首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Do J  Ahn CH 《Lab on a chip》2008,8(4):542-549
This paper presents a new polymer lab-on-a-chip for magnetic bead-based immunoassay with fully on-chip sampling and detection capabilities, which provides a smart platform of magnetic immunoassay-based lab-on-a-chip for point-of-care testing (POCT) toward biochemical hazardous agent detection, food inspection or clinical diagnostics. In this new approach, the polymer lab-on-a-chip for magnetic bead-based immunoassay consists of a magnetic bead-based separator, an interdigitated array (IDA) micro electrode, and a microfluidic system, which are fully incorporated into a lab-on-a-chip on cyclic olefin copolymer (COC). Since the polymer lab-on-a-chip was realized using low cost, high throughput polymer microfabrication techniques such as micro injection molding and hot embossing method, a disposable polymer lab-on-a-chip for the magnetic bead-based immunoassay can be successfully realized in a disposable platform. With this newly developed polymer lab-on-a-chip, an enzyme-labelled electrochemical immunoassay (ECIA) was performed using magnetic beads as the mobile solid support, and the final enzyme product produced from the ECIA was measured using chronoamperometry. A sampling and detection of as low as 16.4 ng mL(-1) of mouse IgG has been successfully performed in 35 min for the entire procedure.  相似文献   

2.
The combination of electrophoretic and magnetic manipulations with electrochemical detection for a versatile microfluidic and bead-based biosensing application is demonstrated. Amperometric detection is performed in an off-channel setup by means of a voltammetric cell built at the microchannel outlet and using a gold working electrode. Superparamagnetic particles are introduced and handled inside the channel by means of an external permanent magnet in combination with the electrogenerated flow which allows reproducible loading. The specific detection of phenol as electroactive alkaline phosphatase product is used in this study as proof of concept for a sensitive protein quantification. Characterizations and optimization of different parameters have been carried out in order to achieve the best detection signal. The applicability of the device has been finally demonstrated by the detection of rabbit IgG as model protein after an immunoassay performed on magnetic particles as immobilization platform. A comparison between the electrochemical detection using the developed device and the optical standard detection revealed similar performances with, however, extremely lower amount of reagent used and shorter analysis time. The developed electrophoretic- and magnetic-based chip may open the way to several other biosensing applications with interest not only for other proteins but also for DNA analysis, cell counting, and environmental control.  相似文献   

3.
A facile and sensitive aptamer‐based protocol has been developed for protein assay on microfluidic platform with fluorescence detection using an off‐chip microarray scanner. Aptamer‐functionalized magnetic beads were used to capture thrombin that binds to a second aptamer fluorescently labeled by Cy3. Experimental conditions, such as incubation time and temperature, washing time, interfering proteins, and aptamer, etc., were optimized for the microchip method. This work demonstrated there was a good relationship between fluorescence intensity and thrombin concentration in the range of 65–1000 ng/mL with the RSD less than 8%. Notably, an analysis only needs 1 μL volume of sample injection and this system can capture extremely tiny amount thrombin (0.4 fmol). This method has been successfully applied to assay of thrombin in human serum with the recovery of 79.74–95.94%.  相似文献   

4.
Wang CH  Lien KY  Wu JJ  Lee GB 《Lab on a chip》2011,11(8):1521-1531
This study reports a new diagnostic assay for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) by combing nucleic acid extraction and isothermal amplification of target nucleic acids in a magnetic bead-based microfluidic system. By using specific probe-conjugated magnetic beads, the target deoxyribonucleic acid (DNA) of the MRSA can be specifically recognized and hybridized onto the surface of the magnetic beads which are then mixed with clinical sample lysates. This is followed by purifying and concentrating the target DNA from the clinical sample lysates by applying a magnetic field. Nucleic acid amplification of the target genes can then be performed by the use of a loop-mediated isothermal amplification (LAMP) process via the incorporation of a built-in micro temperature control module, followed by analyzing the optical density (OD) of the LAMP amplicons using a spectrophotometer. Significantly, experimental results show that the limit of detection (LOD) for MRSA in the clinical samples is approximately 10 fg μL(-1) by performing this diagnostic assay in the magnetic bead-based microfluidic system. In addition, the entire diagnostic protocol, from bio-sample pre-treatment to optical detection, can be automatically completed within 60 min. Consequently, this miniature diagnostic assay may become a powerful tool for the rapid purification and detection of MRSA and a potential point-of-care platform for detection of other types of infections.  相似文献   

