Several procedures using high-performance liquid chromatography with photodiode-array detection have been developed to create phytochemical and toxicological profiles of phenylalkylamine derivatives in biological samples (e.g. plant materials and urine). Mescaline-containing cactus samples were extracted with basic methanol, using methoxamine as internal standard; the extraction and clean-up of urine samples were performed on cation-exchange solid-phase extraction columns. The extracts were separated on a 3-micron ODS column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was performed at 198 or 205 nm; peak identity and homogeneity were ascertained by on-line scanning of the UV spectra from 190 to 300 nm. The detection limit of phenylalkylamine derivatives in urine and cactus material was 0.026-0.056 micrograms/ml and 0.04 micrograms/mg, respectively. Following a single oral dose of 1.7 mg/kg methylenedioxymethylamphetamine (MDMA) the concentrations found in urine ranged from 1.48 to 5.05 micrograms/ml MDMA and 0.07-0.90 micrograms/ml methylenedioxyamphetamine (a metabolite of MDMA). The mescaline content of the cactus Trichocereus pachanoi varied between 1.09 and 23.75 micrograms/mg.  相似文献   

2.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

3.
A simple, specific and rapid reversed-phase high-performance liquid chromatographic (HPLC) procedure for sotalol determination is described requiring small plasma volumes. The high recovery of sotalol from plasma and the high precision of measurement obviate the need for an internal standard. Plasma samples (300 microliters) were deproteinised with 50 microliters of 70% (w/w) perchloric acid in disposable glass tubes. After vortex-mixing and centrifugation, 30 microliters of 4 M K2HPO4 were added followed by gentle shaking. A 20-microliters aliquot was then injected (by autosampler) for HPLC analysis. Chromatography was performed on a glass-lined 250 mm x 4 mm 5-micron C18 steel column. The mobile phase was 6% (v/v) acetonitrile in 0.08 M KH2PO4 buffer (pH 4.6). The flow-rate was 0.8 ml/min. Detection was by fluorescence with excitation and emission wavelengths at 235 and 310 nm, respectively. The retention time for sotalol was 7.1 min. Calibration was linear from 0.16 to 10 micrograms/ml in plasma (r greater than 0.999 for detector response to sotalol). The minimum concentration for quantitation was 0.08 micrograms/ml [within assay coefficient of variation (C.V.) less than 5%]. Recovery was near quantitative (greater than 98%) and replicate (intra-assay precision was less than 5% C.V.). Analysis of samples (n = 10) at concentrations of 0.42 and 4.2 micrograms/ml gave mean values of 0.44 and 4.3 micrograms/ml, respectively. The inter-assay C.V. values were 4.5 and 2.2%, respectively. Other clinically used antiarrhythmic drugs did not interfere. This assay can be performed using other commercial C18 analytical columns by suitable adjustment of mobile phase flow-rate and acetonitrile composition.  相似文献   

4.
A gas chromatographic procedure was developed for the determination of methanol in small-volume whole blood samples. Samples (100-200 microliters) were prepared by protein precipitation, with direct injection of the supernatant on a wide-bore capillary column. The recovery of methanol and acetonitrile (the internal standard) was approximately 90% and did not vary with sample volume. The assay was linear from 2 micrograms/ml (the limit of detection) through 1000 micrograms/ml and was highly reproducible (intra-day coefficient of variation less than 2.5%). Assay performance was assessed following exposure of rats to methanol. The results indicate that the present procedure is suitable for studies of methanol disposition in small rodent species.  相似文献   

5.
Methods for determining concentrations of a new morpholino anthracycline MX2.HCl and its metabolites in biological samples using reversed-phase high-performance liquid chromatography and fluorescence detection are described. The limits of detection were less than 1 ng/ml for all compounds after extraction from 0.5 ml of plasma using C18 Sep-Pak cartridges and consecutive solvent extraction. The recoveries from rat plasma ranged from 72.0 to 89.3%. The peak-height ratio of the fluorescence intensities of these compounds versus internal standard showed a linear correlation for concentrations up to at least 500 ng/ml in the plasma (correlation coefficient r greater than 0.999). The within-day and between-day precisions of this assay were in the range 0.8-8.7% (n = 5) and 2.0-3.5% (n = 5), respectively. The concentrations of these compounds in the blood and urine can be also determined by a slight modification of the extraction procedure.  相似文献   

6.
Determination of tris(hydroxymethyl)aminomethane (tromethamine) in human plasma involved derivatization of the amino and hydroxyl groups with a ultraviolet-absorbing chromophore followed by extraction into an organic phase. Reversed-phase high-performance liquid chromatography with gradient elution was used for the separation of the analyte from the internal standard (2,3-butanediol). The assay was linear in the range 1.0-1000.0 micrograms/ml of plasma and the coefficient of variation varied between 9.6 and 16.3% whereas the accuracy varied between 90 and 108%. The limit of detection for the assay was 0.282 micrograms/ml. Stability of tris(hydroxymethyl)aminomethane in human plasma frozen at -20 degrees C was studied over a period of three month and the data indicated no significant change.  相似文献   

