首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A stability-indicating reversed-phase liquid chromatographic (RPLC) method has been established for analysis of ramipril (RAM) and moexipril hydrochloride (MOEX.HCl) in the presence of the degradation products generated in studies of forced decomposition. The drug substances were subjected to stress by hydrolysis (0.1 m NaOH and 0.1 m HCl), oxidation (30% H2O2), photolysis (254 nm), and thermal treatment (80 °C). The drugs were degraded under basic and acidic conditions and by thermal treatment but were stable under other stress conditions investigated. Successful separation of the drugs from the degradation products was achieved on a cyanopropyl column with 40:60 (v/v) aqueous 0.01 m ammonium acetate buffer (pH 6)–methanol as mobile phase at a flow rate of 1 mL min−1. Detection was by UV absorption at 210 nm. Response was a linear function of concentration over the range 5–50 μg mL−1 (r > 0.9995), with limits of detection and quantitation (LOD and LOQ) of 0.04 and 0.09 μg mL−1, respectively, for RAM and 0.014 and 0.32 μg mL−1, respectively, for moexipril. The method was validated for specificity, selectivity, solution stability, accuracy, and precision. Statistical analysis proved the method enabled reproducible and selective quantification of RAM and MOEX as the bulk drug and in pharmaceutical preparations. Because the method effectively separates the drugs from their degradation products, it can be used as stability-indicating.  相似文献   

2.
In the present study, a novel, fast and simple liquid chromatographic method was developed and validated for the simultaneous determination of rosiglitazone and metformin in pharmaceutical preparations. The separation was achieved on a phenyl column (250 × 4.6 mm i.d., 5 μm) using a mobile phase composed of acetonitrile:10.0 mM phosphate buffer pH 5.5 (70:30, v/v). The flow rate was 1 mL min−1. UV detection was performed at 245 nm and verapamil was used as internal standard. The developed method was validated in terms of stability, specificity, sensitivity, linearity, accuracy, precision and robustness. The limit of quantification was 0.02 μg mL−1 for both drugs. The method developed was successfully applied to the simultaneous determination of rosiglitazone and metformin in pharmaceutical preparations. The results were compared to two methods reported in the literature and no significant difference was found statistically.  相似文献   

3.
S. Tatar Ulu 《Chromatographia》2006,64(7-8):447-451
A simple, selective, precise and accurate reversed phase-HPLC assay for analysis of gemfibrozil in tablets was developed and validated. Separation and quantification were achieved on a Phenomenex C18 column under isocratic conditions using a mobile phase (methanol:water, 80:20, v/v) maintained at 1.1 mL min−1. UV-detection was at 280 nm. Atorvastatin was selected as an internal standard. The standard curves were linear over the range of 0.5–3.0 μg mL−1 (r > 0.999). The limits of detection and quantification were 0.20 and 0.51 μg mL−1, respectively. The recoveries for gemfibrozil were above 99.01%. The intra-day and inter-day precision (RSD) for gemfibrozil were below 1.74 and 1.83%, respectively. No chromatographic interferences from the tablet excipients were found. The results of the developed procedure in tablets were compared with those of the reference method to assess gemfibrozil content. Statistical comparison of the results with the reference method using spectrofluorimetric method showed excellent agreement and proved no significant difference in accuracy and precision. This HPLC method is fast and simple for the analysis of gemfibrozil in pharmaceutical preparations.  相似文献   

4.
Summary A high-performance liquid chromatographic method, with 9-anthryldiazomethane as derivatizing agent, has been developed for the simultaneous determination ofN-carbamoyl aspartate andl-dihydroorotate in serum. Sample preparation for 1 mL serum was by simple liquid-liquid extraction and then derivatization. The compounds were separated on a Luna C18(2) column by use of a gradient prepared from acetonitrile and 10 mM sodium acetate buffer, pH 6.0, and fluorimetric detection was performed at excitation and emission wavelengths of 365 nm and 412 nm, respectively. The response was found to be linearly dependent on concentration between 0.8 and 60 μg mL−1 forl-dihydrooratate and between 0.9 and 90 μg mL−1 forN-carbamoyl aspartate; the mean recovery rates were 50 and 51%, respectively. The limits of detection and quantification were 0.33 μg mL−1 and 0.6 μg mL−1, respectively, forl-dihydroorotate and 0.4 μg mL−1 and 0.7 μg mL−1 forN-carbamoyl aspartate. This method can be used to assess accumulation ofN-carbamoyl aspartate andl-dihydroorotate in body fluids in situations where cellular pyrimidine de novo synthesis is impaired.  相似文献   