5.
Wang YC  Han J 《Lab on a chip》2008,8(3):392-394
Almost all immuno-biosensors are inherently limited by the quality of antibodies available for the target molecule, and obtaining a highly sensitive antibody for a given target molecule is a challenge. We describe a highly efficient and flexible way to enhance immunoassay detection sensitivity and binding kinetics using a nanofluidic based electrokinetic preconcentrator. The device is a microfluidic integration of charge-based biomolecule concentrator and a bead-based immunoassay. Because the preconcentrator can increase the local biomolecule concentration by many orders of magnitude, it gives the immuno-sensor better sensitivity and faster binding kinetics. With a 30 min preconcentration, we were able to enhance the immunoassay sensitivity (with molecular background) by more than 500 fold from higher 50 pM to the sub 100 fM range. Moreover, by adjusting the preconcentration time, we can switch the detection range of the given bead-based assay (from 10-10 000 ng ml(-1) to 0.01-10 000 ng ml(-1)) to have a broader dynamic range of detection. As the system can enhance both detection sensitivity and dynamic range, it can be used to address the most critical detection issues in the detection of common disease biomarkers.  相似文献   

6.
Lien KY  Chuang YH  Hung LY  Hsu KF  Lai WW  Ho CL  Chou CY  Lee GB 《Lab on a chip》2010,10(21):2875-2886
The present study reports a new three-dimensional (3D) microfluidic platform capable of rapid isolation and detection of cancer cells from a large sample volume (e.g. ~1 mL) by utilizing magnetic microbead-based technologies. Several modules, including a 3D microfluidic incubator for the magnetic beads to capture cancer cells, a microfluidic control module for sample transportation and a nucleic acid amplification module for genetic identification, are integrated into this microsystem. With the incorporation of surface-modified magnetic beads, target cancer cells can be specifically recognized and conjugated onto the surface of the antibody-coated magnetic microbeads by utilizing a swirling effect generated by the new 3D microfluidic incubator, followed by isolating and purifying the magnetic complexes via the incorporation of an external magnet and a microfluidic control module, which washes away any unbound waste solution. Experimental results show that over 90% of the target cancer cells can be isolated from a large volume of bio-samples within 10 min in the 3D microfluidic incubator. In addition, the expressed genes associated with ovarian and lung cancer cells can also be successfully amplified by using the on-chip nucleic acid amplification module. More importantly, the detection limit of the developed system is found to be 5 × 10(1) cells mL(-1) for the target cancer cells, indicating that this proposed microfluidic system may be adapted for clinical use for the early detection of cancer cells. Consequently, the proposed 3D microfluidic system incorporated with immunomagnetic beads may provide a promising automated platform for the rapid isolation and detection of cancer cells with a high sensitivity.  相似文献   

7.
This study reports the development of a microfluidic bead-based nucleic acid sensor for sensitive detection of circulating tumor cells in blood samples using multienzyme-nanoparticle amplification and quantum dot labels. In this method, the microbeads functionalized with the capture probes and modified electron rich proteins were arrayed within a microfluidic channel as sensing elements, and the gold nanoparticles (AuNPs) functionalized with the horseradish peroxidases (HRP) and DNA probes were used as labels. Hence, two signal amplification approaches are integrated for enhancing the detection sensitivity of circulating tumor cells. First, the large surface area of Au nanoparticle carrier allows several binding events of HRP on each nanosphere. Second, enhanced mass transport capability inherent from microfluidics leads to higher capture efficiency of targets because continuous flow within micro-channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based nucleic acid sensor could discriminate as low as 5 fM (signal-to-noise (S/N) 3) of synthesized carcinoembryonic antigen (CEA) gene fragments and showed a 1000-fold increase in detection limit compared to the off-chip test. In addition, using spiked colorectal cancer cell lines (HT29) in the blood as a model system, the detection limit of this chip-based approach was found to be as low as 1 HT29 in 1 mL blood sample. This microfluidic bead-based nucleic acid sensor is a promising platform for disease-related nucleic acid molecules at the lowest level at their earliest incidence.  相似文献   

