首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
采用免疫亲和分离与质谱分析相结合的方法, 对β2-微球蛋白抗原表位进行了系统研究. 完整的抗原分子和已固定在载体(CNBr-activated Sepharose beads)上的单克隆抗体发生免疫亲和反应后, 用Endoproteinase Glu-C, Trypsin, Aminopeptidase M和carboxypeptidase Y四种不同的蛋白酶依次酶解抗原分子, 并采用基质辅助激光解析电离飞行时间质谱(MALDI-TOF-MS)技术对与抗体连接受保护而未发生水解的肽段进行了研究. 结果表明: β2-微球蛋白抗原表位位于整个蛋白分子氨基酸序列的61~67位, 即为SFYLLYY. 通过合成肽段的分析, 证明了SFYLLYY即为抗原表位, 与亲和质谱方法分析结果一致.  相似文献   

2.
For structural studies of proteins and their complexes, chemical cross-linking combined with mass spectrometry presents a promising strategy to obtain structural data of protein interfaces from low quantities of proteins within a short time. We explore the use of isotope-labeled cross-linkers in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for a more efficient identification of cross-linker containing species. For our studies, we chose the calcium-independent complex between calmodulin and a 25-amino acid peptide from the C-terminal region of adenylyl cyclase 8 containing an "IQ-like motif." Cross-linking reactions between calmodulin and the peptide were performed in the absence of calcium using the amine-reactive, isotope-labeled (d0 and d4) cross-linkers BS3 (bis[sulfosuccinimidyl]suberate) and BS2G (bis[sulfosuccinimidyl]glutarate). Tryptic in-gel digestion of excised gel bands from covalently cross-linked complexes resulted in complicated peptide mixtures, which were analyzed by nano-HPLC/nano-ESI-FTICR mass spectrometry. In cases where more than one reactive functional group, e.g., amine groups of lysine residues, is present in a sequence stretch, MS/MS analysis is a prerequisite for unambiguously identifying the modified residues. MS/MS experiments revealed two lysine residues in the central alpha-helix of calmodulin as well as three lysine residues both in the C-terminal and N-terminal lobes of calmodulin to be cross-linked with one single lysine residue of the adenylyl cyclase 8 peptide. Further cross-linking studies will have to be conducted to propose a structural model for the calmodulin/peptide complex, which is formed in the absence of calcium. The combination of using isotope-labeled cross-linkers, determining the accurate mass of intact cross-linked products, and verifying the amino acid sequences of cross-linked species by MS/MS presents a convenient approach that offers the perspective to obtain structural data of protein assemblies within a few days.  相似文献   

3.
蛋白质主要以复合物的形式参与各项生命活动.化学交联质谱(CXMS)技术作为近年来新兴的蛋白质复合物解析技术,不仅可实现蛋白质复合物规模化解析,而且普遍适用于任意相对分子质量和纯度的蛋白质复合物样品,因此已成为X-射线晶体衍射技术、冷冻电镜技术等蛋白质复合物解析经典技术的重要补充.目前,CXMS主要采用胰蛋白酶将交联后的...  相似文献   

4.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

5.
The use of a bis(terpyridine)ruthenium(ii) complex for peptide labeling (Ru-CO labeling) supplied high intensity peaks in mass spectrometry (MS) analysis that overcame the contribution of protonation or sodiated adduction to peptides. Ru-CO-labeled insulin A- and B-chains were detected simultaneously in comparable peak abundance by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The mass spectra of chymotryptic peptide fragments of Ru-CO-labeled insulin also simultaneously indicated both N-terminal fragment ions, and amino acid sequences were determined easily by matrix-assisted laser desorption/ionization post-source-decay (MALDI-PSD). The sensitivity of detecting Ru-CO-labeled peptide fragment ions was not dependent on the length or the sequences of the peptides. The Ru-CO labeling method was applied to tryptic myoglobin fragments. The method indicated that each fragment ion is detected nearly equal in abundance and enabled the desired fragment ions to be distinguished from matrix clusters or their in-source fragments in lower mass regions. The desired fragment ions can be found in the mass region higher than 670.70 (= Ru-CO). This method provided a high sequence coverage (96%) by peptide mass fingerprinting (PMF). Application of this method to a protein mixture (myoglobin, lysozyme and ubiquitin) successfully achieved high sequence-coverage characterization (>90%) of these proteins simultaneously.  相似文献   