5.
H. B. Li  F. Chen 《Chromatographia》2001,54(3-4):270-273
Summary A novel method for the simultaneous determination of twelve water- and fat-soluble vitamins has been established by high-performance liquid chromatography with diode array detection. The vitamins were analyzed on a μBondapak C18 column (300 × 3.9 mm, 10 μm) with methanol-KH2PO4 buffer (0.1 M, pH 7.0)-water as mobile phase in a gradient. The linearity of calibration graphs was compound-dependent and the detection limits ranged from 0.02 μg mL−1 to 0.5 μg mL−1. The method was successfully applied to determine vitamins in pharmaceutical preparations. The recoveries were from 95.1% to 103% and the relative standard deviations were in the range of 0.9% to 4.5%.  相似文献   

6.
Summary A simple, low-cost, sensitive and selective HPLC method was developed for the determination of phenazopyridine in human plasma. The method employs UV detection of phenazopyridine and of the internal Standard at 2 different wavelengths. Calibration curves were linear over a large dynamic range, i.e., within 0.05–10.0 μg mL−1 with limit of quantification of 0.05 μg mL−1, and a limit of detection of 0.01 μg mL−1.  相似文献   

7.
A sensitive and reliable ion-paired high-performance liquid chromatographic method has been established for the simultaneous quantification of six major active ingredients, namely baicalin, baicalein, wogonin, oxysophocarpine, oxymatrine and matrine in the Chinese herbal preparation, Sanwu-Huangqin-Tang. HPLC analyses were performed on a Phenomenex luna C18 column with mobile phase of methanol–acetonitrile–aqueous phosphoric acid at a flow rate of 0.9 mL min−1. The complete separation was achieved within 35 min for the six target constituents. A good linear regression relationship between peak-areas and concentrations was obtained over the range of 12.10–242.0 μg*mL−1 for baicalin, 5.05–101.0 μg*mL−1 for baicalein, 0.95–19.0 μg*mL−1 for wogonin, 2.75–55.0 μg*mL−1 for oxysophocarpin, 2.75–55.0 μg*mL−1 for oxymatrine and 4.90–98.0 μg*mL−1 for matrine, respectively. The repeatability was evaluated by intra- and inter-day assays with relative standard deviation (RSD) being less than 5.1%. The recoveries, measured at three concentration levels, varied from 93.8 to 102.1%. The assay was successfully applied for determination of six bioactive compounds in Sanwu-Huangqin-Tang. The interaction of chemical constituents was observed when the herbs were used in compatibility. The results indicated that the developed assay method was rapid, accurate and could be readily utilized as a quality control method for Sanwu-Huangqin-Tang.  相似文献   

8.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

9.
A simple reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of the antiepileptic drugs (AEDs) zonisamide (ZNS), primidone (PRI), lamotrigine (LTG), phenobarbital (PB), phenytoin (PHT), oxcarbazepine (OXC), and carbamazepine (CBZ) and two of their active metabolites, monohydroxycarbamazepine (MHD) and carbamazepine 10,11-epoxide (CBZE) in human plasma. Plasma (100 μL) was pretreated by deproteinization with 300 μL methanol containing 20 μg mL−1 propranolol hydrochloride as internal standard. HPLC was performed on a C8 column (4.6 mm × 250 mm; particle size 5 μm) with methanol–acetonitrile–0.1% trifluoroacetic acid, 235:120:645 (v/v), as mobile phase at a flow rate of 1.5 mL min−1. ZNS, OXC, and CBZ were monitored by UV detection at 235 nm, and PRI, LTG, MHD, PB, PHT, and CBZE by UV detection at 215 nm. Relationships between response and concentration were linear over the concentration ranges 1–80 μg mL−1 for ZNS, 5–50 μg mL−1 for PRI, 1–25 μg mL−1 for LTG, 1–50 μg mL−1 for MHD, 5–100 μg mL−1 for PB, 1–10 μg mL−1 for CBZE, 0.5–25 μg mL−1 for OXC, 1–50 μg mL−1 for PHT, and 1–25 μg mL−1 for CBZ. Intra-day and inter-day reproducibility were adequate (coefficients of variation were ≤11.6%) and absolute recovery ranged from 95.2 ± 6.13 to 107.7 ± 7.76% for all the analytes; for the IS recovery was 98.69 ± 1.12%. The method was proved to be accurate, reproducible, convenient, and suitable for therapeutic monitoring of the nine analytes.  相似文献   

