首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The IUPAC Recommendations on pH (1985) have serious metrological deficiencies (recommendation of two pH scales and of several pH definitions and procedures to measure pH). Background and essential features of new recommendations, which replace the 1985 document, are reported in this paper. The new document is strictly based on metrological principles. pH is defined (notionally) by the negative logarithm of the hydrogen ion activity according to S?rensen and Linderstr?m-Lang (1924), that is pH=-lg a(H). Because pH is a single ion quantity it is immeasurable and is therefore experimentally verified, with stated uncertainties, by pH(PS) values of primary standard buffer solutions. The assignment of pH(PS) is carried out in a Harned cell (without transference), which is defined as a primary method of measurement, and involves the Bates-Guggenheim convention. pH(PS) is thus a conventional quantity. Consideration of the uncertainty of the Bates-Guggenhein convention, however, permits its incorporation into the internationally accepted SI system of measurement. Comparison of the pH of secondary buffer solutions with pH(PS) values in recommended cells with transference yields secondary standards, whose pH(SS) can be traced back to pH(PS) and consequently to the definition of pH. The traceability chain is continued "downwards" by practical cells with transference containing glass electrodes for the measurement of pH(X) values of unknown solutions, for which three calibration procedures are recommended. The measurement of pH is thus represented by the traceability chain pH(X)-->pH(SS)-->pH(PS)-->pH as defined, each step having stated uncertainties. This hierarchical system of measurement excludes any pH 'scale'. Tabulated pH(PS) values are given as examples, and it is recommended that actual pH(PS) and pH(SS) be taken from certificates, which are to accompany each lot of certified reference material (CRM). Target uncertainties and examples of their calculation, a sign convention for pH cells and conventions for presenting cell schemes are given in the new document.  相似文献   

2.
Formulations are given both for narrow (less than 2 pH units) and for wide range (up to 8 pH units) immobilized pH gradients, spanning between pH 2.5 and pH 11. The contribution from water to the buffering power (beta) at these pH extremes requires the recipes to be optimized (in terms of gradient linearity) for each desired level of beta av.  相似文献   

3.
Nano-electrospray-ionization mass spectrometry (nano-ESI-MS) is applied to comparison of bovine and porcine beta-lactoglobulin (BLG and PLG). The conformational and oligomeric properties of the two proteins under different solvent and experimental conditions are analyzed. The pH-dependence of dimerization is described for the pH range 2-11. The results indicate maximal dimer accumulation at pH 6 for BLG and pH 4 for PLG, as well as a lower stability of the PLG dimer at pH 4 compared to BLG at pH 6. Conformational stability appears to be higher for BLG at acidic pH, but higher for PLG at basic pH. The higher stability of BLG at low pH is revealed by means of either chemical or thermal denaturation. Equilibrium folding intermediates of both proteins are detected. Finally, conditions are found that promote dissociation of the BLG dimer at pH 6 into folded monomers.  相似文献   

4.
In this study, preparation of novel pH-sensitive N-doped carbon dots (NCDs) using glucose and urea is reported. The prepared NCDs present strong excitation-dependent fluorescence changes towards the pH that is a new behavior from these nanomaterials. By taking advantage of this unique behavior, two separated ratiometric pH sensors using emission spectra of the NCDs for both acidic (pH 2.0 to 8.0) and basic (pH 7.0 to 14.0) ranges of pH are constructed. Additionally, by considering the entire Excitation–Emission Matrix (EEM) of NCDs as analytical signal and using a suitable multivariate calibration method, a broad range of pH from 2.0 to 14.0 was well calibrated. The multivariate calibration method was independent from the concentration of NCDs and resulted in a very low average prediction error of 0.067 pH units. No changes in the predicted pH under UV irradiation (for 3 h) and at high ionic strength (up to 2 M NaCl) indicated the high stability of this pH nanosensor. The practicality of this pH nanosensor for pH determination in real water samples was validated with good accuracy and repeatability.  相似文献   

