首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper 1‐(2‐pyridylazo)‐2‐naphthol (PAN) and ionic liquid 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) were mixed with graphite powder to get a modified carbon paste electrode (PAN‐IL‐CPE), which was further used for the sensitive determination of bismuth(III). By the co‐contribution of the formation of PAN‐Bi complex and the accumulation effect of IL, more bismuth(III) was electrodeposited on the surface of the PAN‐IL‐CPE. Then the reduced Bi was oxidized and detected by differential pulse anodic stripping voltammetry (DPASV) with the oxidation peak appeared at 0.17 V (vs. SCE). Under the optimal conditions the oxidation peak current was proportional to the bismuth(III) concentration in the range from 0.04 to 7.5 μmol L?1 with the detection limit as 3.9 nmol L?1. The proposed method was successfully applied to the stomach medicine sample detection with good recovery.  相似文献   

2.
L ‐Tyrosine can exhibit a small anodic peak on multiwalled carbon nanotubes (MWCNTs) coated glassy carbon electrodes (GCE). At pH 5.5 its peak potential is 0.70 V (vs. SCE). When an ionic liquid (i.e., 1‐octyl‐3‐methylimidazolium hexafluorophosphate, [omim][PF6]) is introduced on the MWCNT coat, the peak becomes bigger. Furthermore, in the presence of Cu2+ ion the anodic peak of L ‐tyrosine increases further due to the formation of Cu2+‐L ‐tyrosine complex, while the peak potential keeps unchanged. Therefore, a sensitive voltammetry based on the oxidation of Cu2+‐L ‐tyrosine complex on MWCNTs‐[omim][PF6] composite coated electrode is developed for L ‐tyrosine. Under the optimized conditions, the anodic peak current is linear to L ‐tyrosine concentration in the range of 1×10?8–5×10?6 M, and the detection limit is 8×10?9 M. The modified electrode shows good reproducibility and stability. In addition, the voltammetric behavior of other amino acids is explored. It is found that among them tryptophan (Trp) and histidine (His) can also produce sensitive anodic peak under same experimental conditions, and their detection limits are 4×10?9 M and 4×10?6 M, respectively.  相似文献   

3.
利用3,6-二氧杂-1,8-辛二硫醇(H2L)和HgCl2反应,得到组成为Hg3L2Cl2的配合物。制备了Hg3L2Cl2修饰的碳糊电极,研究了在1mol/L KCl水溶液中的循环伏安行为。研究结果表明在1mol/L KCl介质中,在0.3~-0.8V(vs.SCE)范围内出现Hg3L2Cl2的还原和L^2-在汞膜表面的吸附,在一0.30—0.30V范围内出现汞膜的氧化还原反应。  相似文献   

4.
报道了利用辛可宁修饰碳糊电极测定铋的方法,在1mol/LH2SO4溶液中,通过在-1.00V电位下富集Bi3+后,在-0.20~+0.15V电位范围内作阳极溶出伏安法测定。在-0.022V处有一灵敏的氧化峰,峰电流与Bi  相似文献   

5.
A room temperature ionic liquid N‐butylpyridinium hexafluorophosphate (BPPF6) was used as a binder to make an ionic liquid modified carbon paste electrode (IL‐CPE), which showed good characteristics such as simple preparation procedure, fast electrochemical response and good conductivity. The electrochemical oxidation of ascorbic acid (AA) on the new IL‐CPE was carefully studied. The oxidation peak potential of AA on the IL‐CPE appeared at 109 mV (vs. SCE), which was about 338 mV decrease of the overpotential compared to that obtained on the traditional carbon paste electrode (CPE) and the oxidation peak current was increased for about four times. The electrochemical parameters of AA on the IL‐CPE were calculated with the charge transfer coefficient (α) and the electrode reaction rate constant (ks) as 0.87 and 0.800 s?1, respectively. Based on the relationship of the oxidation peak current and the concentration of AA a sensitive analytical method was established with cyclic voltammetry. The linear range for AA determination was in the range from 1.0×10?5 to 3.0×10?3 mol/L with the linear regression equation as Ip (μA)=?2.52–0.064C (μmol/L) (n=13, γ=0.9942) and the detection limit was calculated as 8.0×10?6 mol/L (3σ). The proposed method was free of the interferences of coexisting substances such as dopamine (DA) and amino acids etc., and successfully applied to the vitamin C tablets determination.  相似文献   

