首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(11):1588-1602
Abstract

This article describes validated high-performance liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of alprazolam (ALZ) and sertraline (SER) in pure powder and tablet formulation. The HPLC separation was achieved on a Nucleosil C18 column (150 mm long, 4.6 mm i.d., and 5-µm particle size) using acetonitrile and phosphate buffer (50 + 50 v/v), pH 5.5, as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60 F254 using acetone/toluene/ammonia (6.0:3.0:1.0, v/v/v) as the mobile phase. Quantification with the HPLC method was achieved with ultraviolet (UV) detection at 230 nm over the concentration range 3–18 µg/mL for both drugs with mean recovery of 101.86 ± 0.21 and 100.57 ± 0.31% for ALZ and SER, respectively. Quantification in HPTLC was achieved with UV detection at 230 nm over the concentration range of 400–1400 ng/spot for both drugs with mean recoveries of 101.32 ± 0.15 and 100.38 ± 0.51% for ALZ and SER, respectively. These methods are rapid, simple, precise, sensitive, and are applicable for the simultaneous determination of ALZ and SER in pure powder and formulations.  相似文献   

2.
This paper describes validated high-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC) methods for the simultaneous estimation of pantoprazole (PANT) and domperidone (DOM) in pure powder and capsule formulations. The HPLC separation was achieved on a Phenomenex C18 column (250 mm id, 4.6 mm, 5 pm) using 0.01 M, 6.5 pH ammonium acetate buffer-methanol-acetonitrile (30 + 40 + 30, v/v/v, pH 7.20) as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol (60 + 40, v/v) as the mobile phase. Quantification was achieved with ultraviolet (UV) detection at 287 nm over the concentration range 400-4000 and 300-3000 ng/mL with mean recovery of 99.35+/-0.80 and 99.08+/-0.57% for PANT and DOM, respectively (HPLC method). Quantification was achieved with UV detection at 287 nm over the concentration range 80-240 and 60-180 ng/spot with mean recovery of 98.40+/-0.67 and 98.75+/-0.71% for PANT and DOM, respectively (HPTLC method). These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of PANT and DOM in pure powder and capsule formulations.  相似文献   

3.
Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The fi rst method was based on reversed-phase high-performance liquid chromatography (HPLC), on a Lichrosorb RP C(18) column using water:acetonitrile:phosphoric acid (76:24:0.5 v/v/v) as the mobile phase at a fl ow rate of 1.5 mL min(-1) at ambient temperature. Quantification was achieved with UV detection at 229 nm over a concentration range of 10-500 micro g mL(-1) with mean percentage recovery of 99.71 +/- 0.55. The method retained its accuracy in presence of up to 90% of ZIP degradation products. The second method was based on TLC separation of ZIP from its degradation products followed by densitometric measurement of the intact drug spot at 247 nm. The separation was carried out on aluminium sheet of silica gel 60 F(254) using choloroform:methanol:glacial acetic acid (75:5:4.5 v/v/v) as the mobile phase, over a concentration range of 1-10 micro g per spot and mean percentage recovery of 99.26 +/- 0.39. Both methods were applied successfully to laboratory prepared mixtures and pharmaceutical capsules.  相似文献   

4.
Two simple, specific, sensitive, accurate and precise stability indicating methods were described for quantitative determination of the anthelmintics drug Niclosamide. The first method was high performance liquid chromatographic with the use of a reversed phase hibarR C-18 column (250 mm × 4.66 mm, 5 μm) and mobile phase of methanol: 1 mM ammonium phosphate buffer (85:15 v/v) at a flow rate of 1.2 mL/min. The retention time of drug was found to be 6.45 ± 0.02 min. Quantification of drug was achieved with diode array detection (DAD) at 332 nm. Linear calibration curve was obtained in concentration range 0.01–100 μg/mL with r2 value of 0.999. The limit of detection and limit of quantification were found to be 0.048 μg/mL and 0.01 μg/ml respectively. The second method involved a high performance thin layer liquid chromatographic. Chromatographic separation was carried out with precoated silica gel G60 F254 aluminum sheets using toluene:ethyl acetate (7:3% v/v) as a mobile phase. Linearity of proposed method was found to be 200–700 ng/band at 332 nm with retention factor of 0.59 and r2 value of 0.998. The limit of detection and limit of quantification were found to be 36.21 ng/band and 109.7 ng/band respectively. Both the developed methods were successfully validated as per International Conference on Harmonization guideline (ICH). Niclosamide was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time. Stress samples were successfully assayed by developed high performance liquid chromatographic and high performance thin layer liquid chromatographic method. Statistically analysis proves that there were no statistical significant differences between two developed methods.  相似文献   