5.
The thermodynamic parameters for the binding of dodecyl trimethylammonium bromide (DTAB) with wigeon hemoglobin (Hb) in aqueous solution at various pH and 27 °C have been measured by equilibrium dialysis and titration microcalorimetry techniques. The Scatchard plots represent unusual features at neutral and alkaline pH and specific binding at acidic pH. This leads us to analyze the binding data by fitting the data to the Hill equation for multiclasses of binding sites. The best fit was obtained with the equation for one class at acidic pH and two classes at neutral and alkaline pH. The thermodynamic analysis of the binding process shows that the strength of binding at neutral pH is more than these at other pH values. This can be related to the more accessible hydrophobic surface area of wigeon hemoglobin at this pH. The endothermic enthalpy data which was measured by microcalorimetry confirms the binding data analysis and represents the more regular and stable structure of wigeon hemoglobin at neutral pH.  相似文献   

6.
This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapid result. However, the problems posed by the traceability of pH are not easy to solve. Most pH measurements are performed by potentiometry, using a glass electrode as the pH sensor. Such pH electrodes must be calibrated at regular intervals. Confidence in the reliability of pH measurements requires establishment of a metrological hierarchy including an uncertainty budget for calibration that links the pH measured in the sample to an internationally agreed and stated reference. For pH, this reference is the primary measurement of pH. A traceability chain can be established that links field measurements of pH to primary buffer solutions that are certified using this primary method. This allows the user in the field to estimate the measurement uncertainty of the measured pH data. As the realization of the primary measurement is sophisticated and time-consuming, primary standards are generally realized at national metrology institutes. A number of potentiometric methods are suitable for the determination of the pH of reference buffer solutions by comparison with the primary standard buffers. The choice between the methods should be made according to the uncertainty required for the application. For reference buffer solutions that have the same nominal composition as the primary standard, the differential potentiometric cell, often called the Baucke cell, is recommended.  相似文献   

7.
The fluorescence property of fluorescein isothiocyanate (FITC) in acid-alkaline medium was studied by spectrofluorimetry. The characteristic of FITC response to hydrogen ion has been examined in acid-alkaline solution. A novel pH chemical sensor was prepared based on the relationship between the relative fluorescence intensity of FITC and pH. The measurement of relative fluorescence intensity was carried out at 362 nm with excitation at 250 nm. The excellent linear relationship was obtained between relative fluorescence intensity and pH in the range of pH 1-5. The linear regression equation of the calibration graph is F = 66.871 + 6.605 pH (F is relative fluorescence intensity), with a correlation coefficient of linear regression of 0.9995. Effects of temperature, concentration of FITC on the response to hydrogen ion had been examined. It was important that this chemical sensor was long lifetime, and the property of response to hydrogen ion was stable for at least 70 days. This pH sensor can be used for measuring pH value in water solution. The accuracy is 0.01 pH unit. The results obtained by the pH sensor agreed with those by the pH meter. Obviously, this pH sensor is potential for determining pH change real time in biological system.  相似文献   

8.
The effect of pH on the oxidation of individual PSP toxins using both periodate and peroxide oxidations was studied. It was found that the optimum pH for individual toxins varied considerably. For periodate oxidations, pH 8.2 produced the maximum yield of fluorescent products for neosaxitoxin and GTX1/GTX4 while the non-hydroxylated toxins (saxitoxin, GTX2/GTX3, decarbamoyl saxitoxin, GTX5) showed optimum pHs from about pH 10-11.5. Neosaxitoxin and GTX1/GTX4 did not produce significant fluorescent oxidation products with peroxide oxidation at any of the pHs studied (pH 8.2-12.8). The non-hydroxylated toxins all showed optimum pHs above pH 12 with peroxide oxidation. Yields of fluorescent products of these toxins decreased substantially at pHs below pH 12. Neosaxitoxin and GTX1/GTX4 each produced three product peaks at pH 8.2 with periodate oxidation. There was no pH where these toxins produced predominantly a single oxidation product. Decarbamoyl saxitoxin always produced two oxidation products with both oxidation reactions at the pHs studied. However, the relative yields of the products changed with pH. At low pH the second eluting product predominated, while at higher pH values the first eluting product predominated. This pattern was observed for both oxidation reactions. The other non-hydroxylated toxins produced mainly single unique products with both oxidation reactions over the pH range studied. No single pH was found optimum for the oxidation of both hydroxylated and non-hydroxylated toxins without a significant compromise in yield of oxidation products. This has implications for the post column oxidation liquid chromatographic methods, since small changes in pH of the post column oxidant can both positively and negatively affect the yields of oxidation products of toxin mixtures leading to increased error in the subsequent quantitation of these compounds.  相似文献   

