1.
《Microchemical Journal》2009,91(2):107-112
A simple and powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 mL of its aqueous sample in the pH = 6 as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) cationic complex into a 4 µL drop of nitrobenzene and ammonium tetraphenylborate as counter ion. In the drop, the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [Pd(c) + Pd(i)]. Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 390 and 78%, respectively. The calibration graph was linear in the range of 0.01–1 µg L 1 with correlation coefficient of 0.9952 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0065 µg L 1 and relative standard deviation (RSD) for eight replicate measurements of 0.1 µg L 1 and 0.4 µg L 1 cadmium was 6.4 and 5.8% respectively. The characteristic concentration was 0.0014 µg L 1 equivalent to a characteristic mass of 5.6 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.  相似文献   

2.
A simple, rapid and low-cost electroanalytical method is proposed for the determination of acetaminophen (ACP) and codeine (COD) at nanomolar levels in pharmaceutical and biological samples. The analytical procedure is based on a flow injection analysis system coupled to electrochemical detection, which was multiple pulse amperometry (FIA-MPA). Boron-doped diamond was used as the working electrode for electrochemical detection. The electrode was subjected to a cathodic pretreatment and was selected in this work due its good electrochemical performance. By applying the FIA-MPA method, after a number of optimization assays, the analgesics were simultaneously determined at excellent linear concentration ranges. The analytical curves ranged from 80 nmol L−1 to 100 µmol L−1 for ACP and from 50 nmol L−1 to 10 µmol L−1 for COD, and the obtained limits of detection were 30 nmol L−1 and 35 nmol L−1 for ACP and COD, respectively. The practical applicability of the electroanalytical method was evaluated from the ACP and COD determination in two sample matrices: commercial pharmaceutical samples and biological fluids. In the case of pharmaceutical formulation samples, the obtained results were statistically similar to those obtained using a reference chromatographic method. In addition, these drugs were simultaneously quantified in biological fluid samples of urine and human serum with excellent recovery percentages.  相似文献   

3.
Using a solid phase extraction mini-column home-made from a neutral extractant Cyanex 923, inorganic Hg could be on-line preconcentrated and simultaneously separated from methyl mercury. The preconcentrated Hg (II) was then eluted with 10% HNO3 and subsequently reduced by NaBH4 to form Hg vapor before determination by cold vapor atomic absorption spectrometry (CVAAS). Optimal conditions for and interferences on the Hg preconcentration and measurement were at 1% HCl, for a 25 mL sample uptake volume and a 10 mL min 1 sample loading rate. The detection limit was 0.2 ng L 1 and much lower than that of conventional method (around 15.8 ng L 1). The relative standard deviation (RSD) is 1.8% for measurements of 40 ng L 1 of Hg and the linear working curve is from 20 to 2000 ng L 1 (with a correlation coefficient of 0.9996). The method was applied in determination of inorganic Hg in city lake and deep well water (from Changchun, Jilin, China), and recovery test results for both samples were satisfactory.  相似文献   

4.
《Microchemical Journal》2008,88(2):132-138
In the present work, a simple and sensitive preconcentration-microwave plasma torch-atomic emission spectrometric procedure was carried out for the determination of cobalt and nickel. The method was based upon a flow-injection system with on-line preconcentration of the metal ions on a minicolumn of a strong acid cation-exchange resin. The operation parameters including sample acidity, flow rate, loading time, and eluent concentration, flow rate were studied and optimized. Under the optimal experimental conditions the enrichment factors were calculated as 13.58 and 17.65 for cobalt and nickel, respectively. The relative standard deviations, 3.73% for cobalt and 4.23% for nickel (n = 7), and a sample throughput of 40 h 1 were obtained. Furthermore, the limits of detection were shown to be 1.28 and 1.80 μg·L 1 for cobalt and nickel, respectively. The method was applied to the determination of cobalt and nickel in tea samples and the accuracy was assessed through recovery experiments.  相似文献   