6.
《Analytical letters》2012,45(13):2569-2579
Abstract

A method for determination of L‐dopa by the adsorption stripping voltammetry (ASV) using a multiwalled carbon nanotubes (MWNTs)–Nafion modified glassy carbon electrode (GMGCE) was proposed. This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed and the anodic peak potential is ca. 0.374V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of L‐dopa in samples. There is a good linear relationship between the peak current (ip) and L‐dopa concentration in the range of 3.5×10?7~1.5×10?5 mol/L, with the limit of detection 5.0×10?8 mol/L.  相似文献   

7.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

8.
碳糊电极阳极吸附伏安法测定大黄酸   总被引:5,自引:0,他引:5  
在pH4.2的HAc-NaAc底液中,大黄酸在碳糊电极(CPE)上有一灵敏的吸附氧化峰,峰电位为1.14V(vs.SCE)。该氧化峰的二阶导数峰电流与大黄酸的浓度在8.0×10-9~8.0×10-7mol/L(富集120s)范围内呈良好的线性关系(r=0.998),检出限为2×10-9mol/L(S/N=3,富集180s)。探讨了大黄酸在CPE上的伏安性质和电极反应机理,并将本法应用于中药大黄中的大黄酸的测定,结果良好。  相似文献   

9.
《Electroanalysis》2005,17(14):1309-1316
The detection limit (about 0.017 μg mL?1) for voltammetric determination of iodide (peak at +0.87 V vs. Ag/AgCl at pH 2) at a glutaraldehyde‐cross‐linked poly‐L ‐lysine modified glassy carbon electrode involving oxidation to iodine was found to be several orders of magnitude lower than that for the voltammetric determination on a bare glassy carbon electrode. This method was applied successfully to the determination of iodide in two medicinal formulations. Idoxuridine was determined indirectly at the same electrode by accumulating it first at ?0.8 V vs. Ag/AgCl. At this potential the C? I bond in the adsorbed idoxuridine is reduced giving iodide, which is then determined at the modified electrode. The method was successfully applied to the determination of idoxuridine in a urine sample.  相似文献   

10.
在0.01mol.L-1硼砂溶液(pH 9.18)中,用纳米二氧化铈修饰碳糊电极作为工作电极,线性扫描伏安法测定苯酚。伏安图上出现一灵敏的氧化峰,其峰电位为+0.56V(vs.SCE),峰电流与苯酚的浓度在1.0×10-7~2.0×10-4 mol.L-1范围内呈线性关系,检出限(3s/k)为5.0×10-8 mol.L-1。富集时间为30s,同时采用线性扫描伏安法研究苯酚在纳米二氧化铈修饰碳糊电极上的氧化还原反应,结果表明此电极反应为一不可逆的吸附过程。  相似文献   

11.
This paper describes the preparation of a new sensor based on Zn‐ferrite modified glassy carbon paste electrode and its electrochemical application for the determination of trace Cd(II) ions in waste waters using differential pulse anodic stripping voltammetry (DPASV). Different Zn/Ni ferrite nanoparticles were synthesized and characterized using scanning electron microscopy (SEM) and X‐ray powder diffraction (XRPD). The prepared ferrite nanoparticles were used for the preparation of Zn‐ferrite‐modified glassy carbon paste electrode (ZnMGCPE) for determination of Cd(II) at nanomolar levels in waste water at pH 5. The different parameters such as conditions of preparation, Zn2+/Ni2+/Fe2+ ratio and electrochemical parameters, percentage of modifier, accumulation time, pH and accumulation potential were investigated. Besides, interference measurements were also evaluated under optimized parameters. The best voltammetric response was observed for ZnFe2O4 modifier, when the percentage of modifier was 3 %, accumulation time 9 min, pH of supporting electrolyte 5 and accumulation potential ?1.05 V. Thus prepared electrode displays excellent response to Cd(II) with a detection limit of 0.38 ppb, and selective detection toward Cd(II) was achieved.  相似文献   

