首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
F.G. Mitri 《Annals of Physics》2008,323(11):2840-2850
The exact analytical solution for the scattering of a generalized (or “hollow”) acoustic Bessel beam in water by an elastic sphere centered on the beam is presented. The far-field acoustic scattering field is expressed as a partial wave series involving the scattering angle relative to the beam axis and the half-conical angle of the wave vector components of the generalized Bessel beam. The sphere is assumed to have isotropic elastic material properties so that the nth partial wave amplitude for plane wave scattering is proportional to a known partial-wave coefficient. The transverse acoustic scattering field is investigated versus the dimensionless parameter ka(k is the wave vector, a radius of the sphere) as well as the polar angle θ for a specific dimensionless frequency and half-cone angle β. For higher-order generalized beams, the acoustic scattering vanishes in the backward (θ = π) and forward (θ = 0) directions along the beam axis. Moreover it is possible to suppress the excitation of certain resonances of an elastic sphere by appropriate selection of the generalized Bessel beam parameters.  相似文献   

2.
Mathematical expressions for the acoustic scattering, instantaneous (linear), and time-averaged (nonlinear) forces resulting from the interaction of a new type of Bessel beam, termed here a first-order non-diffracting Bessel trigonometric beam (FOBTB) with a sphere, are derived. The beam is termed “trigonometric” because of the dependence of its phase on the cosine function. The FOBTB is regarded as a superposition of two equi-amplitude first-order Bessel vortex (helicoidal) beams having a unit positive and negative order (known also as topological charge), respectively. The FOBTB is non-diffracting, possesses an axial null, a geometric phase, and has an azimuthal phase that depends on cos(?±?0), where ?0 is an initial arbitrary phase angle. Beam rotation around its wave propagation axis can be achieved by varying ?0. The 3D directivity patterns are computed, and the resulting modifications of the scattering are illustrated for a rigid sphere centered on the beam's axis and immersed in water. Moreover, the backward and forward acoustic scattering by a sphere vanish for all frequencies. The present paper will shed light on the novel scattering properties of an acoustical FOBTB by a sphere that may be useful in particle manipulation and entrapment, non-destructive/medical imaging, and may be extended to other potentially useful applications in optics and electromagnetism.  相似文献   

3.
F.G. Mitri 《Annals of Physics》2008,323(7):1604-1620
Starting from the exact acoustic scattering from a sphere immersed in an ideal fluid and centered along the propagation axis of a standing or quasi-standing zero-order Bessel beam, explicit partial-wave representations for the radiation force are derived. A standing or a quasi-standing acoustic field is the result of propagating two equal or unequal amplitude zero-order Bessel beams, respectively, along the same axis but in opposite sense. The Bessel beam is characterized by the half-cone angle β of its plane wave components, such that β = 0 represents a plane wave. It is assumed here that the half-cone angle β for each of the counter-propagating acoustic Bessel beams is equal. Fluid, elastic and viscoelastic spheres immersed in water are treated as examples. Results indicate the capability of manipulating spherical targets based on their mechanical and acoustical properties. This condition provides an impetus for further designing acoustic tweezers operating with standing or quasi-standing Bessel acoustic waves. Potential applications include particle manipulation in micro-fluidic lab-on-chips as well as in reduced gravity environments.  相似文献   

4.

Objectives

We introduced a harmonic-to-fundamental ratio (HFR) of the radiofrequency (RF) signals that reduces confounding effects of attenuation. We studied whether HFR analysis of RF signals received from contrast microbubbles allows accurate measurement of the left ventricular (LV) cavity area under varying levels of attenuation.

Background

Attenuation is a fundamental problem in ultrasound imaging and limits the use of clinical echocardiography.

Methods

RF data from short axis systolic and diastolic scans were obtained from 14 open-chest dogs following left-atrial bolus of Optison. Attenuation was induced by interposed silicone pads calibrated to induce 7 dB or 14 dB reductions of the backscattered RF signal. RF images were reconstructed from the RF signals, HFR values calculated for each image pixel for 0 dB, 7 dB and 14 dB attenuation conditions, and LV area obtained by summation of “LV cavity pixels”. A reference LV cavity area was obtained from endocardial border tracings in enhanced scans by experts.

