首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and fast method for the simultaneous determination of the antihypertensive drug Valsartan and its metabolite in human plasma has been validated. The proposed method deals with SPE, followed by an HPLC separation coupled with fluorimetric and photometric detection. The optimization of the SPE-HPLC method was achieved by an experimental design. The separation was performed on an RP C18 Atlantis 100 mmx3.9 mm column. The mobile phase consisted of a mixture of ACN 0.025% TFA and phosphate buffer (5 mM, pH = 2.5) 0.025% TFA and was delivered in gradient mode at a flow rate of 1.30 mL/min. The eluent was monitored with a fluorescence detector at 234 and 378 nm excitation and emission wavelengths, respectively, and at 254 nm using a photometric detector. The full analytical validation was performed according to the Food and Drug Administration (FDA) 'guidance for industry: bioanalytical method validation' and the recoveries obtained for Valsartan and its metabolite ranged from 94.6 to 108.8%. The validated method was successfully applied to 12 plasma samples obtained from patients under antihypertensive treatment with Valsartan.  相似文献   

2.
A chemometric approach was applied for the optimization of the extraction and separation of the antihypertensive drug eprosartan from human plasma samples. MultiSimplex program was used to optimize the HPLC-UV method due to the number of experimental and response variables to be studied. The measured responses were the corrected area, the separation of eprosartan chromatographic peak from plasma interferences peaks and the retention time of the analyte.The use of an Atlantis dC18, 100 mm × 3.9 mm i.d. chromatographic column with a 0.026% trifluoroacetic acid (TFA) in the organic phase and 0.031% TFA in the aqueous phase, an initial composition of 80% aqueous phase in the mobile phase, a stepness of acetonitrile of 3% during the gradient elution mode with a flow rate of 1.25 mL/min and a column temperature of 35 ± 0.2 °C allowed the separation of eprosartan and irbesartan used as internal standard from plasma endogenous compounds. In the solid phase extraction procedure, experimental design was used in order to achieve a maximum recovery percentage. Firstly, the significant variables were chosen by way of fractional factorial design; then, a central composite design was run to obtain the more adequate values of the significant variables. Thus, the extraction procedure for spiked human plasma samples was carried out using C8 cartridges, phosphate buffer pH 2 as conditioning agent, a drying step of 10 min, a washing step with methanol-phosphate buffer (20:80, v/v) and methanol as eluent liquid. The SPE-HPLC-UV developed method allowed the separation and quantitation of eprosartan from human plasma samples with an adequate resolution and a total analysis time of 1 h.  相似文献   

3.
The optimisation of a solid phase extraction procedure involves several variables whose influence has been widely studied. However, in most cases, only process variables are taken into account. In this work, the influence of those process variables together with the fact of using mixtures of solvents during the elution step of the solid phase extraction of four angiotensin II receptor antagonist drugs has been studied. Since the influence on the extraction efficiency of several process variables were simultaneously tested, a D-optimal design was constructed. The composition of the elution solvent (a mixture of methanol, acetonitrile, ethanol and acetone at different proportions from 0 to 100% each solvent), the percentage and pH of the buffer solution added to the urine samples at the beginning of the extraction procedure; the percentage of the organic component and the volume of the washing solution, the drying time and the volume of the elution solvent were the studied variables. The chromatographic separation was carried out by gradient elution mode with 0.026% trifluoroacetic acid (TFA) in the organic phase and 0.031% TFA in the aqueous phase using an Atlantis dC18, 100 mm × 3.9 mm I.D. chromatographic column at a flow rate of 1 mL/min and a column temperature of 35 ± 0.2 °C. For detection a diode array detector set at 232 nm was used. The extraction procedure for spiked human urine samples was developed using C8 cartridges, phosphate buffer pH 6.8 as conditioning agent, a drying step of 10 min, a washing step with methanol-phosphate buffer (20:80, v/v) and methanol as eluent. Recovery percentages obtained: 84% for eprosartan, 74% for telmisartan, 74% for irbesartan and 89% for valsartan allow the determination of these drugs concentration levels in urine.  相似文献   