12.
《Analytical letters》2012,45(7):1289-1298
Abstract

Poly (acridine orange) (PAO) film–modified electrode was prepared by the electrooxidation of Acridine orange on a glassy carbon electrode (GCE) for the detection of hydroquinone in the presence of o‐hydroquinone and m‐hydroquinone. The electrochemical behavior of hydroquinone on the modified electrode was investigated with respect to different solution acidity, scan rate, and accumulation time. A pair of sharp and well‐defined peaks was obtained at 0.45 and 0.42 V [vs. a saturated calomel electrode (SCE)] at the PAO film–modified electrode. The potential difference between this pair of cathodic and anodic peaks was decreased to only 30 mV as compared to the 241 mV that was obtained on the bare glassy carbon electrode (GCE). As to o‐hydroquinone and m‐hydroquinone, their corresponding oxidation peaks appeared at 0.55 V and 0.89 V (vs. SCE), respectively. The oxidation potential differences between these three isomers enabled the separate detection of hydroquinone. Under the optimum experimental situation, the oxidation peak current of hydroquinone was proportional to the concentration at the range of 6.8×10?7–9.6×10?5 M. The detection limit was been estimated as 3×10?7 M with 130 s accumulation. This method was applied to the hydroquinone detection in tap water samples.  相似文献   

13.
A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg2+, Pb2+, Cd2+, Cu2+, and Zn2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, "cleaning" solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 microg L(-1). The precision of determination was satisfactory for the respective concentration level.  相似文献   

14.
研究了黄嘌呤在离子液体-纳米金-碳纳米管修饰玻碳电极上的电化学行为。结果表明,在0.1mol/L磷酸盐(pH=4.4)介质中,修饰电极对黄嘌呤氧化具有强的电催化作用,黄嘌呤在0.9V(vs.SCE)左右产生一灵敏的氧化峰。在优化的实验条件下,用此峰测定黄嘌呤的线性范围为1.5×10-7~1.0×10-5mol/L,检出限为3.5×10-8mol/L。该修饰电极具有良好的重现性和稳定性。  相似文献   

15.
Brilliant blue FCF‐modified glassy carbon electrodes have been prepared by cycling the Nafion (or poly(diallyldimethylammonium chloride) (PDDAC)) coated electrodes repeatedly 15 cycles in brilliant blue FCF (BB FCF) dye solution. The BB FCF molecules are incorporated into Nafion coating by cycling the film‐covered electrode between +0.3 to 1.2 V (vs. Ag/AgCl) in pH 1.5 BB FCF solution while PDDAC‐coated electrode cycled between 0 to ?1.0 V (vs. Ag/AgCl) in pH 6.5 BB FCF solution to immobilize the dye. Electrostatic interaction between dye molecule and PDDAC was predominant in PDDAC coating whereas immobilization of dye in Nafion film attributed to the combined effect of electrostatic and hydrophobic interactions. The voltammetric features of BB FCF‐modified electrodes resemble that of surface‐confined redox couples. The peak potentials of BB FCF‐incorporated PDDAC‐coated electrode were shifted to more positive potential region with decreasing pH of contacting solution. BB FCF‐modified electrodes showed electrocatalytic activity towards reduction of oxygen and oxidation of L ‐cysteine with significant decease of overvoltage compared to unmodified electrode. The BB FCF‐modified Nafion‐coated electrode was tested for its analytical applications toward determination of L ‐cysteine. The linear range of calibration plot at BB FCF‐modified Nafion‐coated electrode is 10 to 100 μM, which coincides with L ‐cysteine levels in biological fluids. Sensitivity and detection limit of the electrode are 111 nA μM?1 and 0.5 μM, respectively.  相似文献   