Results

Correlation of the HFR-defined and reference areas at systole was R = 0.95, R = 0.94, and R = 0.91 for 0 dB, 7 dB and 14 dB levels of attenuation, respectively, and at diastole was R = 0.95 for 0 dB, 7 dB and 14 dB levels of attenuation. The mean difference from both systolic and diastolic values was <1.45 cm2 (i.e. negligible) in all attenuation settings.

Conclusion

Our novel HFR method supports precise measurement of the LV cavity area in contrast images with simulated high attenuation of ultrasound signals.  相似文献   

5.
Mitri FG  Fellah ZE 《Ultrasonics》2012,52(1):151-155
In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. = 0) but vanishes when the beam is of vortex type (i.e. > 0, where m is the order (or helicity) of the beam). It has also been recognized that for circularly symmetric beams (such as Bessel beams of integer order), the transverse (lateral) instantaneous force should vanish as required by symmetry. Nevertheless, in this commentary, the present analysis unexpectedly reveals the existence of a transverse instantaneous force on a rigid sphere centered on the axis of a Bessel vortex beam of unit magnitude order (i.e. |m| = 1) not reported in [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724]. The presence of the transverse instantaneous force components of a first-order Bessel vortex beam results from mathematical anti-symmetry in the surface integrals, but vanishes for the fundamental (= 0) and higher-order Bessel (vortex) beams (i.e. |m| > 1). Here, closed-form solutions for the instantaneous force components are obtained and examples for the transverse components for progressive waves are computed for a fixed and a movable rigid sphere. The results show that only the dipole (= 1) mode in the scattering contributes to the instantaneous force components, as well as how the transverse instantaneous force per unit cross-sectional surface varies versus the dimensionless frequency ka (k is the wave number in the fluid medium and a is the sphere’s radius), and the half-cone angle β of the beam. Moreover, the velocity of the movable sphere is evaluated based on the concept of mechanical impedance. The proposed analysis may be of interest in the analysis of transverse instantaneous forces on spherical particles for particle manipulation and rotation in drug delivery and other biomedical or industrial applications.  相似文献   

6.

Background

Permanent prostate brachytherapy (PPB) is a common treatment for early stage prostate cancer. While the modern approach using trans-rectal ultrasound guidance has demonstrated excellent outcome, the efficacy of PPB depends on achieving complete radiation dose coverage of the prostate by obtaining a proper radiation source (seed) distribution. Currently, brachytherapy seed placement is guided by trans-rectal ultrasound imaging and fluoroscopy. A significant percentage of seeds are not detected by trans-rectal ultrasound because certain seed orientations are invisible making accurate intra-operative feedback of radiation dosimetry very difficult, if not impossible. Therefore, intra-operative correction of suboptimal seed distributions cannot easily be done with current methods. Vibro-acoustography (VA) is an imaging modality that is capable of imaging solids at any orientation, and the resulting images are speckle free.

Objective and methods

The purpose of this study is to compare the capabilities of VA and pulse-echo ultrasound in imaging PPB seeds at various angles and show the sensitivity of detection to seed orientation. In the VA experiment, two intersecting ultrasound beams driven at f1 = 3.00 MHz and f2 = 3.020 MHz respectively were focused on the seeds attached to a latex membrane while the amplitude of the acoustic emission produced at the difference frequency 20 kHz was detected by a low frequency hydrophone.

Results

Finite element simulations and results of experiments conducted under well-controlled conditions in a water tank on a series of seeds indicate that the seeds can be detected at any orientation with VA, whereas pulse-echo ultrasound is very sensitive to the seed orientation.

Conclusion

It is concluded that vibro-acoustography is superior to pulse-echo ultrasound for detection of PPB seeds.  相似文献   

7.

Objective and motivation

The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects.

Methods

Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 μs 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVueTM contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the - 6 dB level.

Results

The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2 mm.

Conclusion

These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles.  相似文献   

8.

