1.
Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples.In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 μL utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 × 250 μL elution solution and then with 3 × 250 μL washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS.  相似文献   

2.
This work presents a new methodology to quantify ethyl carbamate (EC) in fortified wines. The presented approach combines the microextraction by packed sorbent (MEPS), using a hand-held automated analytical syringe, with one-dimensional gas chromatography coupled with mass spectrometry detection (GC–MS). The performance of different MEPS sorbent materials was tested, namely SIL, C2, C8, C18, and M1. Also, several extraction solvents and the matrix effect were evaluated. Experimental data showed that C8 and dichloromethane were the best sorbent/solvent pair to extract EC. Concerning solvent and sample volumes optimization used in MEPS extraction an experimental design (DoE) was carried out. The best extraction yield was achieved passing 300 μL of sample and 100 μL of dichloromethane. The method validation was performed using a matrix-matched calibration using both sweet and dry fortified wines, to minimize the matrix effect. The proposed methodology presented good linearity (R2 = 0.9999) and high sensitivity, with quite low limits of detection (LOD) and quantification (LOQ), 1.5 μg L−1 and 4.5 μg L−1, respectively. The recoveries varied between 97% and 106%, while the method precision (repeatability and reproducibility) was lower than 7%. The applicability of the methodology was confirmed through the analysis of 16 fortified wines, with values ranging between 7.3 and 206 μg L−1. All chromatograms showed good peak resolution, confirming its selectivity. The developed MEPS/GC–MS methodology arises as an important tool to quantify EC in fortified wines, combining efficiency and effectiveness, with simpler, faster and affordable analytical procedures that provide great sensitivity without using sophisticated and expensive equipment.  相似文献   

3.
We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.  相似文献   

4.
Microextraction by packed sorbent (MEPS) is a new format for solid-phase extraction (SPE) that has been miniaturized to work with sample volumes as small as 10 μL. The commercially available presentation of MEPS uses the same sorbents as conventional SPE columns and so is suitable for use with most existing methods by scaling the reagent and sample volumes. Unlike conventional SPE columns, the MEPS sorbent bed is integrated into a liquid handling syringe that allows for low void volume sample manipulations either manually or in combination with laboratory robotics. The key aspect of MEPS is that the solvent volume used for the elution of the analytes is of a suitable order of magnitude to be injected directly into GC or LC systems. This new technique is very promising because it is fast, simple and it requires very small volume of samples to produce comparable results to conventional SPE technique. Furthermore, this technique can be easily interfaced to LC/MS and GC/MS to provide a completely automated MEPS/LC/MS or MEPS/GC/MS system. This extraction technique (MEPS) could be of interest in clinical, forensic toxicology and environmental analysis areas. This review provides a short overview of recent applications of MEPS in clinical and pre-clinical studies for quantification of drugs and metabolites in blood, plasma and urine. The extraction of anti-cancer drugs, β-blockers drugs, local anaesthetics, neurotransmitters and antibiotics from biological samples using MEPS technique will be illustrated.  相似文献   

5.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

6.
This paper describes the development and validation of a new procedure for the simultaneous determination of 41 multi-class priority and emerging organic pollutants in water samples using microextraction by packed sorbent (MEPS) followed by large volume injection–gas chromatography–mass spectrometry (LVI–GC–MS). Apart from method parameter optimization the influence of humic acids as matrix components on the extraction efficiency of MEPS procedure was also evaluated. The list of target compounds includes polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs), bisphenol A (BPA) and selected steroid hormones. The performance of the new at-line microextraction-LVI–GC–MS protocol was compared to standard solid-phase extraction (SPE) and LVI–GC–MS analysis. LODs for 100 mL samples (SPE) ranged from 0.2 to 736 ng L−1 were obtained. LODs for 800 μL of sample (MEPS) were between 0.2 and 266 ng L−1. In the case of MEPS methodology even a sample volume of only 800 μL allowed to detect the target compounds. These results demonstrate the high sensitivity of both procedures which permitted to obtain good recoveries (>75%) for all cases. The precision of the methods, calculated as relative standard deviation (RSD) was below 21% for all compounds and both methodologies. Finally, the developed methods were applied to the determination of target analytes in various samples, including snow and wastewater.  相似文献   

