共查询到20条相似文献,搜索用时 15 毫秒
1.
Dudley E Lemière F Van Dongen W Tuytten R El-Sharkawi S Brenton AG Esmans EL Newton RP 《Rapid communications in mass spectrometry : RCM》2004,18(22):2730-2738
Modified urinary nucleosides are potentially invaluable in cancer diagnosis. High-performance liquid chromatography (HPLC) was combined with full scan mass spectrometry (MS), tandem mass spectrometry and MSn analysis in order to identify purine nucleosides purified from urine. UV peaks evident in the chromatogram were examined by the various mass spectrometric techniques and adenosine, 1-methyladenosine, xanthosine, N1-methylguanosine, N2-methylguanosine, N2,N2-dimethylguanosine, N2,N2,N7-trimethylguanosine, inosine, and 1-methylinosine were each identified in the urine samples from cancer patients. The benefits of the use of LC/MS compared with HPLC alone are discussed. 相似文献
2.
Dudley E El-Sharkawi S Games DE Newton RP 《Rapid communications in mass spectrometry : RCM》2000,14(14):1200-1207
In order to optimise the analysis of urinary nucleosides by high performance liquid chromatography/mass spectrometry (HPLC/MS), the HPLC separation of these compounds was performed at different 'flow rates' and 0.2mL/min was found to give both a better separation and ionisation. The ionisation conditions were optimised to give the best intensity of the molecules quasi-molecular ions. The ion distribution profile and ionisation in both positive and negative mode were examined and the detection of the protonated molecule in positive mode chosen for further analysis. The limits of detection of the method developed are reported and representative LC/MS and LC/MS/MS spectra shown. Typical urinary nucleoside chromatograms are presented. 相似文献
3.
Identification of bupropion urinary metabolites by liquid chromatography/mass spectrometry 总被引:1,自引:0,他引:1
Petsalo A Turpeinen M Tolonen A 《Rapid communications in mass spectrometry : RCM》2007,21(16):2547-2554
Human urinary metabolism of the antidepressant bupropion was studied using liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). A total of 20 metabolites were detected and identified. The phase I metabolism included formation of morpholinohydroxybupropion, threo- and erythrohydrobupropion, aromatic hydroxylation, butyl group hydroxylation with ketone hydrogenation and dihydroxylation. These metabolites were detected either as the free form or as glucuronide and/or sulphate conjugates. In addition also m-chlorohippuric acid was detected. Of the phase I metabolites, a dihydroxylation to the aromatic ring and to the methyl group in the middle of the substrate molecule was reported here for the first time, as well as eight of the glucuronide conjugates (to hydroxy, dihydroxy, hydroxy and hydrogenation metabolites) and three of the sulphate conjugates (to aromatic hydroxy and hydroxy and hydrogenation metabolites). 相似文献
4.
Yanru Li Haiyi Yu Wei Zhao Xinye Xu Jiang Zhou Ming Xu Wei Gao Gu Yuan 《Rapid communications in mass spectrometry : RCM》2014,28(19):2054-2058
5.
Li HY Wang SM Liu HM Li J Han D Bu SS Zhang MZ 《Rapid communications in mass spectrometry : RCM》2008,22(20):3161-3171
As modified nucleosides reflect altered tRNA turnover which seems to be impaired in the body of cancer patients, they have been evaluated as potential tumor markers. High-performance liquid chromatography/electrosprary ionization quadrupole time-of-flight mass spectrometry (HPLC/ESI-Q-TOFMS) was used to identify nucleosides purified from urine in positive ionization mode. Potential nucleosides were assessed by their evident UV absorbance in HPLC and then further examined by mass spectrometric techniques. In this manner, 21 nucleosides were detected in the urine of a patient with lymphoid cancer including three modified nucleosides 5'-dehydro-2-deoxyinosine, N1,N2,N7-trimethylguanosine and N1-methyl-N2-ethylguanosine, which had never been reported previously. 相似文献
6.