9.
Traceability is a prerequisite for the comparability and uniformity of measurements. Although pH-measurements are carried out on a large scale in laboratory and industry, the problems involved in the traceability of pH values have not adequately been solved in the past. The comparability of pH measurements is limited, among other parameters, by the accuracy of the pH values of the standard buffer solutions used to calibrate the pH meter-electrode assemblies. The measured pH(X) value must be traceable to primary standard pH(PS) values through an unbroken chain of comparisons, all values having stated uncertainties. A new primary standard measurement device for pH is used to certify primary pH reference materials from which these secondary reference materials can be derived.  相似文献   

10.
The effect of pH on the stability and overall catalytic activity of half-reduced Pseudomonas cytochrome c peroxidase was studied over the pH range 3.5-8. The stability of the enzyme as deduced from 40 s incubation experiments is virtually unaffected by pH. However, there is a bell-shaped pH dependence for the overall catalytic reaction using H2O2 as oxidizing substrate and cytochrome c-551 as reducing substrate with maximum turnover rate of pH 6. The effects of pH on (1) rate of reduction of the totally ferric enzyme by reduced azurin over the pH range 3.5-8 and (2) the rate of compound I formation from the half-reduced enzyme and hydrogen peroxide over the pH range 4-8 were also investigated. The reduction reaction rate also appears bell-shaped with optimum rate at pH 5.6. The rate of compound I formation is virtually pH independent above pH 5 but drops dramatically as the pH is lowered from 5 to 4. The influence of an ionization with apparent pKa value of 4.4 is implicated in compound I formation. This enzyme acid group must be deprotonated for compound I formation to occur suggesting the importance of base catalysis.  相似文献   

11.
We report the first in vitro selection of DNA nanostructures that switch their conformation when triggered by change in pH. Previously, most pH‐active nanostructures were designed using known pH‐active motifs, such as the i‐motif or the triplex structure. In contrast, we performed de novo selections starting from a random library and generated nanostructures that can sequester and release Mipomersen, a clinically approved antisense DNA drug, in response to pH change. We demonstrate extraordinary pH‐selectivity, releasing up to 714‐fold more Mipomersen at pH 5.2 compared to pH 7.5. Interestingly, none of our nanostructures showed significant sequence similarity to known pH‐sensitive motifs, suggesting that they may operate via novel structure‐switching mechanisms. We believe our selection scheme is general and could be adopted for generating DNA nanostructures for many applications including drug delivery, sensors and pH‐active surfaces.  相似文献   

12.
Ito S  Hachiya H  Baba K  Eto M  Asano Y  Wada H 《Talanta》1996,43(9):1421-1428
The best reproducible technology of pH measurement for precise pH buffer solutions regulated by Japanese Industrial Standards (JIS) was studied. A pH meter was devised with a high resolution of +/- 0.0001 pH. An 18-bit analog-to-digital converter is used, one-bit resolution corresponding to 0.0019 mV (ca. 0.000032 pH) against an input electrode potential +/- 500 mV. Digital data were treated smoothly for some types of noise, a reproducibility of +/- 0.0002 pH being obtained with a potentiometer. A flow cell was devised to attain temperature control within +/- 0.03 degrees C and air-tight measurement prevented contamination with carbon dioxide. Also, the flow cell has a structure such that potassium chloride (KCl) inner solution effused from a ceramic junction of the reference electrode designed so as not to touch the glass membrane. A combination pH electrode (a glass electrode and a reference electrode) was assembled to minimize the dead volume of sample solution. This highly sensitive pH measuring system, consisting of a pH meter, a flow cell, a combination pH electrode, a circulating water thermostat and a peristaltic pump, was used for the certification of pH standard solutions in Japanese metrological law. The performance of this system was within +/- 0.0006 pH reproducibility and 20-30 min response time (5 min within +/- 0.0002 pH) at a sample flow rate of 3 ml min (-1).  相似文献   

