首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Summary A simple and rapid capillary zone electrophoretic method with UV detection has been developed for determination of tosufloxacin and trovafloxacin. The separation was performed in fused-silica capillaries (57 cm length × 75μm i.d.); the running buffer was 35mm borate + 35mm phosphate buffer solution, pH 8.6, containing 6% (v/v) acetonitrile. The applied potential was 15 kV, the temperature 30°C, and detection was at 262 nm. Piromidic acid was used as the internal standard. Response was linearly dependent on concentration in the range 1.0–120.0 μg mL−1 and the detection limit was 0.2 μg mL−1 for both compounds. The analysis was highly reproducible (RSD between 3.41 and 1.25%). The method was applied to the determination of tosufloxacin and trovafloxacin in human and rat urine. The method was validated by using HPLC as a reference method. Recovery was between 96.8 and 102%.  相似文献   

2.
Determination of bromide and iodide in real samples (water, pharmaceutical preparations, and biological material) was performed using modified flow injection analyses (FIA) with amperometric detection on platinum electrode. As an additional confirmation of FIA experiments, cyclic voltammetry was employed. Iodide was determined by the kinetic method, its limit of detection was 1.0 nM, and the linearity was 0.1–100 μM. The limit of detection for bromide determination was 50.0 nM and the calibration was linear for 2.5–100 μM and 0.1–10 mM. The relative standard deviation for 1 μM of iodide was 3.03% and, for 5 μM of bromide, it was 1.23% (n = 6). Both methods enable 60 analyses per hour to be performed. The text was submitted by the authors in English.  相似文献   

3.
A robust flow injection (FI) on-line liquid-liquid extraction (LLE) preconcentration/separation system associated with a newly designed gravitational phase separator, coupled to flame atomic absorption spectrometry (FAAS) was developed. The performance of the system was illustrated for cadmium determination at the μg l−1 level. The non-charged cadmium complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into isobutyl methyl ketone (IBMK). The organic phase was effectively separated from a large volume of aqueous phase and is led into a 100 μl loop of an injection valve before its introduction into the nebulizer. The system was optimized and offered good performance characteristics with unlimited life time of phase separator, greater flow rate ratios and improved flexibility, as compared with other solvent extraction preconcentration systems. With a sampling frequency of 33 h−1, the enhancement factor was 155, the detection limit was 0.02 μg l−1, the relative standard deviation was 3.2% at 2.0 μg l−1 Cd concentration level and the calibration curve was linear over the concentration range 0.06-6.0 μg l−1. The accuracy of the proposed method was evaluated by analyzing a certified reference material of water and by recovery measurements on spiked samples. Finally, it was successfully applied to the analysis of tapwater, river and seawater samples.  相似文献   

4.
Chao Lu  Jinge Li  Jin-Ming Lin 《Talanta》2010,82(4):1576-9063
Peroxymonocarbonate (HCO4) was produced by the online reaction of bicarbonate with hydrogen peroxide. A strong chemiluminescence (CL) was observed when HCO4 reacted with AuCl4 without any special CL reagent. When bisphenol A (BPA) was added to AuCl4-HCO4 CL system, the CL emission was inhibited significantly. This new CL system was developed as a flow-injection method for the determination of BPA. Under the optimum experimental conditions, the inhibited CL intensity was linearly related to the concentration of BPA from 0.3 to 80 μM (R = 0.9958). The detection limit of BPA was 0.08 μM. The relative standard deviation for 12 repeated measurements of 1.0 μM BPA was 2.9%. The interferences of some cationic ions can be removed by an online cation-exchange column. The applicability of the present CL system was demonstrated for the sensitive and selective determination of BPA in real samples (mineral water bottle, baby bottle, beverage bottle and polycarbonate container). Based on the CL spectrum, UV-visible adsorption spectra, and the quenching effect of reactive oxygen species scavengers, a possible CL mechanism was proposed.  相似文献   

