首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work describes a novel type of bismuth electrode for stripping voltammetry based on coating a silicon substrate with a thin bismuth film by means of sputtering. The bismuth-based sensors were characterized by optical methods (scanning electron microscopy (SEM), atomic force microscopy (AFM) and X-ray diffraction (XRD)) and as well as by linear sweep voltammetry. Subsequently, the electrodes were tested for the detection of low concentrations of trace metals (Cd(II), Pb(II) and Ni(II)) by stripping voltammetry. Well-formed stripping peaks were observed for trace concentrations of the target analytes demonstrating “proof-of-principle” for these sensors. This type of electrochemical device, utilizing thin-film technology for the formation of the bismuth film, holds promise for future applications in trace metal analysis.  相似文献   

2.
微波消解-铋膜修饰电极阳极溶出法测定大米中镉   总被引:1,自引:0,他引:1  
建立了大米中Cd的微波消解壤膜电极阳极溶出伏安快速测定方法.在0.2 mol/L HAc-NaAc缓冲溶液(pH 4.0)中,Cd(Ⅱ)在-650mV附近出现一灵敏的溶出峰,其质量浓度在1~360 μg/L范围内与峰高成正比,检出限可达0.05 μg/L,回收率为93.5%~106.3%;本法已用于大米中Cd的测定,并...  相似文献   

3.
Hydrogen evolution bothers stripping analysis significantly. Dioctyl phthalate-based carbon paste electrode exhibits extremely wide cathodic potential window. It is explored as a powerful substrate electrode to solve the problem of hydrogen evolution and further improve reproducibility for stripping analysis using bismuth-coated electrodes for the first time. It was successfully applied to the simultaneous determination of Zn2+, Cd2+, and Pb2+. Linear responses are obtained for Zn2+ in the range of 10–100 μg L−1 and for Pb2+ and Cd2+ in the range of 5–100 μg L−1. The detection limits for Zn2+, Cd2+, and Pb2+ are 0.1 μg L−1, 0.22 μg L−1 and 0.44 μg L−1, respectively. The method has been successfully applied to the determination of Zn2+, Cd2+, and Pb2+ in waste water samples. The detection strategy based on the combination of dioctyl phthalate-based carbon paste electrode and bismuth-coated electrodes holds great promise for stripping analysis.  相似文献   

4.
The most essential limitation of batch-injection analysis (BIA) methodology compared to other flow methods (CFA, FIA, SIA) is the lack of possibility of on-line sample processing in the measuring system. Some procedures of on-line sample pretreatment in BIA are possible by changing the plastic tip of the automatic micropipette used for sample injection into a flow-through reactor, e.g. by packing it with a bed of a solid sorbent. This concept is employed in the voltammetric stripping determinations of trace metals using a bed of commercial chelating resin Chelex-100. It was found that, besides the electrochemical preconcentration of analytes in the form of amalgams on the surface of mercury thin film electrodes, an approximately 10-fold additional preconcentration can be achieved on the packed sorbent bed by using different volumes of aspirated sample solution and eluent. This procedure allows also efficient elimination of some matrix effects.  相似文献   

5.
Kokkinos C  Economou A 《Talanta》2011,84(3):696-701
This work is a study of the analytical utility of Nafion-modified microfabricated bismuth film electrodes (BiFEs) for the determination of Pb(II) and Cd(II) by anodic stripping voltammetry (ASV) in the presence of surfactants. Micro-fabricated BiFEs were prepared by depositing a thin film of bismuth on the surface of a silicon substrate by sputtering while the two-dimensional geometry of the final sensors was defined by photolithography. The BiFEs were further drop-coated with a Nafion film. These devices were applied to the determination of Pb(II) and Cd(II) by square wave ASV (SWASV) in the presence of Triton X-100 (a non-ionic surfactant), cetyltrimethylammonium bromide (CTAB) (a cationic surfactant) and sodium dodecyl sulphate (SDS) (an anionic surfactant). It was found that the presence of Nafion afforded an increase in sensitivity and the tolerance against surfactants but these properties were severely influenced by both the thickness of the Nafion film and the nature of the interfering surfactant. Using a Nafion of 0.4 μm thickness and 120 s of preconcentration, the repeatability (expressed as the % relative standard deviation on the same sensor (n = 8)) at the 20 μg l−1 level was 3.8% for Pb(II) and 3.1% for Cd(II) and the limits of detection were 0.5 μg l−1 for Cd(II) and Pb(II). The sensors were applied to Cd(II) and Pb(II) determination in a certified lake-water sample.  相似文献   

6.
本文报道了Nafion汞膜修饰电极及其用于阳极溶出伏安法测定未处理尿样,水样及土样中痕量铋的研究。样品中常共存的Pb(Ⅱ)、Sb(Ⅲ )等19种阳离子及尿样中共存的有机物在实验条件下不干扰。本法不仅选择性好,而且灵敏度也较高。线性范围为2×10~(-10)~1×10~(-7)mol/L。回收率为94~105%。  相似文献   