13.
Composite microparticle drug delivery systems based on chitosan, alginate and pectin with improved pH sensitivity were developed for oral delivery of protein drugs, using bovine serum albumin (BSA) as a model drug. The composite drug-loaded microparticles with a mean particle size less than 200 μm were prepared by a convenient shredding method. Since the microparticles were formed by tripolyphosphate cross-linking, electrostatic complexation by alginate and/or pectin, as well as ionotropic gelation with calcium ions, the microparticles exhibited an improved pH-sensitive drug release property. The in vitro drug release behaviors of the microparticles were studied in simulated gastric (pH 1.2 and pH 5.0), intestinal (pH 7.4) and colonic (pH 6.0 and pH 6.8 with enzyme) media. For the composite microparticles with suitable compositions, the releases of BSA at pH 1.2 and pH 5.0 could be effectively sustained, while the releases at pH 7.4, pH 6.8 and pH 6.0 increased significantly, especially in the presence of pectinase. These results clearly suggested that the microparticles had potential for site-specific protein drug delivery through oral administration.  相似文献   

14.
The concentration of iodate in seawater samples was determined at various pH values using differential pulse polarography (DPP). The sensitivity for the iodate determination decreased rapidly below pH 7 and above pH 9. The decrease below pH 7 may be caused by conversion of iodate to iodide, followed by the successive formation of I2 and I3 . The decrease above pH 9 is probably due to the combination of iodate and hydroxide. Theoretical calculations have demonstrated that the optimum pH for iodate determination is above pH 7.4 for Po2 = 0.101 Pa.  相似文献   

15.
A new NMR chemical shift standard and pH indicator, difluorotrimethylsilanylphosphonic acid (DFTMP), is described, and the utility of this reagent is demonstrated for in situ determination of pH in complex biofluids. The pH dependence of this reagent allows accurate in situ determination of aqueous solution pH to within an RMSE of 0.02 pH units over a pH range of 5 to 8. Advantages of this reagent over previously described pH-sensitive components include (1) lack of metal binding affinity, (2) minimal disturbance of endogenous spectral regions, and (3) the potential to function as a multinuclear pH indicator and chemical shift reference point for 19F, 1H, and 31P nuclei. This reagent will be generally useful for NMR experiments on biological systems where the pH needs to be accurately measured at the moment of data acquisition.  相似文献   

16.
《European Polymer Journal》1986,22(7):577-583
Ionization and solubility of silicic acid with variation of pH and concentration of silicic acid are studied by potentiometric measurements. Two characteristic points appear on titration plots: the first point occurs at pH = 3 with formation of the ionized silicic acid; the second at pH = 7 is interpreted as revealing monomeric species. Diverse species of ionized silicic acid are in sols between pH = 3 and 7; the sols contain the smallest species of polymer for pH < 6 and show an optimum of polymerization for pH ≥ 6.  相似文献   