6.
《Analytical letters》2012,45(12):2124-2137
Papain was purified from dried Carica papaya latex by fractioned salt precipitation in presence of sodium tetrathionate to preserve enzymatic activity. Purification was followed by different electrophoretic methods. Identification of the purified product was afforded by submitting the peptides obtained by tryptic digestion of papain to matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF/TOF MS) analysis. Comparison of the peptide masses analyzed by peptide mass fingerprinting (PMF) MALDI-TOF and those obtained by theoretical tryptic digestion, revealed the presence of some peptides belonging the other three endopeptidases contained in papaya latex (very similar to papain in molecular weight and pI) in the purified fraction of papain. The PMF by MALDI-TOF could be applied as a method to follow papain purification.  相似文献   

7.
Our previous work has demonstrated that reversed-phase chromatographic micro-beads can be used to capture proteins from complex biological matrices and the surface-bound proteins can be enzymatically digested for protein identification by mass spectrometry (MS). Here we examine the peptides generated from digestion of proteins bound to various types of micro-bead surfaces in order to determine the effects of surface chemistry and surface morphology on the digestion process. Detailed examinations of site cleavages and sequence coverage are carried out for a tryptic digestion of cytochrome c adsorbed on reversed-phase polystyrene divinylbenzene (Poros R2 beads) versus C(18) bonded-phase silica beads. It is shown that although the surface does not completely hinder the digestion of cleavage sites of the protein, the digestion products are clearly different than those obtained from a solution digest. Specifically, a partial digestion results from surface digestion, resulting in a greater number of missed cleavages than a comparable solution digest. Subsequent comparisons of peptide mass maps generated from the digestion of various proteins on surfaces with altering chemistry (C(4), C(8), C(18), and R2 beads), or with different surface morphology, were performed. The results reveal that surface chemistry plays only a minor role in affecting the peptide mass maps, and surface morphology had no noticeable effects on the resulting peptide mass maps. It is also shown that the mass spectrometric detection method used to analyze the digested peptides can significantly influence the information content on cleavage sites and the extent of sequence coverage. The use of a combination of MALDI, LC/off-line MALDI, and LC/ESI MS is demonstrated to be crucial in revealing subtle changes in the peptide mass maps.  相似文献   

8.
Condensed phase protein sequencing typically relies on N-terminal labeling with phenylisothiocyanate ("Edman" reagent), followed by cleavage of the N-terminal amino acid. Similar Edman degradation has been observed in the gas phase by collision-activated dissociation of the N-terminal phenyl thiocarbamoyl protonated peptide [1] to yield complementary b1 and y(n-1) fragments, identifying the N-terminal amino acid. By use of infrared multiphoton (rather than collisional) activation, and Fourier transform ion cyclotron resonance (rather than quadrupole) mass analysis, we extend the method to direct analysis of a mixture of tryptic peptides. We validate the approach with bradykinin as a test peptide, and go on to analyze a mixture of 25 peptides produced by tryptic digestion of apomyoglobin. A b1+ ion is observed for three of the Edman-derivatized peptides, thereby identifying their N-terminal amino-acids. Search of the SWISS-PROT database gave a single hit (myoglobin, from the correct biological species), based on accurate-mass FT-ICR MS for as few as one Edman-derivatized tryptic peptide. The method is robust-it succeeds even with partial tryptic digestion, partial Edman derivatization, and partial MS/MS IRMPD cleavage. Improved efficiency and automation should be straightforward.  相似文献   

