首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new multi-residue method for determination of pesticide residues in a wide variety of fruit and vegetables, using the National Food Administration (NFA) ethyl acetate extraction and determination by means of LC-MS/MS, is presented. The method includes pesticides normally detected by LC-UV or LC-fluorescence such as benzimidazoles, carbamates, N-methylcarbamates and organophosphorus compounds with an oxidisable sulphide group as well. After extraction with ethyl acetate, the extract is concentrated and an aliquot of the extract is evaporated to dryness and redissolved in methanol before injection on LC-MS/MS. The method has been validated for 57 different pesticides and metabolites. Representative species from different commodity groups were chosen as matrices in order to study the influence from different matrices on recoveries. The fortification levels studied were 0.01-0.5 mg kg(-1). Matrix effects were tested for all matrices by means of standard addition to blank extracts. The matrix effect, expressed as signal in solvent compared to signal in matrix, was in general found to be small. The obtained recoveries are, with a few exceptions, in the range 70-100%. The proposed method is quick and straightforward and no additional clean-up steps are needed. The method can be used for the analysis of all 57 pesticides in one single determination step at 0.01 mg kg(-1).  相似文献   

2.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) method for the determination of amoxicillin (AMO) in animal feed was developed and validated. The method was used to examine the quality requirements for products intended for incorporation into animal feedingstuffs (medicated premixes), as documented in the EMEA/CVMP/080/95-Final guideline. After addition of the internal standard (ampicillin), the medicated feed samples were extracted using a 0.01 M potassium dihydrogenphosphate buffer solution (pH 4.5), followed by a centrifugation and filtration step. An appropriately diluted aliquot of the extract was analysed on a PLRP-S polymeric column (150 mm x 2.1 mm i.d., 100 A) using a mixture of 0.1% formic acid in water and acetonitrile as the mobile phase. Gradient elution was performed at a flow-rate of 0.2 mL min(-1). The mass spectrometer was used in the positive electrospray ionization MS/MS mode. The LC-MS/MS method was validated for linearity, trueness, precision, limit of quantification, limit of detection and specificity. The results fell within the ranges specified. The method was used for the homogeneity and stability testing of AMO in a commercial medicated feed. Some extracts were also injected onto a LC-UV and LC-fluorescence instrument (after pre-column derivatization with a formaldehyde reagent). These experiments showed that the LC-MS/MS method was superior with regard to speed of analysis, selectivity and sensitivity.  相似文献   

3.
Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration standards prepared in a tissue homogenate. This approach provides insufficient control of the homogenization process. In this paper, tissue quality control samples were introduced for the optimization of the homogenization process during method development, but also allowance for the performance evaluation of the entire analytical process. In addition, a new approach using rabbit blood as a homogenization medium was developed to stabilize sirolimus in rabbit tissue homogenates. Calibration standards and quality controls were prepared by spiking different sirolimus working solutions into rabbit blood. Homogenization quality control samples were prepared by injecting other sirolimus working solutions into empty test tubes and pre-cut arteries within pre-defined masses. A high-throughput homogenization procedure was optimized based on the specific chemical properties of sirolimus. The linear dynamic range was between 49.9 pg/mL and 31.9 ng/mL to accommodate the expected artery homogenate concentrations. Additionally, quality controls in rabbit blood were also used in the extraction to support the calibration standards. The accuracy and precision of the quality controls in rabbit blood reflect the extraction performance and the accuracy and precision of the homogenization tissue quality controls reflect the overall performance of the method. The mean bias was between -4.5 and 0.2% for all levels of quality controls in the blood and between 4.8 and 14.9% for all levels of the homogenization tissue quality controls. The CVs of all concentration levels were < or =5.3% for the quality controls in blood and < or =9.2% for the homogenization tissue quality controls. The method was successfully applied to determine the concentration of sirolimus in the rabbit arteries.  相似文献   