5.
An HPLC method was developed and validated for the determination of butamyrate citrate. The HPLC separation was achieved on a diol column (300 × 4.6 mm) packed with 5.0 μm particle size using a mobile phase of ammonium acetate buffer (pH = 6.5) and methanol (750:250, v/v) at a flow rate of 1.4 ml min?1. The UV detector was operated at 225 nm. The method was validated for specificity, linearity, precision, accuracy and robustness. The retention time was 5.9 min. The proposed method provided linear responses within the concentration range 75–225 μg ml?1 with LOD and LOQ values of 0.69 and 2.29 μg ml?1, respectively. Correlation coefficient (r) of the regression equation was 0.9999. The method was found to be precise, accurate, and reproducible.  相似文献   

6.
High efficiency and less run time are the basic requirements of high-speed chromatographic separations. To fulfill these requirements, a new separation technique, ultra-performance liquid chromatography (UPLC), has shown promising developments. A rapid, specific, sensitive, and precise reverse-phase UPLC method is developed for the determination of nabumetone in tablet dosage form. In this work, a new isocratic chromatographic method is developed. The newly developed method is applicable for assay determination of the active pharmaceutical ingredient. The chromatographic separation is achieved on a Waters Acquity BEH column (100 mm, i.d., 2.1 mm, 1.7 μm) within a short runtime of 2 min using a mobile phase of 5 mM ammonium acetate-acetonitrile (25:75, v/v), at a flow rate of 0.3 mL/min at an ambient temperature. Quantification is achieved with photodiode array detection at 230 nm, over the concentration range of 0.05-26 μg/mL. Forced degradation studies are also performed for nabumetone bulk drug samples to demonstrate the stability-indicating power of the UPLC method. Comparison of system performance with conventional high-performance liquid chromatography is made with respect to analysis time, efficiency, and sensitivity. The method is validated according to the ICH guidelines and is applied successfully for the determination of nabumetone in tablets.  相似文献   

7.
A derivative UV (D-UV) spectrophotometric method was developed for the determination of Levothyroxine Sodium (L-T4) in tablets of different doses. Quantification was performed using the second derivative of the absorption spectrum at 253 nm (2D253) in methanol: water (50: 50; v/v) (pH 11.2). The method was validated and compared with an HPLC procedure carried out using a RP-18 column (125 × 4 mm, 5 μm) and methanol: phosphoric acid (0.1%) (70: 30, v/v) (pH 3) as mobile phase. Flow rate was set at 1.5 mL/min, and detection was performed at 225 nm. The proposed D-UV method was linear in the range 3.0–40.0 μg/mL with an appropriate precision and accuracy, and it was selective for the drug under study. On the other hand, results obtained by 2D253 analysis were similar to those obtained by HPLC, with no statistically significant differences between them. Therefore, it was concluded that the developed method is suitable for the determination of L-T4 in tablets at the tested doses.  相似文献   