9.
Vitellogenin (VTG) is a protein produced by the liver of oviparous animals in response to circulating estrogens. In the plasma of males and immature females, VTG is undetectable. VTG has been used as a biomarker for exposure to endocrine disruptors in many species. In the present study, characterization of intact Atlantic salmon VTG was effected using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI ToF MS). Tryptic digest peptides were analyzed by MALDI ToF MS to obtain a peptide mass fingerprint. De novo sequencing of the tryptic peptides used low-energy collisionally-induced dissociation (CID) in an electrospray ionization quadrupole-ToF orthogonal hybrid mass spectrometer (ESI Q-ToF MS/MS). The interpretation of the product-ion spectra obtained from the ESI Q-ToF MS/MS was done by Lutefisk, a computer-based software algorithm. The molecular mass of the intact protein was found to be 187335 Da. A total of 14 tryptic peptides were sequenced and compared with the complete rainbow trout VTG and the partial Atlantic salmon VTG sequences found in the Swiss-Prot database. De novo sequencing by CID MS/MS of 11 Atlantic salmon tryptic digest peptides with selected precursor ions at m/z 788.24, 700.20, 794.75, 834.31, 889.28, 819.79, 865.27, 843.81, 572.20, 573.66 and 561.68 showed high homology with the known sequence of rainbow trout VTG. The last two precursor peptide ions, found at m/z 573.66 and m/z 561.68, also specifically matched the known portion of the Atlantic salmon VTG sequence. Finally, three tryptic precursor peptide ions found at m/z 795.18, 893.28 and 791.05, provided product-ion spectra, which were exclusive to the unsequenced portion of the Atlantic salmon VTG.  相似文献   

10.
We report a fast and easy-to-use procedure that combines polyacrylamide gel electrophoresis with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF) and nanoelectrospray-tandem mass spectrometry (nES-MS/MS) analysis for the identification of casein components and defined phosphorylated sites. This methodology ensured identification of more than 30 phosphorylated proteins, five beta-, fifteen alpha(s1)-, ten alpha(s2)-, and four kappa-casein (CN) components, including nonallelic, differently phosphorylated, and glycosylated forms. The sugar motif covalently bound to kappa-CN was identified as chains, trisaccharide GalNAc, Gal, NeuGc, and tetrasaccharide 1GalNAc, 1Gal, 2NeuGc. Also identified was a biantennary chain made up of both chains of trisaccharide 1GalNAc, 1Gal, 1NeuGc, and tetrasaccharide 1GalNAc, 1Gal, 2NeuGc moiety on a single kappa-CN component. The phosphate group on site Ser12 of tryptic peptide 8-22 of most phosphorylated alpha(s1)-CN (11 phosphate groups) was localized and the oligosaccharide sequence of the main tryptic glycopeptides of two kappa-CN components was determined by means of MS/MS analysis.  相似文献   

11.
We report the application of nanoelectrospray ionization tandem mass spectrometry (nES-MS/MS) and capillary LC/microelectrospray MS/MS (cLC/&mgr;ES-MS/MS) for sequencing sulfonic acid derivatized tryptic peptides. These derivatives were specifically prepared to facilitate low-energy charge-site-initiated fragmentation of C-terminal arginine-containing peptides, and to enhance the selective detection of a single series of y-type fragment ions. Both singly and doubly protonated peptides were analyzed by MS/MS and the results were compared with those from their derivatized counterparts. Model peptides and peptides from tryptic digests of gel-isolated proteins were analyzed. Derivatized singly protonated peptides fragment in the same way by nES-MS/MS as they do by post-source decay matrix-assisted laser desorption/ionization mass spectrometry (PSD-MALDI-MS). They produce fragment ion spectra dominated by y-ions, and the simplified spectra are readily interpreted de novo. Doubly protonated peptides fragment in much the same way as their non-derivatized doubly protonated counterparts. The fragmentation of doubly protonated derivatives is especially useful for sequencing peptides that possess a proline residue near the N-terminus of the molecule. The singly protonated forms of these proline-containing derivatives often show enhanced fragmentation on the N-terminal side of the proline and considerably reduced fragmentation on the C-terminal side. In addition, sulfonic acid derivatization increases the in-source fragmentation of arginine-containing peptides. This could be useful for sequence verification and sequence tagging for use in single stage mass spectrometry. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