Introduction

Ultrasound mediated destruction of microbubbles (MBs) has become a promising tool for site specific drug and gene delivery. One of the most important properties of drug-loaded MBs is their destructibility by ultrasound. Therefore, the aim of this study was to establish a new in vitro model that allows evaluation of the kinetics of ultrasound-mediated MB destruction at near physiological conditions.In this work, a newly developed drug-loaded MB formulation was compared with unloaded MBs in order to assess the influence of drug-loading on their acoustic destructibility. Furthermore, drug-loaded MBs were compared to acoustically active lipospheres (AALs), comprising an additional layer of triacetin, as well as to a marketed MB contrast agent (SonoVue®, Bracco Diagnostics, USA), used as standard.

Methods

MBs with phospholipid monolayer shells were produced by mechanical agitation of liposomal dispersions and octafluoropropane gas. AALs were accordingly produced by agitation of phospholipid-stabilized aqueous triacetin microemulsions with gas.The in vitro experimental setup for acoustic destructibility testing comprised a membrane cell, pressurized and brought to 37 °C in order to imitate human blood pressure and body temperature. The optimized egg-like cell shape provided optimal flow conditions and a minimized dead volume.Ultrasound with frequencies of 1 and 3 MHz and intensities, varying from 1 to 4 W/cm2, was applied through a silicone membrane window to the cell. MB size distribution and concentration were measured by light blockage in equal time intervals during the sonication.

Results

The optimized in vitro setup demonstrated differences in the ultrasound destructibility of the MB formulations used. The fastest decay upon ultrasound exposure was found for SonoVue®. Unloaded and drug-loaded MBs appeared to be comparably destructible to SonoVue®. AALs were about 4.5-fold more stable than SonoVue®. MB destructibility was also found to depend on particle diameter, corresponding to theoretical models described in the literature.

Conclusion

The optimized in vitro setup has rendered a fast and reliable laboratory tool for characterization of MB formulations.  相似文献   

9.

Background

High-frequency ultrasonic transducer arrays are essential for high resolution imaging in clinical analysis and Non-Destructive Evaluation (NDE). However, the fabrication of conventional backing-layer structure, which requires a pitch (distance between the centers of two adjacent elements) of half wavelength in medium, is really a great challenge.

Objective and method

Here we present an alternative buffer-layer structure with a silicon lens for volumetric imaging. The requirement for the size of the pitch is less critical for this structure, making it possible to fabricate high-frequency (100 MHz) ultrasonic linear array transducers. Using silicon substrate also makes it possible to integrate the arrays with IC (Integrated Circuit). To compare with the conventional backing-layer structure, a finite element tool, COMSOL, is employed to investigate the performances of acoustic beam focusing, the influence of pitch size for the buffer-layer configuration, and to calculate the electrical properties of the arrays, including crosstalk effect and electrical impedance.

Results

For a 100 MHz 10-element array of buffer-layer structure, the ultrasound beam in azimuth plane in water could be electronically focused to obtain a spatial resolution (a half-amplitude width) of 86 μm at the focal depth. When decreasing from half wavelength in silicon (42 μm) to half wavelength in water (7.5 μm), the pitch sizes weakly affect the focal resolution. The lateral spatial resolution is increased by 4.65% when the pitch size decreases from 42 μm to 7.5 μm. The crosstalk between adjacent elements at the central frequency is, respectively, −95 dB, −39.4 dB, and −60.5 dB for the 10-element buffer, 49-element buffer and 49-element backing arrays. Additionally, the electrical impedance magnitudes for each structure are, respectively, 4 kΩ, 26.4 kΩ, and 24.2 kΩ, which is consistent with calculation results using Krimholtz, Leedom, and Matthaei (KLM) model.

Conclusion

These results show that the buffer-layer configuration is a promising alternative for the fabrication of high-frequency ultrasonic linear arrays dedicated to volumetric imaging.  相似文献   

10.

Purpose

Real-time tissue elastography, a qualitative elastography method, has shown promising results in the diagnostic work up of thyroid nodules. However, to our knowledge no study has evaluated a quantitative elastography method in the thyroid gland. The present study is a feasibility study evaluating Acoustic Radiation Force Impulse-Imaging, a novel quantitative elastography method in the thyroid gland.