4.
Asymmetric N(G),-N(G)-dimethylarginine (ADMA) increases in diseases such as renal failure, diabetes mellitus, and hypercholesterolemia. The feasibility and utility of a hydrophilic interaction chromatography (HILIC) method for the separation of free L-arginine (Arg), ADMA, and symmetric N(G),-N(G')-dimethylarginine (SDMA) on a typical silica column were explored and the impact of some experimental parameters on the chromatographic behavior of these analytes was investigated. The effect of water and TFA content in mobile phase and of column temperature was investigated during the development of a fast and simple HILIC-MS/MS method that might be suitable for the quantification of free Arg, ADMA, and SDMA in plasma for routine analysis. Our results show that a good compromise between efficiency and peak shape with acceptable retention and total chromatographic run time is achieved using an ACN/water (90:10) mobile phase with TFA% as additive ranging from 0.015 to 0.025% and column temperature ranging from 25 to 30 degrees C.  相似文献   

5.
The objective of the present work was to investigate the chromatographic behavior of natural phenolic compounds in micellar and aqueous‐organic LC using a short column packed with 1.8 μm particles. Firstly, the effect of ACN and SDS on elution strength and selectivity was examined by isocratic submicellar (0–30% ACN/5% 1‐butanol/1–6 mM SDS) and micellar (0–30% ACN/5% 1‐butanol/40–60 mM SDS) systems. The varied concentrations of two modifiers in the mobile phases revealed different eluting power. Then, the application of organic modifier gradient was discussed in both submicellar and micellar LC using mobile phases of 4 mM SDS/5% 1‐butanol or 50 mM SDS/5% 1‐butanol containing ACN gradient from 0 to 30%, respectively. For micellar system, the separation was found to be better in gradient than isocratic elution. Additionally, the sensitivity of aqueous‐organic LC was examined. The mobile phase was a mixture of ACN and water employing gradient elution at a flow rate of 0.5 mL/min, with analysis time below 9 min. It was found that separation efficiency was significantly better compared with micellar LC. Besides, the aqueous‐organic LC has been applied to separation of various phenolic compounds in Yangwei granule or Radix Astragali samples.  相似文献   

6.
A direct plasma injection liquid chromatographic method has been developed for the determination of a new triazole antifungal agent, voriconazole, using an internal surface reversed phase column. Therapeutic drug monitoring of voriconazole is relevant for patient management, especially in the case of drug-drug interaction. The method is easy to perform and requires 10 microL of a plasma sample. The chromatographic run time is less than 9 min using a mobile phase of 17:83 v/v acetonitrile-potassium dihydrogen phosphate buffer, 100 mM, pH 6.0 and UV detection at 255 nm. The fl ow rate was 1 microL/min. A linear response was observed over the concentration range 0.5-10 microg/mL (r2 = 0.977). A good accuracy (bias < or = 7.5%) was achieved for all quality controls, with intra-day and inter-day variation coefficients inferior to 6.7%. The lower limit of quantitation was 0.2 microg/mL, without interference of endogenous components. The stability of voriconazole in plasma stored at different temperatures was checked. Finally, the possibility of direct injection of plasma samples into the column permits a reduction in reagent consumption and in analytical steps, and hence in analytical error.  相似文献   

7.
A simple, rapid and reliable reversed‐phase ion‐pair chromatography method by HPLC coupled to an evaporative light scattering detector (ELSD) has been developed to simultaneously determine chloride, spectinomycin and its related substances in a sample. The column was a TSKgel ODS‐100V. The mobile phase was ACN/aqueous solution of 15 mM ammonium acetate adjusted with TFA to pH 3.0 (2:98 v/v), in an isocratic mode. The drift tube temperature was set at 50°C and the nebulizing gas flow rate of air was 3.5 L/min for ELSD detection. Almost all of the reported degradation compounds of spectinomycin such as actinamine, actinospectinoic acid and biosynthesis intermediates such as dihydrospectinomycin diastereoisomers were baseline separated. MS was utilized for the identification of spectinomycin and its seven related substances. The method for the assay of spectinomycin was successfully validated with respect to accuracy, precision (RSD less than 2%), linearity (throughout the linear range 0.025–3 mg/mL, r=0.9993), sensitivity (LOD: 100 ng on column) and robustness. The experimental results demonstrated that the simultaneous determination of chloride, spectinomycin and related substances is feasible in a single run, which suggests applicability in routine assays.  相似文献   

