首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 929 毫秒
1.
Peng CF  Huo TM  Liu LQ  Chu XG  Xu CL 《Electrophoresis》2007,28(6):970-974
A rapid and simple method is developed for the determination of medroxyprogesterone acetate (MPA) by CE immunoassay with chemiluminescence (CL). This method is based on the competitive reactions between horseradish peroxidase (HRP)-labeled MPA (MPA-HRP) and free MPA with anti-MPA antiserum. The influencing factors on the electrophoresis and CL detection were studied completely and the optimal conditions of separation and determination were obtained. The linear range was 2.0-50 nmol/L and the LOD for MPA was 0.9 nmol/L. The present method was applied to the analysis of pork tissues.  相似文献   

2.
A polyclonal antibody against ochratoxin A (OTA) was produced from rabbits immunized with the OTA–BSA conjugate. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a membrane-base colloidal gold immunoassay in flow-through format were developed for the rapid detection of OTA in various food matrices. In the cdELISA, the concentration causing 50% inhibition was 0.07 ng mL−1, and the effects of different chemical conditions (ionic strength, pH value, and organic solvent) were studied. The sensitivity of the assay was higher than those previously reported. A simple, rapid, and efficient extraction method was developed and 74–110% recoveries of spiked samples were obtained. Fifty percent methanol extracts of some food samples such as barley, wheat, oat, corn, rice, and raisins could be analyzed directly by immunoassay after dilution in PBS; grape juice and beer samples could be analyzed directly after dilution with PBS; for coffee samples, a more complex method was used to remove the matrix effect effectively. Membrane-based colloidal gold immunoassays had a visual detection limit of 1.0 ng mL−1 for OTA with a detection time of less than 10 min. For the validation of the cdELISA and membrane-based colloidal gold immunoassay, samples were analyzed by high-performance liquid chromatography. The correlation between data obtained using the microwell assay and HPLC was good (R 2 = 0.984). The developed immunoassay methods are suitable for the rapid quantitative or qualitative determination of OTA in food samples.  相似文献   

3.
《Analytical letters》2012,45(3):505-518
Abstract

An indirect competitive chemiluminescent enzyme-linked immunosorbent assay (CL-ELISA) for detection of gatifloxacin residue in milk was developed in this study. Compared with conventional colorimetric ELISA using the same antibody, the developed CL immunoassay shows a significant improvement in sensitivity and detectability with an IC50 of 0.4 ng mL?1 and a detection limit of 0.001 ng mL?1 and thus is suitable to be used as a highly sensitive screening method to detect and regulate illegal use of gatifloxacin in food and food products. The test kit was applied to detect milk samples spiked by gatifloxacin, and satisfactory results were obtained.  相似文献   

4.
A sensitive competitive flow injection chemiluminescence (CL-FIA) immunoassay for immunoglobulin G (IgG) was developed using gold nanoparticle as CL label. In the configuration, anti-IgG antibody was immobilized on a glass capillary column surface by 3-(aminopropyl)-triethoxysilane and glutaraldehyde to form immunoaffinity column. Analyte IgG and gold nanoparticle labeled IgG were passed through the immunoaffinity column mounted in a flow system and competed for the surface-confined anti-IgG antibody. CL emission was generated from the reaction between luminol and hydrogen peroxide in the presence of Au (III), generated from chemically oxidative dissolution of gold nanoparticle by an injection of 0.10 mol L−1 HCl–0.10 mol L−1 NaCl solution containing 0.10 mmol L−1 Br2. The concentration of analyte IgG was inversely related to the amount of bound gold nanoparticle labeled IgG and the CL intensity was linear with the concentration of analyte IgG from 1.0 ng mL−1 to 40 ng mL−1 with a detection limit of 5.2 × 10−10 g mL−1. The whole assay time including the injections and washing steps was only 30 min for one sample, which was competitive with CL immunoassays based on a gold nanoparticle label and magnetic separation. This work demonstrates that the CL immunoassay incorporation of nanoparticle label and flow injection is promising for clinical assay with sensitivity and high-speed.  相似文献   