Methods

ARFI-imaging involves the mechanical excitation of tissue using short-duration acoustic pulses to generate localized displacements in tissue. The displacements induce a lateral shear-wave propagation which is tracked using multiple laterally positioned ultrasound “tracking“ beams. Inclusion criteria were: thyroid nodules ?1 cm, non-functioning or hypo-functioning on radionuclide scanning, and cytological/histological assessment of thyroid nodule as reference method. All patients received conventional ultrasound, and examination of the thyroid gland including Power Doppler Ultrasound using a 9 MHz linear transducer, in addition real-time elastography (RTE) was performed at 9 MHz frequency and ARFI-imaging was performed at 4 MHz using Siemens (ACUSON S2000) B-mode-ARFI combination transducer.

Results

Sixty nodules in 55 patients were analyzed. Three nodules were papillary carcinoma. The stiffer the tissue the faster the shear wave propagates. The results obtained indicated that the shear wave velocity in thyroid lobes ranged between 0.5 and 4.9 m/s. The median velocity of ARFI-imaging in the healthy nodule-free thyroid gland, as well as in benign and malignant thyroid nodules was 1.98 m/s (range: 1.20-3.63 m/s), 2.02 m/s (range: 0.92-3.97 m/s), and 4.30 m/s (range: 2.40-4.50 m/s), respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.018) or benign thyroid nodules (p = 0.014) on the other hand. Specificity of ARFI-imaging for the differentiation of benign and malignant thyroid nodules was comparable with RTE (91-95%).

Conclusions

ARFI can be performed in the thyroid tissue with reliable results.  相似文献   

11.
F.G. Mitri 《Ultrasonics》2010,50(7):675-682

Background and objective

The analysis of the acoustic backscattering enhancements from tilted cylinders is of particular importance in determining some of the (visco)elastic properties of the cylinder, and/or its surrounding fluid in ultrasonic non-destructive evaluation (NDE) and imaging (NDI) applications. Previous related investigations on an aluminum cylinder limited to incidence angles varying from 0° to 40°, revealed the existence of an anomalous “pseudo-Rayleigh” mode (above the critical Rayleigh angle) identified as the rigid-body translational dipole (n = 1) mode. The objective here is to provide a complete investigation on the backscattering enhancements for incidence angles larger than 40° for various elastic and viscoelastic cylinder materials.

Method

Using the partial-wave series solution for the linear scattering by an infinite circular cylinder, the acoustic backscattering from isotropic elastic and viscoelastic (polymer-type) cylinders excited by an obliquely incident plane acoustic wave is investigated. Total and resonance backscattering form functions are calculated for several elastic and viscoelastic cylinder materials immersed in water versus the angle of incidence 0° ? α < 90°. The “pure” resonance peaks are isolated by subtracting a rigid background from the total form function, so the associated resonance modes are properly identified.

Results and conclusion

The plots of the partial-wave series reveal acoustic backscattering enhancements (not shown in previous investigations) generally occurring at ka? 0.1 at a critical angle αc bounded by the longitudinal and shear waves coupling angles θL=sin-1(c/cL) and θS=sin-1(c/cS) such that θL<αc<θS (where cL and cS are the phase velocities of the longitudinal and shear waves inside the elastic cylinder, and c is the speed of sound in the surrounding medium). It is shown here that the backscattering enhancements with a critical angle θL<αc<θS result from the excitation of the monopole (= 0) resonance mode. Moreover, additional acoustic backscattering enhancements still occur in the range 1 ?ka? 6 even though the angle of tilt is greater than the Rayleigh wave coupling angle θR=sin-1(c/cR) (where cR is the Rayleigh wave velocity in an elastic half-space). The resonance scattering theory shows that such additional enhancements are associated with the excitation of a dipole (n = 1) resonance mode which may result from the interference of meridional and/or helical waves propagating along the cylinder’s surface. It is therefore essential to consider tilt angles ranging from normal to end-on incidence for a complete analysis of the backscattering by elastic and viscoelastic cylinders.  相似文献   

12.
Shen CC  Su SY  Cheng CH  Yeh CK 《Ultrasonics》2012,52(1):25-32

Objective

The goal of this work is to examine the effects of pulse-inversion (PI) technique in combination with dual-frequency (DF) excitation method to separate the high-order nonlinear responses from microbubble contrast agents for improvement of image contrast. DF excitation method has been previously developed to induce the low-frequency ultrasound nonlinear responses from bubbles by using the composition of two high-frequency sinusoids (f1 and f2).