4.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry via electrospray ionization (ESI) source (HPLC-MS/MS) has been developed and validated for the determination of anethole trithione (ATT) in human plasma. Diazepam was employed as the internal standard (IS). Sample extracts following liquid-liquid extraction were injected into the HPLC-MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of methanol and aqueous ammonium acetate solution (5 mM) (80:20, v/v) .The ions were detected by a triple quadrupole mass spectrometric detector in the positive mode. Quantification was performed using selected reaction monitoring (SRM) of the transitions m/z 240.88 → 197.91 and m/z 285.01 → 193.02 for ATT and for the IS, respectively. The analysis time for each run was 5.0 min. The calibration curve fitted well over the concentration range of 0.02-5 ng mL−1, with the regression equation y = 1.1014x + 0.0003631, r = 0.9992. The intra-batch and inter-batch R.S.D.% were less than 15% at all concentration levels within the calibration range. The recoveries were more than 80%. The present method provides a modern, rapid and robust procedure for the pharmacokinetic study of ATT. Some important pharmacokinetic parameters of ATT in healthy Chinese volunteers are also given for the first time.  相似文献   

5.
Four cation-exchange materials, possessing propanesulfonic acid ligands, for use in capillary electrochromatography were prepared from different commercially available 5-microm bare-silica particles ranging from 80 to 800 A in pore size. The performance of the materials was investigated at different compositions of the mobile phase (pH, ionic strength, and acetonitrile content) using tricyclic antidepressants and related quaternary ammonium analogues as test analytes. The wide-pore materials promoted pore flow, but this had no positive influence on the performance. The small-pore (highest surface area) particles gave, as could be expected, the best selectivity.  相似文献   

6.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry (HPLC–MS/MS) has been developed and validated for the determination of cilnidipine, a relatively new calcium antagonist, in human plasma. The reversed-phase chromatographic system was interfaced with a TurboIonSpray (TIS) source. Nimodipine was employed as the internal standard (IS). Sample extracts following protein precipitation were injected into the HPLC–MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of CH3OH and NH4Ac (96:4, v/v). The ions were detected by a triple quadrupole mass spectrometric detector in the negative mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 491.2 → 122.1 and m/z 417.1 → 122.1 for cilnidipine and for the IS, respectively. The analysis time for each run was 3.0 min. The calibration curve fitted well over the concentration range of 0.1–10 ng mL−1, with the regression equation Y = (0.103 ± 0.002)X + (0.014 ± 0.003) (n = 5), r = 0.9994. The intra-day and inter-day R.S.D.% were less than 12.51% at all concentration levels within the calibration range. The recoveries were between 92.71% and 97.64%. The long-term stability and freeze-thaw stability were satisfying at each level. The present method provides a modern, rapid and robust tool for pharmacokinetic studies of cilnidipine.  相似文献   

7.
Salsolinol, 1‐methyl‐6,7‐dihydroxy‐2,3,4,5‐tetrahydroisoquinoline (SAL), is a precursor of a Parkinsonian neurotoxin, N‐methysalsolinol (N‐methyl‐SAL). Previous studies have shown that individual enantiomers of N‐methyl‐SAL possess distinct neurotoxicological properties. In this work, a chiral high‐performance liquid chromatography (HPLC) method with electrospray ionization tandem mass spectrometric (ESI‐MS/MS) detection was developed for the quantification of (R/S)‐SAL enantiomers. Enantioseparation was achieved on a β‐cyclodextrin‐bonded silica gel column, and the resolved enantiomers were detected by ESI‐MS/MS operated in positive ion mode. The ESI collision‐induced dissociation (CID) mass spectrum of SAL was studied together with that of its deuterium‐labeled analog (i.e. salsolinol‐α,α,α,1‐d4, SAL‐d4) so that the fragmentation pathways could be elucidated. Further, using SAL‐d4 as internal standard in HPLC/MS/MS analysis of SAL improved significantly assay accuracy and reliability. Determination of (R/S)‐SAL enantiomers present in food samples such as dried banana chips was demonstrated. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
Summary The applicability of solid-phase extraction-LC using two short columns (SPE-LC) and/or single-short-column liquid chromatography (SSC) combined on-line with tandem mass spectrometry (MS) was demonstrated for the rapid study of pesticide degradation. A fast analytical procedure was developed to provide preliminary information concerning experimental conditions, approximate rates of degradation and identity of the degradation products. Surface water samples were spiked at relevant concentration levels with well-known microcontaminants and photolysis was used to transform parent compounds into their degradation products. In general, the strategy was as follows: at 30-min intervals 10-mL samples were on-line enriched, separated by short-column LC and recorded in full-scan MS to obtain information on the disappearance of the parent compound and the appearance of breakdown products. To obtain structural information, product-ion spectra of selected compounds appearing in the full-scan MS chromatogram were recorded; this enabled the identification of several degradation products. Total analysis time of enrichment/separation and detection was about 10–15 min.  相似文献   

