首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The elution mechanism of sodium sulfonates on both Deltabond cyanopropyl and bare silica stationary phases with an isocratic mobile phase composed of methanol-modified CO2 wherein an ammonium salt additive was dissolved in the methanol has been studied. The presence of the additive was crucial concerning elution of the sulfonate salts. Solid state 29silicon nuclear magnetic resonance spectroscopy provided some insight concerning the interaction of the mobile phase additive with the silica-based stationary phase. Computational calculations concerning the charge distribution on various ammonium salts were performed in an effort to explain the elution behavior. Ammonium ions are believed to deactivate available silanol sites on both phases. In addition, ammonium ion is speculated to interact with the cyano groups on the bonded phase. For concentrations of additive greater than 2 mM, stationary phase coverage of ammonium ion is anticipated to exceed one monolayer for both bare and bonded silica. The acetate counter-ion is thought to facilitate elution of the anionic sulfonates from the positively charged stationary phase in a pseudo ion exchange mechanism.  相似文献   

2.
The separation of four water soluble nucleobases (thymine, uracil, adenine, and cytosine) via supercritical fluid chromatography with a CO2‐based mobile phase containing an alcohol modifier and additive is described. Methanol, ethanol, 1‐propanol, and 1‐butanol were examined in conjunction with water as a neutral additive. Packed column stationary phases included silica bonded diol, cyanopropyl, and 2‐ethyl pyridine. Thymine and uracil eluted with good peak shapes without additive, while adenine and cytosine yielded late eluting, severely tailing peaks. The addition of up to 5% water to each of the five alcohols gave rise to much sharper peaks that eluted under gradient conditions in less than 10 min with no baseline noise. Results with water under identical chromatographic conditions were compared with formic acid and ammonium acetate as additives. Water proved to be much superior to formic acid, and it was comparable to ammonium acetate. The role of water was speculated to not only enhance the solvating power of the binary mobile phase for water soluble analytes, but the common elution pattern exhibited by each of the three stationary phases suggested that water had altered the surface chemistry of the packed phase.  相似文献   

3.
Addition of a small amount of polar solvent (i.e., modifier) to CO2 in packed column supercritical fluid chromatography (SFC) has shown major improvements in both polar analyte solubility and interaction of the polar analyte with the stationary phase. Recently, the addition of an ionic component (i.e., additive) to the primary modifier by one of us has been shown to extend even further the application of SFC to polar analytes. In this work, the effect of various ionic additives on the elution of ionic compounds, such as sodium 4-dodecylbenzene sulfonate and sodium 4-octylbenene sulfonate, has been studied. The additives were lithium acetate, ammonium acetate, tetramethylammonium acetate, tetrabutylammonium acetate, and ammonium chloride dissolved in methanol. Three stationary phases with different degrees of deactivation were considered: conventional cyanopropyl, deltabond cyanopropyl, and bare silica. The effect of additive concentration and additive functionality on analyte retention was investigated. Sodium 4-dodecylbenzene sulfonate was successfully eluted using all the additives with good peak shape under isocratic/isobaric/isothermal conditions. Different additives, however, yielded different retention times and in some cases different peak shapes.  相似文献   

4.
Aqueous solutions of bile salts, i.e. sodium cholate (NaC), sodium deoxycholate (NaDC), and sodium taurocholate (NaTC), are characterized and evaluated as reversed-phase liquid chromatographic (RPLC) mobile phases. The separation of the ASTM-recommended RPLC test mix in addition to more than 50 other compounds on a C18 column demonstrates the viability of these bile salts as HPLC mobile phases. The Armstrong-Nome theory was applied and found to adequately describe the partitioning behavior of solutes eluted with these bile salts at low surfactant concentrations. The effect of alcohol additives on chromatographic retention and efficiency was also assessed. Not only are the bile salt molecules rigid and chiral, but they form helical micellar aggregates as well. Consequently, many isomeric compounds can be easily resolved with this mobile phase additive. The base-line resolution of some binaphthyl-type enantiomers with a standard C18 column and the bile salt micellar mobile phases is also demonstrated. In addition, these bile salt mobile phases may be preferable to conventional hydroorganic mobile phase systems for the separation of many classes of routine compounds. A brief prospectus on the future utilization of bile salts in liquid chromatography is presented.  相似文献   