7.
An at-line analysis protocol is presented that allows the determination of four UV filters, two polycyclic musk compounds and caffeine in water at concentration level of ng L−1. The fully automated method includes analytes enrichment by Microextraction by packed sorbent (MEPS) coupled directly to large volume injection-gas chromatography–mass spectrometry. Two common SPE phases, C8 and C18, were examined for their suitability to extract the target substances by MEPS. The analytes were extracted from small sample volumes of 800 μL with recoveries ranging from 46 to 114% for the C8-sorbent and 65–109% for the C18-sorbent. Limits of detection between 34 and 96 ng L−1 enable the determination of the analytes at common environmental concentration levels. Both sorbents showed linear calibration curves for most of the analytes up to a concentration level of 20 ng mL−1. Carryover was minimized by washing the sorbents 10 times with 100 μL methanol. After this thorough cleaning, the MEPS are re-used and up to 70 analyses can be performed with the same sorbent. The fully automated microextraction GC–MS protocol was evaluated for the influence of matrix substances typical for wastewater. Dilution of samples prior to MEPS is recommended when the polar caffeine is present at high concentration. Real water samples were analyzed by the MEPS-GC–MS method and compared to standard SPE.  相似文献   

8.
A needle trap device (NTD) packed with silica composite of multi-walled carbon nanotubes (MWCNTs) prepared based on sol–gel technique was utilized for sampling and analysis of volatile organohalogen compounds (HVOCs) in air. The performance of the NTD packed with MWCNTs/silica composite as sorbent was examined in a variety of sampling conditions and was compared with NTDs packed with PDMS as well as SPME with Carboxen/PDMS-coated fibers. The limit of detection of NTDs for the GC/MS detection system was 0.01–0.05 ng mL−1 and the limit of quantitation was 0.04–0.18 ng mL−1. The RSD were 1.1–7.8% for intra-NTD comparison intended for repeatability of technique. The NTD-MWCNTs/silica composite showed better analytical performances compared to the NTD-PDMS composite and had the same analytical performances when compared to the SPME-Carboxen/PDMS fibers. The results show that NTD-MWCNTs-GC/MS is a powerful technique for active sampling of occupational/environmental pollutants in air.  相似文献   

9.
This study was conducted to better understand the distribution characteristics of methamphetamine and amphetamine in urine and hair specimens collected from alleged methamphetamine users in the local population. It is anticipated that the data hereby obtained will be helpful to the interpretation of the time and pattern of drug use. Eight alleged methamphetamine-using arrestees from Keelung Police Department (north of Taipei, Taiwan) consented to contribute both urine and hair specimens. Each arrestee contributed seven urine specimens collected at 0, 12, 24, 48, 72, 96, and 120 h, respectively, after the arrest. Hair specimens were cut into 2-cm sections. The limits of detection and quantitation of the urine protocol were 40 and 50 ng/mL, respectively, for both amphetamine and methamphetamine, while the corresponding limits of detection and quantitation for the hair protocol were 0.8 and 1.0 ng/mg, respectively. The concentration variations of methamphetamine and amphetamine in the urine specimens exhibited three distinct patterns: (a) continuous decrease in the analytes’ concentrations for specimens collected at hours 0-120; (b) increase in the analytes’ concentrations in specimens collected at hours 0-12, followed by decrease; (c) increase in analytes’ concentrations in specimens collected at later times. Together with the amphetamine/methamphetamine concentration ratios found in these urine specimens, the observed trends in the changes of the analytes’ concentrations are helpful for the interpretation on the time of drug use. Unlike urine specimens, amphetamine/methamphetamine concentration ratios in various hair specimens and hair sections remain relatively constant.  相似文献   

10.
A simple, rapid and sensitive method based on microextraction in packed syringe (MEPS), in combination with gas chromatography–mass spectrometry (GC–MS) was developed. Polyaniline (PANI) nanowires network was synthesized and used as sorbent of MEPS for the multiresidue determination of selected analytes from triazine, organochlrorine and organophosphorous pesticides in aqueous samples. The PANI nanowires network was prepared using soft template technique and its characterization was studied by scanning electron microscopy (SEM). The presence of micelles in this methodology showed to be an important parameter in shaping the growing polymer. Hexadecyltrimethylammonium bromide (HTAB) was used as structure directing agent in PANI preparation procedure and this was led to the formation of nanowires with diameters ranging from 35 nm to 45 nm. The synthesized PANI nanowires network showed higher extraction capability in comparison with the bulk PANI. Important parameters influencing the extraction and desorption processes including desorption solvent, elution volume, draw–eject cycles of sample, draw–eject mode, pH effect and amount of sorbent were optimized. Limits of detection were in the range of 0.07–0.3 ng mL−1 using time scheduled selected ion monitoring (SIM) mode. The linearity of method was in the range from 0.5–200 ng mL−1 to 0.2–1000 ng mL−1. The method precision (RSD %) with three replicates were in the range of 5.3–18.4% at the concentration level of 5 ng mL−1. The developed method was successfully applied to the Zayandeh-rood river water samples and the matrix factor obtained for the spiked real water samples were in the range of 0.79–0.94.  相似文献   

