首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Summary A liquid chromatographic procedure is proposed for the determination of procaine and tetracaine in plasma samples with direct injection. The method uses a Spherisorb octadecylsilane ODS-2 C18 analytical column and a micellar mobile phase containing 0.15 M sodium dodecyl sulphate, 0.5% triethylamine at pH 2.5 and 10% propanol. The UV detection was carried out at 300 nm. Plasma sample preparation required only adequate dilution with the mobile phase before injection into the chromatographic system. The proposed method allows the determination of procaine and tetracaine in plasma at therapeutic levels.  相似文献   

2.
Four quinolones (danofloxacin, difloxacin, flumequine and marbofloxacin) were determined in milk and egg samples by a simplified high-performance liquid chromatographic procedure using a micellar mobile phase. No extraction was needed to precipitate the proteins from the matrices since they were solubilised in micelles. The only pretreatment steps required were homogenisation, dilution and filtration before injecting the sample into the chromatographic system. An adequate resolution of the quinolones was achieved by a chemometrics approach where retention was modelled as a first step using the retention factors in only five mobile phases. Afterwards, an optimisation criterion was applied to consider the position and shape of the chromatographic peaks. Analytical separation involved a C18 reversed-phase column, a hybrid micellar mobile phase of 0.05 M sodium dodecyl sulphate, 10% (v/v) butanol and 0.5% (v/v) triethylamine buffered at pH 3 and fluorimetric detection. Quinolones were eluted in less than 15 min without the protein band or other endogenous compounds from the food matrices interfering. The calculated relevant validation parameters, e.g., decision limit (CC(α)), detection capability (CC(β)), repeatability, within-laboratory reproducibility, recoveries and robustness, were acceptable and complied with European Commission Decision 2002/657/EC. Finally, the proposed method was successfully employed in quantifying the four quinolones in spiked egg and milk samples.  相似文献   

3.
A micellar reversed-phase liquid chromatographic procedure was developed for the control of five water-soluble vitamins, B (nicotinamide), B1 (thiamine), B2 (riboflavin), B6 (pyridoxine and pyridoxamine), in multivitamin pharmaceutical formulations (capsules, pills and syrups). Optimization procedure includes studies about the composition of the mobile phase (sodium dodecyl sulphate and the modifiers propanol, butanol or pentanol), flow-rate and temperature. Chromatographic analysis of all vitamins was carried out using a single mobile phase of 0.1 M SDS-4% (v/v) pentanol at pH 3, in a C18 column in isocratic mode, and UV-detection at 270, 290 and 325 nm. The flow-rates selected were 1.0 ml/min in the interval 0 to 6 min, and 2.0 ml/min until the end of the chromatogram and temperature was 45 degrees C. In the micellar liquid chromatographic system, the samples were injected without pretreatment, and the analysis time was below 12 min. Repeatabilities and intermediate precision were achieved according to ICH, and were below 5%. When the method is applied to real samples, the amount found with respect to the declared compositions were within the 91-105% range. These results were similar to those obtained with a conventional 60:40 (v/v) methanol-water mixture for some of the vitamins, but with the advantage of use a single mobile phase for the analyses of the five vitamins, with direct injection of the samples and reduced toxicity, flammability, environmental impact and cost of the micellar-pentanol solutions.  相似文献   

4.
Two biogenic amines, tryptamine and tyramine, and their precursors, tryptophan and tyrosine, were determined by a liquid chromatographic procedure. A hybrid micellar mobile phase of sodium dodecyl sulphate (SDS) and 1-propanol, a C18 column and electrochemical detection were used. A pH study in the range of 3-9 was performed and pH 3 was finally selected in accordance with resolution and analysis time. Oxidation potential was also checked in the range 0.6-0.9V: the maximum area obtained in all those potentials was at 0.8V, which was selected to carry out the analysis using a sequence of pulsed amperometric detection waveform. The four compounds were resolved using a mobile phase of 0.15M SDS-5% 1-propanol with an analysis time of 16 min. Repeatabilities and intermediate precision were evaluated at three different concentrations for each compound with RSD values lower than 2.6 and 4.8%, respectively. Limits of detection and quantification were also obtained within the 10-40 and 33-135 ng/ml ranges, respectively. Finally, the applicability of the procedure was tested in several types of wine and no matrix effect was observed. The possibility of direct sample introduction simplifies and greatly expedites the treatments with reduced cost, improving the accuracy of the procedures.  相似文献   

