首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
DNA analysis of degraded samples and low-copy number DNA derived from skeletal remains, one of the most challenging forensic tasks, is common in disaster victim identification and genetic analysis of historical materials. Massively parallel sequencing (MPS) is a useful technique for STR analysis that enables the sequencing of smaller amplicons compared with conventional capillary electrophoresis (CE), which is valuable for the analysis of degraded DNA. In this study, 92 samples of human skeletal remains (70+ years postmortem) were tested using an in-house MPS-STR system designed for the analysis of degraded DNA. Multiple intrinsic factors of DNA from skeletal remains that affect STR typing were assessed. The recovery of STR alleles was influenced more by DNA input amount for amplification rather than DNA degradation, which may be attributed from the high quantity and quality of libraries prepared for MPS run. In addition, the higher success rate of STR typing was achieved using the MPS-STR system compared with a commercial CE-STR system by providing smaller sized fragments for amplification. The results can provide constructive information for the analysis of degraded sample, and this MPS-STR system will contribute in forensic application with regard to skeletal remain sample investigation.  相似文献   

2.
A fluorescence energy transfer (ET) dye-labeled STR typing system (ET 16-plex) is developed for the markers used in the commercial STR typing kit PowerPlex 16, and its performance assessed using a 96-lane microfabricated capillary array electrophoresis (muCAE) system. The ET 16-plex amplicons displayed 1.6-9-fold higher fluorescence intensities compared to those produced using the single-dye (SD)-labeled multiplex kits. The ET multiplex delivered full STR profiles from 62.5 pg of DNA; half the input required for the SD kits while maintaining a similar heterozygote allele balance. This increased sensitivity should improve typing of poor-quality DNA samples by making minor or imbalanced alleles more readily detectable at the low copy number (LCN) threshold. The ET 16-plex also generated complete profiles with only 28 PCR cycles; this capability should improve LCN typing by reducing the amplification time and drop-in allele incidence. To confirm the practical advantages of ET-labeled primers, six previously problematic casework samples were tested and only the ET 16-plex kit was able to capture additional allele data. The successful development and demonstration of ET primers for higher sensitivity STR typing offers a simple solution to improving current commercial multiplex typing capability. The superior spectral properties and universal compatibility with any primer sequence provided by ET cassettes will make future multiplex construction more facile and straightforward. The pairing of ET cassette technology with the muCAE system illustrates not only an enhanced STR typing platform, but a significant step toward a higher-efficiency forensic laboratory enabled by better chemistry and microfluidics.  相似文献   

3.
Lab‐on‐a‐chip provides an ideal platform for short tandem repeat (STR) genotyping due to its intrinsic low sample consumption, rapid analysis, and high‐throughput capability. One of the challenges, however, in the forensic human identification on the microdevice is the detection sensitivity derived from the nanoliter volume sample handling. To overcome such a sensitivity issue, here we developed a sample stacking CE microdevice for mini Y STR genotyping. The mini Y STR includes redesigned primer sequences to generate smaller‐sized PCR amplicons to enhance the PCR efficiency and the success rate for a low copy number and degraded DNA. The mini Y STR amplicons occupied in the 5‐ and 10‐mm stacking microchannels are preconcentrated efficiently in a defined narrow region through the optimized sample stacking CE scheme, resulting in more than tenfold improved fluorescence peak intensities compared with that of a conventional cross‐injection microcapillary electrophoresis method. Such signal enhancement allows us to successfully analyze the Y STR typing with only 25 pg of male genomic DNA, with high background of female genomic DNA, and with highly degraded male genomic DNA. The combination of the mini Y STR system with the novel sample stacking CE microdevice provides the highly sensitive Y STR typing on a chip, making it promising to perform high‐performance on‐site forensic human identification.  相似文献   

4.
Butler JM  Buel E  Crivellente F  McCord BR 《Electrophoresis》2004,25(10-11):1397-1412
DNA typing with short tandem repeat (STR) markers is now widely used for a variety of applications including human identification. Capillary electrophoresis (CE) instruments, such as the ABI Prism 310 and ABI 3100 Genetic Analyzers, are the method of choice for many laboratories performing STR analysis. This review discusses issues surrounding sample preparation, injection, separation, detection, and interpretation of STR results using CE systems. Requirements for accurate typing of STR alleles are considered in the context of what future analysis platforms will need to increase sample throughput and ease of use.  相似文献   