8.
Novo P  Prazeres DM  Chu V  Conde JP 《Lab on a chip》2011,11(23):4063-4071
Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.  相似文献   

9.
基于电化学发光及磁悬浮免疫分析策略,结合磁性石墨烯独特的物理化学特性以及纸基电极价格低廉、样品用量少的优势,建立了一种新型免疫分析方法.以人免疫球蛋白G(IgG)为分析物,采用1-乙基-3-(3-二甲基氨丙基)-碳化二亚胺/N-羟基硫代琥珀酰亚胺(EDC/NHS)法将一抗(Ab1,捕获抗体)固定在磁性石墨烯上,通过直接标记法进行二抗(Ab2,信号抗体)的电化学发光试剂标记,采用磁悬浮夹心免疫技术最大程度减少非特异性吸附,通过纸基电化学发光检测技术测定目标物的浓度.考察了捕获抗体及信号抗体的固定(标记)效果,发现采用的磁性石墨烯不仅提高了免疫物质的负载量,还可以促进电子传递,构建的磁悬浮纸基电化学发光夹心免疫分析法的电化学发光响应峰面积在0.32~1000 ng/mL浓度范围内,与IgG浓度对数值呈良好的线性关系,检出限为6.4 pg/mL.本方法可实现IgG的定量检测,在低成本、快速免疫检测领域有一定的应用前景.  相似文献   

10.
Hervás M  López MA  Escarpa A 《The Analyst》2011,136(10):2131-2138
Microfluidic technology has now become a novel sensing platform where different analytical steps, biological recognition materials and suitable transducers can be cleverly integrated yielding a new sensor generation. A novel "lab-on-a-chip" strategy integrating an electrokinetic magnetic bead-based electrochemical immunoassay on a microfluidic chip for reliable control of permitted levels of zearalenone in infant foods is proposed. The strategy implies the creative use of the simple channel layout of the double-T microchip to perform sequentially the immunointeraction and enzymatic reaction by applying a program of electric fields suitably connected to the reservoirs for driving the fluidics at different chambers in order to perform the different reactions. Both zones are used with the aid of a magnetic field to avoid in a very simple and elegant way the non-specific adsorption. Immunological reaction is performed under a competitive enzyme-linked immunosorbent assay (ELISA) where the mycotoxin ZEA and an enzyme-labelled derivative compete for the binding sites of the specific monoclonal antibody immobilised onto protein G modified magnetic beads. Horseradish peroxidase (HRP), in the presence of hydrogen peroxide, catalyses the oxidation of hydroquinone (HQ) to benzoquinone (BQN), whose back electrochemical reduction was detected at +0.1 V. Controlled-electrokinetic fluidic handling optimized conditions are addressed for all analytical steps cited above, and allows performing the complete immunoassay for the target ZEA analyte in less than 15 minutes with unique analytical merits: competitive immunoassay currents showed a very well-defined concentration dependence with a good precision as well as a suitable limit of detection of 0.4 μg L(-1), well below the legislative requirements, and an extremely low systematic error of 2% from the analysis of a maize certified reference material revealing additionally an excellent accuracy. Also, the reliability of the approach is demonstrated by the analysis of selected infant foods yielding the strictest ZEA permitted levels and excellent recoveries of 103 and 101% for solid and liquid samples, respectively.  相似文献   

11.
Puleo CM  Yeh HC  Liu KJ  Wang TH 《Lab on a chip》2008,8(5):822-825
The recent proliferation of platforms designed to handle arrays of nano- and picolitre volumes is in response to the need to perform biological assays on discrete entities, such as single cells. However, a critical challenge associated with this trend for in vitro compartmentalization is the need for highly sensitive, yet low-volume detection platforms. In this paper, we coupled confocal fluorescence detection with recirculating microfluidic control to perform single particle DNA assays within five nL chambers. The performance of this low-volume assay was shown to match that of traditional single molecule detection platforms. However, volume requirements per measurement were nearly 3 orders of magnitude less than conventional systems, enabling future integration with lab-on-a-chip systems that require discrete or digitalized sample processing.  相似文献   

12.
A surface plasmon resonance (SPR) sensor on a compact disk (CD)-type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD-type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled-type SPR. The sample and reagent solutions in the reservoirs on the CD-type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD-type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti-IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti-IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.  相似文献   