8.
Yu L  Ye H  Zheng L  Chen L  Chu K  Liu X  Xu X  Chen G 《Electrophoresis》2011,32(2):218-222
A new method for separation and determination of amygdalin and its epimer (neoamygdalin) in the epimerization of amygdalin by MEEKC is proposed. For the chiral separation of amygdalin and neoamygdalin, a running buffer composed of 80 mM sodium cholate, 5.0% v/v butan‐1‐ol, 0.5% v/v heptane and 94.5% v/v 30 mM Na2B4O7 buffer (pH 9.00) is proposed. Under optimum conditions, the basic separation of amygdalin and neoamygdalin can be achieved within 7 min. The calibration curve for amygdalin showed excellent linearity in the concentration range of 20–1000 μg/mL with a detection limit of 5.0 μg/mL (S/N=3). The epimerization rate constant of amygdalin in basic microemulsion was first determined by monitoring the concentration changes of amygdalin, and the epimerization rate constant of amygdalin was found to be 2×10?3 min?1 at 25°C under the above optimum microemulsion conditions.  相似文献   

9.
In this study, a rapid and reliable micellar electrokinetic capillary chromatography (MECC) method has been developed and validated for the separation and quantification of 15 nucleosides and nucleobases in a kind of marine medicinal animal Anthopleura lanthogrammica Berkly. Factors such as micelle concentration, pH, concentration of buffer, etc. were investigated in order to obtain the optimum conditions for the separation. The optimized separation procedure employed 25 mM disodium hydrogen phosphate buffer containing 70 mM sodium dodecyl sulfate (SDS) at pH 8.7 as background electrolyte, 25°C of capillary temperature and 20 kV of separation voltage. UV detection was at 260 nm and injection was hydrodynamic at 50 mbar for 3 s. The whole analysis was completed within 13 min. The relative standard deviations (RSDs) of the peak areas for method precision ranged from 1.4 to 7.6%, and the recovery was between 80.2 and 112.9%. The limit of detection (LOD) for 15 nucleosides and nuleobases was between 0.25 and 0.75 μg/mL. According to the evaluation study, the method was shown to be precise, accurate and reproducible. The proposed MECC method was successfully applied for determination of nucleosides and nucleobases in Chinese Anthopleura lanthogrammica Berkly. The result showed that the species and content of nucleosides and nucleobases in Anthopleura lanthogrammica Berkly samples were abundant.  相似文献   

10.
Two stability indicating methods have been developed for determining rofecoxib in the presence of its degradation product. The first suggested method is high performance liquid chromatography (HPLC), in which analysis is carried out using hypersil BDS C18 column (250 × 4.6 mm I.D.) with mobile Phase consisting of 0.05 M phosphate buffer (pH 3.5) and acetonitrile (70:30 v/v). A linear relationship was obtained between the detector response at 225 nm and the corresponding concentration of the studied rofecoxib in the concentration range (1–6 μg / 10 μl) with mean % recovery of 99.80 ± 0.405. The second method depends on the quantitative densitometric evaluation of thin layer chromatograms (HPTLC) with mobil phase consisting of toluene: chloroform: methanol (60: 35: 5 v/v/v) by using fluorescent high performance silica gel 60 plate. A linear relationship was obtained between peak area and the concentration of the cited drug in the range 1–6 μg/spot with a mean % recovery of 99.79 ± 0.185. The suggested methods are precise, accurate, rapid and prove their specificity in the presence of its degradation products. Both procedures are successfully applied to determine the drug in the presence of its degradation product and also in their pharmaceutical formulations.  相似文献   