5.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

6.
Wang C  Wu J  Zong C  Ju H  Yan F 《The Analyst》2011,136(20):4295-4300
A novel trace tag for chemiluminescent (CL) immunoassay was designed by using DNAzyme to functionalize antibody-labeled Au nanoparticles (AuNPs). The trace tag showed an excellent ability to catalyze the oxidation of luminol by hydrogen peroxide, leading to strong CL emission. By coupling the trace tag with a passive mixing accelerated immunoreaction system, a highly sensitive rapid flow-through CL immunoassay method was proposed. Using carcinoembryonic antigen (CEA) as a model analyte, the capture antibody for CEA was immobilized on paramagnetic microspheres, and DNAzyme-anti-CEA antibody functionalized AuNPs were prepared as trace tag. A three-dimensional helical glass tube kept at 37 °C in a water bath was used for passively mixing immunoreagents in a two-step sandwich immunoassay, with which each immunoreaction step could be finished within 150 s. With the help of a magnet, the immunocomplex could conveniently be separated from reactants. Compared with the horseradish peroxidase-based tag, the newly designed trace tag showed obvious signal amplification due to its strong catalytic ability and high loading ratio of DNAzyme on each AuNP. The proposed method showed a linear calibration range from 0.005 to 0.5 ng mL(-1) for CEA detection with a detection limit of 4.1 pg mL(-1) at a signal-to-noise ratio of 3 and acceptable detection reproducibility. The assay results of clinical serum samples were in acceptable agreement with the reference values. The designed immunoassay system with ultrahigh sensitivity provided a programmable and low-cost approach for high-throughput clinical application.  相似文献   

7.
We present a novel immunoassay format utilizing the catalytic properties of gold nanoparticles in the luminol-silver nitrate-gold nanoparticle based chemiluminescence (CL) system for the detection of widely used herbicide 2,4-dichlorophenoxyacetic acid (2,4-D). Highly sensitive anti-2,4-D antibody was produced and conjugated with gold nanoparticles of various sizes. In the present assay format, employing a competitive inhibition approach, a well-characterized hapten-protein conjugate (2,4-D-BSA) was used to coat the microtiter plates. The analyte (2,4-D) was pre-incubated with anti-2,4-D antibody labeled with gold nanoparticles and added to each well of the microtiter plate. The gold label triggered the reaction between luminol and silver nitrate generating a luminescence signal at 425 nm. Under the optimized conditions, the CL based immunoassay showed the detection limit of 2,4-D in standard water samples around 3 ng mL(-1). The CL based immunoassay format, based on gold nanoparticles as a catalyst, could be used as a fast screening methodology (<30 min) for pesticide detection.  相似文献   

8.
Immunoassays are commonly used in bioresearch for the detection and quantification of small proteins and macromolecules in biological fluids and other complex matrices. In this report, a competitive immunoassay using capillary electrophoresis (CE) with laser-induced fluorescence was developed for methionine-enkephalin (ME). The method is based on the competitive reaction between the ME and fluorescein conjugated ME (ME-F) with anti-ME antibody, capillary electrophoresis separation of the ME-antibody bound and free ME-F, followed by the laser-induced fluorescence detection of the fluorescent species. With the optimized separation conditions, it was possible to separate the antibody bound and free fluorescien conjugated ME by a capillary electrophoresis-laser-induced fluorescence (CE-LIF) analysis using an uncoated fused-silica capillaries. The results concluded that the assay specificity, selectivity and accuracy were excellent.  相似文献   

