首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liu Y  Chen W  Liu J  Shi S 《Ultrasonics》2011,51(5):527-531
A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transducer and have a distance that equal to the half wave length of bending standing wave excited in the cylinder. Thus, the bending mode of the cylinder can be excited by the bending vibration of the transducer. Two circular cone type rotors are pressed in contact to the end rims of the teeth, and the preload between the rotors and stator is accomplished by a spring and nut system. The working principle of the proposed motor was analyzed. The motion trajectories of teeth were deduced. The stator was designed and analyzed with FEM. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 165 rpm and maximum torque of 0.45 N m at an exciting voltage of 200 Vrms.  相似文献   

2.
Holwill IL 《Ultrasonics》2000,38(1-8):650-653
Fluid dynamics modelling augmented with routines to simulate acoustic forces on aerosol particles has been used to investigate the potential of combining ultrasonic standing wave fields with optical particle analysis equipment. Simulations of particle dynamics in airstreams incorporating acoustic forces predict that particles in the 1-10 microns diameter range may be effectively focused to the velocity nodes of the standing wave field. Particles move to the velocity nodes within tens of milliseconds for acoustic frequencies of 10-100 kHz and at an acoustic energy density of 100 Jm-3. Larger particles are predicted to move to the velocity antinodes within similar times; however, there is a crossover region at approximately 15-20 microns particle diameter where longer times are predicted due to the competing forces driving particles to the vibration node and antinode. With sufficient transverse flow velocities the models predict that disturbances due to acoustic streaming can be overcome and a useful degree of focusing achieved for the aerosol particles. Results from a model demonstrating sampling and acoustic focusing of 3-9 microns aerosol particles to a 200 microns wide analysis area are presented.  相似文献   

3.
Acoustic radiation forces offer a means of manipulating particles within a fluid. Much interest in recent years has focussed on the use of radiation forces in microfluidic (or “lab on a chip”) devices. Such devices are well matched to the use of ultrasonic standing waves in which the resonant dimensions of the chamber are smaller than the ultrasonic wavelength in use. However, such devices have typically been limited to moving particles to one or two predetermined planes, whose positions are determined by acoustic pressure nodes/anti-nodes set up in the ultrasonic standing wave. In most cases devices have been designed to move particles to either the centre or (more recently) the side of a flow channel using ultrasonic frequencies that produce a half or quarter wavelength over the channel, respectively.It is demonstrated here that by rapidly switching back and forth between half and quarter wavelength frequencies - mode-switching - a new agglomeration position is established that permits beads to be brought to any arbitrary point between the half and quarter-wave nodes. This new agglomeration position is effectively a position of stable equilibrium. This has many potential applications, particularly in cell sorting and manipulation. It should also enable precise control of agglomeration position to be maintained regardless of manufacturing tolerances, temperature variations, fluid medium characteristics and particle concentration.  相似文献   

4.
This paper introduces a novel method for designing the transducer of a highly directional ultrasonic range sensor for detecting obstacles in mobile robot applications. The transducer consists of wave generation, amplification, and radiation sections, and a countermass. The operating principle of this design is based on the parametric array method where the frequency difference between two ultrasonic waves is used to generate a highly directional low-frequency wave with a small aperture. The aim of this study was to design an optimal transducer to generate the two simultaneous longitudinal modes efficiently. We first derived an appropriate mathematical model by combining the continuum model of a bar and countermass with the compatibility condition between a piezoelectric actuator and a linear horn. Then we determined the optimal length of the aluminum horn and the piezoelectric actuator using a finite element method. The proposed sensor exhibited a half-power bandwidth of less than ±1.3° at 44.8 kHz, a much higher directivity than existing conventional ultrasonic range sensors.  相似文献   

5.
The presented investigations aimed to enhance surface sensitive infrared spectroscopy for chemical analysis by ultrasonic particle manipulation. The combination of these techniques has the potential for new measurement concepts for use in the chemical analysis of suspensions. Local increases of particle concentration brought about by ultrasound could facilitate measurements of molecular-specific infrared spectra of the suspending phase and particles independently. By changing the frequency of an ultrasonic standing wave around 2 MHz it was possible to control the position of particles in respect to the optically sensitive region of the infrared spectroscope.Results obtained with a set-up that enabled us to explore the application of an ultrasonic standing wave to push suspended particles at or into μm distances of the sensing element of an in-line fiber optic probe and subsequently retract them from there are presented. Light micrographs suggested, that the task was successfully accomplished with polystyrene beads suspended in methanol, aggregates were manipulated to and from the cut surface of the truncated, cone-shaped fibre probe tip by changes of the ultrasonic frequency between 1.85 and 1.87 MHz. Feasibility was confirmed by infrared absorption spectra recorded when PTFE particles suspended in tetrahydrofuran were used.  相似文献   