5.
《Electrophoresis》2018,39(12):1466-1473
Massively parallel sequencing (MPS) technologies, also termed as next‐generation sequencing (NGS), are becoming increasingly popular in study of short tandem repeats (STR). However, current library preparation methods are usually based on ligation or two‐round PCR that requires more steps, making it time‐consuming (about 2 days), laborious and expensive. In this study, a 16‐plex STR typing system was designed with fusion primer strategy based on the Ion Torrent S5 XL platform which could effectively resolve the above challenges for forensic DNA database‐type samples (bloodstains, saliva stains, etc.). The efficiency of this system was tested in 253 Han Chinese participants. The libraries were prepared without DNA isolation and adapter ligation, and the whole process only required approximately 5 h. The proportion of thoroughly genotyped samples in which all the 16 loci were successfully genotyped was 86% (220/256). Of the samples, 99.7% showed 100% concordance between NGS‐based STR typing and capillary electrophoresis (CE)‐based STR typing. The inconsistency might have been caused by off‐ladder alleles and mutations in primer binding sites. Overall, this panel enabled the large‐scale genotyping of the DNA samples with controlled quality and quantity because it is a simple, operation‐friendly process flow that saves labor, time and costs.  相似文献   

6.
Improved STR typing of telogen hair root and hair shaft DNA   总被引:1,自引:0,他引:1  
Today the STR typing of telogen hair and hair shafts is regarded as a challenge. The small DNA quantity in the hair is highly degraded. Another problem are PCR inhibitors in the hair. In particular hair pigments, the melanins, are known to inhibit PCR. Hairs are exposed to sunlight and partly to chemical oxidation processes, which make them even more difficult to analyze. To increase the chances of a correct typing of hair, the small amount of DNA must be successfully isolated and the inhibitors have to be removed or neutralized. Furthermore, miniSTR typing improves the analysis of stains with degraded DNA like it is the case with hair. We introduce a nonorganic extraction method and in addition a miniSTR concept which is promising in typing stains with little and degraded DNA, especially hairs. The miniSTR concept including five database STRs (SE33, VWA, TH01, FGA, D3S1358) and the gender typing system Amelogenin was optimized for the amplification of hair DNA. Compared to commercial STR kits, this approach resulted in considerably higher success rates.  相似文献   

7.
There is growing interest in developing additional DNA typing techniques to provide better investigative leads in forensic analysis. These include inference of genetic ancestry and prediction of common physical characteristics of DNA donors. To date, forensic ancestry analysis has centered on population‐divergent SNPs but these binary loci cannot reliably detect DNA mixtures, common in forensic samples. Furthermore, STR genotypes, forming the principal DNA profiling system, are not routinely combined with forensic SNPs to strengthen frequency data available for ancestry inference. We report development of a 12‐STR multiplex composed of ancestry informative marker STRs (AIM‐STRs) selected from 434 tetranucleotide repeat loci. We adapted our online Bayesian classifier for AIM‐SNPs: Snipper, to handle multiallele STR data using frequency‐based training sets. We assessed the ability of the 12‐plex AIM‐STRs to differentiate CEPH Human Genome Diversity Panel populations, plus their informativeness combined with established forensic STRs and AIM‐SNPs. We found combining STRs and SNPs improves the success rate of ancestry assignments while providing a reliable mixture detection system lacking from SNP analysis alone. As the 12 STRs generally show a broad range of alleles in all populations, they provide highly informative supplementary STRs for extended relationship testing and identification of missing persons with incomplete reference pedigrees. Lastly, mixed marker approaches (combining STRs with binary loci) for simple ancestry inference tests beyond forensic analysis bring advantages and we discuss the genotyping options available.  相似文献   

8.
Microsatellite markers were developed for Cannabis sativa L. (marijuana) to be used for DNA typing (genotype identification) and to measure the genetic relationships between the different plants. Twelve different oligonucleotide probes were used to screen an enriched microsatellite library of Cannabis sativa in which 49% of the clones contained microsatellite sequences. Characterization of microsatellite loci in Cannabis revealed that GA/CT was the most abundant class of the isolated microsatellites representing 50% overall followed by GTT/CAA, AAG/TTC, and GAT/CTA representing 16%, 15%, and 10%, respectively. Eleven polymorphic STR markers were developed, three derived from dinucleotide motifs and eight from trinucleotide motifs. A total of 52 alleles were detected averaging 4.7 alleles/locus. The expected heterozygosity of the eleven loci ranged between 0.368 and 0.710 and the common probability of identical genotypes was 1.8×10–7. The loci identified 27 unique profiles of the 41 Cannabis samples. The 11 microsatellite markers developed in this study were found to be useful for DNA typing and for assessing genetic relatedness in Cannabis.  相似文献   