5.
The paper presents the preconcentration of trace elements via electrodeposition onto a (micro)aluminum cathode in the presence of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [BMIM][PF6] as a supporting electrolyte. The advantages of the proposed method include very simple instrumentation for the preconcentration of trace elements and low-cost reagents. The experiment showed that the use of ionic liquid in the electrodeposition process significantly improves sensitivity, recovery and detection limits for the determination of trace amounts of iron, cobalt, nickel and zinc. The preconcentrated metals were determined using X-ray fluorescence spectrometry. The optimum parameters for electrodeposition such as pH, the volume of the analyzed solution, the voltage and the deposition time were studied. Under the optimized conditions, the detection limits were 5, 2, 3 and 6 μg L 1 for iron, cobalt, nickel and zinc, respectively. The precision and recovery of the method were in the range of 3–5.5%, and 92–103%, respectively. The calibration was performed using aqueous standards of Fe(III), Co(II), Ni(II) and Zn(II) in the range 0.01–0.25 mg L 1. The method was applied successfully in water analysis.  相似文献   

6.
A flow injection on-line displacement solid-phase extraction protocol was employed to minimize mass interferences with determination of palladium by inductively coupled plasma mass spectrometry (ICP-MS). The developed method involved in on-line complexing of Ag+ with pyrrolidine dithiocarbamate (PDC), presorption of the resultant Ag–PDC onto a microcolumn packed with the cigarette filter, displacement sorption of Pd2+ through loading the sample solution onto the microcolumn due to on-line displacement reaction between Pd2+ and the presorbed Ag–PDC, elution of the retained Pd2+ with 50 μL of ethanol for on-line ICP-MS detection. Interferences from co-existing heavy metal ions with lower stability of their PDC complexes relative to Ag–PDC were minimized/eliminated. No interferences from 5 mg L 1 Zn and 3 mg L 1 Pb for 104Pd, 0.4 mg L 1 Cu for 105Pd, 6 mg L 1 Zn and 2 mg L 1 Cd for 106Pd, 6 mg L 1 Zn and 3 mg L 1 Cd for 108Pd, and 2 mg L 1 Cd for 110Pd were observed for the determination of 100 ng L 1 Pd. The enhancement factors of 71–75, sample throughput of 23 samples h 1 and detection limits of 2.8–3.5 ng L 1 were achieved with the consumption of 3.0 mL of sample solution. The precision (RSD) for eleven replicate determinations of Pd at the 100 ng L 1 level was 1.8–2.7%. The developed method was applied to the determination of palladium in rock samples.  相似文献   

7.
This paper reports an electroanalytical method developed for determining the antioxidant tert-butylhydroquinone (TBHQ) in biodiesel, based on the enhancement effect of cetyltrimethylammonium bromide (CTAB). In pH 6.5 Britton–Robinson buffer, a poorly defined oxidation peak was observed for TBHQ at a carbon paste electrode (CPE). In the presence of low concentrations of CTAB, however, the oxidation peak current was markedly increased. Several parameters were studied and optimized for the development of this methodology, and under optimal conditions the oxidation peak current was proportional to TBHQ concentration in the range of (1.05–10.15) × 10−6 mol L−1, with limits of detection and quantification of 7.11 × 10−8 mol L−1 and 2.37 × 10−7 mol L−1, respectively, by linear sweep voltammetry (LSV). The method was applied to TBHQ determination in soybean biodiesel samples. The results were satisfactory in comparison with those obtained using high-performance liquid chromatography (HPLC).  相似文献   

8.
A novel procedure for trace methylmercury determinations by anodic stripping voltammetry at a gold film electrode is presented. Measurements were performed in a flow system. For selective determination of methylmercury, the Hg2+ ions were masked by complexation with DTPA. Hg-DTPA complex is not reduced at the gold film electrode at the potential of methylmercury reduction to the metallic state. The calibration graph was linear from 5 × 10−9 to 1 × 10−7 mol L−1 for an accumulation time 600 s. A detection limit (based on 3σ criterion) for methylmercury was 2.3 × 10−9 mol L−1. The validation of the proposed procedure was made by analyses of human hair certified reference material.  相似文献   