6.
Slurry erosion has been recognized as a serious problem in many industrial applications. In slurry flows, the estimation of the amount of incident kinetic energy that transmits from particles suspended in the fluid to the containment structures is a key aspect in evaluating its abrasive potential. This work represents a systematic investigation of particle impact energy measurement using acoustic emission (AE), as indicated by a sensor mounted on the outer surface of a sharp bend, in an arrangement that had been pre-calibrated using controlled single and multiple impacts. Particle size, free stream velocity, and nominal particle concentration were varied, and the amount of energy dissipated in the carbon steel bend was assessed using a slurry impingement flow loop test rig. Silica sand particles of mean particle size 225–650 μm were used for impingement on the bend with particle nominal concentrations between 1 and 5% while the free stream velocity was changed between 4.2 and 14 ms−1.  相似文献   

7.
A theoretical model was suggested for qualitative evaluation of a sound pressure field in fruit tissue, as affected by ultrasonic probe dimensions and fruit properties. The classic directivity pattern of an ideal fluid model, expressed by Bessel function of the first kind, was extended to include energy dissipation of a real material. The directional characteristics of wave propagation, as influenced by transmitter frequency and diameter, and by fruit properties, were discussed. The model indicates how to select the parameters of the ultrasonic transducer (transducer diameter, frequency and excitation power) to control the magnitude and directivity of the ultrasonic waves in the fruit tissue. The suggested theoretical model represented fairly well the experimental sound wave distribution over the half-cut surface of potato and avocado (R2 > 0.862 and 0.977, respectively); the same theoretical model could not represent the sound wave distribution over a half-cut melon. Results of the study were applied in a new probe design for ultrasonic testing of whole fruit.  相似文献   

8.
The slow compressional wave in air-saturated aluminum foams was studied by means of ultrasonic transverse transmission method over a frequency range from 0.2 MHz to 0.8 MHz. The samples investigated have three different cell sizes or pores per inch (5, 10 and 20 ppi) and each size has three aluminum volume fractions (5%, 8% and 12% AVF). Phase velocities show minor dispersion at low frequencies but remain constant after 0.7 MHz. Pulse broadening and amplitude attenuation are obvious and increase with increasing ppi. Attenuation increases considerably with AVF for 20 ppi foams. Tortuosity ranges from 1.003 to 1.032 and increases with AVF and ppi. However, the increase of tortuosity with AVF is very small for 10 and 20 ppi samples.  相似文献   

9.
An implementation of a quarter-wavelength standing wave separator that exploits an air drum to achieve the pressure node is presented and characterized experimentally. The air drum configuration was implemented and tested in a set-up with a 40 kHz transducer immersed in a water tank with the quarter-wavelength gap being approximately 9 mm wide. Injection of suspensions of 5 μm and 45 μm diameter polystyrene particles at flow rates of 30 ml/h and 60 ml/h was studied and particle deflection towards the pressure node at the air drum surface was observed for a range of acoustic pressures. Computational results on single particle trajectories show good agreement with the experimental findings for the 45 μm particles, but not for the 5 μm particles. These were considered to behave as aggregates of higher effective dimension, due to their much higher number density relative to the 45 μm particles in the suspensions used. The set-up developed in this study includes a robust method for achieving a pressure node in a quarter-wavelength system and can represent the first step toward the development of an alternative separator configuration in respect to small channel MHz range operated systems for the manipulation of particles streams.  相似文献   

10.
The flow simulation for GaxIn1−xSb and Si melts was conducted for quasi-steady conditions. The maximum velocity was under the solid–liquid interface near periphery of the crystals. An introduction of ultrasound into the liquid formed a standing wave channel under the solid–liquid interface, which acted on melt particles. The calculations of convective and ultrasonic forces acting on the particles in the melt showed that the ultrasonic force is much higher than the convective force.  相似文献   

11.
A method of manipulating microparticles in a liquid using ultrasound is proposed and demonstrated. An ultrasonic standing wave with nodal planes whose positions are controllable by varying the relative phase of two applied sinusoidal signals is generated using a pair of acoustically matched piezoelectric transducers. The resulting acoustic radiation force is used to trap micron scale particles at a series of arbitrary positions (determined by the relative phase) and then move them in a controlled manner. This method is demonstrated experimentally and 5 μm polystyrene particles are trapped and moved in one dimension through 140 μm.  相似文献   