7.
A gas chromatographic method is described for the quantitation of methacrylonitrile in serum. Methacrylonitrile was extracted from rat serum with diethyl ether and then quantified using a gas chromatograph equipped with a flame ionization detector and a 60-m megabore column coated with polyethylene glycol polymer. The recoveries obtained following a one-step extraction with diethyl ether varied from 60% at 3.2 micrograms/ml to 70% at 80 micrograms/ml. The coefficient of variation for the analysis ranged from 2.5% at 400 micrograms/ml to 15.0% at 3.2 micrograms/ml.  相似文献   

8.
A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid-solid extraction, esterified with boron trifluoride-methanol, and analysed by capillary gas chromatography and selected-ion monitoring. Hexadeuterium-labelled hexahydrophthalic acid was used as the internal standard. The precision was 4% at 0.7 microgram/ml and 5% at 0.07 microgram/ml. The recovery of the acid for the overall method was 101% at 0.07 micrograms/ml of urine (with a coefficient of variation of 4%) and 95% at 0.7 microgram/ml (coefficient of variation 2%). The limit of detection was 20 ng/ml urine.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic (HPLC) method for the analysis of 1,2-diethyl-3-hydroxypyridin-4-one (CP94, I) and its 2-(1-hydroxyethyl) metabolite (II) in rat blood is described. I, II and the internal standard, 1-propyl-2-ethyl-3-hydroxypyridin-4-one (CP95, III) were extracted into dichloromethane (3 x 5 ml, with the addition of 1 g of sodium chloride) from blood (0.25 ml plus 0.75 ml of pH 7.0 morpholinopropanesulphonic acid buffer). Extractability approached 100% for I and III, and approximately 65% for II under these conditions. Chromatographic analysis was carried out using a Hypercarb porous graphitised carbon HPLC column (10 cm x 0.46 cm). The mobile phase was 14:86 (v/v) acetonitrile-NaH2PO4 buffer (10 mM, containing 2 mM EDTA, pH adjusted to 3 with phosphoric acid) and detection was by ultraviolet at 280 nm. Calibration curves were linear (correlation coefficient greater than 0.99) and reproducible over the concentration range 0-80 micrograms/ml and the coefficient of variation was less than 16% even at low (1 microgram/ml) concentrations. The minimum quantifiable level was 0.5 microgram/ml for both I and II.  相似文献   

10.
A simple, accurate and precise isocratic reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of p-chloronitrobenzene (p-CNB) in rat plasma. A plasma sample was deproteinized with methanol containing the internal standard (p-bromonitrobenzene). The resulting methanol eluate obtained after centrifugation was filtered and injected into a high-performance liquid chromatograph (50 microliters each). A column packed with 5 microns octadecylsilane (ODS) spherical particles was used with isocratic elution of methanol-water (45:55, v/v) at a flow-rate of 1.0 ml/min. The compounds were detected by ultraviolet absorbance at 280 nm. The retention times of p-CNB and the internal standard were 12.5 and 15.5 min, respectively, at a column oven temperature of 30 degrees C. The results were linear from 0.05 to 100 micrograms/ml (r = 0.999), and the detection limit was 0.01 microgram/ml. The relative error and the coefficient of variation on replicate assays were less than 7 and 10%, respectively, for all concentrations studied. The overall recoveries of p-CNB were between 97 and 105%. Plasma samples could be stored for up to one month at -20 degrees C.  相似文献   

11.
A high-performance liquid chromatographic method was developed for monitoring the serum concentration of streptomycin. The method includes clean-up using a Sep-Pak C18 cartridge and quantitation using dihydrostreptomycin as an internal standard. Streptomycin and dihydrostreptomycin were separated by reversed-phase ion-pair chromatography on LiChrosorb RP-18 and detected by UV absorption (195 nm). The calibration graph of serum streptomycin concentration was linear over the range 5-50 micrograms/ml. Streptomycin was added to serum at the level of 20.0 micrograms/ml and its concentration was determined to be 18.9 micrograms/ml with a coefficient of variation of 2.07% (n = 5). The clinical application of this method was confirmed by comparison with fluorescence polarization immunoassay.  相似文献   