9.
以温度敏感高分子聚N-异丙基丙烯酰胺-丙烯酰胺[P(NIP-AA)]作为载体,建立了酶联荧光免疫分析人IgG的新方法。AA摩尔含量为8%的高分子P(NIP-AA)其临界溶解温度为37 °C。竞争型免疫测定中,被固定的IgG和标准溶液(或样品)在33 °C均相条件下竞争性地与辣根过氧化物酶标记抗体反应,升高温度分离出高分子免疫复合物,沉淀重新溶解后通过偶联过氧化氢与对羟基苯乙酸的荧光反应进行定量,线性范围为100-1000 ng/mL,检测限为2.0 ng/mL。方法灵敏、快速操作简便,且提高了免疫反应效率。此外,灵敏度与用传统微孔板做载体相似,但测定时间更快(从100-120分钟减少到30分钟)。该法用于测定人血清中IgG的含量,结果满意。  相似文献   

10.
Ochratoxin A (OTA) is a mycotoxin produced by filamentous fungi of the genus Aspergillus and Penicillium that presents carcinogenic, teratogenic and nephrotoxic properties. In this work, we have developed, characterized and applied an immunoassay methodology comprised of magnetic nanoparticles (MNPs) as platform for immobilizing bioactive materials incorporated into a microfluidic system for rapid and sensitive quantification of Ochratoxin A (OTA) in apples (Red Delicious) contaminated with Aspergillus ochraceus. The sensor has the potential for automation and the detection of OTA was carried out using a competitive indirect immunoassay method based on the use of anti-OTA monoclonal antibodies immobilized on 3-aminopropyl-modified MNPs. The total assay time into the microfluidic competitive immunosensor was 16 min, and the calculated detection limit was 0.05 μg kg(-1). Moreover, the intra- and inter-assay coefficients of variation were below 6.5%. The proposed method can be a very promising analytical tool for the determination of OTA in apparently healthy fruits post-harvest and for its application in the agricultural industry.  相似文献   

11.
A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β2-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β2-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL−1, with the detection limits of 0.20 and 0.040 ng mL−1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β2-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.  相似文献   

12.
Wang J  Ren J 《Electrophoresis》2005,26(12):2402-2408
In this paper we have presented a sensitive and rapid immunoassay (IA) method by capillary electrophoresis with an enhanced chemiluminescence detection system (CE-CL) based on the catalytic effects of horseradish peroxidase (HRP) on the luminol-hydrogen peroxide reaction. The conditions for the CL reaction and electrophoresis were systematically investigated using HRP as a model sample. The linear range from 2.5 x 10(-11) to 1.0 x 10(-9) mol/L (R = 0.999), and the detection limit of 1.0 x 10(-12) mol/L (signal-to-noise ratio = 3) for HRP were achieved using para-iodophenol as CL enhancer. The relative standard deviations of the migration time and peak area for 5.0 x 10(-10) mol/L HRP (n = 7) were 0.26 and 4.8%, respectively, using a CE system with a home-built CL detector. Under the optimal condition, the HRP-labeled CA125 antibody (Ab) and the Ab-antigen complex were well separated within 4 min by CE using a high-pH buffer (pH 10.20). The assay was successfully used for quantification of CA125 in human sera from health controls and patients associated with ovarian cancer, and the recoveries of the standard addition experiments were 93-109%. Our primary results demonstrated that IA based on CE-CL detection is a powerful tool for clinical diagnosis combined with these commercial IA kits.  相似文献   

13.
A simple, rapid, and highly sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) and disposable screen-printed electrodes (SPE) has been developed to detect polychlorinated biphenyls (PCBs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PCB-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PCB (HRP-PCB). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreactions among PCB-antibody-coated MBs, PCB analyte, and HRP-PCB. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing o-aminophenol and hydrogen peroxide for electrochemical detection. The different parameters, including the amount of HRP-PCB conjugates, immunoreaction time, and the concentration of substrate that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 10 pg mL−1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical immunoassay was successfully evaluated with untreated river water spiked with PCBs, and the results were validated by commercial PCB enzyme-linked immunosorbent assay kit, indicating that this convenient and sensitive technique offers great promise for decentralized environmental application and trace PCBs monitoring.  相似文献   