13.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

14.
Kim KS  Park JK 《Lab on a chip》2005,5(6):657-664
This paper describes a novel microfluidic immunoassay utilizing binding of superparamagnetic nanoparticles to beads and deflection of these beads in a magnetic field as the signal for measuring the presence of analyte. The superparamagnetic 50 nm nanoparticles and fluorescent 1 microm polystyrene beads are immobilized with specific antibodies. When target analytes react with the polystyrene beads and superparamagnetic nanoparticles simultaneously, the superparamagnetic nanoparticles can be attached onto the microbeads by the antigen-antibody complex. In the poly(dimethylsiloxane)(PDMS) microfluidic channel, only the microbeads conjugated with superparamagnetic nanoparticles by analytes consequently move to the high gradient magnetic fields under the specific applied magnetic field. In this study, the magnetic force-based microfluidic immunoassay is successfully applied to detect the rabbit IgG and mouse IgG as model analytes. The lowest concentration of rabbit IgG and mouse IgG measured over the background is 244 pg mL(-1) and 15.6 ng mL(-1), respectively. The velocities of microbeads conjugated with superparamagnetic nanoparticles are demonstrated by magnetic field gradients in microfluidic channels and compared with the calculated magnetic field gradients. Moreover, dual analyte detection in a single reaction is also performed by the fluorescent encoded microbeads in the microfluidic device. Detection range and lower detection limit can be controlled by the microbeads concentration and the higher magnetic field gradient.  相似文献   

15.
Two major issues need to be addressed in applying semiconductor biosensors to detecting proteins in immunoassays. First, the length of the antibody on the sensor surface surpasses the Debye lengths (approximately 1 nm, in normal ionic strength solution), preventing certain specifically bound proteins from being tightly attached to the sensor surface. Therefore, these proteins do not contribute to the sensor’s surface potential change. Second, these proteins carry a small charge and can be easily affected by the pH of the surrounding solution. This study proposes a magnetic bead-based immunoassay using a secondary antibody to label negatively charged DNA fragments for signal amplification. An externally imposed magnetic force attaches the analyte tightly to the sensor surface, thereby effectively solving the problem of the analyte protein’s distance to the sensor surface surpassing the Debye lengths. In addition, a normal ion intensity buffer can be used without dilution for the proposed method. Experiments revealed that the sensitivity can be improved by using a longer DNA fragment for labeling and smaller magnetic beads as solid support for the antibody. By using a 90 base pair DNA label, the signal was 15 times greater than that without labeling. In addition, by using a 120 nm magnetic bead, a minimum detection limit of 12.5 ng mL−1 apolipoprotein A1 can be measured. Furthermore, this study integrates a semiconductor sensor with a microfluidic chip. With the help of microvalves and micromixers in the chip, the length of the mixing step for each immunoassay has been reduced from 1 h to 20 min, and the sample volume has been reduced from 80 μL to 10 μL. In practice, a protein biomarker in a urinary bladder cancer patient’s urine was successfully measured using this technique. This study provides a convenient and effective method to measure protein using a semiconductor sensor.  相似文献   

16.
Huh YS  Park TJ  Lee EZ  Hong WH  Lee SY 《Electrophoresis》2008,29(14):2960-2969
An active micromixer system utilizing the magnetic force was developed and examined for its ability to facilitate the mixing of more than two fluid flows. The mixing performance of the active micromixer was evaluated in aqueous-aqueous systems including dyes for visual observation. A complete analytical microfluidic system was developed by integrating various functional modules into a single chip, thus allowing cell lysis, sample preparation, purification of intracellular molecules, and subsequent analysis. Upon loading the cell samples and lysis solution into the mixing chamber, the integrated microfluidic device allows efficient cell disruption by rotation of a micromagnetic disk and control of mixing time using the Teflon-coated hydrophobic film as a microvalve. This inflow is followed by separating the cell debris and contaminated proteins from the cell lysate sample using the acrylamide (AAm)-functionalized SPE. The inflow of partially purified cell lysate sample containing the gold binding polypeptide (GBP)-fusion protein was bound onto the gold micropatterns by means of its metal binding affinity. The GBP-fusion method allows immobilization of proteins in bioactive forms onto the gold surface without surface modification suitable for studying antigen-antibody interaction. It was used for the detection of severe acute respiratory syndrome (SARS), an infectious viral disease, as an example case.  相似文献   

