首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Cheng HL  Jong YJ  Li JH  Ko WK  Wu SM 《Electrophoresis》2006,27(23):4711-4716
Direct analysis of methamphetamine, amphetamine, and p-hydroxymethamphetamine in urine was achieved by cation-selective exhaustive injection and sweeping micellar EKC. A bare fused-silica capillary (40 cm, 50 microm id) was filled with phosphate buffer (80 mM, pH 3, containing 20% ACN). Then a high-conductivity buffer (100 mM phosphate, pH 3; 6.9 kPa for 2.5 min) was injected. Samples were loaded using electrokinetic injection (10 kV, 600 s) which created long zones of cationic analytes. To enhance sensitivity by sweeping, the stacking step was performed using a phosphate buffer (50 mM, pH 3, containing 20% ACN and 100 mM SDS) at -20 kV before separation by MEKC. This method was capable of detecting the analytes at ppb levels. The calibration plots were linear (r(2) >or= 0.9948) over a range of 100-5000 ng/mL for methamphetamine, and 100-2000 ng/mL for amphetamine and p-hydroxymethamphetamine. The LODs (S/N = 3) were 20 ng/mL for methamphetamine, and 15 ng/mL for amphetamine and p-hydroxymethamphetamine. The method was applied to analysis of 14 urine samples of addicts and is suitable for screening suspected samples for forensic purposes. The results showed good agreement with fluorescence polarization immunoassay and GC-MS.  相似文献   

2.
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.  相似文献   

3.
Lin YH  Chiang JF  Lee MR  Lee RJ  Ko WK  Wu SM 《Electrophoresis》2008,29(11):2340-2347
A cation-selective exhaustive injection and sweeping micellar EKC (CSEI-Sweep-MEKC) was established to analyze morphine and its four metabolites, including codeine, normorphine (NM), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). After SPE, the urine samples were analyzed by this CE method. The phosphate buffer (75 mM, pH 2.5) containing 30% methanol was first filled into an uncoated fused-silica capillary (40 cm, 50 microm id), then a high-conductivity buffer (120 mM phosphate, 10.3 kPa for 99.9 s) followed. The pretreated urine sample was loaded by electrokinetic injection (10 kV, 600 s). The stacking and separation were performed by using phosphate buffer (25 mM, pH 2.5) containing 22% methanol and 100 mM SDS at -20 kV, and detected at 200 nm. During method validation, calibration plots were linear (r > or = 0.998) over a range of 30-3000 ng/mL for morphine, NM, and codeine, 100-2000 ng/mL for M6G, and 80-3200 ng/mL for M3G. The LODs (S/N = 5, sampling 600 s at 10 kV) were 10 ng/mL for morphine, NM, and codeine, 35 ng/mL for M6G, and 25 ng/mL for M3G. This stacking CE method could increase 2500-fold sensitivity of codeine, when comparing with CZE. Five addicts' urine specimens were analyzed. Their results were compared with those of LC-MS-MS, and showed good coincidence. This method could be feasible for monitoring morphine and its metabolites in forensic interest and pharmacokinetic investigations.  相似文献   

4.
In this study, we present a capillary electrochromatographic method for separation of basic compounds of interest in forensic science (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, cocaine, codeine, heroin, morphine, and 6-monoacethylmorphine). Several analytical conditions were taken into account to completely separate in the same run the 10 drugs of abuse analyzed. Chromatographic retention, selectivity and efficiency were evaluated in dependence of the type of stationary phase (CN and RP-C18 derivatized silica particles), mobile phase composition, buffer type and pH, sample injection. The optimum separation parameters were set up using a mixture of aqueous sodium phosphate buffer (pH 2.5)/acetonitrile (80/20, v/v) as the mobile phase, 10 kV and 20 °C as applied voltage and capillary temperature, respectively. Under these conditions all the studied analytes were baseline resolved within 20 min. The method performance was investigated in terms of precision, linearity, sensitivity and accuracy to demonstrate the applicability of the developed capillary electrochromatographic system to forensic analysis. Calibration curves provided a good linearity over a working range of 100–1200 ng/mL for all analytes. Limits of detection and quantification were in the range 5–12 ng/mL and 10–30 ng/mL, respectively. Then the method was applied to the analysis of a human urine sample spiked with a basic compounds’ mixture. Urine samples’ pre-treatment was carried out through a solid phase extraction (SPE) procedure on strong cation exchange (SCX) cartridges.  相似文献   