9.
A novel poly(p-xylenolsulfonephthalein) modified glassy carbon electrode was prepared for the simultaneous determination of ascorbic acid (AA), epinephrine (EP) and uric acid (UA). Cyclic voltammetric, chronoamperometric, and differential pulse voltammetric methods were used to investigate the modified electrode for the electrocatalytic oxidation of EP, AA, and UA in aqueous solutions. The separation of the oxidation peak potentials for AA–EP and EP–UA was about 200 and 130 mV, respectively. The calibration curves obtained for AA, EP, and UA were in the ranges of 10–1343, 2–390, and 0.1–560 μmol L−1, respectively. The detection limits (S/N = 3) were 4, 0.1, and 0.08 μmol L−1 for AA, EP and UA, respectively. The diffusion coefficient and the catalytic rate constant for the oxidation of EP at the modified electrode were calculated as 1.40(±0.10) × 10−4 cm2 s−1 and 1.06 × 103 mol−1 L s−1, respectively. The present method was applied to the determination of EP in pharmaceutical and urine samples, AA in commercially available vitamin C tablet, and EP plus UA in urine samples.  相似文献   

10.
A method for the determination of Cu, As, Se, Cd, In, Hg, Tl, Pb and Bi in waters and in biological materials by inductively coupled plasma mass spectrometry, after an on-line separation, is described. The matrix separation and analyte preconcentration is accomplished by retention of the analytes complexed with the ammonium salt of O,O-diethyl dithiophosphoric acid in a HNO3 solution on C18 immobilized on silica in a minicolumn. Methanol, as eluent, is introduced in the conventional pneumatic nebulizer of the instrument. In order to use the best compromise conditions, concerning the ligand and acid concentrations, the analytes were determined in two separate groups. The enrichment factors were in the range from 5 to 61, depending on the analyte. The limits of detection varied from 0.43 ng L−1 for Bi to 33 ng L−1 for Cu. The sample consumption is only 2.3 mL for each group and the sampling frequency is 21 h−1. The accuracy was tested by analysing five certified reference materials: water, riverine water, urine, bovine muscle and bovine liver. The agreement between obtained and certified concentrations was very good, except for As. The relatively small volume of methanol, used as eluent, minimizes the problems produced by the introduction of organic solvent into the plasma.  相似文献   

11.
In this work, the potential of modified multiwalled carbon nanotubes for separation and preconcentration of trace amounts of manganese ion is studied. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and then modified with loading 1-(2-pyridylazo)-2-naphtol. Mn(II) ions could be quantitatively retained by modified multiwalled carbon nanotubes in the pH range of 8–9.5. Elution of the adsorbed manganese was carried out with 5.0 mL of 0.1 mol L?1 HNO3. Detection limit is 0.058 ng mL?1 and analytical curve is linear in the range of 0.1 ng mL?1–5.0 μg mL?1 in the initial solution with a correlation coefficient 0.9977 and the preconcentration factor is 100. Relative standard deviation for eight replicate determination of 0.5 μg mL?1 of manganese in the final solution is 0.41%. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions, were studied for preconcentration of Mn(II) ions in detail to optimize the conditions. The method was successfully applied for separation, preconcentration and determination of manganese in different samples.  相似文献   

12.
Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with Pd as chemical modifier. The efficiency of As and Ge as internal standards for 25 μg L 1 Se plus 500 μg L 1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte (axis x). The equations that describe the linear regression were: AAs =  0.004 ± 0.019 + 1.02 ± 0.019 ASe (r = 0.9967 ± 0.005); AGe =  0.017 ± 0.015 + 1.01 ± 0.015 ASe (r = 0.9978 ± 0.004). Samples and reference solutions were automatically spiked with 500 μg L 1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 μL of aqueous standard solutions, analytical curves in the 5.00–40.0 μg L 1 Se range were established using the ratio of Se absorbance to internal standard absorbance (ASe / AIS) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 μg L 1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 μg L 1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99–105% range with IS and in the 70–80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 μg L 1.  相似文献   