12.
Liquid chromatography/mass spectrometry (LC/MS) peptide maps have become a basic tool for characterizing proteins of biological and pharmaceutical interest. The ability to generate reproducible maps with high protein sequence coverage is a central goal of methods development. We have applied a recently developed analytical approach (termed LC/MS(E)) to LC/MS peptide mapping. Using the LC/MS(E) approach, the mass detector alternates between a low-energy scanning mode (MS) for accurate mass peptide precursor identification, and an elevated-energy mode (MS(E)) for generation of accurate mass multiplex peptide fragmentation data. In this paper, we evaluate this analytical approach against a tryptic digest of yeast enolase. From the low-energy data, high peptide map coverage (98% of sequence from peptides >3 amino acids) was reproducibly obtained. The MS signal for essentially equimolar peptides varied over 2 orders of magnitude in intensity, and peptide intensities could be precisely and reproducibly measured. Using the temporal constraint that MS(E) peptide fragment ions exhibit chromatographic profiles that parallel the precursor ions that generated them, we were able to produce accurate mass time-resolved MS/MS information for all enolase peptides with sufficient abundance to produce a detectable fragment ion.  相似文献   

13.
Mass spectral analysis of tryptic digests of cross-linked proteins offers considerable promise as a simple technique to probe protein structure and study protein-protein interactions. We describe the use of a 1:1 mixture of isotopically labeled and unlabeled cross-linkers, disuccinimidyladipate (DSA) and dimethyladipimidate (DMA), to enhance visualization of cross-linked peptides in a tryptic digest. Optimized intramolecular reactions of cytochrome c and ribonuclease A (RNase A) with DSA yielded an average of two cross-links per protein molecule. After digestion of the cross-linked cytochrome c with trypsin and analysis by liquid chromatography/mass spectrometry (LC/MS) and matrix-assisted laser desorption/ionization (MALDI), eight modified peptides, five cross-linked and two end-capped, were detected by virtue of their doublet character. An eighth modified peptide's identity remained ambiguous because of its inability to fragment. The lysine-lysine distance constraints obtained are discussed in the context of the known NMR and X-ray structures of cytochrome c. Analysis of cross-linked RNase A by LC/MS and MALDI yielded nine modified peptides, four of which were modified twice, as indicated by the isotopic triplets. Although seven of these peptides contained cross-links, few distance constraints were gained due to the fact that the cross-linked products were variations of modification of the same three lysine residues.  相似文献   

14.
A simple and inexpensive nano high performance liquid chromatography system (nano-LC) employing the exponential dilution method for gradient separations was built. The system was used to analyze a tryptic digest of Escherichia coli uracil DNA glycosylase (Ung; Mr = 25,563), a DNA-binding protein that initiates the uracil-excision DNA repair process by catalyzing the release of uracil from the deoxyribose phosphate backbone of DNA. Both on-line and off-line approaches to analyzing peptides produced by in-gel digestion of Ung are demonstrated. The on-line approach uses nano-high performance liquid chromatography (HPLC)/micro-electrospray MS to assign peptide masses. The off-line approach uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and nano-electrospray/collision-induced dissociation (CID) tandem mass spectrometry, to analyze fractions (2-3 microL) collected manually from the nano-LC system. The nano-electrospray technique allows detailed fragmentation information to be obtained at different collision energies with only a marginal increase in sample handling due to the nano-LC step.  相似文献   

15.
Bioactive peptides and tryptic digests of various proteins were separated under acidic and alkaline conditions by ion-pair-reversed-phase high-performance liquid chromatography (RP-HPIPC) in 200 microm I.D. monolithic, poly(styrene-divinylbenzene)-based capillary columns using gradients of acetonitrile in 0.050% aqueous trifluoroacetic acid, pH 2.1, or 1.0% triethylamine-acetic acid, pH 10.6. Chromatographic performances with mobile phases of low and high-pH were practically equivalent and facilitated the separation of more than 50 tryptic peptides of bovine serum albumin within 15-20 min with peak widths at half height between 4 and 10 s. Neither a significant change in retentivity nor efficiency of the monolithic column was observed during 17-day operation at pH 10.6 and 50 degrees C. Upon separation by RP-HPIPC at high-pH, peptide detectabilities in full-scan negative-ion electrospray ionization mass spectrometry (negESI-MS) were about two to three times lower as compared to RP-HPIPC at low-pH with posESI-MS detection. Tandem mass spectra obtained by fragmentation of deprotonated peptide ions in negative ion mode yielded interpretable sequence information only in a few cases of relatively short peptides. However, in order to obtain sequence information for peptides separated with alkaline mobile phases, tandem mass spectrometry (MS/MS) could be performed in positive ion mode. The chromatographic selectivities were significantly different in separations performed with acidic and alkaline eluents, which facilitated the fractionation of a complex peptide mixture obtained by the tryptic digestion of 10 proteins utilizing off-line, two-dimensional RP-HPIPC at high pH x RP-HPIPC at low pH and subsequent on-line identification by posESI-MS/MS.  相似文献   