5.
A new stationary phase which contains both negatively charged phosphate groups and positively charged amino groups was successfully synthesized by modification of amino-functionalized silica particles with trichlorophosphine oxide (POCl3) for hydrophilic interaction chromatography (HILIC). The composition of the surface grafts was determined by Fourier transform infrared spectroscopy and elemental analysis. Various parameters, such as column temperature, water content, pH values and ionic strength of the mobile phase were investigated to study the retention mechanism. The results demonstrated that the stationary phase involved a complex retention process including surface adsorption, partitioning and electrostatic interactions. Under optimized conditions, the separation of nucleobases and nucleosides, water-soluble vitamins, organic acids on the novel stationary phase could be achieved in the HILIC mode.  相似文献   

6.
We investigated the effects of the concentration of naphthalene sulphonic acids (NSAs) as anionic test compounds in the injected sample and of the salt additives to the mobile phase on ion-exclusion. The retention behaviour of NSAs sensitively reflects even minor changes in the ionic and hydrophobic interactions and can be useful for predicting the effects of the stationary phases in reversed-phase chromatography of polar and ionic compounds, both small ones and biopolymers, e.g., oligonucleotides. We studied chromatographic properties of several stationary phases intended for separations in aqueous mobile phases: a C18 column end-capped with polar hydrophilic groups, a densely bonded C8 column doubly end-capped with short alkyl groups, a short alkyl stationary phase designed to keep full pore accessibility in highly-aqueous mobile phases and a Bidentate column with “bridged” C18 groups attached to the silica hydride support. The chemistry and pore structure of various types of column packing materials and of the salt additives to the mobile phase affect the proportion of the pore volume non-accessible to anions due to ion-exclusion and consequently the peak asymmetry and hydrophobic selectivity in reversed-phase chromatography of organic acids. We also addressed the problems connected with the determination of column hold-up volume in aqueous mobile phases. The accessibility of the stationary phase for anionic compounds in contact with the sample zone is affected by ion-exclusion due to repulsive interactions with the negatively charged surface in the pores of the stationary phase. The accessible part of the stationary phase increases and consequently the migration velocity along the column decreases with increasing concentration of the sample in the zone moving along the column. Because of a limited access to the stationary phase, its capacity can be easily overloaded. The combination of the column overload and ion-exclusion effects may result in fronting or tailing peak asymmetry. To explain this behaviour, we proposed a modified Langmuir model, respecting the variation of the column capacity due to the effects of sample concentration on ion-exclusion.  相似文献   

7.
An efficient two‐step method has been developed for the separation of β‐cypermethrin stereoisomers by supercritical fluid chromatography with polysaccharide chiral stationary phases. With respect to retention, selectivity, and resolution of β‐cypermethrin, the effects of chiral stationary phases, cosolvents, mobile phases, and column temperature have been studied in detail. Through a two‐step separation, β‐cypermethrin was firstly separated by using a cellulose‐derived chiral stationary phase to obtain two stereoisomeric pairs, and further resolved on an amylose‐based chiral stationary phase to produce four enantiopure stereoisomers. The electronic circular dichroism patterns of the first‐ and the third‐eluted isomers in methanol solution showed the mirror image of each other in the wavelength range 200∼300 nm, indicating that they were a pair of enantiomers. Moreover, the second‐ and the fourth‐eluted isomers were also enantiomers. This proposed two‐step strategy showed low solvent consumption, fast separation speed, and high‐purity, which may provide an effective approach for preparative separation of compounds with multiple chiral centers and difficult‐to‐separate multicomponent samples.  相似文献   

8.
Cheng  Xiao-Dong  Peng  Xi-Tian  Yu  Qiong-Wei  Yuan  Bi-Feng  Feng  Yu-Qi 《Chromatographia》2013,76(23):1569-1576

A new stationary phase which contains both negatively charged phosphate groups and positively charged amino groups was successfully synthesized by modification of amino-functionalized silica particles with trichlorophosphine oxide (POCl3) for hydrophilic interaction chromatography (HILIC). The composition of the surface grafts was determined by Fourier transform infrared spectroscopy and elemental analysis. Various parameters, such as column temperature, water content, pH values and ionic strength of the mobile phase were investigated to study the retention mechanism. The results demonstrated that the stationary phase involved a complex retention process including surface adsorption, partitioning and electrostatic interactions. Under optimized conditions, the separation of nucleobases and nucleosides, water-soluble vitamins, organic acids on the novel stationary phase could be achieved in the HILIC mode.