11.
A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography–mass spectrometry (GC–MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30 min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods.  相似文献   

12.
In this work the development and validation of a new procedure for the simultaneous determination of 9 nitro and polycyclic musk compounds: musk ambrette (MA), musk ketone (MK), musk mosken (MM), celestolide (ADBI), phantolide (AHMI), tonalide (AHTN), traseolide (ATII), cashmeran (DPMI) and galaxolide (HHCB) in environmental water samples (estuarine and wastewater) using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography–mass spectrometry (LVI-GC–MS) was carried out. Apart from the optimization of the different variables affecting MEPS (i.e., nature of the sorbent, nature of the solvent elution, sample load, and elution/injection volume) extraction recovery was also evaluated, not only for water samples but also for environmental water matrices such as estuarine and waste water. The use of two deuterated analogs ([2H3]-AHTN and [2H15]-MX) was successfully evaluated in order to correct matrix effect in complex environmental matrices such as influent samples from wastewater treatment plants. Method detection limits (MDLs) ranged from 5 to 25 ng L−1, 7 to 39 ng L−1 and 8 to 84 ng L−1 for influent, effluent and estuarine samples, respectively. Apparent recoveries were higher than 75% for all target compounds in all the matrices studied (estuarine water and wastewater) and the precision of the method, calculated as relative standard deviation (RSD), was below 13.2% at 200 ng L−1 concentration level and below 14.9% at low level (20 ng L−1 for all the target analytes, except for AHTN which was set at 40 ng L−1 and HHCB at 90 ng L−1, due to the higher MDL values presented by those target compounds). Finally, this MEPS procedure was applied to the determination of the target analytes in water samples, including estuarine and wastewater, from two estuaries, Urdaibai (Spain) and Adour (France) and an established stir-bar sorptive extraction-liquid desorption/large volume injection-gas chromatography–mass spectrometry (SBSE-LD/LVI-GC–MS) method was performed in parallel for comparison. Results were in good agreement for all the analytes determined, except for DPMI.  相似文献   

13.
The use of steroid hormones as growth promoters in cattle has been banned within the European Union since 1988 but can still be fraudulently employed in animal breeding farms for anabolic purposes. If an efficient monitoring of synthetic compounds (screening and confirmation) is ensured today by many laboratories, pointing out suspicious samples from a natural steroids abuse remains a tricky challenge due to the difficulty to set relevant threshold levels for these endogenous compounds. The development of focused profiling or untargeted metabolomic approaches is then emerging in this context, with the objective to reveal potential biomarkers signing an exogenous administration of such natural steroids. This study aimed to assess sample preparation procedures based on microextraction and adapt them to high throughput urinary profiling or metabolomic analyses based on gas chromatography–mass spectrometry measurement. Two techniques have been tested and optimised, namely solid phase microextraction (SPME) and microextraction by packed sorbent (MEPS), using five model steroid metabolites (16α-hydroxyandrosterone, 2α-hydroxytestosterone, 11-keto,5β-androstanedione, 6α-hydroxyestradiol and 7β-hydroxypregnenolone). The considered performance criteria included not only the absolute response of the targeted compounds but also the robustness of the materials, and the global aspect of the diagnostic ion chromatograms obtained. After only five successive urinary extractions, a clear degradation of the SPME fiber was observed which led to discard this method as a relevant technique for profiling, whereas no degradation was observed on MEPS sorbent. Repeatability and recovery yields were calculated from urine samples fortified at 500 μg L−1 and extracted by MEPS. They were found respectively below 11% and above 60% for all model compounds. Detection limits were in the 5–15 μg L−1 range depending on the compounds, and a good linearity was observed on the 10–75 μg L−1 range (R2 > 0.99). This methodology was applied on urine samples collected from control versus androstenedione-treated bovines, revealing a significant concentration increase for several well-known metabolites such as etiocholanolone, 5α-androstane-3β,17α-diol, 5β-androstane-3α,17α-diol and 5-androstene-3β,17α-diol. Finally, these results allowed to confirm the suitability of the developed strategy and give to this new MEPS application a promising interest in the field of GC–MS based steroid profiling and metabolomic.  相似文献   

