首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Huang HY  Chiu CW  Chen YC  Yeh JM 《Electrophoresis》2005,26(4-5):895-902
Microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatograpy (MEKC) were compared for their abilities to separate and detect ten similar benzophenones, which are commonly used as UV filters in various plastic and cosmetic products. Sodium dodecyl sulfate (SDS) concentration and column temperature rarely affected separation resolution for MEEKC, but separation of benzophenones could be improved by changing the SDS concentration and column temperature for MEKC. Buffer pH and ethanol (organic modifier) were found to markedly influence the separation selectivity for both MEEKC and MEKC systems. In addition, a higher electric voltage improved the separation efficiency without a noticeable reduction in separation resolution for MEEKC, whereas it caused a poor separation resolution for the MEKC system.  相似文献   

2.
Huang HY  Lien WC 《Electrophoresis》2005,26(16):3134-3140
In this study, a microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect 13 phenolic compounds (syringic acid, p-cumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), which are present in many plant-derived foods. The effects of cosurfactant, organic modifier, and oil were examined in order to optimize the separation of these phenolic compounds. The amounts of cosurfactant (cyclohexanol) and organic modifier (acetonitrile) were determined as the major influence on the separation selectivity, while the type of oil partially affected the separation resolution of the phenolic compounds. A highly efficient MEEKC separation method was achieved within 14 min by using a microemulsion solution of pH 2.0 containing 2.89% w/v SDS, 1.36% w/v heptane, 7.66% w/v cyclohexanol, and 2% w/v ACN. Furthermore, the present work could demonstrate that the nature of the oil phase has a significant influence on the separation selectivity of phenolic compounds.  相似文献   

3.
Retention index (I), rather than retention factor (k), was found to be a more reasonable parameter for comparison of the relative affinity of disubstituted benzenes in MEEKC and MEKC, due to independent of I with the SDS surfactant concentration. MEKC and MEEKC may give similar or different I values, depending on types of moieties. With known I and Kow for alkylbenzenes as references in MEKC and MEEKC, the values of Kow for disubstituted benzenes can be estimated from the observed I values, where Kow is the octanol–water distribution constant. In addition, a group additive approach can be used to predict I for disubstituted benzenes with different moieties from the average observed I for the disubstituted benzenes with same moieties. However, electronic effects and/or intramolecular interaction may result in the different observed I from prediction.  相似文献   

4.
Melin V  Perrett D 《Electrophoresis》2004,25(10-11):1503-1510
Separations of human urine by microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic capillary chromatography (MEKC) with respect to resolution, migration times and efficiencies were optimized and compared. The optimised MEEKC and MEKC methods were simple and fast, both of which are excellent characteristics for the complex separations required in clinical and biomedical studies. However, resolution in MEKC was significantly greater than in MEEKC although migration times were 30% faster for the optimised MEEKC method. In addition, a faster analysis method (short-end injection) specifically for routine screening purposes was also investigated. With both MEEKC and MEKC modes, this provided short separations (less than 4 min for urine) with no major compromise in resolution. In conclusion, we found that MEEKC offered no real advantage over MEKC for urine analysis.  相似文献   

5.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

6.
Cao J  Chen J  Yi L  Li P  Qi LW 《Electrophoresis》2008,29(11):2310-2320
Oil-in-water (O/W) and water-in-oil (W/O) MEEKC were compared for their abilities to separate and detect eight phenolic acids and five diterpenoids in Radix et Rhizoma Salviae Miltiorrhizae (RRSM). The effects of oil type and concentration, organic modifier, SDS, and buffer concentration on separation were examined in order to optimize the two methods. Oil contents and organic modifier were found to markedly influence the separation selectivity for both O/W and W/O systems. SDS concentration rarely affected separation resolution for O/W MEEKC, and separation of eight phenolic acids and five diterpenoids could be improved by changing the buffer concentration for W/O MEEKC. A highly efficient O/W MEEKC separation method, where the 13 compounds were separated with baseline resolution, was achieved by using a microemulsion solution of pH 8.0 containing 0.6% cyclohexane, 3.0% SDS, 6.0% 1-butanol, and 3.0% ACN. The W/O MEEKC was unable to resolve all the components. In addition, the analytic time in O/W MEEKC was shorter than that in W/O MEEKC. Finally, the developed O/W MEEKC method was successfully applied to determine analytic compounds in RRSM samples.  相似文献   

7.
A group of phenolic compounds including phenolic aldehydes, acids and flavonoids are separated by micellar electrokinetic chromatography (MECC). The influence of buffer (concentration and pH), concentration of sodium dodecylsulphate (SDS) and applied voltage were studied. To increase the selectivity of the separation and the resolution of the solutes organic solvents are added to the separation buffer, the best results were obtained when methanol was used at lower percentages. An optimized buffer (150 mM boric acid (pH 8.5)-50 mM SDS-5% methanol) provides the optimum separation with regard to resolution and migration time. This method was applied to the determination of these compounds in wine samples with good results.  相似文献   