5.
Summary This study deals with the development of a new HPLC method for the determination of 3-methoxy-4-hydroxyphenylglycol (MHPG), the main noradrenaline metabolite in human plasma. A Varian reversed-phase column (C8; 250 mm×4.6 mm i.d.; 5 μm particles) was used as the stationary phase and an aqueous solution of citric acid, 1-octanesulfonic acid, EDTA, and methanol was used as the mobile phase. Coulometric electrochemical detection (ED) was used to obtain the highest sensitivity. Isolation of MHPG from plasma was accomplished by means of a new solid-phase extraction procedure after a protein precipitation step. The extraction yield of MHPG from plasma was very high (>97%). Linearity was observed in the 0.5–25 ng mL−1 concentration range; the limit of detection was 0.2 ng mL−1 and the limit of quantitation was 0.5 ng mL−1. Repeatability (RSD,%) for plasma samples was found to be <3.2% and intermediate precision was <4.3%. The method was applied to the determination of MHPG in the plasma of healthy subjects under experimentally-induced psychological stress.  相似文献   

6.
齐崴  贾辰熙  何志敏  乔斌 《化学学报》2007,65(3):233-238
对具有抗癌活性的海洋环肽Axinastatin 1进行化学合成. 采用多级质谱法对合成环肽进行序列测定. 线性前体测序依据bx-yz断裂路径, 在同一张MS2谱中利用b和y离子所提供序列信息的互补来实现. 环肽测序依据bx→bx-1断裂路径, 每一级MS由b离子的C端碰撞掉一个氨基酸残基直到MS6, 得到2套b离子, 根据它们所提供序列信息的互补可准确测定环肽序列并推断其环结构, 同时观察到b离子重排现象. 讨论了上述断裂与重排的路径和机理, 并利用半经验量子化学PM3和AM1两种算法计算了碎片的生成焓, 验证了路径的合理性. 由离子b5PN的生成焓偏高和其重排间的联系尝试提出过渡结构假设.  相似文献   

7.
The possibility of preconcentrating vanadium, chromium, copper, and nickel by the simultaneous adsorption in a flow-through mode on a two-layer adsorbent and the determination of metal ions by diffuse reflectance spectroscopy was studied. The adsorbent was made of a polyacrylonitrile fiber, one layer of which was filled with an AV-17 anion exchanger (PANV-AV-17), while another layer, with a KU-2 cation exchanger (PANV-KU-2). The procedure was based on the simultaneous preconcentration of vanadium and chromium on the first disk and nickel and copper on the second disk, by pumping the analyzed solution through both disks in a flow-through cell. Then, vanadium was determined on the disk of PANV-AV-17 with 8-hydroxyquinoline-5-sulfonic acid in 0.1 M HCl; next, chromium was determined with 1,5-diphenylcarbazide; the complex of vanadium was decomposed by 0.5 M H2SO4 and ascorbic acid. In the PANV-KU-2 disk, nickel was determined with dimethylglyoxime and then copper was analyzed with sodium diethyldithiocarbamate; the complex of nickel was decomposed with 1 M HCl. The selectivity factors were determined. A procedure was developed for the dynamic adsorption-spectroscopic determination of the following elements present simultaneously (μg/mL): V, 0.01–0.05; Cr, 0.002–0.015; Ni, 0.02–0.10; and Cu, 0.02–0.15. The results of analysis of model solutions are presented for different component ratios, RSD < 20%.  相似文献   

8.
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL?1. The limit of detection was found to be 0.06 μg mL?1 and the quantification limit was 0.21 μg mL?1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.  相似文献   