10.
In this article, novel chemiluminescence mechanisms between norfloxacin and cerium(IV) in an acidic medium were studied. Chemiluminescence spectra of the present system were recorded observing three maximum emissions at about 475 nm, 550 nm, and 620 nm, respectively. The results indicate that the chemiluminescence peaks located at 475 nm and 620 nm can be ascribed to the emission of a singlet oxygen, while the chemiluminescence emission at 550 nm occurred in course of the reaction between acidic cerium(IV) and the phenolic intermediate. Under optimum conditions, the chemiluminescence intensity was linear with the concentration of norfloxacin over the range of 2.0 × 10−8−1.0 × 10−5 g mL−1 and the detection limit of 1.0 × 10−8 g mL−1 (S/N = 3). The relative standard deviation was 1.94 % for a 4.0 × 10−7 g mL−1 norfloxacin solution considering eleven repeated measurements. The present chemiluminescence system was successfully applied in the determination of norfloxacin in pharmaceutical preparations and concentration-time profiles in urine.  相似文献   

11.
A cheap, simple and rapid sample preparation method has been developed for quantification of ulifloxacin, the active metabolite of prulifloxacin in human plasma, by HPLC with fluorescence detection using lemefloxacin as the internal standard. One-step protein precipitation with 10% perchloric acid (2:1, v/v) on a 200 μL sample was used. The separation was performed at 30 °C on a C18 column using an eluent of acetonitrile-0.5% triethylamine buffer. The compounds were monitored at λ ex of 280 nm, λ em of 425 nm. The calibration curve for ulifloxacin in human plasma was linear over the range 0.01–1.00 μg mL−1. The lower limit of quantification is 0.01 μg mL−1. The intra- and inter-day precision ranged from 3.0 to 6.7%, respectively. The method had been used for clinical pharmacokinetic studies of prulifloxacin formulation product after oral administration to healthy volunteers. Jun Wen and Zhenyu Zhu have equal contribution to this work.  相似文献   

12.
An integrated solid-phase spectrophotometry–FIA method is proposed for simultaneous determination of the mixture of saccharin (1,2-benzisothiazol-3(2H)-one-1,1-dioxide; E-954) (SA) and aspartame (N-l-α-aspartyl-l-phenylalanine-1-methyl ester; E-951) (AS). The procedure is based on on-line preconcentration of AS on a C18 silica gel minicolumn and separation from SA, followed by measurement, at λ=210 nm, of the absorbance of SA which is transiently retained on the adsorbent Sephadex G-25 placed in the flow-through cell of a monochannel FIA setup using pH 3.0 orthophosphoric acid–dihydrogen phosphate buffer, 3.75×10–3 mol L−1, as carrier. Subsequent desorption of AS with methanol enables its determination at λ=205 nm. With a sampling frequency of 10 h−1, the applicable concentration range, the detection limit, and the relative standard deviation were from 1.0 to 200.0 μg mL−1, 0.30 μg mL−1, and 1.0% (80 μg mL−1, n=10), respectively, for SA and from 10.0 to 200.0 μg mL−1, 1.4 μg mL−1, and 1.6% (100 μg mL−1, n=10) for AS. The method was used to determine the amounts of aspartame and saccharin in sweets and drinks. Recovery was always between 99 and 101%. The method enabled satisfactory determination of blends of SA and AS in low-calorie and dietary products and the results were compared with those from an HPLC reference method.  相似文献   

13.
Summary A simple and rapid liquid chromatographic method has been developed for the determination of therapeutic levels of piperacillin (I) and ceftazidime (II) in human plasma. Plasma and p-propionamidophenol (internal standard) were precipitated with methanol (I) or 20% trichloroacetic acid (II). The supernatant was analysed on a 5 μm Spherisorb ODS C18 column with acetonitrile-0.05 M phosphate buffer pH 3.8 as mobile phase and ultraviolet detection at 254 nm. The calibration graph was linear from 10 to 250 μg mL−1, for (I), and from 5 to 200 μg mL−1 for (II). Intra and inter-day CV did no exceed 2.29% for (I), and were 10.76–11.13%–2.00–5.62 for (II) at concentrations of 10 μg mL−1 and 250 μg mL−1.  相似文献   

14.
Summary A sensitive and rapid routine HPLC method is proposed for quantitative estimation of morphine hydrochloride and hydromorphone hydrochloride in pharmaceutical dosage forms. The drugs were chromatographed on a C18 reversed-phase column; the mobile phase was acetonitrile-water, 35:65 (v/v), containing sodium dodecyl sulphate (0.5%, w/v), as ion pairing reagent, and acetic acid (0.4% v/v). Detection was at 230 nm. The optimized method was validated and linearity (r>0.999), precision, and accuracy were found to be acceptable within the concentration ranges 86–124 μg mL−1 for morphine hydroloride and 60–180 μg mL−1 for hydromorphone hydrochloride. The method is being used to investigate the stability of morphine hydrochloride and hydromorphone hydrochloride in solution used for intramuscular injection.  相似文献   