8.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

9.
Five electrokinetic chromatography systems were compared concerning retention behavior and lipophilicity. Comparison was based on capacity (retention) factors of some steroidal drugs, and on log P(OW) values derived by the aid of reference substances. In all systems the aqueous buffer consisted of phosphate (20 mM, pH 7.5). Two systems had micelles, three systems microdroplets as negatively charged pseudostationary phases. The micelles were formed by sodium dodecyl sulfate (SDS) and sodium cholate, respectively. One microemulsion consisted (as usual) from octane as oil, butanol as cosurfactant and SDS as charged tenside. Two microemulsions were made from biosurfactants (phosphatidylcholine, isopropylmyristate) to better simulate biopartitioning of the drugs. Even for noncharged analytes a change in migration sequence and thus in log P(OW) was observed for the systems consisting of the biosurfactants, compared to the others. For the former systems, log P(OW) derived from the capacity factors agree for all analytes with those obtained from calculation by computer software based on the structure of the drugs, and with experimental data directly obtained from octanol/water partitioning.  相似文献   

10.
Cis-diol-containing compounds (CDCCs) are usually highly hydrophilic compounds and are therefore difficult to separate by conventional reversed-phase-based micellar electrokinetic chromatography (MEKC) due to poor selectivity. Here, we report a new method, called boronate affinity-assisted micellar electrokinetic chromatography (BAA-MEKC), to solve this issue. A boronic acid with a hydrophobic alkyl chain was added to the background electrolyte, which acted as a modifier to adjust the selectivity. CDCCs can covalently react with the boronic acid to form negatively charged surfactant-like complexes, which can partition into micelles formed with a cationic surfactant. Thus, CDCCs can be separated according to the differential partition constants of their boronic acid complexes between the micellar phase and the surrounding aqueous phase. To verify this method, eight nucleosides were employed as the test compounds and their separation confirmed that the combination of boronate affinity interaction with MEKC can effectively enhance the separation of CDCCs. The effects of experimental conditions on the separation were investigated. Finally, the BAA-MEKC method was applied to the separation and analysis of nucleosides extracted from human urine. BAA-MEKC exhibited better selectivity and improved separation as compared with conventional MEKC and CZE. Successful quantitative analysis of urinary nucleosides by BAA-MEKC was demonstrated.  相似文献   

11.
Microemulsion electrokinetic chromatography (MEEKC) has been developed for fingerprint analysis of resina draconis, a substitute for sanguis draconis in the Chinese market. The microemulsion as the running buffer was made up of 3.3% (w/v) sodium dodecyl sulfate (SDS), 6.6% (w/v) n-butanol, 0.8% (w/v) n-octane, and 10 mmol/L sodium tetraborate buffer (pH 9.2), which was also used as the solvent for ultrasonic extraction of both water- and fat-soluble compounds in the traditional Chinese medicine samples. Four batches of resina draconis obtained from different pharmaceutical factories located in different geographic regions were used to establish the electrophoretic fingerprint. MEEKC was performed using a Beckman PACE/MDQ system equipped with a diode-array detector and with monitoring at 280 nm. The fingerprint of resina draconis comprised 27 common peaks within 100 min. The relative standard deviations of the relative migration time of these common peaks were less than 2.1%. Through repetitive injection of the sample solution six times in 24 h, all relative standard deviations of the migration time and peak area of loureirin A and loureirin B were less than 2.5 and 3.8%, which demonstrated that the method had good stability and reproducibility. The relative peak areas of these common peaks in the electropherograms of four batches of resina draconis were processed with two mathematical methods, the correlation coefficient and the interangle cosine, to valuate the similarity. The values of the similarity degree of all samples were more than 0.91, which showed resina draconis samples from different origins were consistent. On the other hand, high-performance liquid chromatography (HPLC) coupled with photodiode-array detection was also applied to establish the fingerprint of resina draconis. The samples were separated with a LiChrospher C18 column using acetonitrile (solvent A) and water containing 0.1% H3PO4 (solvent B) as the mobile phase in linear gradient elution mode at a flow rate of 0.6 mL/min and detection was at 280 nm. There were only 20 common peaks in the HPLC fingerprint, and the values of the similarity degree of all samples were also more than 0.91. Though the similarity results of fingerprint analysis seemed to be the same, MEEKC resulted in more common peaks and higher separation efficiency for a variety of polarities of the components than HPLC. So, MEEKC was more suitable for development of the fingerprint of resina draconis.  相似文献   

