首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Gholivand MB  Nozari N 《Talanta》2001,54(4):597-602
Poly(vinyl chloride) membrane electrode, that is highly selective and sensitive to Cu(II) ions, was developed by using 2,2'-dithiodianiline and dibutyl phthalate as carrier and plasticizer, respectively. The electrode exhibits good potentiometric response for Cu(II) over a wide concentration range (5.0x10(-2)-7.0x10(-7) mol l(-1)) with Nernstian slope of 30+/-1 mV per decade. The response time of the electrode is 10 s and it has been used for a period of one month and exhibits good selectivity towards Cu(2+) in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb(2+), Cd(2+) and Fe(+2) which are known to interfere with many other copper electrodes.  相似文献   

2.
Qiu S  Xie L  Gao S  Liu Q  Lin Z  Qiu B  Chen G 《Analytica chimica acta》2011,707(1-2):57-61
Herein, a novel sensitive electrochemical sensor for copper(II) based on Cu(I) catalyzed alkyne-azide cycloaddition reaction (CuAAC) is described. The catalyst of Cu(I) species is derived from electrochemical reduction of Cu(II) through bulk electrolysis (BE) with coulometry technique. The propargyl-functionalized ferrocene (propargyl-functionalized Fc) is covalently coupled onto the electrode surface via CuAAC reaction and forms propargyl-functionalized Fc modified gold electrode, which allows a good and stable electrochemical signal. The change of current at peak (dI), detected by differential pulse voltammetry (DPV), exhibits a linear response to the logarithm of Cu(II) concentration in the range of 1.0×10(-14)-1.0×10(-9) mol L(-1). It is also found that the proposed sensor has a good selectivity for copper(II) assay even in the presence of other common metal ions. Additionally, the proposed method has been applied to determine copper(II) in the dairy product (yoghurt) with satisfactory results.  相似文献   

3.
A novel Schiff base designated as 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole was synthesized and characterized. A polyvinyl chloride-membrane potentiometric copper(II)-selective sensor was prepared by using the synthesized 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole compound. The prepared polyvinyl chloride-membrane copper(II)-selective sensor exhibited very good selectivity and sensitive potentiometric response towards copper(II) ions compared to a wide variety of other cations. The sensor had a fast response time of <5?s, and showed a linear Nerstian behavior to copper(II) ions over a wide concentration range from 1.0?×?10?5 to 1.0?×?10?1 mol L?1 with a slope of 29.2?±?0.7 and correlation coefficient of 0.9998. The prepared polyvinyl chloride-membrane copper(II)-selective sensor was used for 14 weeks without any significant change in its potentiometric response. The potentiometric response of the developed sensor was highly repeatable. Additionally, the developed sensor was used as an indicator electrode for the potentiometric titration of copper(II) ion with ethylenediaminetetraacetic acid. The sensor was also successfully applied to the direct determination of copper(II) ions in tap water, river water, and dam water samples.  相似文献   

4.
The cooperative action of multiple Cu(II) nuclear centers is shown to be effective and selective in the hydrolysis of 2'-5' and 3'-5' ribonucleotides. Reported herein is the specific catalysis by two trinuclear Cu(II) complexes of L3A and L3B. Pseudo first-order kinetic studies reveal that the L3A trinuclear Cu(II) complex effects hydrolysis of Up(2'-5')U with a rate constant of 28 x 10(-)(4) min(-)(1) and Up(3'-5')U with a rate constant of 0.5 x 10(-)(4) min(-)(1). The hydrolyses of Ap(3'-5')A and Ap(2'-5')A proceed with rate constants of 24 x 10(-)(4) min(-)(1) and 0.5 x 10(-)(4) min(-)(1) respectively. The L3A trinuclear Cu(II) complex demonstrates high specificity for Up(2'-5')U and Ap(3'-5')A. Similar studies with the more rigid L3B trinuclear Cu(II) complex shows no selectivity and yields lower rate constants for hydrolysis. The selectivity observed with the L3A ligand is attributed to the geometry of the ligand-bound diribonucleotide which ultimately dictates the proximity of the attacking hydroxyl and the phosphoester to a Cu(II) center for activation and subsequent hydrolysis.  相似文献   