12.
Two high-performance liquid chromatographic methods are described for the assay of theophylline in plasma. Both allowed the separation of theophylline from the caffeine metabolites, theobromine and 1,7-dimethylxanthine. Method A, using 8-chlorotheophylline as internal standard, involved back extraction of theophylline from organic extract with 0.1 M sodium hydroxide. Method B used generally accepted solvent extraction followed by evaporation and beta-hydroxyethyltheophylline as internal standard. High-performance liquid chromatographic analyses were performed on reversed-phase phenyl columns (25 X 0.46 and 25 X 0.41 cm) using 20% methanol in 20 mM phosphate buffer at pH 5.6 for Method A and 2% acetonitrile and 8% methanol in 20 mM phosphate buffer for Method B. The column effluent was monitored at UV 273 nm. Standard curves for both Methods A and B were fitted by linear regression (r greater than 0.999) in the concentration range of 0.05-50 micrograms/ml. Either method was selective, accurate and reproducible over the concentration range 0.08-26 micrograms/ml. However, compared with Method B, Method A provided significant advantages in terms of simplicity, speed and efficiency.  相似文献   

13.
In an effort to characterize the pharmacokinetic behavior of the antimitotic agent N-desacetylcolchicine a selective, sensitive high-performance liquid chromatographic method was developed for the determination of N-desacetylcolchicine, demecolcine and colchicine in serum or urine. To 0.5 ml of serum or 0.1 ml of urine diluted to 0.5 ml were added 50 microliters demecolcine (2 micrograms/ml) which serves as the internal standard. The sample was extracted using a C2 reversed-phase solid extraction column. N-Desacetyl-colchicine, colchicine and the internal standard were eluted from the column with methanol. The combined eluates were evaporated to dryness and the residue was reconstituted with water. The reconstituted sample was injected into a C18 reversed-phase column and eluted using a mobile phase consisting of 0.1 M potassium dihydrogenphosphate, 5 mM 1-pentanesulfonic acid in methanol and acetonitrile with a final pH of 6.0, at a flow rate of 1.5 ml/min. N-Desacetylcolchicine, colchicine and the internal standard were detected using a variable-wavelength ultraviolet detector at 254 nm. The limit of detection was 0.4 ng/ml for desacetylcolchicine and 4.0 ng/ml for colchicine. The method is linear over a concentration range of 1.0-200 ng/ml. The method has been shown to be a rapid, reliable method to monitor N-desacetylcolchicine levels in clinical trials in cancer patients.  相似文献   

14.
A sensitive method has been developed for the detection and quantitative determination of thiodiglycol in blood, plasma and urine. Samples were extracted from Clin Elut columns and cleaned up on C18 Sep-Pak cartridges (blood, plasma) or Florisil Sep-Pak cartridges (urine). Tetradeuterothiodiglycol was added to the sample prior to extraction as internal standard. Thiodiglycol was converted to its bis-(pentafluorobenzoate) derivative and analysed by capillary gas chromatography-electron-capture negative-ion chemical ionisation mass spectrometry using selected ion monitoring. Levels of thiodiglycol down to 1 ng/ml (1 ppb) could be detected in 1-ml spiked blood and urine samples; calibration curves were linear over the range 5- or 10-100 ng/ml. Blood and urine samples from a number of control subjects were analysed for background levels of thiodiglycol. Concentrations up to 16 ng/ml were found in blood, but urine levels were below 1 ng/ml.  相似文献   

15.
Two different reversed-phase high-performance liquid chromatographic methods for the determination of aniracetam (I) and its metabolite N-anisoyl-GABA (II) in human plasma are described. The procedure for I involves direct injection of plasma samples spiked with the internal standard on a clean-up column followed by reversed-phase chromatography on a C18 column. The limit of quantification was 5 ng/ml, using a 200-microliters specimen of plasma. The mean inter-assay precision of the method up to 800 ng/ml was 3%. The procedure for II involved liquid-liquid extraction of II and the internal standard from plasma with ethyl acetate, and reversed-phase chromatography on a C18 column. The limit of quantification was 50 ng/ml using a 0.5-ml plasma specimen. The mean inter-assay precision up to 50 micrograms/ml was 6%. The applicability and accuracy of the methods were demonstrated by the analysis of over 1000 plasma samples from two bioavailability studies in healthy volunteers.  相似文献   

16.
Lamotrigine is an investigational anticonsulvant drug undergoing clinical trials. A simultaneous assay was developed to quantitate lamotrigine and its major metabolite, lamotrigine 2-N-glucuronide, from guinea pig whole blood. The extraction procedure and reversed-phase high-performance liquid chromatographic (HPLC) assay employed sodium dodecylsulfate (SDS) as an ion-pairing reagent to selectively separate lamotrigine and lamotrigine 2-N-glucuronide from endogenous blood components, other anti-convulsant drugs, and their metabolites. The mobile phase was composed of acetonitrile-50 mM phosphoric acid (pH 2.2) containing 10 mM SDS (33:67, v/v), and components were detected at 277 nm. The total coefficients of variance (C.V.) for the blood assay were less than or equal to 9.4% for lamotrigine (0.25-20.0 micrograms/ml) and less than or equal to 13.4% for the glucuronide metabolite (0.25-10.0 micrograms/ml). Separate assays for lamotrigine and its glucuronide in urine were developed. In order to quantitate low levels of lamotrigine in guinea pig urine, lamotrigine was extracted with tert.-butyl methyl ether-ethyl acetate (1:1). The total C.V. for lamotrigine quantitation in urine was less than or equal to 7.5% (0.10-10.0 micrograms/ml). For the determination of lamotrigine 2-N-glucuronide, urine was diluted with an SDS-phosphoric acid buffer (1:4) and injected directly onto the HPLC system, total C.V. less than or equal to 4.2% (0.5-50 micrograms/ml).  相似文献   

