate 1.0 mL/ min, and column temperature 25 degrees C, for an efficient separation of citalopram and its four impurities. The elaborated HPLC method was found to be linear, specific, sensitive, precise, accurate, and robust. Retention times of citalopram and its impurities, obtained with the developed HPLC method, and the computed molecular parameters of the examined compounds were used in a quantitative structure retention relationship (QSRR) study. The PLSR and ANN algorithms were applied for the development of the QSRR methods. The MLP-two layers-ANN-QSRR model with root mean square error of prediction 0.105 and r(2) (observed versus predicted) 0.978 was selected. Since many different reaction conditions are applied for the synthesis of citalopram, different impurities and degradation products can be formed. Therefore, the developed QSRR model can be extended to the prediction of the retention times with the other citalopram impurities, degradation products, and metabolites.  相似文献   

5.
ABSTRACT: BACKGROUND: A simple, specific, and fast stability indicating reverse phase liquid chromatographic method was established for instantaneous determination of moxifloxacin and prednisolone in bulk drugs and pharmaceutical formulations. RESULTS: Optimum chromatographic separations among the moxifloxacin, prednisolone and stressinduced degradation products were achieved within 10 minutes by use of BDS Hypersil C8 column (250 X 4.6 mm, 5 mum) as stationary phase with mobile phase consisted of a mixture of phosphate buffer (18 mM) containing 0.1% (v/v) triethylamine, at pH 2.8 (adjusted with dilute phosphoric acid) and methanol (38:62 v/v) at a flow rate of 1.5 mL min-1. Detection was performed at 254 nm using diode array detector. The method was validated in accordance with ICH guidelines. Response was a linear function of concentrations over the range of 20-80 mug mL-1 for moxifloxacin (r2 [greater than or equal to] 0.998) and 40-160 mug mL-1 for prednisolone (r2 [greater than or equal to] 0.998). The method was resulted in good separation of both the analytes and degradation products with acceptable tailing and resolution. The peak purity index for both the analytes after all types of stress conditions was [greater than or equal to] 0.9999 indicated a complete separation of both the analyte peaks from degradation products. The method can therefore, be regarded as stabilityindicating. CONCLUSIONS: The developed method can be applied successfully for simultaneous determination of moxifloxacin and prednisolone in pharmaceutical formulations and their stability studies.  相似文献   

6.
A systematic Quality by Design approach was employed for developing an isocratic reversed‐phase liquid chromatographic technique for the estimation of ropinirole hydrochloride in bulk drug and pharmaceutical formulations. LiChrospher RP 18‐5 Endcapped column (25 cm × 4.6 mm id) at ambient temperature (25 ± 2°C) was used for the chromatographic separation of the drug. The screening of factors influencing chromatographic separation of the active pharmaceutical ingredient was performed employing fractional factorial design to identify the influential factors. Optimization of the selected factors was carried out using central composite design for selecting the optimum chomatographic conditions. The mobile phase employed was constituted of Solvent A/Solvent B (65:35 v/v) (Solvent A [methanol/0.05 M ammonium acetate buffer, pH 7, 80:20 v/v] and Solvent B [high performance liquid chromatography grade water]) and used at 0.6 mL/min flow rate, while UV detection was performed at 250 nm. Linearity was achieved in the drug concentration range 5–100 µg/mL (R= 0.9998) with limits of detection and quantification of 1.02 and 3.09 µg/mL, respectively. Method validation was performed as per ICH guidelines followed by forced degradation studies, which indicated good specificity of the developed method for detecting ropinirole hydrochloride and its possible degradation products in the bulk drug and pharmaceutical formulations.  相似文献   

7.
A sensitive, reliable and reproducible HPLC method with electrochemical detection (HPLC-ECD) has been developed for the separation and quantification of levodopa methyl ester (LDME) and its impurities such as levodopa (l-DOPA), 3-methoxytyrosine (MTS) and l-tyrosine (TS) in bulk drug and pharmaceutical dosage form. The separation was performed on an LC18 column by isocratic elution with methanol-acetonitrile-50 mm potassium dihydrogen phosphate (8:2:90, v/v/v) containing 5 mm sodium 1-hexanesulfonate, 5 mm EDTA and 5 mm sodium chloride, adjusted with phosphoric acid to a pH of 3.2 as mobile phase. The correlation coefficients of linear regression for LDME, L-DOPA, MTS and TS were more than 0.999. The detection limits for L-DOPA, MTS and TS were 3.15, 2.04 and 2.88 ng/mL, respectively. The precision was checked in terms of F-test variance ratio using potentiometric titration as reference. The separation of dopa methyl ester enantiomers by chiral chromatography is also described. This method is capable of separating the two enantiomers with a selection of 1.4 and a resolution of 8.4. Both methods were found to be stable and useful in the quality control of the bulk material and formulations.  相似文献   