14.
A gas chromatography/mass spectrometry (GC/MS) method was developed and validated for the determination of common drugs of abuse in Asia. The method was able to simultaneously quantify amphetamines (amphetamine; AP, methamphetamine; MA, methylenedioxy amphetamine; MDA, methylenedioxymeth mphetamine; MDMA, methylenedioxy ethylamphetamine; MDEA), ketamine (ketamine; K, norketamine; NK), and opiates (morphine; MOR, codeine; COD, 6-acetylmorphine; 6-AM) in human hair. Hair samples (25 mg) were washed, cut, and incubated overnight at 25 degrees C in methanol/trifluoroacetic acid (methanol/TFA). The samples were extracted by solid-phase extraction (SPE), derivatized using heptafluorobutyric acid anhydride (HFBA) at 70 degrees C for 30 min, and the derivatives were analyzed by electron ionization (EI) GC/MS in selected ion monitoring mode. Confirmation was accomplished by comparing retention times and the relative abundances of selected ions with those of standards. Deuterated analogs of the analytes were used as internal standards for quantification. Calibration curves for ten analytes were established in the concentration range 0.1-10 ng/mg with high correlation coefficients (r2 > 0.999). The intra-day and inter-day precisions were within 12.1% and 15.8%, respectively. The intra-day and inter-day accuracies were between -8.7% and 10.7%, and between -5.9% and 13.8%, respectively. The limit of detection (LOD) and limit of quantification (LOQ) obtained were 0.03 and 0.05 ng/mg for AP, MA, MDA, MDMA and MDEA; 0.05 and 0.08 ng/mg for K, NK, MOR and COD; and 0.08 and 0.1 ng/mg for 6-AM. The recoveries were above 88.6% for all the compounds, except K and NK which were in the range of 71.7-72.7%. Eight hair samples from known polydrug abusers were examined by this method. These results show that the method is suitable for broad-spectrum drug testing in a single hair specimen.  相似文献   

15.
This study describes a fully automated procedure using alkaline hydrolysis and headspace (HS) solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatographic (GC)-mass spectrometric (MS) detection of amphetamine, methamphetamine, methylendioxyamphetamine, methylendioxymethamphetamine, methylendioxyethylamphetamine, methylendioxyphenylbutanamine, and methylmethylendioxyphenylbutanamine in human hair samples. Ten milligrams of hair is washed with deionized water, petroleum ether, and dichloromethane. After the addition of deuterated internal standards the sample is hydrolyzed with sodium hydroxide and directly submitted to HS-SPME. After the absorption of analytes for an on-fiber derivatization procedure the fiber is directly placed into the HS of a second vial containing N-methyl-bis(trifluoroacetamide) before GC-MS analysis. The limits of detection are determined between 0.01 and 0.17 ng/mg. Absolute analyte recoveries are in the range between 0.3% and 7.5%. Linearity is proven over a range from 0.1 to 50 ng/mg with coefficients of correlation from 0.998 to 1. In comparison with conventional methods of hair analysis, this fully automated HS-SPME-GC-MS procedure is substantially faster and easier to perform without using solvents. It uses minimal sample amounts and has the same degree of sensitivity and reproducibility.  相似文献   

16.
Molecularly imprinted polymer (MIP) has been synthesized by precipitation polymerization using ciprofloxacin (CIP) as template for the analysis of fluoroquinolone antibiotics (FQs). This MIP material was packed as sorbent in a device for microextraction by packed sorbent (MEPS) combined with liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the analysis of selected FQs drugs including CIP, norfloxacin (NOR) and ofloxacin (OFLO) in municipal wastewater samples. In comparison to the new MIP-MEPS procedure, the target compounds were also determined by solid-phase extraction (MISPE) using the new molecular imprinted polymer material to validate the new MIP-MEPS method. The ability of the MIP for molecular recognition of CIP, NOR and OFLO was proved in presence of structurally different environmental relevant substances such as quinolones (Qs), flumequine (FLU), di(methyl)phthalate (DMP), technical 4-nonylphenol (NP), caffeine, Galaxolide®, Tonalid®, di(butyl)phthalate (DBP), Triclosan, bisphenol-A (BPA), carbamazepine, di(ethylhexyl)phthalate (DEHP), estradiol and octocrylene. The analysis of wastewater samples revealed the high selectivity of the synthesized polymer which was able to recognize and retain the target analytes by both extraction methods, the offline SPE with MIP material and the semi-automated MEPS packed with MIP material.  相似文献   