  相似文献   

9.
Phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylinositol (PI), and phosphatidylserine (PS) have been separated by supercritical fluid chromatography coupled with evaporative light scattering and mass spectrometric detection. Four different silica based stationary phases were investigated: diol, cyanopropyl, 2-ethylpyridine, and 4-ethylpyridine. A gradient mobile phase of pressurized carbon dioxide modified with methanol was employed. The individual effect of basic (isopropylamine), acidic (trifluoroacetic acid), and ionic (ammonium acetate) additives incorporated into the primary modifier on the separation of these four lipids from the four stationary phases was investigated. No additive was required to effect the elution of PC and PE (which differed only in polar head group) from any of the four phases. When the two ethylpyridine phases were used, near baseline resolution of two species in each lipid case that differed in fatty acid content were seen. PS and PI could be successfully eluted from each phase when isopropylamine was added to the mobile phase, although the PS peak was always weak and very broad. Ammonium acetate was a more effective additive for phospholipid separation than trifluoroacetic acid. All chromatographic separations were reproducible and required less than 15 min.  相似文献   

10.
Reversed phase liquid chromatography of alkyl-imidazolium ionic liquids   总被引:2,自引:0,他引:2  
Eleven 1-alkyl-3-methyl imidazolium ionic liquid (IL) salts were analyzed in reversed phase mode with a Kromasil C18 column. The mobile phases were water-rich acetonitrile solutions (water content > or =70%, v/v) without any added salts. It is shown that it is possible to separate different ILs sharing the same cation and differing by the anion when salt-free mobile phases are used. When a buffer, acetate or phosphate salt, or any salt, such as sodium chloride or sodium tetrafluorobarate, is added to the mobile phase, the ILs differing only by their anions cannot be separated. ILs with different alkyl chains in the imidazolium cation are separated by mobile phases with or without added salts following a hydrophobic interaction behavior: log k is proportional to nC, the carbon number of the alkyl chain. Important differences in ion/stationary phase interactions are observed depending on the ionic content of the mobile phase. With salt-free mobile phases, the IL/C18 stationary phase interactions correspond to concave isotherms associated with fronting peaks for all ILs. With mobile phase containing 0.01 M of salt, tailing IL peaks correspond to convex adsorption isotherms. Also, the IL retention factor depends on the concentration and nature of the added salt. Hexafluorophosphate chaotropic anions can adsorb on the Kromasil C18 surface dramatically increasing the imidazolium cation retention factors.  相似文献   

11.
New zwitterionic stationary phases were synthesized by covalently bonding 3-P,P-diphenylphosphonium-propylsulfonate to silica gel. The resulting materials possess both a negatively charged sulfonate group and a positively charged quaternary phosphonium group, which means that there is no net charge over a wide pH range. The retention mechanism and chromatographic behavior of polar solutes under HILIC conditions were studied on these zwitterionic phases. Compared to the commercial ZIC-HILIC column and a bare silica gel stationary phase, the newly synthesized zwitterionic stationary phases provided greater retention, higher peak efficiency and better peak symmetry in the HILIC mode. The analytes examined included: β-blockers, nucleic acid bases and nucleosides, salicylic acid and its analogues, and water soluble vitamins. Factors, such as the type of organic modifiers, solvent composition, pH and the buffer concentration of the mobile phase, have been considered as potential variables for controlling the chromatographic retention of polar analytes.  相似文献   

12.
Packed-column supercritical fluid chromatography has been used for the separation of mixtures of sulphonamides on silica and amino-bonded stationary phases utilizing carbon dioxide with methanol modifier as the mobile phase. The effect of modifier concentration, column pressure and modifier identity on retention was also studied. Packed-column supercritical fluid chromatography-mass spectrometry (SFC-MS) of these mixtures utilizing both moving-belt and modified thermospray interfaces was also studied. The identification of sulphamethazine in a spiked porcine kidney extract was performed by SFC-MS using the moving-belt interface.  相似文献   

13.
Abstract

Alkylsulfonate (RSO3 ?) salts were evaluated as mobile phase additives for the separation of free amino acids on reverse stationary phases using an acidic mobile phase where the amino acids are cations. The enhanced amino acid retention is the result of two major interactions, one being retention of the RSO3 ? salt on the stationary phase and the other an ion exchange selectivity between the amino acid analyte cation and the RSO3 ? countercation, or other countercations in the mobile phase. Major mobile phase variables are: type and concentration of RSO3 ? salt (the studies focused on C8SO3 ? salts), presence of organic modifier, type of countercation present, and mobile phase pH and ionic strength. Alkyl modified silica and polystyrenedivinyl-benzene copolymeric reverse stationary phases were compared. A mobile phase gradient, increasing per cent organic modifier was shown to be best, is necessary for separating complex mixtures of polar and nonpolar or basic amino acids. The procedure is applicable to the identification and/or determination of amino acids in mixtures or in peptides after hydrolysis.  相似文献   