5.
Acetaminophen is determined in serum and urine samples by a rapid, sensitive, and precise chromatographic method without any pretreatment step in a C18 column using a pure micellar mobile phase of 0.02M sodium dodecyl sulfate at pH 7. Acetaminophen is eluted in less than 5 min with no interference of the protein band. The use of electrochemical and UV detection is compared. Linearities (r > 0.999), as well as intra- and interday precision, are studied in the validation of the method. Limits of detection (LOD) are also calculated to be 0.56, 0.83, and 0.74 ng/mL in micellar solution, serum, and urine using electrochemical detection. The developed micellar liquid chromatographic method is useful for the quantitation of acetaminophen in serum and urine. Recoveries in the biological matrices are in the 98-107% range and results are compared with those obtained using a reference method. Drug excretion (in urine) and serum distribution are studied in several healthy volunteers, and no interference from metabolites is found. The developed procedure can be applied in routine analyses, toxicology, and therapeutic monitoring.  相似文献   

6.
The use of micellar liquid chromatography for the determination of diuretics in urine by direct injection of the sample into the chromatographic system is discussed. The retention of the urine matrix at the beginning of the chromatograms was observed for different sodium dodecyl sulphate (SDS) mobile phases. The eluent strengths of a hybrid SDS-methanol micellar mobile phase for several diuretics were compared and related to the stationary phase/water partition coefficient with a purely micellar mobile phase. The urine band was appreciably narrower with a mobile phase of 0.05 M SDS-5% methanol (v/v) at 50 degrees C (pH 6.9). With this mobile phase the determination of bendroflumethiazide and chlorthalidone was adequate. Acetazolamide, ethacrynic acid, furosemide, hydrochlorothiazide and probenecid were overlapped by the urine matrix, and the retention of amiloride and triamterene was too long.  相似文献   

7.
A rapid and sensitive method for the quantitative determination of folylpolyglutamate hydrolase activity in crude tissue extracts was developed. The procedure is based on high-performance liquid chromatographic separation of folate analogue mono- and polyglutamates on a reversed-phase column using sodium dodecyl sulfate in water as the mobile phase. Interfering substances in tissue extracts were removed by gel filtration on centrifugally-eluted mini-columns of Sephadex G-25 prior to incubation of polyglutamate substrate with tissue extract hydrolase. Reactions were terminated by denaturation of the enzyme in sodium dodecyl sulfate, which subsequently served as the micellar solvent system for chromatographic separation of substrate from reaction products.  相似文献   

8.
Summary An HPLC procedure for the determination of six local anesthetics, bupivacaine, lidocaine, mepivacaine, procaine, propanocaine and tetracaine, in pharmaceutical silane ODS-2 C18 analytical column and spectrophotometric detection at 230 nm were used. The chromatographic tographic behaviour of local anesthetics with different micellar eluents of sodium dodecyl sulphate (SDS) is described. Selection of the adequate composition of the micellar mobile phase (SDS and 1-propanol concentrations) for the analysis of pharmaceuticals was studied. Adequate retention was achieved with an eluent containing 0.15 M SDS +10% 1-propanol at pH 3. Application of the proposed method to the analysis of eight pharmaceutical formulations gave recoveries between 93 and 100.2% of the values declared by the manufacturers. The proposed procedure for the determination of local anesthetics is rapid, reliable and free from interferences.  相似文献   