5.
A new optical chemical sensor has been developed for the selective determination of copper(II) ions in aqueous solutions. The reversible sensing system was prepared by incorporating 1-hydrpxy-2-(prop-2'-enyl)-4-(prop-2'-enyloxy)-9,10-anthraquinone (AQ) as a neutral Cu2+-selective fluoroionophore in the plasticized PVC membrane with potassium tetrakis(p-chlorophenyl borate) as an anionic additive. The response of the sensor is based on the fluorescence quenching of AQ by Cu2+ ions. At a pH 5.5, the proposed sensor displays a calibration response for Cu2+ over a wide concentration rang of 1.0 x 10(-2) to 1.0 x 10(-6) M, with a relatively fast response of less than 40 s. In addition to high stability and reproducibility, the sensor shows a unique selectivity towards Cu2+ ion with respect to common co-existing cations. The proposed fluorescence optode was applied successfully to the determination of copper(II) in black tea samples.  相似文献   

6.
Hulanicki A  Lewenstam A 《Talanta》1976,23(9):661-665
The diffusion-layer model for the chalcocite (Cu(2)S) membrane electrode is discussed. It is equivalent to a simpler model based on exchange reactions at the electrode surface. The chalcocite is sensitive to copper(I) and copper(II) ions and the theoretically predicted response is in good agreement with experimental data. The membrane is a conductor, but this does not significantly affect its function as an ion detector. The limitation of the electrode is the membrane solubility as shown when Cu(II) ions in contrast to copper(I) ions are strongly complexed.  相似文献   

7.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

8.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

9.
The preparation of a lead-selective electrode based on bis(1'-hydroxy-2'-acetonaphthone)-2,2'-diiminodiethylamine (L) as sensing material is reported. The plasticized PVC membrane containing 30% PVC, 67% ortho-nitrophenyloctylether (NPOE) and 3% ionophore L was directly coated on a graphite rod. This electrode exhibits a nearly Nernstian slope of 27.8+/-0.2 mV decade(-1) over a concentration range 10(-6)-10(-2) M with a detection limit of 4.0 x 10(-7) M. The response time of the electrode was found to be <20 s. The potential of the sensor was independent on pH variations in the range 5-7. The selectivity of the electrode towards lead ions over Na+, K+, Ag+, Ca2+, Sr2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, La3+, Sm3+ and Er3+ ions was investigated. The prepared electrode was successfully used as an indicator for titration of a lead solution with a standard solution of EDTA. The applicability of the sensor for Pb2+ measurement in various synthetic and real samples has been also demonstrated.  相似文献   

10.
A novel optical sensor has been proposed for sensitive determination of Cu(II) ion in aqueous solutions. The copper sensing membrane was prepared by incorporating Qsal (2-(2-hydroxyphenyl)-3H-anthra[2,1-d]imidazole-6,11-dione) as ionophore in the plasticized PVC membrane containing tributyl phosphate (TBP) as plasticizer. The membrane responds to Cu(II) ion by changing color reversibly from yellow to dark red in acetate buffer solution at pH 4.0. The proposed sensor displays a linear range of 6.3 × 10?7?1.00 × 10?4 M with a limit of detection of 3.3 × 10?7 M. The response time of the optical sensor was about 3?C5 min, depending on the concentration of Cu(II) ions. The selectivity of the optical sensor to Cu(II) ions in acetate buffer is good. The sensor can readily be regenerated by hydrochloric acid (0.1 M). The optical sensor is fully reversible. The proposed optical sensor was applied to the determination of Cu(II) in environmental water samples.  相似文献   