9.
The feasibility of quantitative bioanalysis by parallel-column liquid chromatography in conjunction with a conventional single-source electrospray mass spectrometer has been investigated using plasma samples containing a drug and its three metabolites. Within a single chromatographic run time, sample injections were made alternately onto each of two analytical columns in parallel at specified intervals, with a mass spectrometer data file opened at every injection. Thus, the mass spectrometer collected data from two sample injections into separate data files within a single chromatographic run time. Therefore, without sacrificing the chromatographic separation or the selected reaction monitoring (SRM) dwell time, the sample throughput was increased by a factor of two. Comparing the method validation results obtained using the two-column system with those obtained using the corresponding conventional single-column approach, the methods on the two systems were found to be equivalent in terms of accuracy and precision. The parallel-column system is simple and can be implemented using existing laboratory equipment with no additional capital outlays. A parallel-column system configured in this manner can be used not only for the within-a-run analysis of two samples containing two different sets of chemical entities, but also for the within-a-run analysis of two samples containing the same set of chemical entities.  相似文献   

10.
An optimized high-performance liquid chromatographic method coupled with tandem mass spectrometric detection (LC-MS/MS) was developed for the simultaneous determination of honokiol and magnolol in Magnolia officinalis. Honokiol and magnolol were separated from the extracts using a reversed-phase C(18) column with a mobile phase consisted of acetonitrile and water (75:25, v/v) at a flow-rate of 0.8 mL/min. Selected reaction monitoring (SRM) mode was used for all sample quantification by the precursor-ion/product ion pair m/z 265 --> m/z 224 for honokiol and m/z 265 --> m/z 247 for magnolol. Validation data showed that this method has good linearity (r(2) > 0.995) over the concentration range of 0.0025-0.5 microg/mL for honokiol and magnolol, and both intra- and inter-day variability were acceptable within 15% at the lowest concentrations for this method. This proposed method provides excellent specificity, higher sensitivity and shorter run time than conventional methods and was applied successfully to determine the contents of honokiol and magnolol in M. officinalis.  相似文献   

11.
A sensitive method for determination of disaturated phosphatidylserine species in the presence of their monounsaturated analogs has been developed, using micro liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The hydrophobic nature of the phosphatidylserine species required a combination of low-eluting sample solvents and sub-ambient temperatures in order to focus large sample volumes up to 20 microL. The samples were dissolved in 2-propanol:hexane:water (20:10:4, v/v/v) prior to 1:9 dilution with ammonium formate buffer:2-propanol:tetrahydrofuran (30:55:15, v/v/v) and final 1:4 dilution with ammonium formate buffer (10 mM):2-propanol: tetrahydrofuran (55:37.5:7.5, v/v/v). The analytical column was a 0.5 x 150 mm stainless steel column packed with 5 microm C30 particles, while the mobile phase contained ammonium formate buffer (10 mM): 2-propanol:tetrahydrofuran (30:55:15, v/v/v). A temperature program from 5 degrees C (hold for 3 minutes) to 75 degrees C at 8 K/min provided separation of the disaturated phosphatidylserine species from their monounsaturated analogs, making available a sensitive determination of the isobaric species. The mass limit of detection for dipalmitoyl phosphatidylserine was 100 pg, corresponding to a concentration limit of detection of 5 pg/microL when using an injection volume of 20 microL. This is an improvement by a factor of 20 as compared to previously reported numbers obtained with conventional LC columns. The within-assay precision of dipalmitoyl phosphatidylserine was 11.9% RSD (n = 3), while the retention time precision was 4.1% RSD (n = 6).  相似文献   