Motivation

Although the simple filtering was conventionally utilized to provide signal separation, the PI approach is better in the sense that it minimizes the mutual interferences among these high-order nonlinear responses in the presence of spectral overlap. The novelty of the work is that, in addition to the common PI summation, the PI subtraction was also applied in DF excitation method.

Methods

DF excitation pulses having an envelope frequency of 3 MHz (i.e., f1 = 8.5 MHz and f2 = 11.5 MHz) with pulse lengths of 3-10 μs and the pressure amplitudes from 0.5 to 1.5 MPa were used to interrogate the nonlinear responses of SonoVue™ microbubbles in the phantom experiments. The high-order nonlinear responses in the DF excitation were extracted for contrast imaging using PI summation for even-order nonlinear components or PI subtraction for odd-order nonlinear ones.

Results

Our results indicated that, as compared to the conventional filtering technique, the PI processing effectively increases the contrast-to-tissue ratio (CTR) of the third-order nonlinear response at 5.5 MHz and the fourth-order nonlinear response at 6 MHz by 2-5 dB. For these high-order nonlinear components, the CTR increase varies with the transmission pressures from 0.5 to 1.5 MPa due to the microbubbles’ displacement induced by the radiation force of DF excitation.

Conclusions

For DF excitation technique, the PI processing can help to extract either the odd-order or the even-order nonlinear components for higher CTR estimates.  相似文献   

13.

Objectives

Curcumin, a natural pigment from the traditional Chinese herb, has shown promise as an efficient enhancer of ultrasound. The present study aims to investigate ultrasound-induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin in vitro.

Methods

Nasopharyngeal carcinoma cell line CNE2 cells were incubated by 10 μm curcumin and then were treated by ultrasound for 8 s at the intensity of 0.46 W/cm2. Cytotoxicity was evaluated using MTT assay and light microscopy. Mitochondrial damage was analyzed using a confocal laser scanning microcopy with Rhodamine 123 and ultrastructural changes were observed using a transmission electron microscopy (TEM).

Results

MTT assay showed that cytotoxicity induced by ultrasound treatment alone and curcumin treatment alone was 18.16 ± 2.37% and 24.93 ± 8.30%, respectively. The cytotoxicity induced by the combined treatment of ultrasound and curcumin significantly increased up to 86.67 ± 7.78%. TEM showed that microvillin disappearance, membrane blebbing, chromatin condensation, swollen mitochondria, and mitochondrial myelin-like body were observed in the cells treated by ultrasound and curcumin together. The significant collapse of mitochondrial membrane potential (MMP) was markedly observed in the CNE2 cells after the combined treatment of curcumin and ultrasound.

Conclusions

Our findings demonstrated that ultrasound sonication in the presence of curcumin significantly killed the CNE2 cells and induced ultrastructural damage and the dysfunction of mitochondria, suggesting that ultrasound treatment remarkably induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin.  相似文献   

14.
The axial and transverse radiation forces on a fluid sphere placed arbitrarily in the acoustical field of Bessel beams of standing waves are evaluated. The three-dimensional components of the time-averaged force are expressed in terms of the beam-shape coefficients of the incident field and the scattering coefficients of the fluid sphere using a partial-wave expansion (PWE) method. Examples are chosen for which the standing wave field is composed of either a zero-order (non-vortex) Bessel beam, or a first-order Bessel vortex beam. It is shown here, that both transverse and axial forces can push or pull the fluid sphere to an equilibrium position depending on the chosen size parameter ka   (where kk is the wave-number and aa the sphere’s radius). The corresponding results are of particular importance in biophysical applications for the design of lab-on-chip devices operating with Bessel beams standing wave tweezers. Moreover, potential investigations in acoustic levitation and related applications in particle rotation in a vortex beam may benefit from the results of this study.  相似文献   

15.
F.G. Mitri 《Ultrasonics》2009,49(8):794-798

Background and objective

Particle manipulation using the acoustic radiation force of Bessel beams is an active field of research. In a previous investigation, [F.G. Mitri, Acoustic radiation force on a sphere in standing and quasi-standing zero-order Bessel beam tweezers, Annals of Physics 323 (2008) 1604–1620] an expression for the radiation force of a zero-order Bessel beam standing wave experienced by a sphere was derived. The present work extends the analysis of the radiation force to the case of a high-order Bessel beam (HOBB) of positive order m having an angular dependence on the phase ?.