13.
《Microchemical Journal》2011,97(2):337-343
An analytical protocol combining a headspace technique with gas chromatography and detection by photoionization detector and flame ionization detector (HS-GC-PID-FID) was developed. This procedure was used to measure volatile organic compounds (VOCs) in environmental aqueous matrices and was applied in determination of VOCs on the coast of Fortaleza, Brazil. At optimum operating conditions, analytical figures of merit such as linearity (R ranged from 0.9983 to 0.9993), repeatability (5.62 to 9.63% and 0.02 to 0.19% for the quantitative and qualitative analyses, respectively), detection limits (0.22 to 7.48 μg L1) and sensibility were estimated. This protocol favors a fast sampling/sample preparation (in situ), minimizes the use of laboratory material, eliminates the matrix effect from environmental samples, and can be applied to river, estuarine and oceanic waters. The advantage of detectors in series is that a low sensitivity in detection in one is compensated by the other. Toluene was the most abundant VOC in the studied area, with an average concentration of 1.63 μg L1. It was followed by o-xylene (1.15 μg L1), trichloroethene (1.08 μg L1), benzene (0.86 μg L1), ethylbenzene (0.74 μg L1), carbon tetrachloride (0.55 μg L1), m/p-xylene (0.48 μg L1) and tetrachloroethene (0.46 μg L1), compounds which are very commonly detected in urban runoff from most cities. The results of the VOC distribution showed that port activity was not the main source of VOCs along the Fortaleza Coast, but that the contribution from urban runoff seemed more significant.  相似文献   

14.
A novel electrochemical platform was designed and prepared for simultaneous determination of p-acetaminophen (AMP) and p-aminophenol (AP) by combining the excellent conductivity and electrocatalytic activities of tetraaminophenyl porphyrin functionalized multi-walled carbon nanotubes (CNTs-CONH-TAPP) and gold nanoparticles (AuNPs). The as-synthesized CNTs-CONH-TAPP composites were characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and scanning electron microscope. The incisive oxidation current responses of AMP and AP at the modified electrode promised a sensitive and selective simultaneous determination of AMP and AP. Under optimized conditions, the peak currents were directly proportional to the concentrations of AMP and AP over the ranges of 4.5–500 μmol L−1 and 0.08–60 μmol L−1, respectively, and the limits of detection were 0.44 μmol L−1 for AMP and 0.025 μmol L−1 for AP(S/N = 3) respectively. The proposed modified electrode showed excellent selectivity, reproducibility and long-term stability and could be applied in simultaneous determination of p-acetaminophen and p-aminophenol in real samples.  相似文献   

15.
《Microchemical Journal》2011,97(2):194-202
Vertical profiles for total dissolved thallium were obtained at five sites in the western sector of the Ross Sea (Southern Ocean), Antarctica. Thallium is estimated to have a natural mean seawater concentration between 50 and 65 pmol L 1 with higher values in the North Pacific (65 ± 5 pmol L 1) and lower in the Bay of Biscay and Irish Sea (49 ± 3 pmol L 1). Our samples show a concentration varying from 22 to 55 pmol L 1 with a mean value of 46 pmol L 1, depending on depth, dissolved oxygen, salinity and local topographic characteristics. The analyses were performed using an ICP-SFMS that has enabled us to obtain reliable Tl concentration measurements with a relative standard deviation of better than 2.5% and a detection limit, calculated as three times the standard deviation of the “blank signal” of 0.69 pmol L 1 (1.60 pmol L 1, obtained analysing four blank solutions (n = 5) prepared with the same water and acid used for the dilution/acidification steps). Thallium appears to have a nearly conservative distribution in seawater as highlighted also from the comparison with the profiles of two seawater conservative elements: molybdenum and uranium; however it also highlights the presence of a reactive component of thallium, which is more influenced by the presence of particulate matter, oxygen content and fluorescence.  相似文献   