8.
Research studies have been carried out to develop a chromatographic and densitometric method suitable for identification and determination of tramadol and impurities. In addition, the stability of tramadol in solutions was investigated, including an effect of solution pH, temperature and incubation time. In the first instance the conditions for identification and quantitative determination of tramadol and impurities in pharmaceutical preparations were established. The separation was performed on silica gel-coated chromatographic plates (HPTLC) using two mobile phases: (I) chloroform-methanol-glacial acetic acid (9:2:0.1, v/v/v); (II) chloroform-toluene-ethanol (9:8:1, v/v/v). The UV densitometry was carried out at lambda = 270 nm. The developed method is of high sensitivity and low detection and determination limits ranging from 0.044 to 0.35 microg. For individual constituents the recovery ranges from 93.23 to 99.66%. The next step was to evaluate the stability of tramadol and determine a method of decomposition under various experimental conditions. It was found that tramadol decomposes in various ways in acidic and basic environments producing (1RS)-[2-(3-methoxyphenyl)cyclohex-2-enyl]-N,N-dimethylmethanamine (imp. B) and (1RS, 2RS)-2-[(dimethylamino)methyl]-1-(3-methoxyphenyl)cyclohexanol (imp. cis-T) or imp. cis-T, respectively.  相似文献   

9.
A simple and fast capillary electrophoretic method has been developed for the enantioselective separation of citalopram and its main metabolites, namely N-desmethylcitalopram and N,N-didesmethylcitalopram, using beta-cyclodextrin (beta-CD) sulfate as the chiral selector. For method optimisation several parameters were investigated, such as CD and buffer concentration, buffer pH, and capillary temperature. Baseline enantioseparation of the racemic compounds was achieved in less than 6 min using a fused-silica capillary, filled with a background electrolyte consisting of a 35 mM phosphate buffer at pH 2.5 supplemented with 1% w/v beta-CD sulfate and 0.05% w/v beta-CD at 25 degrees C and applying a voltage of -20 kV. A fast separation method for citalopram was also optimized and applied to the analysis of pharmaceutical formulations. Racemic citalopram was resolved in its enantiomers in less than 1.5 min using short-end injection (8.5 cm, effective length) running the experiments in a background electrolyte composed of a 25 mM citrate buffer at pH 5.5 and 0.04% w/v beta-CD sulfate at a temperature of 10 degrees C.  相似文献   

10.
The present paper describes stability indicating reverse phase high-performance liquid chromatography (RP-HPLC) assay method for nitazoxanide in bulk drugs. The developed method is also applicable for the related substances determination in bulk drug. The drug substance was subjected to stress conditions of hydrolysis, photolysis and thermal degradation. The considerable degradation of nitazoxanide was observed under base and peroxide hydrolysis. The drug was found to be stable in other stress conditions attempted. The chromatographic separation of the drug was achieved on reversed-phase C-18 column. Eluents were monitored on photo-diode array detector at a wavelength of 240 nm. The mobile phase was aqueous 0.005 M tetra butyl ammonium hydrogen sulphate and acetonitrile (45:55, v/v). In the developed HPLC method, resolution between nitazoxanide and its potential impurities, namely Imp-A (5-nitro-1,3-thiazol-2-amine), Imp-B (N-(5-nitro-1,3-thiazol-2-yl) acetamide) and Imp-C (2-{[(5-nitro-1,3-thiazol-2-yl) amino] carbonyl} phenyl 2-(acetyloxy) benzoate) was found greater than three. The developed RP-HPLC method was validated with respect to response function, accuracy, precision, specificity, stability of analytical solutions and robustness. Also to determine related substances and assay determination of nitazoxanide that can be used to evaluate the quality of regular production samples. The developed method can also be conveniently used for the assay determination of nitazoxanide in pharmaceutical formulations.  相似文献   