11.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

12.
Two simple and accurate methods to determine atorvastatin calcium and ramipril in capsule dosage forms were developed and validated using HPLC and HPTLC. The HPLC separation was achieved on a Phenomenex Luna C18 column (250 x 4.6 mm id, 5 microm) in the isocratic mode using 0.1% phosphoric acid-acetonitrile (38 + 62, v/v), pH 3.5 +/- 0.05, mobile phase at a flow rate of 1 ml/min. The retention times were 6.42 and 2.86 min for atorvastatin calcium and ramipril, respectively. Quantification was achieved with a photodiode array detector set at 210 nm over the concentration range of 0.5-5 microg/mL for each, with mean recoveries (at three concentration levels) of 100.06 +/- 0.49% and 99.95 +/- 0.63% RSD for atorvastatin calcium and ramipril, respectively. The HPTLC separation was achieved on silica gel 60 F254 HPTLC plates using methanol-benzene-glacial acetic acid (19.6 + 80.0 + 0.4, v/v/v) as the mobile phase. The Rf values were 0.40 and 0.20 for atorvastatin calcium and ramipril, respectively. Quantification was achieved with UV densitometry at 210 nm over the concentration range of 50-500 ng/spot for each, with mean recoveries (at three concentration levels) of 99.98 +/- 0.75% and 99.87 +/- 0.83% RSD for atorvastatin calcium and ramipril, respectively. Both methods were validated according to International Conference on Harmonization guidelines and found to be simple, specific, accurate, precise, and robust. The mean assay percentages for atorvastatin calcium and ramipril were 99.90 and 99.55% for HPLC and 99.91 and 99.47% for HPTLC, respectively. The methods were successfully applied for the determination of atorvastatin calcium and ramipril in capsule dosage forms without any interference from common excipients.  相似文献   

13.
In this paper, the simultaneous separation of several polyphenols such as (+)‐catechin, (–)‐epicatechin, (–)‐epigallocatechin, theophylline, caffeine in green and black teas by capillary electrochromatography (CEC) was developed. Several experimental parameters such as stationary phase type, mobile phase composition, buffer and pH, inner diameter of the columns, sample injection, were evaluated to obtain the complete separation of the analysed compounds. Baseline resolution of the studied polyphenols was achieved within 30 min by using a capillary column (id 100 μm) packed with bidentate C18 particles for 24.5 cm and a mobile phase composed of 5 mM ammonium acetate buffer pH 4 with H2O/ACN (80:20, v/v). The applied voltage and the temperature were set at 30 kV and 20°C. Precision, detection and quantification limits, linearity, and accuracy were investigated. A good linearity (R2 > 0.9992) was achieved over a concentration working range of 2–100 μg/mL for all the analytes. LOD and LOQ were 1 and 2 μg/mL, respectively, for all studied compounds. The CEC method was applied to the analysis of those polyphenols in green and black tea samples after an extraction procedure. Good recovery data from accuracy studies ranged between 90% and 112% for all analytes.  相似文献   

14.
《Analytical letters》2012,45(9):1641-1653
Abstract

High performance thin layer chromatographic (HPTLC) and high performance liquid chromatographic (HPLC) methods were developed for the simultaneous determination of Tinidazole and Furazolidone in suspension.

In the HPTLC method the separation of Tinidazole and Furazolidone was carried out on silica gel 60F254 HPTLC glass plate using chloroform:methanol:ammonia (9:1:0.1 v/v) as a mobile phase. Rf values obtained were 0.63 and 0.79 for Furazolidone and Tinidazole respectively. Densitometric evaluation was done at 335 nm. Linearity was obtained within the concentration range 10–50 μg/ml and 3.5–17.5 μg/ml for Tinidazole and Furazolidone respectively.

The second method is based on high performance liquid chromatography on a reversed phase column (μ Bondapak C18) using a mobile phase comprised of water: acetonitrile: triethylamine (80:20:0.1 v/v) adjusted to pH = 3.0 with dil. phosphoric acid. Retention times were 5.24 and 7.82 min for Tinidazole and Furazolidone respectively at a flow rate of 1.5 ml/min. Detection was done at 335 nm. Linearity was obtained within the concentration range 30–180 μg/ml and 10.5–63 μg/ml for Tinidazole and Furazolidone resp.  相似文献   