17.
Kim DS  Lee SH  Ahn CH  Lee JY  Kwon TH 《Lab on a chip》2006,6(6):794-802
Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 microl of the whole sample bloods, by means of the fabricated biochip within 3 min.  相似文献   

18.
Measuring reaction kinetics in a lab-on-a-chip by microcoil NMR   总被引:5,自引:0,他引:5  
A microfluidic chip with an integrated planar microcoil was developed for Nuclear Magnetic Resonance (NMR) spectroscopy on samples with volumes of less than a microliter. Real-time monitoring of imine formation from benzaldehyde and aniline in the microreactor chip by NMR was demonstrated. The reaction times in the chip can be set from 30 min down to ca. 2 s, the latter being the mixing time in the microfluidic chip. Design rules will be described to optimize the microreactor and detection coil in order to deal with the inherent sensitivity of NMR and to minimize magnetic field inhomogeneities and obtain sufficient spectral resolution.  相似文献   

19.
The suitability of a microelectrode as the detector for a small-volume, bead-based enzyme-labeled immunoassay for later use in a microfluidic device was investigated. The microelectrode helps to overcome consumption of the electroactive species by the electrode (depletion) that is encountered with macroelectrodes such as the rotating disk electrode (RDE) and allows the volume of the detection cell to be reduced. Microelectrodes also allow the chemical reactions to be monitored in real time due to the electrodes close proximity to the assay site. A bead-based sandwich immunoassay for mouse IgG was developed with alkaline phosphatase (AP) as the enzyme label, p-aminophenyl phosphate (PAPP) as the enzyme substrate, and microelectrode detection. The diffusion coefficient of the product of enzymatic hydrolysis, p-aminophenol (PAP), was determined to be 7.2±0.9×10–6 cm2 s–1. The detection limits were determined for free (0.52 ng mL–1) and bead-bound AP (10 ng mL–1). The number of binding sites for AP per bead was calculated to be 9.6×104 molecules/bead, and under saturation conditions the minimum detectable number of beads was 2500. Lower detection limits could be achieved with the microelectrode than the RDE while maintaining similar reproducibility. The microelectrode also made it possible to work with lower sample volumes (down to 10 L) than with the RDE (minimum volume of 40 L). Depletion of PAP was not observed with the microelectrode. The results obtained here with a microelectrode showed great promise for later use of microelectrodes in microfluidic devices with limited sample volumes. RDE detection cannot be used in a microfluidic system due to its complex set-up that includes a motor for rotation.Abbreviations: Ab Antibody - Ag Antigen - AP Alkaline phosphatase - NSA Nonspecific adsorption - PAP p-aminophenol - PAPP p-aminophenyl phosphate - RDE Rotating disk electrode - NSA Nonspecific adsorption - PBS Phosphate-buffered saline  相似文献   

20.
L Ge  S Wang  X Song  S Ge  J Yu 《Lab on a chip》2012,12(17):3150-3158
A novel 3D microfluidic paper-based immunodevice, integrated with blood plasma separation from whole blood samples, automation of rinse steps, and multiplexed CL detections, was developed for the first time based on the principle of origami (denoted as origami-based device). This 3D origami-based device, comprised of one test pad surrounded by four folding tabs, could be patterned and fabricated by wax-printing on paper in bulk. In this work, a sandwich-type chemiluminescence (CL) immunoassay was introduced into this 3D origami-based immunodevice, which could separate the operational procedures into several steps including (i) folding pads above/below and (ii) addition of reagent/buffer under a specific sequence. The CL behavior, blood plasma separation, washing protocol, and incubation time were investigated in this work. The developed 3D origami-based CL immunodevice, combined with a typical luminuol-H(2)O(2) CL system and catalyzed by Ag nanoparticles, showed excellent analytical performance for the simultaneous detection of four tumor markers. The whole blood samples were assayed and the results obtained were in agreement with the reference values from the parallel single-analyte test. This paper-based microfluidic origami CL detection system provides a new strategy for a low-cost, sensitive, simultaneous multiplex immunoassay and point-of-care diagnostics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号