A rapid procedure for the isolation, separation, identification and measurement of urinary pyrimidine bases and nucleosides by high-performance liquid chromatography (HPLC) is presented. The initial isolation of these compounds from urine was accomplished with small disposable ion-exchange columns. HPLC was performed on a silica gel column with a mobile phase composed of methylene chloride, methanol and 1 M aqueous ammonium formate buffer. Peaks were recorded at both 254 nm and 280 nm and the response ratio was used in combination with the elution volume for compound identification. The minimum detectable amount (signal-to-noise ratio = 2) ranged from 0.2 ng for uracil to 2.2 ng for cytidine. Linearity and recovery for thymine, uracil, uridine, pseudouridine, orotic acid and orotidine added to urine was demonstrated over almost a 10(3) concentration range. The potential application of this method for the study of inborn errors in the urea cycle is discussed. 相似文献
7.
8.
Analysis of rabbit tear proteins by high-pressure liquid chromatography/electrospray ionization mass spectrometry 总被引:4,自引:0,他引:4
Zhou L Beuerman RW Barathi A Tan D 《Rapid communications in mass spectrometry : RCM》2003,17(5):401-412
The aim of this study was to develop a fast and reliable analytical procedure for the display of the protein components of tears that can be used to differentiate the status of the ocular surface. Using this new procedure, we analyzed the tear protein components following a corneal wound in the rabbit. Calibrated 10-microL glass, fire-polished capillary micropipettes were used to collect tears from New Zealand White rabbits prior to and daily for 9 days following a unilateral 6-mm diameter centrally placed anterior keratectomy. Tear proteins were eluted by a reversed-phase high-performance liquid chromatography (RP-HPLC) column and the tear protein profile was monitored by electrospray ionization (ESI) mass spectrometry positive total ion current (TIC) chromatography. Tear proteins were reliably separated into 17 peaks, each of which contained one or a number of protein components. The molecular weight of each protein component was determined by on-line ESI. Major tear protein components, lactoferrin, lysozyme (minimally detectable in rabbit tears), albumin, lipocalin, lipophilin and beta2-microglobulin, were tentatively identified by this method. Based on the mass spectrometric data, beta2-microglobulin was found to be glycosylated with N-acetylhexosamine. ESI-positive TIC chromatograms and mass spectra revealed comparative differences in the tear protein spectra after corneal wounding. One day after wounding, rabbit lysozyme with a molecular weight of 14,717 Da was found to be 8-fold higher in the tears of wounded eyes when compared with tears from unwounded eyes. It dropped back to normal 3 days after wounding. The expression of an unidentified tear protein with the molecular weight of 16,060 Da was also elevated after corneal wounding and returned to normal level by day 5. In this study, LC/ESI-MS was developed as a fast, reproducible and simple method for the identification and analysis of many of the protein components of the tears. Importantly, this technique also allows quantification of each component resolved in the chromatogram. This method is very suitable for mapping peptides and proteins (<80 kDa) in tears. 相似文献
9.
Identification of phenolic constituents in Radix Salvia miltiorrhizae by liquid chromatography/electrospray ionization mass spectrometry 总被引:2,自引:0,他引:2
The phenolic components from Radix Salvia miltiorrhizae Bunge, a well-known herbal medicine (Dan-Shen in Chinese), have been investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). HPLC analyses were performed on a reversed-phase C18 column using gradient elution. In the ESI mass spectra a predominant [M-H]- ion was observed in negative mode and provided molecular mass information. ESI-MS/MS spectra of the [M-H]- ions were used for structural analysis, based on the spectra of standards. It was found that caffeic acid and its monomeric analogs containing a carboxyl group readily lost CO2, while dimers, trimers and tetramers of caffeic acid expelled successively danshensu or caffeic acid or their esters. Twenty-eight phenolic compounds in S. miltiorrhizae were characterized, of which eight compounds were positively identified by comparison with standards. The remaining twenty phenolics for which standards were not available were tentatively identified based on their UV spectra and MS/MS fragmentation characteristics. 相似文献
10.