12.
New possibilities were revealed and evaluative characteristics were obtained for different versions of capillary electrophoresis with UV detection, namely, micellar electrokinetic chromatography with normal and reversed polarity and microemulsion electrokinetic chromatography, used for determining catechols and catecholamines in green and black tea and in urine.  相似文献   

13.
Mertzman MD  Foley JP 《Electrophoresis》2005,26(21):4153-4163
A direct comparison of dodecoxycarbonylvaline (DDCV) microemulsion, micellar and butanol-modified micellar aggregate systems was performed employing both 2 and 4% DDCV. With respect to either DDCV concentration, use of the micellar system provided the largest elution range, followed by the butanol-modified micellar system and ultimately the microemulsion. Using 2% DDCV, all three aggregate analyses yielded similar values for enantioselectivity, resolution and retention factors that were slightly better using the micellar phase, but efficiencies were consistently better using either the microemulsion or butanol-modified micellar phases. Largely, the microemulsion and butanol-modified micellar phases behaved fairly similar, although use of the butanol-modified micelle provided resolution and efficiency that were slightly better for all but two of the compounds. While reasonable separations were achieved using 2% DDCV, the results using 4% DDCV for the microemulsion system were far superior. Analyses using analogous micellar and butanol-modified micellar aggregates were unstable, making them unsuitable for use at that surfactant concentration.  相似文献   

14.
Micellar electrokinetic capillary chromatography (MECC) based on sodium cholate (NaCh) and sodium dodecyl sulphate (SDS) was developed for the determination of aromatic amino acids and heterocyclic legume constituents. The influence of temperature, voltage, micellar system, pH, zwitterion and modifier concentrations in the buffer on migration times, peak areas, resolution and number of theoretical plates was investigated. This MECC method makes possible the sensitive determination of the individual compounds with detection limits in the picomole range. Up to 300 000 theoretical plates per metre of capillary were obtained together with satisfactory linearity and repeatability of the NaCh method. The applicability of MECC to samples prepared from plant material, following a fast and simple technique of isolation, purification and group separation, is illustrated by selected examples.  相似文献   

15.
16.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

17.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

18.
This work examines the potential of microemulsion electrokinetic chromatography for the separation of several priority endocrine disrupting compounds (EDCs). The optimised microemulsion system comprised 25 mM phosphate buffer pH 2, 80 mM octane, 900 mM butanol, 200 mM sodium dodecyl sulphate and was further modified with 20% propanol. The use of a low pH buffer resulted in the suppression of electroosmotic flow within the capillary. Reversal of the conventional electrode polarity resulted in faster migration of hydrophobic compounds. Test analytes included the octylphenol, nonylphenol and nonylphenol diethoxylate, which are breakdown products of the alkylphenolic detergents. The synthetic oestrogens diethylstilbestrol and ethynyloestradiol were also included in the separation along with the plastic monomer bisphenol-A. Test analytes were selected due to their reported presence in environmental samples namely industrial and domestic wastewater treatment effluents and sludges. Using the optimised method a separation of six EDCs was achieved within 15 min. The optimised method was then applied to the analysis of a spiked wastewater influent sample with UV detection of all six compounds at 214 nm.  相似文献   

19.
The potential utility in pharmaceutical analysis of a capillary electrokinetic separation technique that employs a micellar "pseudo-stationary phase" is discussed and illustrated. Chromatograms of separations of vitamin metabolites and derivatized amino acids are presented to illustrate the high efficiency of the technique and the ability to simultaneously separate the charged and neutral components of pharmaceutical samples. The analytical characteristics of the technique and the importance of optimizing experimental parameters, such as surfactant concentration and capillary column diameter, are discussed and demonstrated with the aid of chromatograms.  相似文献   

20.
A chiral microemulsion electrokinetic chromatography method has been developed for the enantiomeric separation of 3,4-dihydroxyphenylalanine (dopa), its precursors phenylalanine and tyrosine, and the structurally related substance methyldopa. The separations were achieved using an oil-in-water microemulsion, which consisted of the oil-compound ethyl acetate, the surfactant sodium dodecylsulfate (SDS), the co-surfactant 1-butanol, the organic modifier propan-2-ol and 20mM phosphate buffer pH 2.5 or 2.0 as aqueous phase. For enantioseparation sulfated beta-cyclodextrin was added. The resolution of each racemate was optimized by varying the concentration of the buffer and all components of the microemulsion. Enantioseparation could be achieved for dl-dopa, dl-phenylalanine and dl-tyrosine within 13min with a resolution of 4.3, 3.1 and 3.3, respectively, and for methyldopa in 17min (Rs: 1.4). The established methods allowed the detection of dopa, phenylalanine, tyrosine and methyldopa with a limit at 0.5, 1.0, 0.2 and 2.0mug/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号