9.
The chromatographic behavior of cortisol and cortisone using a micellar medium of sodium dodecyl sulphate (SDS) as surfactant, a Hypersil C18 (150- x 3.2-mm i.d., 5 microm) column, a flow rate of 0.5 mL/min, and UV absorbance detection at 245 nm is described. The effect of several organic modifiers and the surfactant concentration on the separation is studied. A mobile phase of 18 mM SDS and 8.3% tetrahydrofuran allows for the separation of cortisol and cortisone up to baseline. These results are also achieved by applying a bivariant optimization method. The proposed method is sensitive, reproducible, and selective. In addition, it is less expensive than conventional high-performance liquid chromatography methods for cortisol and cortisone. The method is applied to the determination of cortisol and cortisone in urine samples of rugby players before and after stress for doping control purposes.  相似文献   

10.
A simple and reliable liquid chromatographic procedure is described for the determination of trazodone in pharmaceutical formulations and urine samples. The optimized procedure uses fluorimetric detection, a C18 column and a micellar mobile phase of sodium dodecyl sulfate (SDS) and 1-butanol. The mobile phase selected for use was 0.2M SDS and 8% 1-butanol fixed at pH 3 with phosphate buffer. The total analysis time was 10 min. For the analysis of urine samples, one great advantage of the method is that no extraction step is required. The quantification limit was 9.5 ng mL(-1), ensuring the analysis of the drug in biological fluids. The procedure shows good accuracy, repeatability and selectivity. Repeatability and intermediate precision were tested for several concentrations of the drug. Good claim percentages were obtained in the analysis of pharmaceutical formulations. Calibration repeatability in urine matrix was also studied in the 0.06-22.4 microg mL(-1) range. Good recoveries were obtained from spiked urine samples. No interferences from common additives frequently administered with trazodone or from endogenous compounds in urine samples were found. The results show that the procedure is suitable for routine analysis of the drug.  相似文献   

11.
A reversed-phase liquid chromatographic procedure with a micellar mobile phase of sodium dodecyl sulfate (SDS), containing a small amount of pentanol, was developed for the control of 7 antihistamines of diverse action in pharmaceutical preparations (tablets, capsules, powders, solutions, and syrups): azatadine, carbinoxamine, cyclizine, cyproheptadine, diphenhydramine, doxylamine, and tripelennamine. The retention times of the drugs were <9 min with a mobile phase of 0.15M SDS-6% (v/v) pentanol. The recoveries with respect to the declared compositions were in the range of 93-110%, and the intra- and interday repeatabilities and interday reproducibility were <1.2%. The results were similar to those obtained with a conventional 60 + 40 (v/v) methanol-water mixture, with the advantage of reduced toxicity, flammability, environmental impact, and cost of the micellar-pentanol solutions. The lower risk of evaporation of the organic solvent dissolved in the micellar solutions also increased the stability of the mobile phase.  相似文献   

12.
A simple and sensitive method was optimized and validated for the analysis of carbadox and olaquindox residues in chicken muscles, chicken liver, bovine meat, liver and milk. Analytical separation was performed in less than 4 min using a C18 column with UV detection at 373 nm and a micellar solution of 0.1 M sodium dodecyl sulphate, 10 % acetonitrile and 0.3 % triethylamine in 0.02 M phosphoric acid buffered at pH 4 as the mobile phase. The method was fully validated in accordance with ICH guidelines. The micellar method was successfully applied to quantitatively determine carbadox and olaquindox residues in spiked chicken muscles, chicken liver, bovine meat, liver and milk. It was also extended to the determination of carbadox and olaquindox residues in baby formulae. The recoveries obtained were in the 89.2–93.6 and 93.0–107.2 % ranges for carbadox and olaquindox, respectively. High extraction efficiency for carbadox and olaquindox was obtained without matrix interference in the extraction process and in the subsequent chromatographic determination. No organic solvent was used during the pretreatment step.  相似文献   