Antignac JP Cariou R Le Bizec B Cravedi JP Andre F 《Rapid communications in mass spectrometry : RCM》2003,17(12):1256-1264
In an international context of promoting scientific research on food safety, the interest in molecules having potential hormonal disrupting effects is growing. While industrial endocrine disruptors (phthalates, alkylphenols, PCBs, etc.) have been studied for several years, natural compounds like phytoestrogens remain less investigated. Accordingly, a research project was initiated with its main objectives to develop efficient analytical methods for a wide range of phytoestrogens in various food matrices, and to evaluate their occurrence in food products. Electrospray ionization with tandem mass spectrometric (MS/MS) analysis of isoflavones (genistein, daidzein, equol, formononetin, biochanin A), lignans (enterolactone, enterodiol), and coumestans (coumestrol) was investigated. This study revealed the formation of a large number of fragment ions in both positive and negative modes, corresponding to specific cleavages of the hydroxyl, carbonyl, and/or methoxy groups, and to Retro-Diels-Alder reactions. An LC/ESI-MS/MS method was developed consistent with the 2002/657/EC European decision criteria. An extraction and clean-up method was developed for milk samples. The identification limit for the proposed method appears to be under 1 ng/mL. The developed methodology was applied to various milk samples, and the occurrence of isoflavones (particularly equol) was demonstrated in the concentration range 1-30 ng/mL. The efficiency of the proposed analytical method permitted evaluation of a new and promising approach to a global risk assessment of natural estrogenic active substances including phytoestrogens and their metabolites. 相似文献
11.
Lemr K Hol&cbreve;apek M Jandera P Ly&cbreve;ka A 《Rapid communications in mass spectrometry : RCM》2000,14(20):1881-1888
Five metal complex azo compounds were analyzed using negative-ion electrospray ionization mass spectrometry (ESI-MS). Mass spectra of all compounds yield intense peaks corresponding to [M - H](-) ions without any fragmentation, where M denotes the neutral compound with a proton as the counterion. Under collision induced dissociation (CID) conditions, structurally important fragment ions were studied using the ion trap analyzer with a multistage mass spectrometry (MS(n) facility. Synthesized compounds with (15)N atoms in the azo group facilitated the fragmentation pattern recognition. A reversed-phase high-performance liquid chromatography (HPLC) method using 5 mM ammonium acetate in 70% aqueous acetonitrile as mobile phase was developed making possible the separation of all complex compounds tested. The lower detection limits of the ESI-MS method are in the range 10-20 ng of each compound. The HPLC/ESI-MS method makes possible the monitoring of ligand exchange in aqueous solutions of metal complex azo dyes, and also investigation of the stabilities of the complexes in solution. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
12.
Ramona Heinke Katrin Franke Katharina Michels Ludger Wessjohann Nasser Abdullah Awadh Ali Jürgen Schmidt 《Journal of mass spectrometry : JMS》2012,47(1):7-22
A series of prevailing prenylated furanocoumarins from leaves of Dorstenia gigas and Dorstenia foetida (Moraceae) were investigated by liquid chromatography/electrospray tandem mass spectrometry. The mass spectral behavior of the furanocoumarins under positive ion electrospray conditions is discussed using both an ion trap and a triple quadrupole system. It is demonstrated that both methods represent valuable tools not only for the rapid classification of this type of compounds, but also with respect to their substitution pattern. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
13.
A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (HPLC/ESI-MS) method has been developed to conclusively differentiate the epimers betamethasone and dexamethasone and various esterification products (betamethasone and dexamethasone 21-acetate, betamethasone and dexamethasone 21-phosphate, betamethasone 17-valerate, betamethasone 21-valerate and betamethasone 17,21-dipropionate) in counterfeit drugs. Good separation with baseline resolution of all epimers or isomers was obtained on a Zorbax Eclipse XDB or Luna C8 column, using a step gradient with mobile phases of 0.05 M ammonium acetate and acetonitrile. Betamethasones can also be distinguished by the relative abundance of their m/z 279 ion in the positive electrospray tandem mass spectra. The LC/MS or LC/MS/MS method developed was successfully applied to the analysis of drug product samples, i.e. creams and tablets. 相似文献
14.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented. 相似文献
15.