11.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

12.
Three new compounds, CuL, CuL', and Cu(2)O(2)L'(2) (H(2)L = 3'-[(E)-{[(1S,2S)-2-aminocyclohexyl]imino}methyl]-4'-hydroxy-4-biphenylcarboxlic acid, H(2)L' = 3'-[(E)-{[(1S,2S)-2-aminocyclohexyl]imino}methyl]-4'-hydroxy-5'-nitro-4-biphenylcarboxlic acid, H(2)L' = 3'-(N,N-dimethylamino methyl)-4'-hydroxy-4-biphenylcarboxlic acid), were selectively synthesized through a controlled in situ ligand reaction system mediated by copper(II) nitrate and H(2)L. Selective nitration was achieved by using different solvent mixtures under relatively mild conditions, and an interesting and economical reductive amination system in DMF/EtOH/H(2) O was also found. All crystal structures were determined by single-crystal X-ray diffraction analysis. Both CuL and CuL' display chiral 1D chain structures, whereas Cu(2)O(2)L'(2) possesses a structure with 13×16?? channels and a free volume of 41.4?%. The possible mechanisms involved in this in situ ligand-controlled reaction system are discussed in detail.  相似文献   

13.
《Analytical letters》2012,45(13):2611-2629
ABSTRACT

New potentiometric membranesensorsresponsive to Pb(II) have been developed. The membrane sensors are based on three different 9, 10-anthraquinone derivatives. The electrode based on 1, 4-bis (prop-21-enyloxy)-9, 10-anthraquinone exhibits a good Nernstian response for Pb(II) ions over a wide concentration range (2.5×10?6 - 1.0×10?2 M) with a slope of 29.8 mV decade?1. Detection limit is 1.5×10?6 M. The response time of the sensor is 15s and the useful working pH range is 4.7-6.8. The membrane can be used for more than 4 months without any considerable divergence in potentials. The electrodes revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of lead ions (with sulfate and oxalate ions), and for the determination of lead in waste waters.  相似文献   

14.
An attempt has been made to develop a highly selective Cu2+-ion selective electrode based on a poly(vinyl chloride) based sensor using 1,2,5,6,8,11-hexaazacyclododeca-7,12-dione-2,4,8,10-tetraene as ionophore with 61.5% DBP in the presence of 29% PVC, 4.5% ionophore and 5% NaTBP as an anion excluder. The sensor exhibits a near Nernstian potential response of 29.5 +/- 0.3 mV per decade over a wide concentration range (2.0 x 10(-7) - 1 x 10(-1) M) with a detection limit of 8.1 x 10(-8) M between pH 3 - 11 with a fast response time of < 5 s. The selectivity coefficient values, as determined by the matched potential method (MPM), indicate excellent selectivity for Cu(II) ions over a large number of ions. The proposed sensor exhibits an adequate shelf life (4 - 5 months) with good reproducibility. The quantification of Cu(II) in electroplating wastewater and various brands of Indian tea was successfully achieved using the proposed sensor.  相似文献   

15.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

16.
Jain AK  Gupta VK  Singh LP  Raisoni JR 《Talanta》2005,66(5):1355-1361
Acetylacetone, ethylacetoacetate and salicyldehyde, are reported to form chelates with copper of high stability as compared to other metals. Therefore, PVC based membranes of bis[acetylacetonato] Cu(II) (A), bis[ethylacetoacetate] Cu(II) (B) and bis[salicyldehyde] Cu(II) (C) have been investigated as copper(II) selective sensors. The addition of sodium tetraphenylborate and various plasticizers, viz., DOS, TEHP, DOP, DBP and TBP have been found to substantially improve the performance of the sensors. The membranes of various compositions of the three chelates were investigated and it was found that the best performance was obtained for the membrane of composition A (1%): PVC (33%): TBP (65%): NaTPB (1%). The sensor shows a linear potential response to Cu(II) over wide concentration range 2.0 × 10−6 to 1.0 × 10−1 M (detection limit 0.1 ppm) with Nernstian compliance (29.3 mV decade−1 of activity) between pH 2.6 and 6.0 with a fast response time of 9 s. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate excellent selectivity for Cu2+ ions over interfering cations. The sensor exhibits adequate shelf life (3 months) with good reproducibility (S.D. ±0.2 mV). The sensor has been used in the potentiometric titration of Cu2+ with EDTA. The utility of the sensor has been tested by determining copper in vegetable foliar and multivitamin capsule successfully.  相似文献   