7.
This work reports the fabrication of disposable three-electrode cells with integrated metal-film electrodes. The devices were fabricated by a multi-step micro-fabrication approach combining sputtering for the deposition of metals and the dielectric material (SiO2) on the surface of a silicon wafer and photolithography for the definition of the geometry of the sensors. The working electrode was a microelectrode array consisting of bismuth microdisks while the reference and counter electrode strips were made of Ag and Pt, respectively. The utility of these devices was tested for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry and Ni(II) by adsorptive stripping voltammetry. The detection of these trace metals was carried out in unstirred and undeoxygenated solutions exhibiting sub-μg L−1 limits of detection and enhanced analytical characteristics compared to conventional bismuth-film electrodes.  相似文献   

8.
丁二酮肟修饰碳糊电极阳极溶出伏安法测定痕量铋   总被引:1,自引:0,他引:1  
报道了用丁二酮肟修饰碳糊电极测定微量铋的电分析方法。Bi~(3+)通过与电极表面的丁二酮肟作用而富集在电极表面,同时在-0.40 V(vs.SCE)还原成零价,当电极电势从-0.40 V向0.40 V扫描时,被还原的铋从电极表面溶出,在0.03 V出现一个十分灵敏的阳极溶出峰。优化了各种实验参数,如支持电解质的选择及pH值、丁二酮肟的用量、富集电位及时间等。修饰电极测定铋的线性范围为1×10~(-9)~1×10~(-6)mol/L。富集6 min后检出限可达4×10~(-10)mol/L。该方法简便快速,灵敏度高,分析成本低廉,并成功应用于实际水样中微量铋的测定。  相似文献   

9.
A stripping chronopotentiometric method, using a rotating gold disk electrode for mercury measurements in sea water is described. Compared with a same method using a stationary gold film electrode, this method has a eight times higher sensitivity and a detection limit of 5 ng l−1 after 10 min deposition time. Moreover, the time needed for gold plating is eliminated. Compared with other electrochemical methods capable of measuring mercury at low concentrations, the present method is more simplified with no degassing step and no need to use a medium-exchange procedure before the stripping step. These characteristics render the method easily practicable on board oceanographic vessels for ‘in situ’ measurements.  相似文献   

10.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

11.
An in situ plated lead film electrode has been applied for adsorptive stripping voltammetric determination of trace concentrations of molybdenum in the presence of Alizarin S. The procedure is based on the preconcentration of the molybdenum-Alizarin S complex at an in situ plated lead film electrode held at −0.6 V (versus Ag/AgCl), followed by a negatively sweeping square wave voltammetric scan. The peak current is proportional to the concentration of molybdenum over the range 2 × 10−9 to 5 × 10−8 mol L−1, with a 3σ detection limit of 9 × 10−10 mol L−1 with an accumulation time of 60 s. The measurements were carried out from underaerated solutions. The proposed procedure was validated in the course of Mo(VI) determination in water certified reference materials.  相似文献   

12.
The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1 × 10−8 to 70 × 10−8 mol L−1 and from 1 × 10−9 to 70 × 10−9 mol L−1 respectively, were obtained. The calculated limit of detection (LOD), for 30 s of the accumulation time, was 3 × 10−9 mol L−1 for Ni(II) in case of a single element’s analysis, whereas the LOD was 5 × 10−9 mol L−1 for Ni(II) and 3 × 10−10 mol L−1 for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n = 5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results.  相似文献   

13.
In this work, we describe an automated stripping analyzer operating on a hybrid flow-injection/sequential-injection (FIA/SIA) mode and utilizing a bismuth-film electrode (BiFE) as a flow-through sensor for on-line stripping voltammetry of trace metals. The instrument combines the advantages of FIA and SIA and is characterised by simplicity, low-cost, rapidity, versatility and low consumption of solutions. The proposed analytical flow methodology was applied to the determination of Cd(II) and Pb(II) by anodic stripping voltammetry (ASV) and of Ni(II) and Co(II) by adsorptive stripping voltammetry (AdSV). The steps of the rather complex experimental sequence (i.e. the bismuth-film formation, the analyte accumulation, the voltammetric stripping and the electrode cleaning/regeneration) were conducted on-line and the critical parameters related to the respective analytical procedures were investigated. In ASV, for a accumulation time of 180 s the limits of detection for Cd(II) and Pb(II) were 2 and 1 μg l−1, respectively (S/N = 3) and the relative standard deviations were 5.3% and 4.7%, respectively (n = 8). In AdSV, for a total sample volume of 1000 μl, the limits of detection for Ni(II) and Co(II) were 1 μg l−1 (S/N = 3) and the relative standard deviations were 5.5% and 6.2%, respectively (n = 8). The measurement frequency ranged between 15 and 20 stripping cycles h−1. The results indicate that the BiFE is well suited as a flow-through detector for on-line stripping analysis and, by virtue of its low toxicity, can serve as a viable alternative to mercury-based flow-through electrodes.  相似文献   