9.
We report on the effects of six dyes used in the detection of DNA on the process of DNA extraction, amplification, and detection of STR loci. While dyes can be used to detect the presence of DNA, their use is restricted if they adversely affect subsequent DNA typing processes. Diamond? Nucleic Acid Dye, GelGreen?, GelRed?, RedSafe?, SYBR® Green I, and EvaGreen? were evaluated in this study. The percentage of dye removed during the extraction process was determined to be: 70.3% for SYBR® Green I; 99.6% for RedSafe?; 99.4% for EvaGreen?; 52.7% for Diamond? Dye; 50.6% for GelRed?, and; could not be determined for GelGreen?. It was then assumed that the amount of dye in the fluorescent quantification assay had no effect on the DNA signal. The presence of all six dyes was then reviewed for their effect on DNA extraction. The t‐test showed no significant difference between the dyes and the control. These extracts were then STR profiled and all dyes and control produced full DNA profiles. STR loci in the presence of GelGreenTM at 1X concentration showed increased amplification products in comparison to the control samples. Full STR profiles were detected in the presence of EvaGreen? (1X), although with reduced amplification products. RedSafe? (1X), Diamond? Dye (1X), and SYBR® Green I (1X) all exhibited varying degrees of locus drop‐out with GelRed? generating no loci at all. We provide recommendations for the best dye to visualize the presence of DNA profile as a biological stain and its subsequent amplification and detection.  相似文献   

10.
A DNA sample was partially degraded by scalar heat-acid treatments to study the extent of apurinic-apyrimidinic (A-P) lesions produced along the molecule. A CE-UV method allowed us to measure the rate of depurination at pH 5.0 and 70°C which was calculated to be 5.41×10(-6) s(-1) for adenine and 6.27×10(-6) s(-1) for guanine. CE identified depurination on treated samples when it occurred with a loss of >4% of the basic moieties. The molecular features of the A-P enriched samples were investigated by using molecular assays (agarose gel electrophoresis, UV spectrophotometry and quantitative PCR) and the consistency of the results of the STR typing were compared with the degree of depurination of the PCR template. The treated DNA samples showed molecular features such as fragmentation, altered OD(260) /OD(280) ratios and decreased ability of the quantitative PCR to synthesise the human target, related to the severity of depurination. A satisfactory correlation between the degree of damage and the amount of residual PCR-sensitive target sequences was also demonstrated (r(2) =0.9717). The conventional and mini-STR typing of the samples showed that the genetic outcome was influenced by a depurination damage that exceeded 4% when locus drop-outs and artefactual PCR results were evident. As the success of STR typing depends on the integrity of the DNA recovered from the samples, the CE-UV, physical and molecular assays described here are proposed as a set of useful methods in the analysis of certain forensic and clinical samples, for a critical evaluation of the outcome of the genetic testing.  相似文献   

11.
This work describes the development of a novel microdevice for forensic DNA processing of reference swabs. This microdevice incorporates an enzyme‐based assay for DNA preparation, which allows for faster processing times and reduced sample handling. Infrared‐mediated PCR (IR‐PCR) is used for STR amplification using a custom reaction mixture, allowing for amplification of STR loci in 45 min while circumventing the limitations of traditional block thermocyclers. Uniquely positioned valves coupled with a simple rotational platform are used to exert fluidic control, eliminating the need for bulky external equipment. All microdevices were fabricated using laser ablation and thermal bonding of PMMA layers. Using this microdevice, the enzyme‐mediated DNA liberation module produced DNA yields similar to or higher than those produced using the traditional (tube‐based) protocol. Initial microdevice IR‐PCR experiments to test the amplification module and reaction (using Phusion Flash/SpeedSTAR) generated near‐full profiles that suffered from interlocus peak imbalance and poor adenylation (significant ?A). However, subsequent attempts using KAPA 2G and Pfu Ultra polymerases generated full STR profiles with improved interlocus balance and the expected adenylated product. A fully integrated run designed to test microfluidic control successfully generated CE‐ready STR amplicons in less than 2 h (<1 h of hands‐on time). Using this approach, high‐quality STR profiles were developed that were consistent with those produced using conventional DNA purification and STR amplification methods. This method is a smaller, more elegant solution than current microdevice methods and offers a cheaper, hands‐free, closed‐system alternative to traditional forensic methods.  相似文献   