5.
Cation‐selective exhaustive injection and sweeping followed by a MEKC separation is evaluated for the sensitive analysis of 5‐nitroimidazoles in untreated human serum and urine. Deproteinized serum and urine samples were diluted 76 and 143 times, respectively, in a low‐conductivity solvent (5.00 mM orthophosphoric acid containing 5.0% v/v methanol). Samples were electrokinetically injected at 9.8 kV for 632 s in a previously conditioned fused‐silica capillary (65.0 cm × 50 μm id). Separation was performed at –30 kV and 20°C using 44 mM phosphate buffer (pH 2.5), 123 mM SDS, and 8% v/v tetrahydrofurane as BGE. Signals were monitored at 276 nm and peak area was selected as analytical response. Good linearity (R2 ≥ 0.988) and LODs lower than 1.5 and 1.8 μg/mL were achieved in serum and urine, respectively.  相似文献   

6.
《Electrophoresis》2018,39(16):2099-2106
A method consisting of cation‐selective exhaustive injection and sweeping (CSEI‐sweeping) as online preconcentration followed by a cyclodextrin modified electrokinetic chromatography (CDEKC) enantioseparation has been developed for the simultaneous determination of two brompheniramine enantiomers in rat plasma. In this method, analytes were electrokinetically injected at a voltage of 8 kV for 80 s in a fused‐silica capillary. Prior to the injection, the capillary was rinsed with 50 mM phosphate buffer of pH 3.5, followed by a plug of a higher conductivity buffer (150 mM phosphate pH 3.5, 20 psi, 6 min) and a plug of water (0.5 psi, 5 s). Separation was carried out applying –20 kV in 50 mM phosphate buffer, pH 3.5, containing 10% v/v ACN and 30 mg/mL sulfated‐β‐cyclodextrin (S‐β‐CD). Analytical signals were monitored at 210 nm. The detection sensitivity of brompheniramine enantiomers was enhanced by about 2400‐fold compared to the normal injection mode (hydrodynamic injection for 3 s at 0.5 psi, with a BGE of 50 mM phosphate buffer containing 20 mg/mL S‐β‐CD at pH 3.5), and LLOQ of two enantiomers were both 0.0100 μg/mL. In addition, this method had fairly good repeatability and showed promising capabilities in the application of stereoselective pharmacokinetic investigations for brompheniramine enantiomers in rat.  相似文献   

7.
A new CE system based on the use of polymeric-mixed micelles (cholic acid, SDS and the poloxamine Tetronic(?) 1107) was developed for the simultaneous determination of nine steroids in human urine. This method allows the baseline separation and quantitation of cortisol, androstenedione, estriol, dehydroepiandrosterone sulfate, testosterone, dehydroepiandrosterone, estrone, progesterone and estradiol in less than 25 min showing to be sensitive enough to detect low concentrations of these steroids in urine samples (5-45 ng/mL). The optimized electrophoretic conditions were performed using a 50 cm × 75 μm capillary, 18 kV, 25°C, with 44 mM cholic acid, 10 mM SDS, 0.05% w/v tetronic(?) 1107, 2.5% v/v methanol, 2.5% v/v tetrahydrofuran in 5 mM borate - 5 mM phosphate buffer (pH=8.0) as a background electrolyte and a dual 210/254 UV-detection. The method can simultaneously determine 0.1-120 μg/mL, which corresponds to 5-6000 ng/mL of steroids in 2 mL urine. The recoveries ranged between 82.4 and 101.5%. Due to its simplicity, speed, accuracy and reliability, the proposed method could be a potential alternative to the traditional methodologies used with clinical purposes.  相似文献   

8.
This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid–liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at ?20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r?≥?0.990) over a range of 50–1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n?=?3) and inter-day (n?=?5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N?=?5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.  相似文献   

9.
Lan Zhang  Jinfeng Chen  Yu He  Guonan Chen 《Talanta》2009,77(3):1002-2154
A simple, rapid and low-costing new mixed surfactant MEKC method has been developed for the analysis of five neutral anabolic steroids in this paper. It was found that the bile salt coupling with Triton X-100 was a suitable bi-micellar surfactant for the separation of these anabolic steroids with similar structure. The separation conditions were optimized in detail. The five natural and synthetic anabolic steroids, such as androstenedione (AD), 19-norandrostenedione (NAD), 1,4-androstadiene-3,17-dione (ADD), methandrostenolone (MA) and methyltestosterone (MT) were separated and detected in an alkaline buffer system (pH 9.0) containing 15 mM Britton-Robinson (BR) buffer, 50 mM sodium cholate (SC) and 0.1% (v/v) Triton X-100 with detection wavelength at 241 nm and 18 kV of separation voltage. Under the optimal conditions, five coexistence neutral steroids were completely separated within 12 min with the detection limits ranged from 0.20 to 0.51 μg/mL. This method was successfully used for detection and confirmation of the anabolic steroid methandrostenolone in methandrostenolone tablets and in the real human urine, GC-MS method was applied to confirm the free methandrostenolone existence in the urine sample in order to validate the reliability of MEKC method.  相似文献   