17.
A relatively simple method for extraction of free fatty acids from cerebrospinal fluid with aminopropyl bonded-phase columns, and the estimation of palmitic acid (C16:0) and stearic acid (C18:0) concentrations by high-performance liquid chromatographic analysis is described. The values of C16:0 and C18:0 in patients with non-neurological disorders lie within a narrow range, with a mean (+/- S.D.) of 4.02 +/- 0.33 micrograms/ml for C16:0 and 2.72 +/- 0.39 micrograms/ml for C18:0.  相似文献   

18.
A sensitive and precise method for the determination of nicorandil, a new anti-anginal medication, is reported. The method involves solid-phase extraction of the drug and internal standard using Bond-Elut C18 extraction columns, reversed-phase high-performance liquid chromatography on a Zorbax-Phenyl column and detection with photoconductivity and ultraviolet detection in series. Photoconductivity, performed with the Tracor 965 photoconductivity detector, provided a limit of detection of 2 ng/ml in plasma (between-day coefficient of variation of 15%) but the linear range of response was limited to only about 100 ng/ml. Ultraviolet detection in series with the photoconductivity detector extended the linear range of the analytical system to 1000 ng/ml (coefficient of variation 4.4%). The utility of the method is demonstrated in a dog pharmacokinetic study in which a 5-mg intravenous dose was compared to a 10-mg oral solution dose in six beagle dogs. The oral solution was absorbed rapidly, achieving an average maximum concentration of 857 ng/ml in 11.2 min. The absolute bioavailability of nicorandil in dogs in this study was determined to be 84.2%.  相似文献   

19.
A reversed-phase high-performance liquid chromatographic assay with ultraviolet detection at 243 nm has been developed for the quantitative determination of methylprednisolone (MP) and methylprednisolone 21-[8-[methyl-(2-sulfoethyl)amino]-8-oxooctanoate] sodium salt (MPSO) in human urine following therapeutic doses in humans. The assay procedure involves stabilization of urine samples by addition of disodium ethylenediaminetetraacetic acid (Na2EDTA) and ion-pair extractions of MPSO using tetraethylammonium chloride (TEACl) as the counter ion. After extracting both drugs and internal standard into chloroform, the extract was evaporated to dryness under nitrogen. The resulting residue was reconstituted in 200-500 microliters of mobile phase and chromatographed on an IBM C18 reversed-phase column (5 microns). The mobile phase was a mixture of water-acetonitrile-isopropanol (71.2:18.8:10.0, v/v) containing 75 microliters of 0.1 M hydrochloric acid and 0.450 g of TEACl per liter. Propyl p-hydroxybenzoate was used as an internal standard. The extraction efficiencies of MP and MPSO were greater than 90% using the ion-pairing agent TEACl. The chromatographic responses were linear up to about 200 micrograms/ml for MP and 80 micrograms/ml for MPSO and had sufficient precision and accuracy to provide quantitative data from human urine. The assay detection limit was about 8 ng/ml for MP and 25 ng/ml for MPSO in human urine. Stability studies in urine indicated that without Na2EDTA stabilization and at room temperature, rapid degradation of MPSO occurred in urine. Addition of EDTA to the urine specimen and storage at -70 degrees C increased the stability of MPSO, and little or no degradation was observed in urine stored for more than 60 days. The method has been used in the simultaneous determination of MP and MPSO in urine specimens obtained from a single-dose tolerance study of MPSO in normal male volunteers.  相似文献   

20.
A method is described for the determination of urinary 4,4'-methylenedianiline (MDA) by high-performance liquid chromatography (HPLC). MDA was extracted from hydrolyzed urine using C18 solid-phase extraction columns. The extract was analyzed by reversed-phase HPLC with electrochemical detection at a cell potential of 0.8 V. The method was very sensitive (detection limit 2.5 micrograms/l) and quantitation using 4,4'-ethylenedianiline as an internal standard correlated well with results by gas chromatography-mas spectrometry. Run-to-run precision (n = 25) averaged 8.9%. In analysis of more than 160 potentially exposed workers, MDA was detected in less than 20% of the urines and concentrations ranged up to 210 micrograms MDA per g of creatinine.  相似文献   