9.
A marine bacterium was isolated from seawater near the Korean south coast for efficient saccharification from alginate. Based on 16S rDNA sequence, the isolated strain was identified as Pseudoalteromonas agarovorans. Various environmental factors affecting saccharification of alginate using P. agarovorans CHO-12 have been investigated in flask cultures. The optimum concentration of sugar was obtained at 30 rpm and 29 °C. Among various NaCl concentrations, when NaCl concentration was increased from 10 to 30 g/l, the cell concentration sharply increased, while there is no increase at above 40 g/l. The maximum sugar concentration was obtained at 13.8 when 30 g/l of NaCl was used. Yeast extract and corn steep liquor were the best nitrogen source for efficient saccharification. Especially, the sugar concentration of 14.9 g/l was obtained after 3 days of culture using a mixture of 1.0 g/l of yeast extract and 1.5 g/l of corn steep liquor. Scale up was carried out at 50 l of reactor for 3 days using P. agarovorans CHO-12 and Stenotrophomonas maltophilia sp. When S. maltophilia was used, cell concentration was about twofold higher than that of P. agarovorans CHO-12. On the other hand, when P. agarovorans CHO-12 was used, the maximum saccharification rate was obtained, 7.5 g/l/day after 2 days of culture, which was about tenfold higher than that of S. maltophilia.  相似文献   

10.
Enantioseparation of 1,1′-bi-2-naphthol (BINOL) was performed on a polysaccharide-based chiral stationary phase, Chiralcel OD-H, under normal-phase mode. The effects of polar modifier in the mobile phase on the retention, enantioseparation and elution order were investigated in detail. Solvent-induced reversal of elution order for BINOL was observed. When linear alcohols were adopted, R-BINOL was always eluted first. S-BINOL was eluted first when 2-propanol was used as a polar modifier. Enantioseparation could not be obtained when sec-butyl alcohol or tert-butyl alcohol was used as a polar modifier. When isoamyl alcohol or cyclohexanol was used as a polar modifier, favorable enantioseparation was obtained as with 1-pentanol or 1-hexanol; also, R-BINOL was the first-eluted enantiomer. It is worth emphasizing that significantly better enantioseparation was obtained when higher alcohols were used as polar modifier of the mobile phase. A nonlinear characteristic for the ln α against 1/T plots was universally observed in this study though the ln k against 1/T plots exhibited a linear feature. Associated with the obtained thermodynamic parameters, some interesting inferences about chiral recognition mechanism were proposed.  相似文献   

11.
A simple and rapid capillary electrophoresis with diode array detection method was developed for sepia ink identification in ancient graphic documents.Separation was performed in a fused-silica capillary (64.5 cm length, 50 μm i.d.). The running buffer was 20 mM sodium tetraborate solution, pH 9.2. The applied potential was 25 kV, temperature 25 °C and detection was at 220 nm. An appropriate extraction procedure was applied for the take and treatment of sample from the reference substances and ancient graphic documents. This method was successfully applied to the collection of drawings and maps from the Royal Chancellery Archives of Granada (Spain).  相似文献   

12.
Lanreotide, a somatostatin analogue, was radioiodinated with 125I to explore the possibility of using 123I labeled lanreotide as a diagnostic radiopharmaceutical for tumors overexpressing somatostatin (SST) receptors. Radioiodination was carried out with 125I using chloramine T as the oxidant. The labeling yield was >90%. Characterization of 125I-Lanreotide was carried out by paper electrophoresis as well as HPLC. 125I-Lanreotide was purified by chromatography using a C18 Sep-Pak column. Radiochemical purity of the purified 125I-Lanreotide thus obtained was >99%. Significant tumor uptake of 125I-Lanreotide was observed in C57BL/6 mice bearing melanoma.  相似文献   

13.

A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (LC) method for analysis for dutasteride has been successfully developed. Chromatography was performed on a 150 mm × 4.6 mm C18 column with acetonitrile–water 60:40 (v/v) as isocratic mobile phase at 1.0 mL min−1. Ultraviolet detection of dutasteride was at 210 nm. Its retention time was approximately 10 min and its peak was symmetrical. Response was a linear function of concentration over the range 0.2–1 μg mL−1 (R 2 = 0.997) and the limits of detection and quantitation were was 0.05 and 0.10 μg mL−1, respectively. The method was validated for linearity, precision, repeatability, sensitivity, and selectivity. Selectivity was validated by subjecting dutasteride stock solution to photolytic, acidic, basic, oxidative, and thermal degradation. The peaks from the degradation products did not interfere with that from dutasteride. The method was used to quantify dutasteride in pharmaceutical preparations.