10.
Three strategies were investigated for the simultaneous separation and on-line preconcentration of charged and neutral hypolipidaemic drugs in micellar electrokinetic chromatography (MEKC). A background electrolyte (BGE) consisting of 20 mM ammonium bicarbonate buffer (pH 8.50) and 50 mM sodium dodecyl sulfate (SDS) was used for the separation and on-line preconcentration of the drugs. The efficiencies of sweeping, analyte focusing by micelle collapse (AFMC), and simultaneous field-amplified sample stacking (FASS) and sweeping, were compared for the preconcentration of eight hypolipidaemic drugs in different conductivity sample matrices. When compared with a hydrodynamic injection (5 s at 50 mbar, 0.51% of capillary volume to detection window) of drug mixture prepared in the separation BGE, improvements of detection sensitivity of 60-, 83-, and 80-fold were obtained with sweeping, AFMC and simultaneous FASS and sweeping, respectively, giving limits of detection (LODs) of 50, 36, and 38 μg/L, respectively. The studied techniques showed suitability for focusing different types of analytes having different values of retention factor (k). This is the first report for the separation of different types of hypolipidaemic drugs by capillary electrophoresis (CE). The three methods were validated then applied for the analysis of target analytes in wastewater samples from Hobart city.  相似文献   

11.
Chiral separation method development is usually very time-consuming due to the diversity in chemical structures of pharmaceutical drug substances as well as the suitable separation conditions and the problem to choose the appropriate chiral selector. This paper shows capillary zone electrophoresis (CZE) which was developed for chiral separation of a basic compound - rivastigmine (RIV) using 30 cm × 50 μm i.d. polyacrylamide (PAA)-coated fused-silica capillary (effective length 20 cm), amine-modified phosphate buffer of pH 2.5 and sulfated-β-CD (S-β-CD) as chiral selector. Other selected native or derivatized cyclodextrins (CDs) were also tested: β-CD (5, 30 mM), carboxymethyl-β-CD (5, 30 mM), dimethyl-β-CD (15 mM), hydroxypropyl-β-CD (5, 30 mM), hydroxypropyl-α-CD (5, 30 mM) and hydroxypropyl-γ-CD (5, 30 mM). Complete enantiomeric separation of RIV was achieved at 20 kV, 18 °C and detection at 200 nm within 8 min with R.S.D. for the absolute migration time reproducibility of less than 2.1%. Rectilinear calibration range was 5.0-500.0 μM of each enantiomer (r = 0.9994-0.9995). The CZE method proposed was used for the control of chiral purity of pharmaceutically active S-RIV and for the analysis of Exelon caps preparation.  相似文献   

12.
One CE method was established for detecting deferoxamine (DFO) and deferiprone (DFR) in plasma. For β‐thalassemia patients, DFO and DFR are major medicines to treat the iron overload caused by blood transfusion. Field‐amplified sample injection combined with sweeping was used for sensitivity enhancement in CE. This method was performed on an uncoated fused‐silica capillary. After liquid–liquid extraction, the plasma samples were electrokinetically injected into capillary at +10 kV for 180 s. The phosphate buffer (100 mM) containing 50 mM triethanolamine was used as the BGE (pH 6.6). Separation buffer was phosphate buffer (100 mM, pH 3.0) containing 150 mM SDS. This method showed good linearity (r ≥ 0.9960). Precision and accuracy were evaluated by the results of RSD and relative error of intrabatch and interbatch analyses, and all of the absolute values were less than 6.12%. The LODs (S/N = 3) were 200 ng/mL for DFO, and 25 ng/mL for DFR. The LOQ (S/N = 10) of DFO and DFR were 600 and 75 ng/mL, respectively. This method was applied for clinical applications of five β‐thalassemia patients.  相似文献   