Method

The derivation for the general expression of the force is based on the formulation for the total acoustic scattering field of a HOBB by a sphere [F.G. Mitri, Acoustic scattering of a high-order Bessel beam by an elastic sphere, Annals of Physics 323 (2008) 2840–2850; F.G. Mitri, Equivalence of expressions for the acoustic scattering of a progressive high order Bessel beam by an elastic sphere, IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 56 (2009) 1100–1103] to derive the general expression for the radiation force function YJm,st(ka,β,m), which is the radiation force per unit characteristic energy density and unit cross-sectional surface. The radiation force function is expressed as a generalized partial wave series involving the half-cone angle β of the wave-number components and the order m of the HOBB.

Results

Numerical results for the radiation force function of a first and a second-order Bessel beam standing wave incident upon a rigid sphere immersed in non-viscous water are computed. The rigid sphere calculations for YJm,st(ka,β,m) show that the force is generally directed to a pressure node when m is a positive even integer number (i.e. YJm,st(ka,β,m)>0), whereas the force is generally directed toward a pressure antinode when m is a positive odd integer number (i.e. YJm,st(ka,β,m)<0).

Conclusion

An expression is derived for the radiation force on a rigid sphere placed along the axis of an ideal non-diffracting HOBB of acoustic standing (or stationary) waves propagating in an ideal fluid. The formulation includes results of a previous work done for a zero-order Bessel beam standing wave (m = 0). The proposed theory is of particular interest essentially due to its inherent value as a canonical problem in particle manipulation using the acoustic radiation force of a HOBB standing wave on a sphere. It may also serve as the benchmark for comparison to other solutions obtained by strictly numerical or asymptotic approaches.  相似文献   

16.

Objective and motivation

Intravascular ultrasound (IVUS) allows in vivo invasive intra-luminal real-time examination of the arterial wall structure. In this study, we aimed to validate for the first time the in vivo IVUS performing as a diagnostic tool by comparison to the well-established histomorphometry approach, in the largely used rat model of carotid angioplasty model that mimics the angioplasty procedure in humans.

Methods

Atherosclerotic lesions were allowed to develop during four weeks after balloon catheter inflation of the left carotid artery, whereas the intact right carotid artery was used as control. Four weeks after injury, a Boston Scientific 40 MHz device to perform IVUS exams in vivo on both carotid arteries. Then, both carotid arteries were examined in vitro by histomorphometry and correlation between IVUS and histomorphometric parameters (plaque plus media cross-sectional areas [CSA] and eccentricity index) were researched.

Results

After ANOVA analysis, comparative statistical analysis showed significant correlations between IVUS and histomorphometry when examining the intact right carotid artery (r = 0.662 with p < 0.003 for plaque plus media CSA; r = 0.774 with p < 0.002 for eccentricity index), but also when exploring the injured left carotid artery (r = 0.805 with p < 0.0001 for plaque plus media CSA; r = 0.775 with p < 0.002 for eccentricity index).

Conclusions and outcome

We report here for the first time the ability of IVUS to study therapeutic vascular effects in vivo in alive rats. This result is of major importance since it will allow this device to be used for restenosis drug testing in rat model of carotid angioplasty.  相似文献   

17.
王明升  李威 《声学学报》2020,45(1):87-93
通过声散射理论,将水中粒子的Bessel波束声散射场的分波序列(PWS)表达公式加以推广,进而推导出声辐射力的表达公式,获得了液体球及弹性球在Bessel波束下声辐射力的变化规律。通过观察不同散射角形态函数,可发现声辐射力的产生与粒子背向散射抑制程度有关。对于液体球粒子,球壳厚度及材料介质对粒子声辐射力有着重要的影响,同时Bessel波束波锥角越大,产生负声辐射力的可能性越大。对于弹性球和弹性单层壳粒子,声辐射力的产生与其本身的共振特征存在很大的关系。同时,通过改变球壳内介质及壳层厚度的方法,可增加产生的负声辐射力的频率范围及幅值强度.   相似文献   