17.
The rates and products of the reactions of (+/-)-7beta,8alpha-dihydroxy-9beta,10beta-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (1) and (+/-)-7beta,8alpha-dihydroxy-9alpha,10alpha-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (2) in water and dioxane-water mixtures have been determined over a pH range wider than that of earlier studies. This study provides additional insight on the mechanisms of the pH-independent reactions of 1 and 2. The rate profile for reaction of 1 shows acid-catalyzed hydrolysis at pH <5, a rate plateau at pH 5-9.5, a negative inflection at pH 10-11.5, and a rate increase at pH >11.5. The rate decrease between pH 10 and pH 11.5 is accompanied by a decrease in the yield of tetrols from 60% (pH 8) to 29% (pH 11.2) and is interpreted to be the result of a partial change in mechanism brought about by attack of hydroxide ion acting as a base to deprotonate a carbocation intermediate and regenerate 1 at pH >10, thus reducing the contribution of the pathway for tetrol formation in which water attacks the carbocation. The rate profile for the reaction of 2 exhibits only a single rate plateau at intermediate pH, along with increases in rate at low and high pH because of second-order reactions of 2 with H+ and HO-, respectively. The lack of a rate depression at pH >10 and the product studies for the reaction of 2 in dilute sodium azide solutions suggest that the tetrol-forming reactions of the pH-independent reaction of 2 are concerted or near-concerted.  相似文献   

18.
P G Righetti  C Tonani 《Electrophoresis》1991,12(12):1021-1027
While in the companion paper (Tonani, C. & Righetti, P. G., Electrophoresis 1991, 12, 1011-1021) we gave the general outline of our new computer program, immobilized pH gradients (IPG) simulator, able to simulate and optimize linear pH gradients for isoelectric focusing in immobilized pH gradients, in the present report we extend the application of such a program to: (i) convex exponential gradients, (ii) logarithmic and (iii) polynomial gradients. Such gradients are meant to give equal space to protein spots in complex protein mixtures (e.g., cell lysates, biological fluids) and follow the statistical distribution of protein pI values along the pH axis. They will prove of fundamental importance in two-dimensional maps, both because they optimize the spreading of spots in the two-dimensional plane and because of the excellent reproducibility of immobilized pH gradients. The following concave exponential recipes are given: pH 3-8, pH 3-9, pH 3-10, pH 3-11, pH 4-7, pH 4-8, pH 4-9, pH 4-10, pH 4-11, pH 5-8, pH 5-9, and pH 5-10, as well as the most extended pH 2.5-11 interval. Two interesting logarithmic gradients are described: pH 3-6 and pH 3-7 and one sigmoidal (derived with a polynomial of 5th degree): pH 3-11.  相似文献   

19.
Many biological and chemical systems involve acid-base equilibria and thus depend critically on the pH of the solution. Small fluctuations of pH must be corrected by the addition of an acid or base to maintain the pH at the required optimum level during the fermentation process. The effect of pH control on the growth ofKluveromyces fragilis, used for the production of single-cell protein from cheese whey, was investigated. Maintaining the pH at 4.5 was found essential for the survival of the yeast. Without pH control, the pH of the medium continued to rise, resulting in the death and/or sporulation of the yeast cells. Diauxic growth was observed, caused by the growth of contaminant bacteria when the pH was not controlled.  相似文献   

20.
Second harmonic generation (SHG) spectroscopy was used to characterize the pH-dependent electrostatic charging behavior of (0001) and (102) crystallographic surfaces of corundum (alpha-Al2O3) single-crystal substrates. The pH value of the point of zero charge (pH(pzc)) for each surface was determined by monitoring the SH response during three consecutive pH titrations conducted with 1, 10, and 100 mM NaNO3 carbonate-free aqueous solutions. The crossing point of the three titration curves, which corresponds to the pH(pzc), occurs at pH 4.1 +/- 0.4 for the (0001) surface and pH 5.2 +/- 0.4 for the (102) surface. SHG measurements that were recorded as a function of NaNO3 concentration at fixed pH values were found to corroborate the pH(pzc) values identified in the pH titrations. A comparison of the SHG results with surface protonation constants calculated using a simple electrostatic model suggests that surface relaxation and bonding changes resulting from surface hydration do not account for differences between experimental observations and model predictions. The measured pH(pzc) values for the alpha-Al2O3 single-crystal surfaces are significantly more acidic than published values for Al-(hydr)oxide particles which typically range from pH 8 to 10. This discrepancy suggests that the charging behavior of Al-(hydr)oxide particles is determined by surface sites associated with defects assuming that differences in surface acidity reflect differences in the coordination environment and local structure of the potential-determining surface groups.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号