13.
Quantitative high-performance liquid chromatographic (HPLC) and micellar electrokinetic chromatographic (MEKC) methods have been developed for the determination of four structurally related potential manufacturing impurities, including morphine, of the opiate derivative pholcodine. Pholcodine and the four impurities were separated by MEKC in less than 14 min using a 70 cm x 75 microm I.D. uncoated fused-silica capillary (25 kV at 30 degrees C) and a running buffer consisting of 10% acetonitrile (v/v) in 20 mM borate-phosphate buffer pH 8.0 containing 40 mM sodium dodecyl sulphate (SDS). The MEKC method was compared to a HPLC method using a 5 microm Luna phenyl-hexyl column (150 x 4.6 mm I.D.) eluted with a mobile phase consisting of a mixture of 10% (v/v) acetonitrile, 7% (v/v) tetrahydrofuran in 20 mM phosphate buffer pH 8.0. Both methods were fully validated and a comparison was made regarding selectivity, linearity, precision, robustness and limits of detection and quantitation. The presence of the impurities in different samples of pholcodine drug substance was investigated using both methods.  相似文献   

14.
A novel and unique approach was used for retention modelling in the separation of simvastatin and six impurities by liquid chromatographic using a microemulsion as mobile phase. A microemulsion is a modification of a micellar system where a lipophilic organic solvent is dissolved in the micelles; for that reason, microemulsions are usually treated as solvent-modified micellar solutions. When microemulsions are used as eluents in HPLC separations, solutes partition between the charged oil droplets and the aqueous buffer phase. The complexity of the composition of the microemulsion permits extensive manipulations to be made during method development in order to achieve acceptable resolution of such a complex mixture of substances. In order to avoid a laborious "trial and error" procedure, a 2(3) full factorial design was applied for choosing an optimal microemulsion composition to obtain good separation in a reasonable run time. Organic solvent, sodium dodecyl sulphate, and n-butanol content were varied within defined experimental domain. Optimal conditions for the separation of simvastatin and its six impurities were obtained using an X Terra 50 x 4.6 mm, 3.5 microm particle size column at 30 degrees C. The mobile phase consisted of 0.9% w/w of diisopropyl ether, 2.2% w/w of sodium dodecylsulphate (SDS), 7.0% w/w of co-surfactant such as n-butanol, and 89.9% w/w of aqueous 25 mM disodium phosphate pH 7.0.  相似文献   

15.
Presently, disulfiram is used in aversion therapy for recovering alcoholics. It acts by inhibiting aldehyde dehydrogenase, leading to high blood levels of acetaldehyde. A simple direct injection micellar liquid chromatographic procedure was developed to determine disulfiram in illicit preparations (ayurvedic, herbal, divine ash, and traditional medicine), as well as in pharmaceuticals and biological samples (urine). After application of a predictive optimization strategy, the proposed method was developed using a 0.1 M sodium dodecyl sulfate-butanol 4% (v/v) buffered to pH 7 as the mobile phase at a flow rate of 1 mL/min, an octyl silyl (C8) 150 mm column, and diode array detection at 248 nm. Under the above conditions, the analysis time was below 8 min. Validation studies were based on U.S. Food and Drug Administration guidelines. The LOD (3 x SD criterion) was 15 ng/mL and LOQ (10 x SD criterion) was 70 ng/mL for disulfiram. The intraday and interday precisions were below 3.5%, recoveries were in the range of 97-102%, and robustness was below 3%. The optimized and validated micellar liquid chromatographic method was successfully applied to the determination of disulfiram in ayurvedic, herbal, divine ash, and other samples. The procedure developed could also be used in the fields of QC, routine analysis, and pharmacokinetic studies.  相似文献   

16.
A sensitive, selective and efficient micellar liquid chromatographic (MLC) procedure was developed for the determination of furosemide (4-chloro-N-furfuryl-5-sulfamoylanthranilic acid) in urine samples by direct injection and UV detection. The procedure makes use of a C18 reversed-phase column and a micellar mobile phase of 0.05 mol l(-1) sodium dodecyl sulfate-6% v/v propanol and phosphate buffer at pH 3 to resolve furosemide from its photochemical degradation products. The importance of protecting the standards and urine samples to be analysed from light in the assay of furosemide, avoiding its degradation, was verified. The limit of quantification was 0.15 microg ml(-1) and the relative standard deviation of the inter-day assay was 0.8-0.04% in the 6-82 microg ml(-1) range. Detection of urinary excretion of furosemide was followed up to 12 h after ingestion of the drug by a healthy volunteer. No potential interference from the major metabolite (furosemide acylglucuronide) and its hydrolytic product (4-chloro-5-sulfamoylanthranilic acid) was observed. Commonly administered drugs also did not interfere. The proposed MLC procedure permits the rapid and reproducible measurement of low levels of furosemide in a small amount of urine.  相似文献   