15.
A simple, rapid and selective RP-HPLC method was developed and validated for the determination of ketorolac and five piperazinylalkyl ester prodrugs. A binary isocratic mobile phase composed of a mixture of 65:35 (v/v) 0.02 M phosphate buffer (pH 5.4) and acetonitrile was used on a C18 column (125 × 4 mm, 5 μm). The injection volume was 25 μL and the detection wavelength was 314 nm and the flow rate was 1.5 mL min−1. The method exhibited excellent linearity with R 2 of no less than 0.999 and intra-assay and inter-assay precision that were less than the maximum amount allowed according to Horwitz equation. The accuracy was found to be within the allowed ±15%. The limits of detection for the analytes were between 0.060 and 0.220 μg mL−1 and the limits of quantification were between 0.183 and 0.667 μg mL−1. This method was used successfully for the study of the solubility, stability and partition coefficients of piperazinylalkyl ester prodrugs of ketorolac.  相似文献   

16.
Summary Capillary GC of metal chelates of diethyl dithiocarbamate (DDTC) was examined on a methylsilicone DB-1 column, (25 meter, 0.2 mm. i.d) with a film thickness of 0.25 μm. Elution was carried out at the initial column temperature of 180°C and programmed at 5°C min−1 to 260°C. Detection was by FID or ECD. Symmetrical peaks with base line separation were obtained with the metal chelates of copper(II), nickel(II), cobalt(III), manganese(II) and chromium(III). The ECD gave better sensitivity than the FID with a linear calibration range of 5–50 μg mL−1 and detection limits 2.0–6.0 μg mL−1, corresponding to 111–333 pg of metal ion reaching the detector. The method was applied to the determination of metal ions in water and pharmaceutical preparations with a coefficient of variation (CV) within 4.0%. When compared with a standard flame AAS method the results revealed no significant difference.  相似文献   

17.
Summary This paper describes an HPLC method for the determination of meropenem in human plasma. The method uses solid phase extraction (SPE) of the samples and has good sensitivity, precision and accuracy. The limit of quantification in plasma samples is 0.02 μg mL−1. Calibration curves were linear over a large dynamic range, namely within 0.02–50 μg mL−1. The method was applied to the determination of meropenem levels in patients receiving meropenem, as a single dose or at steady state.  相似文献   

18.
A simple, rapid, and precise method is developed for the quantitative simultaneous estimation of telmisartan and ramipril in combined pharmaceutical dosage form. A chromatographic separation of the two drugs was achieved with an ACE 5 C18, 25-cm analytical column using buffer–acetonitrile (55:45 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted 3.0 with trifluoroacetic acid. The instrumental settings are flow rate of 1.5 mL min−1, column temperature at 30 °C, and detector wavelength of 215 nm using a photodiode array detector. The resolution between ramipril and telmisartan were found to be more than 5. Theoretical plates for ramipril and telmisartan were 13,022 and 6,629. Tailing factor for ramipril and telmisartan was 0.94 and 0.98. Telmisartan, ramipril and their combination drug product were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of telmisartan and ramipril is obtained using photodiode array detector, in the stressed sample chromatograms, demonstrated the specificity of the method for their estimation in presence of degradants. The described method shows excellent linearity over a range of 20–400 μg mL−1 for telmisartan and 2.5–50 μg mL−1 for ramipril. The correlation coefficient for telmisartan and ramipril are 1. The relative standard deviation for six measurements in two sets of each drug in tablets was always less than 2%. The proposed method was found to be suitable and accurate for quantitative determination and the stability study of telmisartan and ramipril in pharmaceutical preparations.  相似文献   

19.
A multisyringe flow injection analysis method for the determination of uranium in water samples was developed. The methodology was based on the complexation reaction of uranium with arsenazo (III) at pH 2.0. Uranium concentrations were spectrophotometrically detected at 649 nm using a light emitting diode. Under the optimized conditions, a linear dynamic range from 0.1 to 4.0 μg mL−1, a 3σ detection limit of 0.04 μg mL−1, and a 10σ quantification limit of 0.10 μg mL−1 were obtained. The reproducibility (%) at 0.5, 2.5, and 4.0 μg mL−1 was 2.5, 0.9, and 0.6%, respectively (n = 10). The interference effect of some ions was tested. The proposed method was successfully applied to the determination of uranium in water samples.  相似文献   

20.
A sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry (LC–ESI-MS) has been developed and validated for identification and quantification of mitiglinide in human urine. A simple liquid–liquid extraction procedure was followed by separation on a C18 column with gradient elution, and detection using a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. The method was tested using six different batches of urine. Linearity was established for the mitiglinide concentrations in the range 0.005–1.0 μg mL−1, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. Intra- and inter-day precision (as RSD, %) was below 10% and accuracy for mitiglinide ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.002 μg mL−1 for 500 μL urine. The proposed method enables unambiguous identification and quantification of mitiglinide in pre-clinical and clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号