14.
For the first time an in situ plated bismuth film electrode has been applied to catalytic adsorptive stripping voltammetry of cobalt in the presence of nitrite. At optimised conditions bismuth film was plated before each measurement for 30 s at ?1.0 V from a sample solution with the added supporting electrolyte and Bi(III) in the form of its complex with tartrate. The calibration graph for Co(II) for an accumulation time of 120 s was linear from 5×10?10 to 1×10?8 mol L?1. The detection limit was 1.1×10?10 mol L?1. The proposed procedure was applied for Co(II) determination in certified water reference material.  相似文献   

15.
A procedure for trace thallium determination by anodic stripping voltammetry at a bismuth film electrode is presented. Measurements were performed in a flow system. The calibration graph was linear from 2×10?9 to 3×10?8 mol L?1 for an accumulation time of 300 s. A detection limit for Tl+ following deposition time of 300 s was 6×10?10 mol L?1. The relative standard deviation at Tl+ concentration 2×10?8 mol L?1 was 3.9%. For determination of thallium in complex matrices the procedure for elimination of interferences from foreign ions exploiting anion exchange resin was proposed. The procedure proposed was validated by analysis of rain water certified reference material.  相似文献   

16.
This paper describes a new procedure for the determination of Sb (III) and Sb (V) by differential pulse adsorptive stripping voltammetry (DPAdSV) using pyrogallol as a complexing agent. The selection of the experimental conditions was made using experimental design methodology. The detection limits obtained were 1.03 × 10−10 and 9.48 × 10−9 mol dm−3 for Sb (III) and Sb (V), respectively.In order to carry out the simultaneously determination of both antimony species a partial least squares regression (PLS) is employed to resolve the voltammetric signals from mixtures of Sb (III) and Sb (V) in the presence of pyrogallol. The relative error in absolute value is less than 0.5% when concentrations of several mixtures are calculated. Moreover, the solution is analyzed for any possible effects of foreign ions. The procedure is successfully applied to the speciation of antimony in pharmaceutical preparations and water samples.  相似文献   

17.
The objective of this study was to exploit the advantages of stripping chronopotentiometry (SCP) and stripping chronopotentiometry at scanned deposition potential (SSCP) for trace metal speciation analyses by using thin-film mercury screen-printed electrodes (TMF-SPE). At first, the SCP parameters were optimised for TMF-SPE, in order to reach the complete depletion regime. It has been shown that a stripping current higher than or equal to 10 μA allows this regime to be attained without removing oxygen from the solution.Then, these analytical conditions were used for the construction of SSCP curves for Cd-PDCA and Cd-NTA. When the concentration of free ligand in solution was known, the knowledge of the model describing the SSCP curves in absence and presence of a complex and the use of an effective fitting tool enabled estimating the stability constant and the rate constants for complexation. Further studies with complexes of restricted mobility are however necessary to assess the usefulness of this procedure to also estimate the diffusion coefficient of the complexes. Besides, this study showed that this approach was valid even when ligands were not in excess at the electrode during stripping.  相似文献   

18.
Adsorptive stripping voltammetry is a very sensitive and selective method for determination of drugs and organic substances in biological fluids. We have shown that determination of testosterone by adsorptive stripping voltammetry is possible using a lead film electrode. The lead film plating process and accumulation of testosterone were performed simultaneously from an acetate buffer solution of pH = 5.2 at a potential of −1.1 V. The measurements were carried out in undeaerated solutions. The detection limit was 9 × 10−9 mol L−1 for an accumulation time of 120 s; the relative standard deviation for 1 × 10−7 mol L−1 testosterone was 3.8%. The proposed voltammetric procedure for determination of testosterone could be applied to its determination in a pharmaceutical preparation and human urine samples directly without any separation steps.  相似文献   

19.
碳糊修饰电极吸附伏安法测定食品中的锑   总被引:3,自引:0,他引:3  
研制了溴邻苯三酚红 (BPR)作修饰剂的碳糊修饰电极 ,并用此电极作工作电极建立了测定痕量锑的吸附伏安法。在选定的实验条件下 ,峰电流与Sb(Ⅲ )浓度在 8.0× 1 0 -9~ 2 .0× 1 0 -7mol L范围内呈线性关系 ,检出限为 2 .0×1 0 -9mol L ,1 0次测定相对标准偏差为 2 .0 % ,不用分离 ,可直接测定食品中痕量Sb(Ⅲ ) ,测定的回收率为 90 %~ 1 0 3%。  相似文献   

20.
A simple, rapid and reliable procedure for the determination of tin by galvanic stripping analysis is described. The determination includes (i) preconcentration of tin onto preformed mercury film glassy carbon electrode, and (ii) re-oxidation in open-circuit position by advantageously utilizing the localized galvanic couple formation (in the absence of external electrical field or oxidant in solution). The details of the development of such a procedure and its application to the determination of tin in pure zinc materials are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号