17.
A copper(II) ion-selective electrode based on a recently synthesized 2-quinolyl-2-phenylglyoxal-2-oxime (phenylglyoxal-alpha-monoxime) has been developed. The PVC-based membrane containing phenylglyoxal-alpha-monoxime, dibutyl phthalate as plasticizer, and sodium tetraphenylborate as anion excluder and membrane modifier, was directly coated on the surface of a platinum-wire electrode. The response of the electrode was linear with a near-Nernstian slope of 28.2 mV decade(-1) within the Cu2+ ion concentration range 1x10(-6)-1x10(-1) mol x L(-1). The response time for the proposed electrode to achieve a 95% steady potential for Cu2+ concentrations ranging from 1x10(-1) to 1x10(-6) mol x L(-1) is between 10 and 50 s, and the electrode is suitable for use within the pH range of 3 to 6.5. The electrode has a detection limit of 5x10(-7) mol x L(-1) Cu2+ and its selectivity relative to several alkali, alkaline earth, transition, and heavy metal ions was good. The coated-wire electrode could be used for at least two months without a considerable alteration of its potential. Applications of the electrode for determination of copper in milk powder samples and as an indicator electrode for potentiometric titration of Cu2+ ion using EDTA are reported.  相似文献   

18.
Preparation, characterization, and applications of a 1,10-phenanthrolinium cation (phenH(+))-sensitive potentiometric sensor are described. The sensor incorporates a liquid polymeric membrane consisting of phenH-tetraphenylborate, nitrophenyloctyl ether, and poly(vinyl chloride) as ion exchanger, plasticizer, and polymeric support, respectively. The sensor exhibits a fast and Nernstian response to phenH(+) over the concentration range of 6 x 10(-6)-2 x 10(-4) M with a monovalent cationic slope of 58.0+/-0.5 mV/log[phenH(+)] in acetate buffer of pH 4.2. The sensor is successfully applied to the monitoring of the potentiometric titration of Hg(II) and Cu(II) ions with phen solution in the presence of citrate and acetate buffers of pH 4.2, respectively. Sharp inflection breaks (90-180 mV) at 1:1 (metal:phen reaction) are obtained in the presence of chloride and thiocyanate background. This stoichiometry is explained by the formation of insoluble [HgCl(2)(phen)], [Hg(SCN)(2)(phen)], and [Cu(SCN)(2)(phen)] complexes. Optimization of each titration and the effect of foreign ions are evaluated. The method offers the advantages of adequate sensitivity, accuracy, and selectivity for the determination of mercury and copper in pharmaceutical, rock, and tea samples. The results are in good agreement with those obtained using the standard atomic absorption spectrometric and United States Pharmacopeial methods.  相似文献   

19.
The preparation of an ion-selective electrode by chemical treatment of copper wire and its application for the measurements of copper (II) and iodide ions is described. The proposed reaction mechanism at the sensing surface, which explains the response of the electrode to Cu2+ and iodide ions, is discussed. The prepared electrode was suitable for direct potentiometric measurements of iodide and copper (II) in batch experiments down to concentrations of 1 × 10–5 mol L–1. A tubular electrode, prepared in the same way, may be used as a potentiometric sensor in a flow-injection analysis for Cu (II) and/or iodide determinations.  相似文献   

20.
A conducting polymer modified electrode based on the incorporation of 4,5-dihydroxy-3-(p-sulfophenylazo)-2,7-naphthalene disulfonic acid, SPADNS, as an anionic complexing ligand into polypyrrole film during electropolymerization was prepared. The electroanalysis of copper(II) in this modified electrode was achieved by medium exchange and differential pulse voltammetry. Copper ions were accumulated from ammonia buffer on the electrode surface by the formation of a chemical complex at open circuit. The resulting electrode with complexed Cu(2+) was then transferred to an acetate buffer and subjected to anodic stripping voltammetry. The analytical performance was evaluated and, finally, linear calibration graphs were obtained in the concentration range of 2 - 250 ng ml(-1) for Cu(II). The detection limit was found to be 1.1 ng ml(-1) and RSD was obtained at 3.1 and 1.9% for two different concentrations. Many coexisting metal ions had little or no effect on the determination of copper. The developed method was applied to Cu(II) determination in natural water and human hair samples. Also, the rapid and convenient regeneration of electrode allows the use of a single modified electrode in multiple analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号