14.
Wang G  Yuan J  Hai X  Matsumoto K 《Talanta》2006,70(1):133-138
A sensitive homogeneous time-resolved fluoroimmunoassay method for 3,5,3'-triiodo-l-thyronine (T3) based on the fluorescence resonance energy transfer (FRET) from a fluorescent Eu(3+) complex, {[(4,6-dichloro-1,3,5-triazin-2-yl)amino-biphenyl-4'-yl]-2,2':6',2'-terpyridine-6,6'-diyl}bis(methylenenitrilo) tetrakis(acetate)-Eu(3+) (DTBTA-Eu(3+)) (lambda(ex,max)=335nm, lambda(em,max)=615nm), to an organic fluorescence dye Cy5 has been developed. The new assay system combined the use of DTBTA-Eu(3+)-labeled T3-bovine serum albumin (BSA) conjugate and Cy5-labeled anti-T3 monoclonal antibody for a competitive-type immunoassay. After the competitive reactions of DTBTA-Eu(3+)-labeled T3-BSA and T3 sample with Cy5-labeled anti-T3 antibody, the T3 concentration was measured with a time-resolved mode by monitoring the sensitized emission of Cy5 derived from FRET in a homogeneous format. The method gives the detection limit of 0.26ng/ml. The coefficient variations of the method are less than 2.0% and the recoveries are in the range of 80-111% for serum sample measurement. The concentrations of T3 in 30 human serum samples were determined, and the results were compared with those of the independently determined by a radio-immunoassay method. A good correlation was obtained with a correlation coefficient of 0.989.  相似文献   

15.
An ultrasensitive chemiluminescent (CL) immunoassay system was developed for the detection of tumor marker. This sandwich CL assay method was for the first time designed based on a highly efficient streptavidin-functionalized multi-walled carbon nanotubes (MWCNTs) platform. The glass slide was firstly silylanized with 3-gycidoxypropyltrimethoxysilane (GPTMS) to generate surface epoxy group functionality. Subsequently, the MWCNTs/chitosan solution was mixed with streptavidin solution, and a certain amount of the resulting suspension was dropped on the surface of the epoxy-activated glass substrate to form a firm streptavidin-functionalized MWCNTs platform. The biofunctionalized-MWCNTs platform shows large reactive surface area and excellent biocompatibility. The capture antibody can be efficiently immobilized on the biosensing platform surface based on the highly selective recognition of streptavidin to biotinylated antibody. Using α-fetoprotein (AFP) as model analyte, the proposed method exhibits wide linear range of 0.001–0.1 ng mL−1 with a low detection limit down to 0.52 pg mL−1. The CL immunoassay system displays 7.9-fold increase in the detection sensitivity compared to the immunosensor without using MWCNTs. Moreover, the resulting immunosensor demonstrates excellent specificity, good reproducibility, and acceptable stability. This streptavidin-functionalized MWCNTs platform opens a novel and promising avenue for fabricating ultrasensitive CL immunoassay system.  相似文献   

16.
We report here the development of a new assay for the detection of ochratoxin A (OTA) based on the use of its dechlorinated analogue, ochratoxin B (OTB), in a displacement immunoassay. OTB was immobilised on controlled-pore glass beads followed by the binding of anti-OTA antibody, with anti-IgG antibody peroxidase conjugate used as a label. In this manner, an original bio-sensing material was obtained. Upon incubation of this material with OTA, the toxin competes with OTB for the binding sites of the anti-OTA antibodies and releases the antibody-tagged peroxidase complex into the solution. Compared to classic competitive immunoassays, this newly developed displacement immunoassay presents a similar detection limit and assay time. Moreover, the detection, based on the activity of the horseradish peroxidase, is performed for the first time in situ using wine samples.  相似文献   