8.
Published high-performance liquid chromatographic (HPLC) methods for the determination of tetracyclines are modified to determine low levels of each of 15 tetracycline derivatives in small blood samples. The rapid and accurate methods are applicable to pharmacokinetic studies in small experimental animals. The chromatographic procedures allow run times ranging from 2.1-7.3 min using different reversed-phase materials as supports and eluents based on acetonitrile or isopropanol-diethanolamine-EDTA. Detection limits are estimated at 10-500 ng/mL according to the derivative analyzed. The extraction from plasma is based on acidic precipitation of the plasma proteins using trifluoroacetic acid (TFA). The recovery of 13 derivatives from spiked plasma samples (100 micrograms/mL) reached 85-94% (n = 5). The precision data, expressed as coefficient of variation, ranged between 2.1 to 9.1% within run (n = 10) and 4.3 to 11.0% between day (n = 8) respectively.  相似文献   

9.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of insulin in nanoparticulate dosage forms. Its application for the development and characterization of insulin-loaded nanoparticulates composed of polyelectrolytes has also been carried out. A reversed-phase (RP) C18 column and gradient elution with a mobile phase composed of acetonitrile (ACN) and 0.1% aqueous trifluoroacetic acid (TFA) solution at a flow rate of 1 mL/min was used. Protein identification was made by UV detection at 214 nm. The gradient changed from 30:70 (ACN:TFA, v/v) to 40:60 (v/v) in 5 min followed by isocratic elution at 40:60 (v/v) for a further five minutes. The method was linear in the range of 1-100 microg/mL (R2 = 0.9996), specific with a good inter-day and intra-day precision based on relative standard deviation values (less than 3.80%). The recovery was between 98.86 and 100.88% and the detection and quantitation limits were 0.24 and 0.72 microg/mL, respectively. The method was further tested for the determination of the association efficiency of insulin to nanoparticulate carriers composed of alginate and chitosan, as well as its loading capacity for this protein. Encapsulant release under simulated gastrointestinal fluids was evaluated. The method can be used for development and characterization of insulin-loaded nanoparticles made from cross-linked chitosan-alginate.  相似文献   

11.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

12.
A micellar electrokinetic chromatographic (MEKC) method and a fast reversed-phase liquid chromatographic one have been developed for determining the purity of ampicillin. MEKC separation of ampicillin and its related substances was performed with the use of an untreated fused-silica capillary and 40 mM phosphate-borate buffer, pH 7.5 containing 75 mM SDS. The HPLC method employed a monolithic silica C18 column and a mobile phase composed of phosphate buffer, pH 5.2 and ACN, the flow rate being 4.0 mL/min. Both methods were successfully validated. Linearity, relative response factors, limits of quantitation, intermediate precision, and accuracy were evaluated. The methods proved to be fast, reliable, and sufficiently sensitive and, accordingly, well-suited for control of purity of ampicillin substance, injections, and capsules. A combination of both methods can be very useful in the confirmation of impurity profiles.  相似文献   

13.
Cheng HL  Jong YJ  Li JH  Ko WK  Wu SM 《Electrophoresis》2006,27(23):4711-4716
Direct analysis of methamphetamine, amphetamine, and p-hydroxymethamphetamine in urine was achieved by cation-selective exhaustive injection and sweeping micellar EKC. A bare fused-silica capillary (40 cm, 50 microm id) was filled with phosphate buffer (80 mM, pH 3, containing 20% ACN). Then a high-conductivity buffer (100 mM phosphate, pH 3; 6.9 kPa for 2.5 min) was injected. Samples were loaded using electrokinetic injection (10 kV, 600 s) which created long zones of cationic analytes. To enhance sensitivity by sweeping, the stacking step was performed using a phosphate buffer (50 mM, pH 3, containing 20% ACN and 100 mM SDS) at -20 kV before separation by MEKC. This method was capable of detecting the analytes at ppb levels. The calibration plots were linear (r(2) >or= 0.9948) over a range of 100-5000 ng/mL for methamphetamine, and 100-2000 ng/mL for amphetamine and p-hydroxymethamphetamine. The LODs (S/N = 3) were 20 ng/mL for methamphetamine, and 15 ng/mL for amphetamine and p-hydroxymethamphetamine. The method was applied to analysis of 14 urine samples of addicts and is suitable for screening suspected samples for forensic purposes. The results showed good agreement with fluorescence polarization immunoassay and GC-MS.  相似文献   