13.
An improved analytical scheme for human milk neutral oligosaccharides determination was developed, in which, the oligosaccharides were pooled in two fractions (pools 1 and 2) after gel filtration, and then were quantitatively derivatized with a single fluorescent reagent, 2-anthranilic acid. Separation was by reversed-phase HPLC on an ODS-100Z column with a mobile phase of 50 mM ammonium acetate pH 4.0 and 150 mM citrate buffer pH 4.5 and monitored by a fluorescence detector at 360 nm excitation and 425 nm emission wavelengths. The method improved on the separation of neutral tetra- and hexa-saccharide isomers, namely, lacto-N-tetraose (LNT) and lacto-N-neotetraose (LNnT) as well as of lacto-N-difucohexaose I (LNDFH I) and lacto-N-difucohexaose II (LNDFH II). The separation of trisacccharide isomers, 3-fucosyllactose (3-FL) and 2′-fucosyllactose (2′-FL) was also successful. Limits of detection and quantification were in the range of 1–10 ng/l and 2–30 ng/l, respectively. The methods’ accuracy was good with its precision at <20% RSD and <1% RSD, respectively, for oligosaccharide concentration and retention time. The recoveries were in the range of 80–100%. This method was successfully applied to the separation and determination of representative neutral oligosaccharide contents in Samoa women milk.  相似文献   

14.
Monitoring of trace impurities in electroplating bath is needed to meet EU requirements for WEEE and RoHS and for quality control of electrodeposits. Methods using IC and 100% aqueous CE buffer were found producing non-repeatable results attributed to interference of surfactants and major methanesulphonate anion. A new CE buffer containing 1.5 mM tetraethylenepentaamine, 3 mM 1,3,5-benzenetricarboxylic acid and 15 mM Tris in 20% (v/v) methanol at pH = 8.4 was shown to enhance the separation window, reduce interaction between buffer and bath constituents, and give satisfactory repeatability with baseline separation for 14 organic and inorganic anions within 14 min, good repeatability for migration time (0.32–0.57% RSD), satisfactory peak area and peak height (2.9–4.5 and 3–4.7% respectively), low detection limit (S/N = 2, 20–150 ppb), and wide working ranges (0.1–100 ppm). The CE buffer with 20% (v/v) methanol has demonstrated its capability for identifying anion impurities causing problem in aged tin bath and the use of only 10-fold dilution to produce reliable results for quality assessment in plating bath containing high surfactant additives.  相似文献   

15.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

16.
A new capillary zone electrophoresis (CZE) method for the separation of omeprazole enantiomers has been developed. Methyl-β-cyclodextrin (methyl-β-CD) was chosen as the chiral selector, and several parameters, such as cyclodextrin structure and concentration, buffer concentration, pH, and capillary temperature were investigated in order to optimize separation and run times. Analysis times, shorter than 8 min were found using a background electrolyte solution consisting of 40 mM phosphate buffer adjusted to pH 2.2, 30 mM β-cyclodextrin and 5 mM sodium disulphide, hydrodynamic injection, and 15 kV separation voltage. Detection limits were evaluated on the basis of baseline noise and were established 0.31 mg/l for the omeprazole enantiomers. The proposed method was applied to five pharmaceutical preparations with recoveries between 84 and 104% of the labeled contents.  相似文献   

17.
In this research, a novel stacking capillary electrophoresis method, repetitive large volume sample injection and sweeping MEKC (rLVSI-sweeping MEKC) were developed to analyze the presence of three androgenic steroids considered as sport doping drugs, testosterone (T), epitestosterone (E) and epitestosterone glucuronide (EG) in urine. This method provides better sensitivity enhancement than the traditional large volume sample stacking-sweeping strategies due to sensitivity enhancement by repetitive injections. This multiple sampling method enhances sensitivity of monitoring of urine samples by UV detection (254 nm). Firstly, the phosphate buffer was filled into an uncoated fused silica capillary and the samples were injected into the capillary at 10 psi for 20 s, and then stacked at −10 kV for 1 min using phosphate buffer containing SDS. The above injecting and stacking steps were repeated five times. Finally, separation was performed at −20 kV, using phosphate buffer containing methanol, SDS and (2-hydroxypropyl)-β-cyclodextrin. Method validation showed that calibration plots were linear (r ≧ 0.997) over a range of 5-200 ng mL−1 for T, 20-200 ng mL−1 for E and 0.5-500 ng mL−1 for EG. The limits of detection were 1.0 ng mL−1 for T, 5.0 ng mL−1 for E and 200.0 pg mL−1 for EG. When evaluating precision and accuracy, values of RSD and RE in intra-day (n = 3) and inter-day (n = 5) analysis were found to be less than 10.0%. Compared with the simple LVSS-sweeping, which is also a stacking strategy, this method further improves sensitivity up to 25 folds (∼2500 folds with MEKC without preconcentration). This method was applied to monitor 10 athletes’ urine, and did not detect any analyte. The novel stacking method was feasible for monitoring of doping by sportsmen.  相似文献   