  相似文献   

14.
The present study reports the development and validation of a high-throughput high-performance liquid chromatographic (HPLC) assay for the determination of caffeine in food samples. The analyte was separated rapidly from sample matrix using a short monolithic column (50 mm × 4.6 mm i.d.). The flow rate was 3.0 mL min−1, while the mobile phase consisted of ACN/water (10:90, v/v). Caffeine was detected directly at 274 nm. Under the optimal HPLC conditions, the sampling rate was 60 h−1. The assay was validated for linearity, LOD and LOQ, precision, selectivity and ruggedness. The case of external calibration versus standard addition for the analysis of real samples was also examined. The proposed assay was applied to the analysis of beverages and coffee samples.  相似文献   

15.
Solidified floating organic drop microextraction (SFODME) was successfully used as a sample preparation method for graphite furnace atomic absorption spectrometry (GFAAS). 20 μL of 1-undecanol containing dithizone as the chelating agent (2 × 10−4 mol L−1) was transferred to the water samples containing lead ions, and the solution was stirred for the prescribed time. The sample vial was cooled in an ice bath for 5 min. The solidified extract was transferred into a conical vial where it melted immediately, and then 10 μL of it was analyzed by GFAAS.Factors that influence the extraction and complex formation, such as pH, concentration of dithizone, extraction time, sample volume, and ionic strength were optimized. Under the optimized conditions, a good relative standard deviation of ±5.4% at 10 ng L−1 and detection limit of 0.9 ng L−1 were obtained. The procedure was applied to tap water, well water, river water and sea water, and accuracy was assessed through the analysis of certified reference water or recovery experiments.  相似文献   

16.
A polyclonal antibody against trinitrophenyl (TNP) derivatives was raised in rabbit, and the antibody was applied to detection of trinitrotoluene (TNT) using a surface plasmon resonance (SPR) biosensor. TNP-keyhole limpet hemocyanine (TNP-KLH) conjugate was injected into a rabbit, and a polyclonal anti-TNP antibody was realized after purification of the sera using protein G. Aspects of the anti-TNP antibody against various nitroaromatic compounds, such as cross-reactivities and affinities, were characterized. The temperature dependence of the affinity between the anti-TNP antibody and TNT was also evaluated. The quantification of TNT was based on the principle of indirect competitive immunoassay, in which the immunoreaction between the TNP-β-alanine-ovalbumin (TNP-β-ala-OVA) and anti-TNP antibody was inhibited in the presence of free TNT in solution. TNP-β-ala-OVA was immobilized to the dextran matrix on the Au surface by amine coupling. The addition of a mixture of free TNT to the anti-TNP antibody was found to decrease the incidence angle shift due to the inhibitory effect of TNT. The immunoassay exhibited excellent sensitivity for the detection of TNT in the concentration range of 3 × 10−11 to 3 × 10−7 g/ml. To increase the sensitivity of the sensor, anti-rabbit IgG antibody was used. After flowing the mixture of free TNT and anti-TNP antibody, anti-rabbit IgG antibody was injected, and the incidence angle shift was measured. Amplification of the signal was observed and the detection limit was improved to 1 × 10−11 g/ml.  相似文献   