12.
Cross-contamination among wells of a high-throughput, high-density assay is a risk that cannot be detected or controlled by the performance of calibration standards and quality control samples. In the current practice, carryover and cross-contamination is detected only when analytes are detected in blank, zero, placebo, pre-dose samples, in a low standard or low quality control sample. There is no mechanism that allows bioanalytical scientists to determine if cross-contamination has occurred among other samples. As a result, erroneous results can be released to clients even though a batch meets the acceptance criteria. We tested a new approach that quantifies the cross-contamination of each sample and allows the scientist to make quality decisions with documentation. The approach will also detect carryover in over 90% of the wells. Briefly, two additional analytes were added as contamination markers. The markers were added to a multi-well plate alternatively creating a pattern of a checkerboard. The spiked multi-well plate was then used to perform the assay. If both markers were detected in a well, the sample was considered contaminated. The amount of the unexpected marker detected in a well measures the degree of contamination and may be used to make deactivation decisions. Depending on the relative impact of the contamination, a scientist can choose to tolerate the bias, reject the sample, reject the batch or raise the lower limit of quantitation for the batch. A guideline for rejection decisions is presented for discussion.  相似文献   

13.
1,3-Butadiene, a common air pollutant formed in the combustion of organic matter, has been assessed by the U.S. EPA to be a strongly carcinogenic compound. This risk assessment is very uncertain because of the lack of information on the dose of the powerful carcinogenic metabolite diepoxybutane (DEB). This report presents an analytical method for in vivo dose monitoring of a unique marker for DEB. For a large number of alkylating agents in vivo doses are monitored by measurement by gas chromatography/mass spectrometry (GC/MS) of adducts to N-terminal valine in hemoglobin (Hb), using a modified Edman degradation method. This method is applicable to monofunctional epoxides from butadiene. However, in reaction with N-terminal valine, DEB forms an adduct which is ring-closed to a pyrrolidine, N,N-(2,3-dihydroxy-1,4-butadiyl)valine, with a tertiary amino group that prevents detachment of the alkylated valine by the Edman reagent. Therefore a method has been developed based on the analysis by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) of the N-modified N-terminal peptides enriched after trypsin digestion of globin. In this study Hb samples from mice injected intraperitoneally with (+/-)-DEB were examined qualitatively and quantitatively with regard to the ring-closed adduct. The N-terminal pyrrolidine-heptapeptide was identified in treated mice. The highest adduct levels were obtained in samples from animals given the highest dose of DEB and the adduct levels were below the detection level in control mice.  相似文献   

14.
A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.  相似文献   

15.
A multiresidue method based on extraction with ethyl acetate has been used at the Swedish National Food Administration since 1989 to monitor pesticide residues in fruit and vegetables. The method has been continuously adjusted, resulting in simple and quick analyses of pesticide residues. To recover basic pesticides, the addition of an alkali is necessary. The addition of sodium hydrogen carbonate has been shown to recover all pesticides effectively without any degradation. The liquid chromatography (LC) with tandem mass spectrometry (MS/MS) technique has made it possible to analyse more polar pesticides and to replace many single methods. The latest development in the multiresidue method, comprising the use of gas chromatography (GC) with MS/MS, has further improved the analysis by replacing the conventional GC detectors. The need for cleanup has been reduced or eliminated entirely. Consequently, the method has been simplified in a way that makes it possible to recover all included analytes in many different matrices in one single extraction and to detect them either with GC-MS/MS or with LC-MS/MS.  相似文献   

16.
A rapid, sensitive and selective method has been developed for the direct determination of ethephon residues in vegetables (apple, cherry and tomato). Given the anionic character of ethephon, the use of ion-pairing liquid chromatography (LC) in combination with tandem mass spectrometry (MS/MS, triple quadrupole) allowed its direct determination in these matrices avoiding a derivatisation step and favouring the automation of the method. Samples were extracted with a mixture of dichloromethane/aqueous formic acid (pH 3) (1:1). Then, tetrabutylammonium acetate (TBA) was added as an ion-pairing reagent, and an aliquot of the aqueous extract was directly injected into the LC/MS/MS system. Quantification was performed with matrix-matched standards prepared from blank sample extracts. MS/MS measurements were made in the selected reaction monitoring (SRM) mode, using the most sensitive transition (m/z 107 > 79) for quantification, and up to four additional transitions for confirmation. Quantitative recoveries were obtained for all matrices (between 83% and 96%) at two concentration levels tested (0.05 and 0.5 mg/kg), with relative standard deviations lower than 9% in all cases. The addition of TBA directly into the sample extract contained in the injection vial was found sufficient to obtain satisfactory LC retention for the analyte. Under these conditions, the absence of ion-pairing reagent in the mobile phase minimised the ionisation suppression for ethephon in the MS source, leading to an increase in the sensitivity of the method and reaching limits of detection of 0.02 mg/kg for all matrices investigated. The acquisition of five specific MS/MS transitions for ethephon allowed the simultaneous and reliable quantification and confirmation of the analyte in the samples.  相似文献   