18.
We have developed a reversed-phase high-performance liquid chromatography-pulsed amperometric detection (RP-HPLC-PAD) method for the detection of albiflorin and paeoniflorin in Paeoniae Radix and Wu-ji-san. Albiflorin and paeoniflorin were completely separated using 10% acetonitrile in 5 mM sodium phosphate buffer (pH 3.0) as an eluent and detected by PAD under alkaline conditions after using a post-column delivery system. The limit of detection (S/N = 3) and the limit of quantification (S/N = 10) were 0.10 and 0.35 ng for albiflorin, and 0.20 and 0.50 ng for paeoniflorin, respectively. The coefficients of linear regression were 0.9995 and 0.9999 for concentrations between 0.035 and 100 μg/mL. The intra- and inter-day precision (RSDs) was less than 3.56% in Paeoniae Radix and Wu-ji-san. The average recoveries from Paeoniae Radix and Wu-ji-san were 99.01–100.94% and 99.46–100.64%. This method shows higher selectivity than HPLC–UV method for analyzing albiflorin and paeoniflorin in Chinese medicinal preparation.  相似文献   

19.
A rapid and simple method was demonstrated for the analysis of atropine, anisodamine, and scopolamine by nonaqueous capillary electrophoresis (NACE) coupled with electrochemiluminescence (ECL) and electrochemistry (EC) dual detection. The mixture of acetonitrile (ACN) and 2-propanol containing 1 M acetic acid (HAc), 20 mM sodium acetate (NaAc), and 2.5 mM tetrabutylammonium perchlorate (TBAP) was used as the electrophoretic buffer. Although a short capillary of 18 cm was used, the decoupler was not needed and the separation efficiency was good. The linear ranges of atropine, anisodamine, and scopolamine were 0.5–50, 5–2000, and 50–2000 μM, respectively. For six replicate measurements of 100 μM scopolamine, 15 μM atropine, and 200 μM anisodamine, the RSDs of ECL intensity, EC current, and migration time were less than 3.6%, 4.5%, and 0.3%, respectively. In addition, because the organic buffer was used, the working electrode (Pt) was not easily fouled and did not need reactivation. The method was also applied for the determination of these three alkaloids in Flos daturae extract.  相似文献   

20.
Development and validation of a method for simultaneous identification and quantification of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), cannabinol (CBN), and metabolites 11-hydroxy-THC (11-OH-THC) and 11-nor-9-carboxy-THC (THCCOOH) in oral fluid. Simultaneous analysis was problematic due to different physicochemical characteristics and concentration ranges. Neutral analytes, such as THC and CBD, are present in ng/mL, rather than pg/mL concentrations, as observed for the acidic THCCOOH biomarker in oral fluid. THCCOOH is not present in cannabis smoke, definitively differentiating cannabis use from passive smoke exposure. THC, 11-OH-THC, THCCOOH, CBD, and CBN quantification was achieved in a single oral fluid specimen collected with the Quantisal™ device. One mL oral fluid/buffer solution (0.25 mL oral fluid and 0.75 mL buffer) was applied to conditioned CEREX® Polycrom™ THC solid-phase extraction (SPE) columns. After washing, THC, 11-OH-THC, CBD, and CBN were eluted with hexane/acetone/ethyl acetate (60:30:20, v/v/v), derivatized with N,O-bis-(trimethylsilyl)trifluoroacetamide and quantified by two-dimensional gas chromatography electron ionization mass spectrometry (2D-GCMS) with cold trapping. Acidic THCCOOH was separately eluted with hexane/ethyl acetate/acetic acid (75:25:2.5, v/v/v), derivatized with trifluoroacetic anhydride and hexafluoroisopropanol, and quantified by the more sensitive 2D-GCMS–electron capture negative chemical ionization (NCI-MS). Linearity was 0.5–50 ng/mL for THC, 11-OH-THC, CBD and 1–50 ng/mL for CBN. The linear dynamic range for THCCOOH was 7.5–500 pg/mL. Intra- and inter-assay imprecision as percent RSD at three concentrations across the linear dynamic range were 0.3–6.6%. Analytical recovery was within 13.8% of target. This new SPE 2D-GCMS assay achieved efficient quantification of five cannabinoids in oral fluid, including pg/mL concentrations of THCCOOH by combining differential elution, 2D-GCMS with electron ionization and negative chemical ionization. This method will be applied to quantification of cannabinoids in oral fluid specimens from individuals participating in controlled cannabis and Sativex® (50% THC and 50% CBD) administration studies, and during cannabis withdrawal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