11.
Aspirin (ASP) and cilostazol (CST) are used as a combination in pharmaceutical formulations for treatment of strokes. Salicylic acid (SAL) is considered to be one of the main synthesis impurities and a degradation product of ASP. On the other hand, the main related impurities of CST are CST related A, B, and C (CST-RA, CST-RB, and CST-RC), respectively. Furthermore, as high efficiency and less elution are the basic requirements of high-speed chromatographic separation, so, a comparative study of two simple, precise, and accurate reversed-phase HPLC and UPLC methods was developed and validated for simultaneous estimation of ASP and CST in bulk and capsules in the presence of SAL, CST-RA, CST-RB, and CST-RC. A Eurospher II C18 (250?×?4.6?mm2, 5?µm) for HPLC method and an Agilent Zorbax Eclipse Plus C18 (50?×?2.1?mm2, 1.8?µm) for UPLC method were used. A gradient mobile phase of 20?mM anhydrous KH2PO4 buffer solution (containing 0.2% triethylamine (TEA), v/v) with pH adjusted to 2.9 using orthophosphoric acid (solution A) and acetonitrile (solution B) mixed in different proportions for HPLC and UPLC methods was prepared. Flow rate was set to 1.0 and 0.3?mL min?1 for HPLC and UPLC methods, respectively, and the detection was performed for both methods at 210?nm. It worth noting that the proposed UPLC-DAD assay exhibited relatively much more precision, sensitivity, specificity, and economic and chromatographic separation superiority than proposed HPLC-UV assay. Both developed methods were compared with reference methods to prove its applicability and are suitable for purity assessment of ASP and CST in bulk and capsules.  相似文献   

12.
A simple and rapid high-performance liquid chromatographic method for the separation and determination of process-related impurities of sildenafil was developed. The separation was achieved on a reversed-phase C18 column using acetonitrile-0.05 M potassium dihydrogen orthophosphate (70:30 v/v) as a mobile solvent at a flow rate of 1.0 ml/min and UV detection at 230 nm. The method was used not only for quality assurance, but also for monitoring the chemical reactions during the synthesis of sildenafil. It was found to be specific, precise and reliable for the determination of all process-related impurities of sildenafil in bulk drugs and formulations.  相似文献   

13.
A simple isocratic liquid chromatographic method was developed for determination of lopinavir from its related impurities and assay for the first time. This method involves the use of a C(8) (Symmetry Shield RP8, 150 x 4.6 mm, 5 microm) column. The method was validated over the range of limit of quantitation (LOQ) to 120% of impurity specification limit and LOQ to 150% of working concentration for assay. The mobile phase consisted of a mixture of 50 mM of potassium phosphate buffer, acetonitrile and methanol in the ratio of 40:50:10. The flow rate was set at 1.0 mL/min with UV detection monitored at 210 nm. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The developed method was validated for linearity, range, precision, accuracy and specificity. This method was successfully applied for content determination of lopinavir in pharmaceutical formulations. The method can be conveniently used in a quality control laboratory for routine analysis for assay and related substances as well for the evaluation of stability samples of bulk drugs and pharmaceutical formulations.  相似文献   

14.
A simple, precise, and rapid stability-indicating reversed-phase column liquid chromatographic (RP-LC) method has been developed and subsequently validated for simultaneous estimation of simvastatin (SIM) and ezetimibe (EZE) from their combination drug product. The proposed RP-LC method utilizes a LiChrospher 100 C18, 5 microm, 250 x 4.0 mm id column at ambient temperature; optimum mobile phase consisting of acetonitrile-water-methanol (60 + 25 + 15, v/v/v) with apparent pH adjusted to 4.0 +/- 0.1; mobile phase flow rate of 1.5 mL/min; and ultraviolet detection at 238 nm. SIM, EZE, and their combination drug product were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. There were no other coeluting, interfering peaks from excipients, impurities, or degradation products due to variable stress conditions, and the method is specific for the estimation of SIM and EZE in the presence of degradation products. The described method was linear over the range of 1-80 and 3-80 microg/mL for SIM and EZE, respectively. The mean recoveries were 99.17 and 100.43% for SIM and EZE, respectively. The intermediate precision data were obtained under different experimental conditions, and the calculated value of the coefficient of variation was found to be less than the critical value. The proposed method can be useful in the quality control of bulk manufacturing and pharmaceutical dosage forms.  相似文献   

15.
A simple, precise, and rapid stability-indicating reversed-phase column liquid chromatographic (RP-LC) method has been developed and subsequently validated for simultaneous estimation of atorvastatin (ATV) and ezetimibe (EZE) from their combination drug product. The proposed RP-LC method utilizes a LiChrospher 100 C18, 5 microm, 250 x 4.0 mm id column at ambient temperature; the optimum mobile phase consists of acetonitrile-water-methanol (45 + 40 + 15, v/v/v) with apparent pH adjusted to 4.0 +/- 0.1; mobile phase flow rate of 1.0 mL/min; and UV detection at 250 nm. ATV, EZE, and their combination drug product were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. There were no other coeluting, interfering peaks from excipients, impurities, or degradation products due to variable stress conditions, and the method is specific for the estimation of ATV and EZE in the presence of degradation products. The response was linear over the concentration range of 1-80 microg/mL for ATV and EZE. The mean recoveries were 99.27 and 98.5% for ATV and EZE, respectively. The intermediate precision data were obtained under different experimental conditions, and the calculated value of the coefficient of variation was found to be less than the critical value. The proposed method can be useful in the quality control of bulk manufacturing and pharmaceutical dosage forms.  相似文献   