17.
孟品佳 《应用化学》2014,31(1):103-108
根据海洛因和甲基苯丙胺滥用者毛发中毒品及其代谢物的分布特点,通过实验比较了两类毒品滥用者毛发的分析特点。 海洛因吸食者毛发采用甲醇超声释放待测物,而后直接调整pH值进行液相萃取,萃取物挥干后进行衍生化并进行GC/MS检测;甲基苯丙胺吸食者毛发在碱性条件下消解,然后采用小体积萃取,直接在提取液中衍生化,并进行GC/MS检测。 通过空白毛发标准添加6-单乙酰吗啡、吗啡和可待因进行分析,3种鸦片类毒品最小检测限均小于 3 μg/g,RSD(n=5)为2.5%~9.6%;通过空白毛发标准添加苯丙胺、甲基苯丙胺、3,4-(亚甲二氧基)苯丙胺和3,4-(亚甲二氧基)-甲基苯丙胺进行分析,4种苯丙胺类毒品的最小检测限为0.05 μg/g,RSD(n=5)为5%~14%。  相似文献   

18.
Summary A very simple method for the analysis of methamphetamine and amphetamine in human whole blood and urine by headspace gas chromatography (GC) has been presented. It neither needs solid-phase microextraction nor cryogenic trapping devices, but only a conventional capillary GC instrument with flame ionization detection (FID). The two special points to be mentioned in this method are the in-matrix derivatization of amphetamines for vaporization and the capability of injection of as large as 5 mL of the headspace vapor into a GC instrument in the splitless mode for sensitive detection. After heating a whole blood or urine sample containing amphetamines, -methylbenzylamine (internal standard, IS) and heptafluoro-n-butyryl chloride under alkaline conditions in a 7.0-mL vial at 90 °C for 20 min, 5 mL of the headspace vapor was drawn with a glass syringe and injected into the gas chromatograph. During injection the column was at 40 °C to trap the analytes, and then the oven temperature was programmed up to 320 °C. Sharp peaks were obtained for each analyte and IS, and only a relatively small number of background impurity peaks for the whole blood and urine samples. The detection limits for each amphetamine were estimated to be 0.1 g mL–1 for whole blood and 0.03 g mL–1 for urine. Precision and linearity were also tested to confirm the reliability. Methamphetamine and amphetamine could be determined from whole blood and urine obtained at autopsy in three methamphetamine poisoning cases. The identity of each peak appearing in the gas chromatograms was confirmed by GC/mass spectrometry.  相似文献   

19.
The potential of carbon nanocones/disks as sorbent material in solid-phase extraction (SPE) procedures has been evaluated. For this aim, a model analytical problem, the determination of chlorophenols in water samples, was selected. An accurately weighed amount of 20 mg of purified carbon nanocones/disks was packed in 3 mL commercial SPE cartridges. Once conditioned, up to 8 mL of water samples can be preconcentrated without analyte losses. The chlorophenols were eluted by using 200 μL of hexane. Aliquots of 2 μL of the organic extract were injected in the gas chromatograph–mass spectrometer for separation and quantification. The purification of the commercial nanocones/disks to reduce the presence of amorphous carbon has been successfully achieved by heating the carbon nanocones/disks at 450 °C for 20 min. Detection limits of chlorophenols were in the range 0.3–8 ng mL−1 by using 2 mL of sample. Moreover, excellent average recovery values (98.8–100.9%) have been obtained after the analysis of water samples from different nature. Finally, the performance of the carbon nanocones/disks as sorbent material has been compared with that of multiwalled carbon nanotubes, providing the former better results under the experimental conditions assayed.  相似文献   

20.
A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L−1, good repeatability (RSD < 7.5% for MAP, and <11.5% for AP, n = 6), and low detection limits (0.1 μg L−1 for MAP and 0.5 μg L−1 for AP). Feasibility of the method was evaluated by analyzing human urine samples. Although IL-based SPME is still at the beginning of its development stage, the results obtained by this work showed that it is a promising simple, fast and sensitive sample preparation method.  相似文献   