16.
In this study, we explored the MS/MS behavior of various synthetic peptides that possess a lysine residue at the N-terminal position. These peptides were designed to mimic peptides produced upon proteolysis by the Lys-N enzyme, a metalloendopeptidase issued from a Japanese fungus Grifola frondosa that was recently investigated in proteomic studies as an alternative to trypsin digestion, as a specific cleavage at the amide X-Lys chain is obtained that provides N-terminal lysine peptide fragments. In contrast to tryptic peptides exhibiting a lysine or arginine residue solely at the C-terminal position, and are thus devoid of such basic amino acids within the sequence, these Lys-N proteolytic peptides can contain the highly basic arginine residue anywhere within the peptide chain. The fragmentation patterns of such sequences with the ESI-QqTOF and MALDI-TOF/TOF mass spectrometers commonly used in proteomic bottom-up experiments were investigated.  相似文献   

17.
We describe the application of immunoaffinity extraction and mass spectrometry to the analysis of Ty1 Gag protein in lysates of Saccharomyces cerevisiae. A magnetic bead-conjugated monoclonal antibody was used to achieve selective extraction, the specificity of which was established by matrix-assisted laser desorption/ionization mass spectrometric (MS) analysis of an extract of the lysate of cells overexpressing the Ty1 Gag protein. MS analysis of similar extracts of lysates following tryptic hydrolysis confirmed selective extraction of the epitope-containing peptide fragment. Sufficient sensitivity was achieved to allow the application of this approach to the analysis of lysates of wild-type cells. Furthermore, the sequence of the epitope-containing peptide was confirmed by electrospray-tandem MS. To our knowledge, this constitutes the first report of the application of immunoaffinity extraction and tandem MS analysis to the characterization of an antigen recovered from a complex cellular system.  相似文献   

18.
The extent and effects of sequence scrambling in peptide ions during tandem mass spectrometry (MS/MS) have been examined using tryptic peptides from model proteins. Sequencescrambled b ions appeared in about 35% of 43 tryptic peptides examined under MS/MS conditions. In general, these ions had relatively low abundances with averages of 8% and 16%, depending on the instrumentation used. A few tryptic peptides gave abundant scrambled b ions in MS/MS. However, peptide and protein identifications under proteomic conditions with Mascot were not affected, even for these peptides wherein scrambling was prominent. From the 43 tryptic peptides that have been investigated, the conclusion is that sequence scrambling is unlikely to impact negatively on the accuracy of automated peptide and protein identifications in proteomics.  相似文献   

19.
20.
P-Glycoprotein (P-gp/ABCB1) is expressed in membrane barriers to exclude pharmacological substrates from cells, and therefore influences the ADME/Tox properties and efficacy of therapeutics. In the present study, a liquid chromatography/tandem mass spectrometry (LC/MS/MS)-mediated targeted proteomics was developed to quantitate P-gp protein. With the aid of in silico predictive tools, a unique 9-mer tryptic peptide of P-gp protein was synthesized (with the stable isotope labeled (SIL) peptide as internal standard) and applied for quantitative LC/MS/MS method development. For LC/MS/MS quantification, the N-glycosylation of the peptide, polymorphism and transmembrane region was intended to be excluded during the peptide selection. The lower limit of quantification was established to be 0.025 nM with the linearity of the standard curve ranging to 20 nM of P-gp signature peptides in the matrix digested surrogate bovine serum albumin. The digestion efficiency, both the accuracy (relative error) and the precision (coefficient of variation) of the method, was verified by using the synthetic quantification peptide and the synthetic surrogate substrate peptide that mimics the sequence of tryptic peptide and associated flanking tryptic cleavage sites at the N- and C-terminals. By applying the method developed, the absolute amounts of human, dog and mouse P-gp (Mdr1a) were quantified in various biological samples. LC/MS/MS-mediated P-gp quantification was achieved as a highly sensitive, selective and reproducible assay and could be directly applicable to many current research needs related to P-gp.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号