17.
In order to gain biosorbent that would have the ability to bind cesium ions from water solution effectively, potassium nickel hexacyanoferrate(II) (KNiFC) was incorporated into the mushroom biomass of Agaricus bisporus. Cesium sorption by KNIFC-modified A. bisporus biosorbent was observed in batch system, using radiotracer technique using 137Cs radioisotope. Kinetic study showed that the cesium sorption was quite rapid and sorption equilibrium was attained within 1 h. Sorption kinetics of cesium was well described by pseudo-second order kinetics. Sorption equilibrium was the best described by Freundlich isotherm and the distribution coefficient was at interval 7,662–159 cmg−1. Cesium sorption depended on initial pH of solution. Cesium sorption was very low at pH0 1.0–3.0. At initial pH 11.0, maximum sorption of cesium was found. Negative effect of monovalent (K+, Na+, NH4 +) and divalent (Ca2+, Mg2+) cations on cesium sorption was observed. Desorption experiments showed that 0.1 M potassium chloride is the most suitable desorption agent but the complete desorption of cesium ions from KNiFC-modifed biosorbent was not achieved.  相似文献   

18.
Arginase isolated from beef liver was covalently attached to a polyacrylamide bead support bearing carboxylic groups activated by a water-soluble carbodiimide. The most favorable carbodiimide wasN-cyclohexyl-Nt’-(methyl-2-p-nitrophenyl-2-oxoethyl) aminopropyl carbodiimide methyl bromide, but for practical purposes,N-cyclohexyl-Nt’-morpholinoethyl carbodiimide methyl tosylate was used. The optimal conditions for the coupling procedure were determined. The catalytic activity of the immobilized arginase was 290–340 U/g solid or 2.9–3.4 U/mL wet gel. The pH optimum for the catalytic activity was pH 9.5, the apparent temperature maximum was at 60°C and Kmapp was calculated to be 0.37M L-arginine. Immobilization markedly improved the conformational stability of arginase. At 60°C, the pH for maximal stability was found to be 8.0. The immobilized arginase was used for the production of L-ornithine and D-arginine.  相似文献   

19.
Arsenic-speciation analysis in marine samples was performed by high-pressure liquid chromatography (HPLC) with ICP–MS detection. Separation of eight arsenic species—AsIII, MMA, DMA, AsV, AB, TMAO, AC and TeMAs+—was achieved on a C18 column with isocratic elution (pH 3.0), under which conditions AsIII and MMA co-eluted. The entire separation was accomplished in 15 min. The HPLC–ICP–MS detection limits for the eight arsenic species were in the range 0.03–0.23 μg L−1 based on 3σ for the blank response (n=5). The precision was calculated to be 2.4–8.0% (RSD) for the eight species. The method was successfully applied to several marine samples, e.g. oysters, fish, shrimps, and marine algae. Low-power microwave digestion was employed for extraction of arsenic from seafood products; ultrasonic extraction was employed for the extraction of arsenic from seaweeds. Separation of arsenosugars was achieved on an anion-exchange column. Concentrations of arsenosugars 2, 3, and 4 in marine algae were in the range 0.18–9.59 μg g−1. This paper was presented at the European Winter Conference 2005  相似文献   

20.
In the present work molecularly imprinted sol-gel tablet (MIP-Tablet) was prepared. The MIP-sol-gel was prepared as a thin layer on polyethylene material in a tablet form. Methadone-d9 was selected as the template and 3-(propylmethacrylate)-trimethoxysilane was used as precursor. MIP-Tablet was applied for micro-solid phase extraction (μ-SPE). The MIP-Tablet was used for the determination of methadone in human plasma samples utilizing liquid chromatography-tandem mass spectrometry; and each tablet could be used twenty times. The extraction time was 10 min while desorption time was 6 min. Factors affecting the extraction efficiency such as desorption solvents, sample pH, salt addition, extraction time, desorption time and adsorption capacity were investigated. The calibration curves were obtained within the range of 5–5000 ng/mL using methadone in human plasma samples. The coefficients of determination (r2) values were ≥0.999 for all runs and the extraction recovery was >80%. The accuracy values for quality control samples varied from +3.6 to +9.7% and the inter-day precision (RSD %) values were ranged from 5.0 to 8.0%. The limit of detection was 1.0 ng/mL and the lower limit of quantification was 5 ng/mL utilizing methadone in human plasma samples.  相似文献   