14.
A sensitive method for the simultaneous determination of loratadine and its major active metabolite descarboethoxyloratadine (DCL) in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from plasma with toluene followed by back-extraction into formic acid (2%) for DCL after which the toluene containing the loratadine was evaporated, the analyte reconstituted and combined with the DCL back-extract. Chromatography was performed on a Phenomenex Luna C18 (2) 5-microm, 150x2.1-mm column with a mobile phase consisting of acetonitrile-0.1% formic acid using gradient elution (10 to 90% acetonitrile in 2 min) at a flow-rate of 0.3 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery for loratadine and descarboethoxyloratadine was 61 and 100%, respectively, with a lower limit of quantification at 0.10 ng/ml for both the analyte and its metabolite. This is the first assay method described for the simultaneous determination of loratadine and descarboethoxyloratadine in plasma using one chromatographic run. The method is sensitive and reproducible enough to be used in pharmacokinetic studies.  相似文献   

15.
A reliable micellar electrokinetic chromatographic method for the determination of oxcarbazepine and its two main metabolites, 10-hydroxycarbamazepine and 10,11-trans-dihydroxy-10,11-dihydroxycarbamazepine, in human plasma was developed. The separation and determination of the analytes was achieved using a system consisting of 60 mM SDS in phosphate buffer (30 mM, pH 8.0), to which 20% (v/v) methanol was added. Separation was carried out in an uncoated fused-silica capillary with a separation voltage of 25 kV and currents typically less than 40 microA. Spectrophotometric detection was at 205 nm. Isolation of oxcarbazepine and its metabolites from plasma was accomplished by a solid-phase extraction procedure. The mean extraction yield of the analytes from plasma was higher than 94%. The linear correlation coefficients were better than 0.994 for all analytes. The limit of detection was 0.05 microg/mL, the limit of quantitation 0.15 microg/mL. The repeatability for the spiked blank plasma samples was lower than 1.9% and the intermediate precision lower than 2.1%, both expressed as RSD%. The results obtained analysing real plasma samples from epileptic patients under therapy with Tolep were satisfactory in terms of precision, accuracy and detectability.  相似文献   

16.
A rapid and selective HPLC‐UV method was developed for the quantification of linezolid (LNZ) in human plasma and bronchoalveolar lavage (BAL) at the concentrations associated with therapy. Plasma samples were extracted by solid‐phase extraction followed by evaporation to dryness and reconstitution in mobile phase solution. The chromatographic separation was carried out on a C18 column with an isocratic mobile phase consisting of dihydrogen phosphate buffer 50 mm (pH 3.5) and acetonitrile (60:40 v/v). The detection was performed using a photodiode array. Under these conditions, a single chromatographic run could be completed within 12 min. The method was validated by estimating the precision and the accuracy for inter‐ and intra‐day analysis in the concentration range of 25–25600 ng/mL. The method was linear over the investigated range with all the correlation coefficients R > 0.999. The intra‐ and inter‐day precision was within 8.90% and the accuracy ranged from ?4.76 to +5.20%. This rapid and sensitive method was fully validated and could be applied to pharmacokinetic study for the determination of LNZ levels in human plasma and BAL samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A new and accurate HPLC method using sulfobutylether-beta-cyclodextrin (SBE-beta-CD) as chiral mobile phase additive (CMPA) was developed and validated for the determination of R-(+)pantoprazole in S-(-)pantoprazole. The influences of type and concentration of CD, ACN content and buffer pH of mobile phase on the resolution and retention of enantiomers were investigated. A baseline resolution of pantoprazole enantiomers was achieved on a Spherigel C18 column (150 mm x 4.6 mm, 5 microm) using ACN and 10 mM phosphate buffer (pH 2.5) containing 10 mM SBE-beta-CD (15:85 v/v) as mobile phase with a flow rate of 0.9 mL/min at 20 degrees C. The detection wavelength was set at 290 nm. The method was extensively validated in terms of accuracy, precision and linearity according to the International Conference on Harmonisation (ICH) guidelines and proved to be robust. The LOD and LOQ for R-(+)pantoprazole were 0.2 and 0.5 microg/mL, respectively, with 5 microL injection volume. A good linear relationship was obtained in the concentration range of 0.5-6.0 microg/mL with r(2) >0.999 for R-(+)pantoprazole. The percentage recovery of the R-(+)pantoprazole ranged from 92.1 to 101.2 in bulk drug of S-(-)pantoprazole. The method is capable of determining a minimum limit of 0.05% w/w of R-enantiomer in S-(-)pantoprazole bulk samples.  相似文献   