12.
Bálek R  Pekárek S  Bartáková Z 《Ultrasonics》2006,44(Z1):e549-e553
The effect of power ultrasound application on DC hollow needle to plate atmospheric pressure electrical discharge enhanced by the flow of air through the needle electrode was studied experimentally. It was found that applying ultrasound increases discharge volume. In this volume take place plasmachemical processes, used in important ecological applications such as the production of ozone, VOC decomposition and de-NOx processes enhancement. In our experiments we used a negatively biased needle electrode as a cathode and a perpendicularly placed surface of the ultrasonic resonator--horn--as an anode. To demonstrate the effect of ultrasound waves on electrical discharge photographs of the discharge for the needle to the ultrasonic resonator at distances of 4, 6 and 8mm are shown. By varying the distance between needle and the surface of the transducer, we were able to create the node or the antinode at the region around the tip of the needle, where the ionization processes are effective. In our experimental arrangement the amplitude of acoustic pressure at antinode exceeded 10(4) Pa. The photographs reveal that the diameter of the discharge on the surface of the ultrasonic horn is increased when ultrasound is applied. The increase of discharge volume caused by the application of ultrasound can be explained as a combined effect of the change of the reduced electric field E/n (E is electric field strength and n is the neutral particles density), strong turbulence of the particles in the discharge region caused by quick changes of amplitudes of the standing ultrasonic wave and finally by the boundary layer near the ultrasonic transducer perturbations due to vibrations of the transducer surface.  相似文献   

13.
The phenomenon of light diffraction by a cylindrical ultrasonic wave has been investigated. The diffraction was applied in a new type of acousto-optic modulator used for laser mode locking. The paper describes the modulator and presents results on mode locking of argon ion laser. The mode locking was obtained by means of a cylindrical acoustic wave launched in water at the frequencies of ultrasound 33-34 MHz. A standing wave regime of operation of the modulator resulted in a reliable generation of laser pulses with the duration 720 ps.  相似文献   

14.
Townsend RJ  Hill M  Harris NR  White NM 《Ultrasonics》2006,44(Z1):e467-e471
Within an acoustic standing wave particles experience acoustic radiation forces, a phenomenon which is exploited in particle or cell manipulation devices. When developing such devices, one-dimensional acoustic characteristics corresponding to the transducer(s) are typically of most importance and determine the primary radiation forces acting on the particles. However, radiation forces have also been observed to act in the lateral direction, perpendicular to the primary radiation force, forming striated patterns. These lateral forces are due to lateral variations in the acoustic field influenced by the geometry and materials used in the resonator. The ability to control them would present an advantage where their effect is either detrimental or beneficial to the particle manipulation process. The two-dimensional characteristics of an ultrasonic separator device have been modelled within a finite element analysis (FEA) package. The fluid chamber of the device, within which the standing wave is produced, has a width to height ratio of approximately 30:1 and it is across the height that a half-wavelength standing wave is produced to control particle movement. Two-dimensional modal analyses have calculated resonant frequencies which agree well with both the one-dimensional modelling of the device and experimentally measured frequencies. However, these two-dimensional analyses also reveal that these modes exhibit distinctive periodic variations in the acoustic pressure field across the width of the fluid chamber. Such variations lead to lateral radiation forces forming particle bands (striations) and are indicative of enclosure modes. The striation spacings predicted by the FEA simulations for several modes compare well with those measured experimentally for the ultrasonic particle separator device. It is also shown that device geometry and materials control enclosure modes and therefore the strength and characteristics of lateral radiation forces, suggesting the potential use of FEA in designing for the control of enclosure modes in similar particle manipulator devices.  相似文献   

15.
Row–column addressed arrays for ultrasonic non-destructive testing (NDT) applications are analyzed and demonstrated in this paper. Simulation and experimental results of a row–column addressed 32 by 32 capacitive micromachined ultrasonic transducer (CMUT) array are presented. The CMUT array, which was designed for medical imaging applications, has a center frequency of 5.3 MHz. The CMUT array was used to perform C-scans on test objects with holes that have diameters of 1.0 mm and 0.5 mm. The array transducer has an aperture size of 4.8 mm by 4.8 mm, and it was used to scan an area of 4.0 mm by 4.0 mm. Compared to an N by N fully addressed 2-D array, a row–column addressed array of the same number of elements requires fewer (N instead of N2) pairs of interconnection and supporting electronic components such as pulsers and amplifiers. Even though the resulting field of view is limit by the aperture size, row–column addressed arrays and the row–column addressing scheme can be an alternative option of 2-D arrays for NDT applications.  相似文献   