18.
Doinikov AA  Haac JF  Dayton PA 《Ultrasonics》2009,49(2):263-1403
Knowledge of resonant frequencies of contrast microbubbles is important for the optimization of ultrasound contrast imaging and therapeutic techniques. To date, however, there are estimates of resonance frequencies of contrast microbubbles only for the regime of linear oscillation. The present paper proposes an approach for evaluating resonance frequencies of contrast agent microbubbles in the regime of nonlinear oscillation. The approach is based on the calculation of the time-averaged oscillation power of the radial bubble oscillation. The proposed procedure was verified for free bubbles in the frequency range 1-4 MHz and then applied to lipid-shelled microbubbles insonified with a single 20-cycle acoustic pulse at two values of the acoustic pressure amplitude, 100 kPa and 200 kPa, and at four frequencies: 1.5, 2.0, 2.5, and 3.0 MHz. It is shown that, as the acoustic pressure amplitude is increased, the resonance frequency of a lipid-shelled microbubble tends to decrease in comparison with its linear resonance frequency. Analysis of existing shell models reveals that models that treat the lipid shell as a linear viscoelastic solid appear may be challenged to provide the observed tendency in the behavior of the resonance frequency at increasing acoustic pressure. The conclusion is drawn that the further development of shell models could be improved by the consideration of nonlinear rheological laws.  相似文献   

19.
We propose a new method for transformation of a Laguerre-Gaussian beam of azimuthal index l and radial index n = 0 (LGl,0) into a vortex, diverging or nondiverging Bessel beam, which can have increased or decreased phase singularity order, or into a zeroth order Bessel beam, by means of a helical axicon. The Bessel beam divergence or nondivergence depends upon the waist position of the input Laguerre-Gaussian beam, regarding the plane where the helical axicon is situated.The expressions for the amplitude and the intensity distribution of the diffracted wave field, in the process of Fresnel diffraction, are deduced using the stationary phase method. The theoretical analysis for the vortex radius and the maximum propagation distance of the Bessel beams obtained is presented.  相似文献   

20.

Introduction

Elastic modulus estimation may be an important clinical criterion, as it seems to affect such eye parameters as intraocular pressure, ocular pulsation, blood flow, effect of topical medications, and post-refractive surgery complications. The purpose of this study was to examine the differences in elasticity in the ocular axial length, posterior wall thickness (posterior pole), and retina-choroid thickness under normal and aged-related macular degeneration (AMD) conditions in the human eye by directly estimating the elastic modulus with sequential and noninvasive ultrasound image processing.

Materials and Methods

In this study, 25 healthy subjects and 20 patients with non-neovascular AMD participated in the experiment. The deformation of the ocular axial length, posterior wall thickness and retina-choroid complex thickness was captured using high-resolution ultrasonography before and after loading. The B-mode (20 MHz) and A-mode (8 MHz) frames were obtained and processed with an echo tracking technique. The elastic modulus was estimated using changes in ocular axial length, posterior wall thickness and retina-choroid complex thickness and with applied stress measurements.

Results

There was a significant difference (p < 0.05) in the ocular axial length elastic modulus between the AMD and healthy subjects (AMD patients: 95.165 ± 26.431 kPa, vs. healthy subjects: 49.539 ± 25.867 kPa). Moreover, there was a statistically significant difference (p < 0.05) in the posterior wall thickness elastic modulus between AMD patients and healthy subjects (AMD patients: 50.519 ± 12.295 kPa, vs. healthy subjects: 20.519 ± 11.827 kPa). However, no statistically significant difference (p-value > 0.05) was found in the retina-choroid complex elastic modulus between the two groups (AMD patients: 20.134 ± 3.898 kPa, vs. healthy subjects: 15.630 ± 4.250 kPa).

Conclusion

Although the results were obtained examining a relatively low number of patients, it would appear that noninvasive ultrasound estimation of the local elastic moduli of ocular axial length and posterior wall thickness is suited to aid in detection of the non-exudative AMD thus manifesting its potential as a screening tool in symptom-free individuals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号