12.
A single multiplex PCR assay capable of simultaneously amplifying nine canine‐specific autosomal STR markers (FH3210, FH3241, FH2004, FH2658, FH4012, REN214L11, FH2010, FH2361 and the newly described C38) was developed for individual identification and parentage testing in domestic dogs. In order to increase genotyping efficiency, amplicon sizes were optimized for a 90–350 bp range, with fluorescently labelled primers for use in Applied Biosystems, Inc., platforms. The performance of this new multiplex system was tested in 113 individuals from a case‐study population and 12 random dogs from mixed‐breed origin. Co‐dominant inheritance of STR alleles was investigated in 101 father, mother and son trios. Expected heterozygosity values vary between 0.5648 for REN214L11 and 0.9050 for C38. The high level of genetic diversity observed for most markers provides this multiplex with a very high discriminating power (matching probability=1.63/1010 and matching probability among siblings=4.9/103). Allele sequences and a proposal for standardized nomenclature are also herein presented, aiming at implementing the use of this system in forensic DNA typing and population genetic studies. This approach resulted in an optimized and well‐characterized canine DNA genotyping system that is highly performing and straightforward to integrate and employ routinely. Although this STR multiplex was developed for use and tested in a case‐study population, the Portuguese breed Cão de Gado Transmontano, it proved to be useful for general identification purposes or parentage testing.  相似文献   

13.
DNA profiling of short tandem repeats (STR) has been successfully used for the identification of individuals in forensic samples, accidents and natural disasters. However, STR profiling of DNA isolated from old crime scenes and damaged biological samples is difficult due to DNA degradation and fragmentation. Here, we show that pre‐amplification of STR loci using biotinylated primers for the STR loci is an efficient strategy to obtain STR profiling results from fragmented forensic samples. Analysis of STR loci with longer amplicon sizes is generally hampered, since these relatively long loci are vulnerable to DNA fragmentation. This problem was overcome by using reduced or increased primer concentrations for loci with shorter or longer amplicon sizes, respectively, in our pre‐amplification strategy. In addition, pre‐amplification of STR loci into two groups of short or long amplicon size increases the efficiency of STR profiling from highly fragmented forensic DNA samples. Therefore, differential pre‐amplification of STR loci is an effective way to obtain DNA profiling results from fragmented forensic samples.  相似文献   

14.
With the advent of forensic DNA profiling in the mid-1980s, this technology has had a positive impact on the criminal justice system, helping to convict the guilty and exonerate the innocent. The field has evolved from focusing on multilocus markers throughout the nuclear DNA genome to the use of autosomal short tandem repeat (STR) markers. Other marker systems such as mitochondrial DNA and Y-chromosomal STR testing have also found an important niche for the identification of missing persons and historical investigations. Given the importance of forensic DNA testing, it is critical that laboratories include proper controls and validated procedures for making quality measurements. In the United States, the National Institute of Standards and Technology (NIST) developed several standard reference materials (SRMs) to meet the needs of the forensic DNA community. Here, we discuss a brief history of forensic DNA testing and the development of NIST SRMs and educational resources for the field over the last 20 years.  相似文献   

15.
We have designed a new molecularly imprinted co‐polymer (MIP) for the sensitive detection of streptomycin (STR) in food using enzymes as signal amplification. The MIP was fabricated via co‐polymerization of aniline and o‐phenylenediamine on gold substrate in the presence of STR as template. The assay is based on competitive binding of free STR and glucose oxidase‐labeled STR (GOx‐STR) to the imprinters on the MIP. On addition of glucose, hydrogen peroxide is formed that is detected by differential pulse voltammetry. Under optimal conditions, the decrease of the catalytic current is proportional to the STR concentration in the range from 0.01 to 10 ng mL?1, with a detection limit (LOD) of 7.0 pg mL?1 STR (at 3sB). Intra‐ and inter‐assay coefficients of variation (CVs) are<10.5 %. The system was further validated and evaluated with STR‐spiked samples including honey and milk, and the recovery was between 82 and 124.2 %.  相似文献   