16.
A gradient reversed-phase liquid chromatographic assay was developed for the quantitative determination of the non-steroidal anti-inflammatory drug valdecoxib. The developed method was also applicable to the determination of related substances in the bulk drug. Forced degradation studies were performed on bulk valdecoxib using acid (2.0 N hydrochloric acid), base (2.0 N sodium hydroxide), oxidation (6.0% v/v hydrogen peroxide), water hydrolysis, heat (60 °C) and photolysis. Mild degradation was observed using alkaline conditions and considerable degradation observed during oxidative stress. Chromatographic separation of process-related impurities and degradation products was achieved using a 5 micron Zorbax SB-CN LC column. The mobile phase consisted of aqueous potassium dihydrogen phosphate (pH 3.0) and acetonitrile. Stressed samples were assayed using the developed LC method and determination of the mass balance accounted for 99.5%, thus indicating the suitability of this stability-indicating method. Linearity, accuracy, precision and robustness have also been evaluated.  相似文献   

17.
An isocratic reverse phase liquid chromatographic (RP-LC) assay method has been developed for the quantitative determination of nateglinide and its related components namely imp-1 and imp-2 in bulk drug and in pharmaceutical dosage form, used for the treatment of type II diabetes mellitus. The developed method is stability indicating and also can be used for stability testing. The chromatographic separation was achieved on C-8, 150 × 4.6 mm, 3.5 μm stationary phase. The LC method employs solution A as mobile phase. Solution A contains a mixture of phosphate buffer pH 3.0: acetonitrile (50:50 v/v). The flow rate was 1.0 mL min−1 and the detection wavelength was 210 nm. In the developed LC method the resolution between nateglinide and its potential impurities namely imp-1 and imp-2 was found to be greater than 5.0. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid medium, alkaline medium and oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.2%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

18.
An RP-HPLC method for simultaneous separation and quantification of pantoprazole and its five main impurities in pharmaceutical formulations was developed and validated. The separation was accomplished on a Zorbax Eclipse XDB C18 column (5 microm particle size, 150 x 4.6 mm id) using a gradient with mobile phase A [buffer-acetonitrile (70 + 30, v/v)], and mobile phase B [buffer-acetonitrile (30 + 70, v/v)]. The buffer was 0.01 M ammonium acetate solution with addition of 1 mL triethylamine/L of the solution, adjusted to pH 4.5 with orthophosphoric acid. The eluent flow rate was 1 mL/min, the temperature of the column was 30 degrees C, and the eluate was monitored at 290 nm. Linearity (r = 0.999), recovery (97.6-105.8%), RSD (0.55-1.90%), and LOQ (0.099-1.48 microg/mL) were evaluated and found to be satisfactory. The proposed method can be used for simultaneous identification and quantification of the analyzed compounds in pharmaceutical formulations.  相似文献   

19.
A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of deferasirox, its related impurities in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at 245 nm. The mobile phase consisted of buffer, acetonitrile and methanol (50:45:5, v/v) delivered at a flow rate of 1.0 mL min?1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 3.0 by using orthophosphoric acid. In the developed LC method the resolution (R s ) between deferasirox and its four potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.999 for deferasirox and its four impurities. This method was capable to detect all four impurities of deferasirox at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all four impurities and for deferasirox was found to be within 2.0% RSD. The method showed good and consistent recoveries for deferasirox in bulk drugs (98.3–101.1%), pharmaceutical dosage forms (100.2–103.1%) and for its all the four impurities (99.7–102.1%). The test solution was found to be stable in methanol for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.95%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

20.
A novel reversed-phase HPLC method for the simultaneous determination of active component terbinafine, its one impurity 1-methylaminomethylnaphtalene and three degradation products, β-terbinafine, Z-terbinafine and 4-methyl-terbinafine occurring in pharmaceutical formulations after long-term stability tests, was developed and validated using propylparaben as an internal standard.The chromatographic separation was performed on a NUCLEOSIL 100-5-CN column, mobile phase for separation of all compounds consisted of a mixture of tetrahydrofurane, acetonitrile and citrate buffer pH 4.50 (10:20:70, v/v/v). The analysis time was less than 32 min at flow-rate of 0.8 ml min−1. UV detection was performed at 226 nm. The method was validated and system suitability parameters were investigated. Method robustness and short-term standard solution stability were verified. Limits of detection for terbinafine degradation products/impurity were from 0.023 to 0.098 μg ml−1, limits of quantitation were from 0.078 to 0.327 μg ml−1. The method was applicable for routine determination of terbinafine and all its found impurities of similar structure with sufficient selectivity, precision and accuracy.  相似文献   