Crow B Bishop M Paliakov E Norton D George J Bralley JA 《Biomedical chromatography : BMC》2008,22(12):1346-1353
The separation and detection of 11 urinary aromatic acids was developed using HPLC-MS/MS. The method features a simple sample preparation involving a single-step dilution with internal standard and a rapid 8 min chromatographic separation. The accuracy was evaluated by the recovery of known spikes between 87 and 110%. Inter- and intra-assay precision (CV) was below 11% in all cases and the analytes were observed to be stable for up to 8 weeks when stored at -20 degrees C. The method was validated based upon linearity, accuracy, precision and stability and was used to establish reference intervals for children and adults. 相似文献
16.
Quantitative determination of ochratoxin A by liquid chromatography/electrospray tandem mass spectrometry 总被引:2,自引:0,他引:2
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples. 相似文献
17.
A phospholipid mixture extracted from cultured cells was directly analyzed by capillary (Cap) liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS). Using a quadrupole mass spectrometer, we analyzed positive molecular ions, negative molecular ions, positive fragment ions and negative fragment ions under four different functions. In the analysis of the elution patterns of the phospholipids, a two-dimensional map, in which the first dimension is elution time and the second dimension is mass, proved useful. Consequently, four different maps can be obtained by each of four different functions. Among them, from negative fragment ions at high cone voltage in the negative ion mode, ions that originated from acyl fatty acid and phosphorylcholine, phosphorylethanolamine and cyclic inositol phosphate can be detected at specific elution times. The map from positive fragment ions at high cone voltage in the positive ion mode indicated ions such as diradylglycerol and derivatives of 1-alkyl or 1-alkenyl cyclic phosphatidic acid from phosphatidylethanolamine (PE), and phosphorylcholine from choline-containing phospholipids. The map produced from positive molecular ions indicated choline-containing phospholipids such as phosphatidylcholine, sphingomyelin, lysophosphatidylcholine and PE. The map of negative molecular ions effectively indicated acidic phospholipids such as phosphatidylinositol. We were able to obtain more than 500 molecular species of phospholipids by this method within a few hours immediately after extraction from culture cells using a mixture of chloroform and methanol (2:1). In this context, we concluded that the combination of Cap-LC and ESIMS seems to be very effective in the analysis of phospholipid classes and their molecular species. 相似文献
18.
19.
Lu Q Zhang L Chen T Lu M Ping T Chen G 《Rapid communications in mass spectrometry : RCM》2008,22(16):2565-2572
Auxin is an important phylohormone, which regulates specific physiological responses such as division, elongation and differentiation of cells. A new method using liquid chromatography/electrospray ionization ion trap mass spectrometry (LC/ESI-ITMS) has been developed for identification and quantitation of four auxins. Under the optimum conditions, four auxins (indole-3-acetic acid, indole-3-propionic acid, indole-3-butyric acid and 1-naphthylacetic acid) were completely separated and quantitated within 7 min with a minimum detection limit of 8.0 ng mL(-1) with relative standard deviations lower than 5.0%. This method also has been applied to analysis of auxins in Chinese cabbage where, even with a complicated serious background perturbation due to the natural biological matrix, the mean recoveries ranged from 77.5% to 99.8%. Finally, we discuss the MS-relevant properties of the identified auxins in detail. 相似文献
20.
A congener-specific method based on high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ES-MS/MS) in the negative ion mode was developed for the analysis of hexabromocyclododecane (HBCDD). On a C(18) analytical column, with a methanol/water mobile phase, the alpha-isomer was completely resolved from the beta- and gamma-isomers while the beta- and gamma-isomers were sufficiently resolved at half their peak heights. The ES spray voltage strongly influenced the intensity of the ion signal. For MS, a source temperature of 500 degrees C and a collision energy of 50 eV were found to be optimum for the [M-H](-) to Br(-) transition. Run-to-run and day-to-day (n = 3) variability was minimal, with relative standard deviations of 2.6-4.1 and 2.4-4.4%, respectively. The limit of detection was 4-6 pg on-column. When applied to tissue samples from Lake Winnipeg fish both alpha- and gamma-isomers of HBCDD were found in low-ng/g (lipid corrected) concentrations. 相似文献