15.
This study developed and validated a trace-level quantification inorganic impurities method using reversed-phase HPLC and performed the robustness check using quality-by-design approach by varying the multiple factors simultaneously. This method is economical and simple and exhibits its stability-indicating nature [for the determination of ferrocyanide ([Fe(CN)₆]4–), ferricyanide ([Fe(CN)6]3−), nitrate (NO3), and nitrite (NO2)] in sodium nitroprusside (SNP) drug substance and liquid dosage form. Chromatographic separation was achieved using a USP L43 column (ACE PFP, 150 × 4.6 mm, 3 μm) with a simple isocratic elution. The buffer consists of potassium dihydrogen phosphate (50 mM), tetrabutylammonium hydrogen sulfate (9 mM), and tetrabutylammonium hydroxide (25 mM). The buffer pH was adjusted to 7.2 with tetrabutylammonium hydroxide. The mobile phase was mixed with the buffer and acetonitrile (68:32 v/v). The flow rate was 0.8 mL/min, column temperature was maintained at 30°C, and injection volume was 5.0 μL. The SNP impurities were monitored at 225 nm using a UV detector. Further, the method was validated per the International Council for Harmonisation (ICH) guidelines, and forced degradation studies were carried out under different stress conditions. The detector responses were plotted against concentrations, and correlation was linear (r > 0.999) over the range of 0.8–7.5 μg/mL for ferricyanide; 1.0–37.5 μg/mL for SNP; and 0.2–7.5 μg/mL for ferrocyanide, nitrite, and nitrate. The method repeatability was established for all the impurities with relative standard deviation (%), and the results were found to be less than 2.0.  相似文献   

16.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

17.
This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.  相似文献   

18.
This paper describes validated HPLC and HPTLC methods for the simultaneous determination of rosuvastatin (ROS) and ezetimibe (EZE) in a combined tablet dosage form. The isocratic RP-HPLC analysis was performed on a Chromolith C18 column (100 x 6 mm id) using 0.1% (v/v) orthophosphoric acid solution (pH 3.5)-acetonitrile (63 + 37, v/v) mobile phase at a flow rate of 1 mL/min at ambient temperature. Quantification was carried out using a photodiode array UV detector at 245 nm over the concentration range of 0.5-10 microg/mL for ROS and EZE. The HPTLC separation was carried out on an aluminum-backed sheet of silica gel 60F(254) layers using n-butyl acetate-chloroform-glacial acetic acid (1 + 8 + 1, v/v/v) mobile phase. Quantification was achieved with UV densitometry at 245 nm over a concentration range of 0.1-0.9 micro/spot for ROS and EZE. The analytical methods were validated according to International Conference on Harmonization guidelines. Low RSD values indicated good precision. Both methods were successfully applied for the analysis of the drugs in laboratory-prepared mixtures and commercial tablets. No chromatographic interference from the tablet excipients was found. These methods are simple, precise, and sensitive, and are applicable for simultaneous determination of ROS and EZE in pure powder and tablets.  相似文献   

19.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

20.
Column liquid chromatography (LC) and thin-layer chromatography (TLC)-densitometry methods are described for simultaneous determination of acediasulfone (Ace) and cinchocaine (Cinco). In the LC method, the separation and quantitation of the 2 drugs was achieved on a Zorbax C8 column (5 microm, 150 x 4.6 mm id) using a mobile phase composed of methanol-phosphate buffer, pH 2.5 (66 + 34, v/v), at a flow rate of 1 mL/min and ultraviolet detection at 300 and 327 nm for Ace and Cinco, respectively. The method showed linearity over concentration ranges of 20-200 and 45-685 microg/mL, respectively. In the TLC-densitometry method, a mobile phase composed of methanol-tetrahydrofuran-acetic acid (45 + 5 + 0.5, v/v/v) was used for the separation of the 2 drugs. The linearity range was 0.5-4 and 2-9 microg/spot, respectively. In addition, stability indicating TLC-densitometry method has been developed for determination of cefuroxime sodium in the presence of 5-70% of its known hydrolytic degradation products. The mobile phase butanol-methanol-tetrahydrofuran-concentrated ammonium hydroxide (50 + 50 + 50' + 5, v/v/v/v) was used. The concentration range was 2-10 microg/spot. The optimized methods proved to be specific and accurate for the analysis of the cited drugs in laboratory-prepared mixtures and dosage forms. The obtained results agreed statistically with those obtained by the reference methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号