16.
Multilayers of myoglobin (Mb) with ionic liquid 1‐ethyl‐3‐methylimidazolium tetrafluoroborate ([EMIM]BF4) was assembled on carbon ionic liquid electrode (CILE) based on the electrostatic attraction between the negatively charged Mb and the positively charged imidazolium ion of IL. The CILE was fabricated with 1‐ethyl‐3‐methylimidazolium ethylsulfate ([EMIM]EtOSO3) as the modifier, which exhibited imidazolium ion on the electrode surface. Then Mb molecules were assembled on the surface of CILE step‐by‐step to get a {IL/Mb}n multilayer film modified electrode. UV‐Vis adsorption and FT‐IR spectra indicated that Mb remained its native structure in the IL matrix. In deaerated phosphate buffer solution (pH 7.0) a pair of well‐defined quasi‐reversible redox peaks appeared with the apparent formal potential (E0′) as ‐0.212 V (vs. SCE), which was the characteristic of Mb heme Fe(III)/Fe(II) redox couples. The results indicated that the direct electron transfer of Mb was realized on the modified electrode. The {IL/Mb}n/CILE displayed excellent electrocatalytic ability to the trichloroacetic acid reduction in the concentration range from 2.0 to 22.0 mmol/L with the detection limit of 0.6 mmol/L (3σ). The proposed method provides a new platform to fabricate the third generation biosensor based on the self‐assembly of redox protein with ILs.  相似文献   

17.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

18.
运用伏安法研究了吲哚美辛在单壁碳纳米管修饰电极上的电化学行为.在0.1 mol/L HAc-NaAc缓冲溶液(pH 4.5)中,吲哚美辛于0.91 V (vs.SCE)电位处有一个峰形很好的氧化峰.与裸玻碳电极相比,吲哚美辛在修饰电极上的电位正移了约30 mV,峰电流增加了近10倍,表明该修饰电极对吲哚美辛有较强的电催化作用.搅拌条件下开路富集2 min,氧化峰电流与吲哚美辛在5.5×10-7~1.1×10-5 mol/L浓度范围内呈良好的线性关系,检出限为1.1×10-7 mol/L.该方法可用于药剂中吲哚美辛的分析.  相似文献   

19.
《Electroanalysis》2003,15(21):1693-1698
The voltammetric behaviors of uric acid (UA) and L ‐ascorbic acid (L ‐AA) were studied at well‐aligned carbon nanotube electrode. Compared to glassy carbon, carbon nanotube electrode catalyzes oxidation of UA and L ‐AA, reducing the overpotentials by about 0.028 V and 0.416 V, respectively. Based on its differential catalytic function toward the oxidation of UA and L ‐AA, the carbon nanotube electrode resolved the overlapping voltammetric response of UA and L ‐AA into two well‐defined voltammetric peaks in applying both cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which can be used for a selective determination of UA in the presence of L ‐AA. The peak current obtained from DPV was linearly dependent on the UA concentration in the range of 0.2 μM to 80 μM with a correlation coefficient of 0.997. The detection limit (3δ) for UA was found to be 0.1 μM. Finally, the carbon nanotube electrode was successfully demonstrated as a electrochemical sensor to the determination of UA in human urine samples by simple dilution without further pretreatment.  相似文献   

20.
《Analytical letters》2012,45(13):2562-2573
Abstract

A sensing system for uracil was constituted by using lanthanum hydroxide nanowires (LNW) as a modifier to obtain LNW modified carbon paste electrode (LNW/CPE) and by introducing copper(II) ion into supporting electrolyte to transform electroinactive uracil to electroactive uracil‐Cu(II) complex. The voltammetric behaviors of uracil in the presence of Cu(II) ion at LNW/CPE were investigated. A reduction peak of the uracil‐Cu(II) complex at ?0.18 V was the two‐electron reduction of Cu(II) ion in the uracil‐Cu(II) complex; while a new oxidation peak at 0.22 V was the one‐electron oxidation of the uracil‐Cu(I) complex. Additionally, the voltammetric responses of all the complexes at LNW/CPE were more sensitive than that at carbon and multiwall carbon nanotube paste electrodes, which resulted from both the large surface effect of LNW and the chemical coordination of uracil with La(III) ion in LNW. With the sensitive oxidation peak of the uracil‐Cu(I) complex at LNW/CPE, a linear range of 4.0×10?9?3.0×10?8 mol/l for uracil was obtained along with a detection limit of 2.0×10?10 mol/l. The proposed system was evaluated by the determination of uracil derivatives, anticancer drug 5‐flurouracil, in pharmaceutical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号