17.
A new liquid chromatographic procedure for the determination of amobarbital and secobarbital in plasma samples is proposed. The method uses a Spherisorb octadecylsilane ODS-2 C(18) analytical column, a guard column of similar characteristics and 0.04 M CTAB solution buffered at pH 7.5 containing 3% 1-propanol as micellar mobile phase. The UV detection was carried out at 250 nm. Butabarbital was used as internal standard. Plasma samples preparation only required adequate dilution with the mobile phase before injection into the chromatographic system. The limits of detection were 0.2 and 0.4 mg/L for amobarbital and secobarbital, respectively. The proposed method allows the determination of amobarbital and secobarbital in plasma at therapeutic levels.  相似文献   

18.
《Analytical letters》2012,45(10):2011-2026
Abstract

In HPLC with a sodium dodecyl sulphate micellar mobile phase, a perturbation of the sodium ion equilibrium gives rise to a refractive index gradient associated to a concentration gradient. This produces a loss of sensitivity and an increase of noise at a reproducible value of the retention time when thermal lens spectrometric detection is used. Baseline perturbations as this one produced by retained components of the mobile phase can overlap with the peaks of the analytes.  相似文献   

19.
Rapid chromatographic procedure for quantification of five sulfonamides in medicated feeds are proposed. Satisfactory separation of sulfonamides from medicated feeds was achieved using a Zorbax Eclipse XDB C18 column (4.6 × 150 mm, 5 µm particle size) with a micellar mobile phase consisting of 0.05 M sodium dodecyl sulphate, 0.02 M phosphate buffer, and 6% propan-2-ol (pH 3). UV quantitation was set at 260 nm. The proposed procedure allows the determination of sulfaguanidine, sulfadiazine, sulfamerazine, sulfamethazine, and sulfamethoxazole in medicated feeds for pigs and poultry. Application of the proposed method to the analysis of five pharmaceuticals gave recoveries between 72.7% to 94.7% and coefficients of variations for repeatability and reproducibility between 2.9% to 9.8% respectively, in the range of 200 to 2000 mg/kg sulfonamides in feeds. Limit of detection and limit of quantification were 32.7–56.3 and 54.8–98.4 mg/kg, respectively, depending on the analyte. The proposed procedure for the quantification of sulfonamides is simple, rapid, sensitive, free from interferences and suitable for the routine control of feeds. In the world literature, we did not find the described method of quantitative determination of sulfonamides in medicated feeds with the use of micellar liquid chromatography.  相似文献   

20.
Melamine is a toxic triazine, illegally used as an additive in milk to apparently increase the amount of protein. A chromatographic procedure using a C18 column and a micellar mobile phase of sodium dodecyl sulphate (0.05 M) and propanol (7.5%), buffered at pH 3, and a detection set by absorbance at 210 nm, was reported for the resolution and quantification of melamine in liquid and powdered milk samples. In this work, samples were diluted with a SDS solution and were directly injected, thus avoiding long extraction and experimental procedures. Melamine was eluted in nearly 9.3 min without overlapping the protein band or other endogeneous compounds. The optimal mobile phase composition was taken using a chemometrical approach that considers the retention factor, efficiency and peak shape. Validation was performed following the European Commission's indications (European Decision 2002/657/EC), and the main analytical parameters studied were: linearity (0.02-100 ppm; r2 = 0.999), limit of detection (5 ppb), intra- and inter-day precision (R.S.D. <7.6% and <9.7%, respectively) and robustness (R.S.D. <7.4% for retention time and <5.0% for area). Sensitivity was adequate to detect melamine under the safety limits proposed by the US FDA. Finally, recoveries for several milk samples were found in the 85-109% range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号