16.
Short tandem repeat (STR) loci, widely used as genetic markers in disease diagnostic studies and human identity applications, are traditionally genotyped through comparison of allele sizes to a sequenced allelic ladder. Allelic ladders permit a floating bin allele calling method to be utilized, which enables reliable allele calling across laboratories, instrument platforms, and electrophoretic conditions. Precise sizing methods for STR allele calling involving fixed bins can also be used when a high degree of precision has been demonstrated within an instrument platform and a set of electrophoretic conditions. An alternative method for reliable genotyping of STR markers, locus-specific brackets (LSBs), is introduced here. LSBs are artificial alleles created through molecular biology manipulations to be shorter or longer than alleles commonly seen in populations under investigation. The size and repeat number of measured alleles are interpolated between the two LSB products that are mixed with the polymerase chain reaction-amplified STR alleles. The advantages and limitations of the LSB approach are described along with a concordance study between the LSB typing approach and other STR typing methods. Complete agreement was observed with 162 samples studied at 5 Y-chromosome loci.  相似文献   

17.
Forensic analysis of mitochondrial displacement loop (D‐loop) sequences using Sanger sequencing or SNP detection by minisequencing is well established. Pyrosequencing has become an important alternative because it enables high‐throughput analysis and the quantification of individual mitochondrial DNAs (mtDNAs) in samples originating from more than one individual. DNA typing of the mitochondrial D‐loop region is usually the method of choice if STR analysis fails because of trace amounts of DNA and/or extensive degradation. The main aim of the present work was to optimize the efficiency of pyrosequencing. To do this, 31 SNPs within the hypervariable regions I and II of the D‐loop of human mtDNA were simultaneously analyzed. As a novel approach, we applied two sets of amplification primers for the multiplexing assay. These went in combination with four sequencing primers for pyrosequencing. This method was compared with conventional sequencing of mtDNA from blood and biological trace materials.  相似文献   

18.
Human identification is usually based on the study of STRs or SNPs depending on the particular characteristics of the investigation. However, other types of genetic variation such as insertion/deletion polymorphisms (indels) have considerable potential in the field of identification, since they can combine the desirable characteristics of both STRs and SNPs. In this study, a set of 38 non‐coding bi‐allelic autosomal indels reported to be polymorphic in African, European, and Asian populations were selected. We developed a sensitive genotyping assay, which is able to characterize all 38 bi‐allelic markers using a single multiplex PCR and detected with standard CE analyzers. Amplicon length was designed to be shorter than 160 bp. Complete profiles were obtained using 0.3 ng of DNA, and full genotyping of degraded samples was possible in cases where standard STR typing had partially failed. A total of 306 individuals from Angola, Mozambique, Portugal, Macau, and Taiwan were studied and population data are presented. All indels were polymorphic in the three population groups studied and the random match probabilities of the set ranged in orders of magnitude from 10?14 to 10?15. Therefore, the indel‐plex represents a valuable approach in human identification studies, especially in challenging DNA cases, as a more straightforward and efficient alternative to SNP typing.  相似文献   

19.
The ability to detect DNA polymorphisms using molecular genetic techniques has revolutionized the forensic analysis of biological evidence. DNA typing now plays a critical role within the criminal justice system, but one of the limiting factors with the technology is that DNA isolated from biological stains recovered from the crime scene is sometimes so damaged as to be intractable to analysis. Potential remedies for damaged DNA are likely to be dependent upon the precise nature of the DNA damage present in any particular sample but, unfortunately, current knowledge of the biochemical nature, and the extent, of such DNA damage in dried biological stains is rudimentary. As a model for DNA damage assessment in biological stains recovered from crime scenes, we have subjected human bloodstains and naked DNA in the hydrated and dehydrated states to varying doses of UVC radiation. It was possible to damage the DNA sufficiently in a bloodstain to cause a standard autosomal short tandem repeat (STR) profile to be lost. However, a detailed analysis of the process, based upon assays developed to detect bipyrimidine photoproducts (BPPPs), single- and double-strand breaks, and DNA–DNA crosslinks, produced some unexpected findings. Contrary to the situation with living tissues or cells in culture, the predominant UVC-induced damage to DNA in bloodstains appears not to be pyrimidine dimers. Although some evidence for the presence of BPPPs and DNA crosslinks was obtained, the major form of UVC damage causing genetic profile loss appeared to be single-strand breaks. It was not possible, however, to preclude the possibility that a combination of damage types was responsible for the profile loss observed. We demonstrate here that a significant measure of protection against UVC-mediated genetic profile loss in dried biological stain material is afforded by the dehydrated state of the DNA and, to a lesser extent, the DNA cellular milieu.  相似文献   

20.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号