16.
Air-coupled ultrasound stimulated optical vibrometry is proposed to generate and detect the resonances of a rubber tube in air. Amplitude-modulated (AM) focused ultrasound radiation force from a broadband air-coupled ultrasound transducer with center frequency of 500 kHz is used to generate a low frequency vibration in the tube. The resonances of several modes of the tube are measured with a laser vibrometer of 633 nm wavelength. A wave propagation approach is used to calculate the resonances of the tube from its known material properties. Theoretical and experimental resonance frequencies agree within 5%. This method may be useful in measuring the in vitro elastic properties of arteries from the resonance measurements in air. It may also be helpful to better understand the coupling effects of the surrounding tissue and interior blood on the vessel wall by measuring the resonance of the vessel in vitro and in vivo.  相似文献   

17.
Electroplated nickel dispersion films with incorporated hard particles, primarily titanium oxide, were studied. A sufficient dispersion of nanometre-scaled particles in Watts solution was reached by application of ultrasonic energy to the galvanic bath. Crystal morphology, mean grain size and formation of textures were examined by electron backscattering diffraction (EBSD), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The typical columnar structure of pure Ni films was refined by means of ultrasound. Incorporation of micron-sized TiO2 particles generates additional nucleation surfaces in contrast to SiC particles. Textures of the subsequent columnar nickel crystals change from 〈2 1 1〉 (silent condition) or 〈1 1 0〉 (ultrasonic condition) fibre textures in growth direction to 〈1 0 0〉 and 〈1 1 1〉 textures under the influence of nanoparticle incorporation. Moreover, nanoparticles remarkably decrease the grain size and grain aspect ratio. Their incorporation takes place inside the crystals as well as between grains.  相似文献   

18.
The axial and transverse radiation forces on a fluid sphere placed arbitrarily in the acoustical field of Bessel beams of standing waves are evaluated. The three-dimensional components of the time-averaged force are expressed in terms of the beam-shape coefficients of the incident field and the scattering coefficients of the fluid sphere using a partial-wave expansion (PWE) method. Examples are chosen for which the standing wave field is composed of either a zero-order (non-vortex) Bessel beam, or a first-order Bessel vortex beam. It is shown here, that both transverse and axial forces can push or pull the fluid sphere to an equilibrium position depending on the chosen size parameter ka   (where kk is the wave-number and aa the sphere’s radius). The corresponding results are of particular importance in biophysical applications for the design of lab-on-chip devices operating with Bessel beams standing wave tweezers. Moreover, potential investigations in acoustic levitation and related applications in particle rotation in a vortex beam may benefit from the results of this study.  相似文献   

19.
A.M. Kiss  A. Berkó 《Surface science》2006,600(16):3352-3360
The effect of K on the morphology of Au nanoparticles deposited on TiO2(1 1 0) surface is investigated by STM-STS and AES methods. For comparison, the enhanced concentration of oxygen defect sites generated by Ar+ bombardment was also studied. It was found that both the K additive and the oxygen defect sites induce a pronounced decrease in the average size of the Au nanoparticles evolved at 320 K. On the clean TiO2(1 1 0) the average size of Au particles is 4.3 nm at approximately monolayer coverage of gold, while in the presence of K or oxygen vacancies this value decreased to 2.5 nm. In spite of the reduced average diameter detected at room temperature, the mean size of the Au nanoparticles increased significantly from 2.5 nm up to 7 nm on the effect of annealing at 500-700 K for K precoverages of 0.3-1 ML. For the clean and the Ar+ pretreated TiO2(1 1 0) surfaces the mean size of the Au particles changed only slightly on the effect of the same thermal treatments.  相似文献   

20.
A magnetite ferrofluid coated by dextran with a high specific absorption rate (SAR) of 75 W/g in an AC field of 55 kHz and 200 Oe was prepared by the gel crystallization method with ultrasonic treatment. For comparison, uncoated magnetite particles with a mean diameter of 50 nm were also fabricated. Several possible mechanisms such as Brownian, Neel and diffusion relaxation processes on heating effects and their influence on SAR are discussed. Several factors which can increase the value of SAR were discussed, including dextran coating, ultrasonic treatment, proper particle size and the presence of defects and disorder in the particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号