17.
An ion-pairing high-performance liquid chromatographic (IP-HPLC) system interfaced with an atmospheric pressure chemical ionization (APCI) source and a tandem mass spectrometer (MS/MS) with minimal sample preparation was developed for the determination of cytarabine (ara-C), a very hydrophilic anticancer drug, in mouse plasma. A conventional reversed-phase chromatographic column in combination with two ion-pairing reagents was adapted for retention and separation of ara-C from the endogenous interferences in mouse plasma. The effects of the experimental conditions such as the fraction of ion-pairing reagents and organic solvents in the mobile phase on the chromatographic performance and the ionization efficiency of ara-C were investigated. The potential of ionization suppression resulting from the endogenous biological materials on the IP-HPLC/MS/MS method was evaluated using the post-column infusion technique. Furthermore, the feasibility of the proposed IP-HPLC/MS/MS procedure for analysis of ara-C in the mouse plasma was demonstrated by comparison with those obtained by the porous graphite carbon column (PGC) HPLC/MS/MS method.  相似文献   

18.
Sensitive and high-throughput bioanalytical assays are of vital importance to drug discovery and development. Ultra-performance liquid chromatography (UPLC), utilizing sub-2-microm particles, greatly increases the separation throughput and efficiency, resulting in LC peaks as narrow as or less than 1 s (full width at half maxima, FWHM). This, however, could pose practical challenges for bioanalytical applications using quadrupole mass spectrometry (MS) to acquire sufficient data points to ensure accurate and reliable quantitation. Here, we present a novel 'peak parking' strategy to reduce the flow rate during UPLC peak elution, therefore extending the useful MS acquisition window. The high-throughput advantage of UPLC is maintained since no significant increase of the overall UPLC run time is needed. This strategy was demonstrated in an assay development for lansoprazole, a gastric proton-pump inhibitor, in human plasma employing liquid-liquid extraction. The method was validated from 50.0 to 50,000 pg/mL.  相似文献   

19.
Nifedipine is a dihydropyridine calcium channel blocker used widely in the management of hypertension and other cardiovascular disorders. In this work, a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated to determine nifedipine in dog plasma using nimodipine as the internal standard. Chromatographic separation was carried out on a C8 column. The mobile phase consisted of a mixture of acetonitrile, water and formic acid (60:40:0.2, v/v/v) at a flow rate of 0.5 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode via an atmospheric pressure chemical ionization source. The method has a lower limit of quantification of 0.20 ng/mL with consumption of plasma as low as 0.05 mL. The linear calibration curves were obtained in the concentration range of 0.20–50.0 ng/mL (r = 0.9948). The recoveries of the liquid extraction method were 74.5–84.1%. Intra‐day and inter‐day precisions were 4.1–8.8 and 6.7–7.4%, respectively. The quantification was not interfered with by other plasma components and the method was applied to determine nifedipine in plasma after a single oral administration of two controlled‐release nifedipine tablets to beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine valproic acid in human plasma. The method involved a solid-phase extraction of valproic acid and betamethasone valerate, an internal standard, from plasma and detection using an LC-MS/MS system with electrospray ionization source in negative ion mode. Separation was achieved within 3 min on a non-porous silica column with mobile phase containing ammonium acetate and methanol. Multiple reaction monitoring was utilized for detection monitoring at 142.89-142.89 for valproic acid and 457.21-457.21 for the internal standard. The calibration curve for valproic acid was linear over the range of 0.5-150 microg/mL. The limit of detection was 0.17 microg/mL and the lower limit of quantification was 0.5 microg/mL, when 0.2 mL plasma was used for extraction. The percentage coefficient of validation for accuracy and precision (inter- and intra-day) for this method was less than 9.5% with recovery ranging from 82.3 to 86.9% for valproic acid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号