14.
Retention and separation of achiral compounds in supercritical fluid chromatography (SFC) depend on numerous parameters: some of these parameters are identical to those encountered in HPLC, such as the mobile phase polarity, while others are specific to SFC, as the density changes of the fluid, due to temperature and/or pressure variations. Additional effects are also related to the fluid compressibility, leading to unusual retention changes in SFC, for instance when flow rate or column length is varied. These additional effects can be minimised by working at lower temperatures in the subcritical domain, simplifying the understanding of retention behaviours. In these subcritical conditions, varied modifiers can be mixed to carbon dioxide, from hexane to methanol, allowing tuning the mobile phase polarity. With nonpolar modifiers, polar stationary phases are classically used. These chromatographic conditions are close to the ones of normal-phase LC. The addition of polar modifiers such as methanol or ACN increases the mobile phase polarity, allowing working with less polar stationary phases. In this case, despite the absence of water, retention behaviours generally follow the rules of RP LC. Moreover, because identical mobile phases can be used with all stationary phase types, from polar silica to nonpolar C18-bonded silica, the classical domains, RP and normal-phase, are easily brought together in SFC. A unified classification method based on the solvation parameter model is proposed to compare the stationary phase properties used with the same subcritical mobile phase.  相似文献   

15.
The characterization and determination of peptides is of great importance in the pharmaceutical industry as is the ability to rapidly perform targeted determinations of bioactive peptides in complex matrices. The purpose of the presented work is to assess the feasibility of packed column supercritical fluid chromatography (SFC) for the separation of two-pairs of water soluble peptides of identical mass, composition and charge that differ only in amino acid sequence. Upon evaluating a variety of conditions, trifluoroacetic acid (HTFA) in conjunction with methanol as the modifier proved to be, in general, the most successful mobile phase additive for elution of the two isomeric peptide pairs from all nitrogenous stationary phases. In contrast, water and ammonium acetate gave distorted peak shapes and therefore proved to be less satisfactory as neutral additives. The basic additive, iso-propylamine (IPAm), coupled with HA-Pyridine yielded the highest resolution factor for the complete study. Aminopropyl and HA-Pyridine columns with 5 μm particle size and 60 Å pore size were found to be best for resolution of each peptide pair. Bare silica and phenyl-hexyl stationary phases did not afford any separation. The primary roles of the carbon dioxide and methanol modifier are believed to provide (a) stationary phase solvation and (b) peptide solubility and transport; while, HTFA is postulated to fully protonate each peptide and form ion pairs between its conjugate base and cationic peptide analyte. The separation process, therefore, is best viewed as ion pair supercritical fluid chromatography (IP-SFC). For the case where IPAm gave good resolution on the HA-Pyridine column, the peptides are probably in the neutral state.  相似文献   

16.
Monolithic columns have been prepared with a novel bonded silica stationary phase, tetradecylamine bonded silica (TDAS), and used in pressurized capillary electrochromatography (pCEC). The monolithic silica column matrix was prepared by a sol-gel process and then chemically modified with the spacer (3-glycidoxypropyl)trimethoxysilane and tetradecylamine. The introduced embedded polar amine groups dominated the charge on the surface of the monolithic stationary phase and generated an EOF from cathode to anode under acidic conditions. The tetradecyl hydrophobic chains in TDAS provide chromatographic interactions. The chromatographic characteristics of the prepared monolithic column were studied. Some aromatic compounds including alkylbenzenes, aromatic hydrocarbons, phenols, and anilines were successfully separated on the TDAS monolithic column in pCEC mode. As expected, the TDAS monolithic stationary phases exhibit typical reversed-phase electrochromatographic behavior toward neutral solutes due to the introduced tetradecyl groups. Hydrophobic as well as electrophoretic migration processes within the monoliths were observed in the separation of basic anilines. Symmetrical peaks can be obtained for anilines because the embedded polar amine groups on the surface can effectively shield the adsorption of positively charged analytes onto the stationary phase.  相似文献   