16.
《Microchemical Journal》2011,97(2):348-351
A sensitive and selective preconcentration method using solid-phase extraction (SPE) disk, namely multiwalled carbon nanotubes (MWCNTs) disk, is proposed for the determination of atrazine and simazine in water samples. Atrazine and simazine were extracted on MWCNTs disk and then determined by gas chromatography–mass spectrometry (GC/MS). Several parameters on the enrichment factor of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 5 using 200 mL of validation solution containing 0.1 μg of triazines and 5 mL of acetone as an eluent. The maximum enrichment factors for atrazine and simazine were 3900 ± 250 and 4000 ± 110, respectively when 200 mL of sample solution volume was used. Relative standard deviations for seven determinations were 6.9% (atrazine) and 3.0% (simazine) under optimum conditions. The linear range of calibration curves were 0.1 to 1 ng mL 1 for each analyte with good correlation coefficients. The detection limits (3S/N) were 2.5 and 5.0 pg mL 1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of atrazine and simazine in environmental water samples with high precision and accuracy.  相似文献   

17.
A fast and sensitive procedure for extraction and preconcentration of molybdenum in plant samples based on solidified floating organic drop microextraction combined with flame atomic absorption spectrometry and discrete nebulization was developed. 8-Hydroxyquinoline (8-HQ) was used as complexing agent. The experimental conditions established were: 0.5% m v 1 of 8-HQ, 60 μL of 1-undecanol as the extractant phase, 2 min vortex extraction time, centrifugation for 2 min at 2000 rpm, 10 min into an ice bath and discrete nebulization by introducing 200 μL of solution. The calibration curve was linear from 0.02 to 4.0 mg L 1 with a limit of detection of 4.9 μg L 1 and an enhancement factor of 67. The relative standard deviations for ten replicate measurements of 0.05 and 1.0 mg L 1 Mo were 6.0 and 14.5%, respectively. The developed procedure was applied for determining molybdenum in corn samples and accuracy was proved using certified reference materials.  相似文献   

18.
A study of organic loading rate (OLR) and effect of NaOH concentration on the pretreatment stage of corn husk (CH) was conducted by Face-Centered Central Composite Design (CCF) to improve the biogas production. Three levels of OLR at 25.0 g VS · L−1 · d−1 (OLR25), 35.0 g VS · L−1 · d−1 (OLR35), and 45.0 g VS · L−1 · d−1 (OLR45) were performed with NaOH pretreatment concentration of CH at 25.0% (N25), 35.0% (N35), and 45.0% (N45) (w/w). The optimum production of biogas at 67.6 mL · min−1 with methane concentration of 63.4% has been obtained at the application of OLR at 43.6 g VS · L−1 · d−1 and NaOH concentration at 33% (w/w).  相似文献   

19.
A polymeric blend has been prepared using urea formaldehyde (UF) and epoxy (DGEBA) resin in 1:1 mass ratio. The thermal degradation of UF/epoxy resin blend (UFE) was investigated by using thermogravimetric analyses (TGA), coupled with FTIR and MS. The results of TGA revealed that the pyrolysis process can be divided into three stages: drying process, fast thermal decomposition and cracking of the sample. There were no solid products except ash content for UFE during combustion at high temperature. The total mass loss during pyrolysis at 775 °C is found to be 97.32%, while 54.14% of the original mass was lost in the second stage between 225 °C and 400 °C. It is observed that the activation energy of the second stage degradation during combustion (6.23 × 10−4 J mol−1) is more than that of pyrolysis (5.89 × 10−4 J mol−1). The emissions of CO2, CO, H2O, HCN, HNCO, and NH3 are identified during thermal degradation of UFE.  相似文献   

20.
A thionine modified aligned carbon nanotubes (ACNTs) electrode was fabricated and was used to electrochemically determine nitrite. The thionine modified ACNTs electrode exhibited enhanced electrocatalytic behavior to the oxidation of nitrite. The electrochemical mechanism of the thionine/ACNTs electrode towards the oxidation of nitrite was discussed. The thionine modified ACNTs electrode exhibited fast response towards nitrite with a detection limit of 1.12 × 10−6 mol  L−1 and a linear range of 3 × 10−6 – 5 × 10−4 mol  L−1. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   