17.
A rapid fluorescence polarization (FP) immunoassay has been developed for the simultaneous determination of T-2 and HT-2 toxins in naturally contaminated wheat samples. Syntheses of four fluorescein-labelled T-2 or HT-2 toxin tracers were carried out and their binding response with seven monoclonal antibodies was evaluated. The most sensitive antibody-tracer combination was obtained by using an HT-2-specific antibody and a fluorescein-HT-2 tracer. The developed competitive FP immunoassay in solution showed high cross-reactivity for T-2 toxin (CR% = 100%) while a very low CR% for neosolaniol (0.12%) and no cross-reactivity with other mycotoxins frequently occurring in wheat. A rapid extraction procedure using 90% methanol was applied to wheat samples prior to FP immunoassay. The average recovery from spiked wheat samples (50 to 200 μg kg−1) was 96% with relative standard deviation generally lower than 8%. A limit of detection of 8 μg kg−1 for the combined toxins was determined. Comparative analyses of 45 naturally contaminated and spiked wheat samples by both the FP immunoassay and high-performance liquid chromatography/immunoaffinity clean-up showed a good correlation (r = 0.964). These results, combined with the rapidity (10 min) and simplicity of the assay, show that this method is suitable for high throughput screening as well as for quantitative determination of T-2 and HT-2 toxins in wheat.  相似文献   

18.
An analytical system of immunochromatographic assay based on gold nanoparticles was developed for the detection of 7-aminoclonazepam (7-ACLZ) in human urine. The qualitative assay was based on the competitive immunoassay using anti-7-ACLZ polyclonal antibody (PcAb) and a detector reagent that contains colloidal gold particles coated with anti-7-ACLZ PcAb. Nitrocellulose membrane was separately immobilised with goat anti-rabbit IgG (control line) and 7-ACLZ-OVA conjugate (test line). The sensitivity of the strip was tested for detecting 7-ACLZ spiked in urine and each specimen was independently measured by liquid chromatography tandem mass spectrometry. Good correlation was showed by the recovery results. The limit of detection for the strip test in urine was 100 ng mL?1. The assay can be applied to the rapid detection of 7-ACLZ with the short testing time.  相似文献   

19.
Roda A  Manetta AC  Piazza F  Simoni P  Lelli R 《Talanta》2000,52(2):311-318
A fast and sensitive chemiluminescent (CL) enzyme immunoassay for clenbuterol (CLB) analysis in bovine urine has been developed. Clenbuterol (CLB) specific polyclonal antibodies were raised in rabbit using a CLB azo derivative conjugated with ovalbumin. Horseradish peroxidase (HRP) was used as label and conjugated with the same derivative. In the developed competitive method, antibodies were immobilized on 384-wells black polystyrene microtiter plates; the sample volume was 20 mul and HRP-labeled CLB activity was immediately measured, using different CL substrates, after 10 min incubation time. Emitted light was recorded using a sensitive back-illuminated, cooled CCD camera or a conventional, photomultiplier-based micrtotiter plate reader. The developed method fulfills all the requirements of precision (CV below 10%) and accuracy (mean recovery from 96 to 110%) with a detection limit of 0.08 ppb in urine matrix. The use of 384-wells microtiter plate allows a 5-fold reduction in reagent quantity and the CL detection improves the detectability of the HRP-labeled tracer, thus reducing analysis time. The developed method is therefore suitable for high-throughput screening of CLB in urine samples, with reduced costs as compared with conventional colorimetric enzyme immunoassays, thanks to the possibility to optimize the system in non-equilibrium immunological conditions and with a very fast chemiluminescence detection of the HRP-label activity.  相似文献   

20.
We have developed a competitive enzyme immunoassay for a drug, which was a newly synthesized anti-ulcer agent, using an enzyme immunoassay. The polyclonal anti-drug antibody coupled to biotin, peroxidase labeled drug derivatives as a tracer, and a small column of Sepharose 4B covalently bound to avidin were used in the assay. This assay is simple and rapid, and the sensitivity and the measuring range can be controlled by the flow rate of the substrate solution. The correlation between serum drug concentrations (0.1-10 micrograms/ml) measured by gas chromatography and this assay was good (r = 0.991). This principle for the assay is very practical and applicable to the enzyme immunoassay for small and large molecules.  相似文献   