18.
The ability of different stationary phases developed for the analysis of polar compounds (ZIC-HILIC, ZIC-pHILIC and Zorbax SB-Aq) to separate isoniazid, its metabolites (acetylisonazid, pyridoxal isonicotinoyl hydrazone, pyridoxal isonicotinoyl hydrazone 5-phosphate), pyridoxine, pyridoxal and pyridoxal 5-phosphate under MS compatible conditions was systematically investigated using HPLC-UV. The mobile phase strength, pH and buffer concentration were modified to assess their impact on the retention of these compounds. The best available separation of the compounds was achieved using 1 mM ammonium formate (pH≈6) and ACN (20:80, v/v) on ZIC-HILIC and employing 5 mM ammonium formate (pH 3.0) and ACN (40:60, v/v) on ZIC-pHILIC. A gradient profile using 0.5 mM ammonium formate (pH≈6) and MeOH (0-12 min: 10% MeOH, 12-15 min: 10-50% MeOH, 15-35 min: 50% MeOH, 35.0-35.2 min: 50-10% MeOH, 35.2-45.0 min: 10% MeOH) provided the best separation of the compounds on Zorbax SB-Aq. Subsequent LC-MS analysis demonstrated that ZIC-HILIC is useful for the analysis of pyridoxine, pyridoxal and pyridoxal isonicotinoyl hydrazone. However, the chromatographic conditions developed for the analysis of the compounds on Zorbax SB-Aq are capable of achieving the best separation of all compounds in this study with the higher sensitivity for most of the analytes.  相似文献   

19.
A highly sensitive high-performance liquid chromatographic method with fluorescence detection has been developed and validated in a single laboratory for the trace determination of trimetazidine (TMZ) in human plasma. Fluoxetine (FLX) was used as the internal standard. TMZ and FLX were isolated from plasma by protein precipitation with acetonitrile and derivatized by heating with 7-chloro-4-nitrobenzo-2-oxa-1,3-diazole in pH 8 borate buffer at 70 degrees C for 30 min. Separations were performed in the isocratic mode on a Nucleosil CN column with the mobile phase acetonitrile-10 mM sodium acetate buffer (pH 3.5)-methanol (47 + 47 + 6, v/v/v) at a flow rate of 1.0 mL/min. The derivatized samples were excited at 470 nm and monitored at an emission wavelength of 530 nm. Under the optimum chromatographic conditions, a linear relationship with a good correlation coefficient (r = 0.9997, n = 5) was obtained for the peak area ratio of TMZ to FLX and for TMZ concentrations of 1-120 ng/mL. The proposed method has the lowest limits of detection and quantitation reported to date for the determination of TMZ in plasma with values of 0.3 and 0.95 ng/mL, respectively. The values for intra- and interassay precision were satisfactory; the relative standard deviations were < or =4.04%. The accuracy of the method was demonstrated; the recoveries of TMZ from spiked human plasma were 98.13-102.83 +/- 0.2-4.04%. The method has high throughput because of its simple sample preparation procedure and short run time (<10 min). The results demonstrated that the proposed method would have great value when applied in pharmacokinetic studies for TMZ.  相似文献   

20.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号