17.
In this study, a method for enantioseparation of terbutaline and salbutamol was established using Chirobiotic V column as a stationary phase. Polar ionic mode applying mobile phase containing ammonium nitrate in 100% ethanol, pH 5.1 was found to give the best separation. The salt concentration in the mobile phase and pH value were found to be the most important chromatographic factors affecting separation. Separation of enantiomers of these two basic analytes was complete in less than 10 min without applying ammonium trifluoroacetate (ATFA) or triethylamine (TEA) salts.  相似文献   

18.
Several mobile phase additives (i.e., organic acids and their ammonium salts) were used to modulate the chromatographic retention of cyanocobalamin and its cis‐diaminemonochloroplatinum(II) conjugate, depending on the specific nature of the stationary phase. Regardless of the mobile phase additive, the positively charged cyanocobalamin‐cis‐diaminemonochloroplatinum(II) conjugate was systematically less retained than cyanocobalamin on a conventional octadecyl‐silica column. In contrast, the amide‐embedded C18 column exhibited a progressive increase in the conjugate retention time upon changing the mobile phase additive from organic (acetic, formic and trifluoroacetic) acids to ammonium salts, ultimately leading to an inversion of the elution order. This change of retention was interpreted by invoking the interplay between hydrophobic interactions, hydrogen bonding between the conjugate and the polar amide groups and the ion‐pairing ability of the lyophilic counterions, whereby the acetate anion was found to be the most suitable to control the solute retention.  相似文献   

19.
The use of a high content of acetic acid as mobile phase additive for the reversed-phase high-performance liquid chromatography (RP-HPLC) of several proteins and extracts of biological tissues was evaluated for a divinylbenzene (DVB)-based stationary phase, and the separations obtained with acetic acid gradients in acetonitrile, isopropanol or water were compared with classical polypeptide RP-HPLC on silica C4 with trifluoroacetic acid (TFA)-acetonitrile. The separation patterns for recombinant derived interleukin-1 beta (IL-1 beta) on the C4 column eluted with TFA-acetonitrile and the DVB column eluted with acetic acid-acetonitrile were similar, but only the polymeric column was able to separate the components present in an iodinated IL-1 beta preparation. Neither eluent had any harmful effect on the biological activity of IL-1 beta isolated after RP-HPLC. Several standard proteins could be separated when the polymeric column was eluted with acetic acid gradients in acetonitrile, isopropanol or water and, although the separation efficiency with acetic acid in water was lower than that in combination with classical organic modifiers, insulin, glucagon and human growth hormone (hGH) were eluted as sharp, symmetrical peaks. The recoveries of insulin and hGH were comparable for all three mobile phases (80-90%). The separation patterns obtained from a crude acetic acid extract of a normal and a diabetic, human pancreas analysed using acetic acid gradients with or without organic modifiers were found to be similar and comparable to those obtained on a silica C4 column eluted with an acetonitrile gradient in TFA. The principal differences resulted from the use of different UV wavelengths (215 nm for TFA-acetonitrile, 280 nm for acetic acid). Acetic acid extracts of recombinant derived hGH-producing Escherichia coli were separated on the DVB column eluted with an acetic acid gradient in water. Although the starting material was a highly complex mixture, the hGH isolated after this single-step purification was surprisingly pure (as judged by sodium dodecyl sulphate-polyacrylamide gel electrophoresis). Consequently several (pure) polypeptides and complex biological samples were separated on a polymeric stationary phase eluted with acetic acid gradients in water without the use of organic modifiers.  相似文献   

20.
Summary The retention behavior of a set of polycyclic aromatic hydrocarbons in supercritical fluid chromatography have been studied on a chemically bonded stationary phase based upon a side chain liquid crystalline polymer (LCP) with carbon dioxide-based mobile phase. The effects of the mobile phase pressure, column temperature and amount of mobile phase organic modifier have been investigated in order to detect a possible structural change in the liquid crystal polymer linked to the silica support. The influence of these factors on the selectivity coefficients has also been studied. Two distinctive behaviors with temperature are noted at low pressure on the one hand and at higher pressure on the other. This change in behavior is based on the density of the supercritical CO2 and the PAH volatility rather than on any specific stationary phase structural change. Both lower mobile phase pressure and amount of mobile phase modifier are required to obtain better selectivities. Better planarity recognition is observed in SFC than in HPLC with these new bonded liquid crystal stationary phases. The bonded liquid crystal phase is only weakly affected by the addition of organic modifier in the supercritical CO2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号