首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography–mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500 μg L−1 could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12 μg L−1 for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237 μg L−1 (3,5-DCP) to 0.3623 μg L−1 (2,3,6-TCP).  相似文献   

2.
A simple and rapid analytical method based on in-matrix ethyl chloroformate (ECF) derivatization has been developed for the quantitative determination of bisphenol-A (BPA) in milk and water samples. The samples containing BPA were derivatised with ECF in the presence of pyridine for 20 s at room temperature, and the non-polar derivative thus formed was extracted using polydimethylsiloxane solid-phase microextraction (SPME) fibres with thicknesses of 100 μm followed by analysis using gas chromatography–mass spectrometry. Three alkyl chloroformates (methyl, ethyl and isobutyl chloroformate) were tested for optimum derivatisation yields, and ECF has been found to be optimum for the derivatisation of BPA. Several parameters such as amount of ECF, pyridine and reaction time as well as SPME parameters were studied and optimised in the present work. The limit of detection for BPA in milk and water samples was found to be 0.1 and 0.01 μg L−1, respectively, with a signal-to-noise ratio of 3:1. The limit of quantitation for BPA in milk and water was found to be 0.38 and 0.052 μg L−1, respectively, with a signal-to-noise ratio of 10:1. In conclusion, the method developed was found to be rapid, reliable and cost-effective in comparison to silylation and highly suitable for the routine analysis of BPA by various food and environmental laboratories.  相似文献   

3.
Hollow-fiber liquid-phase microextraction (HF-LPME), a relatively new sample preparation technique, has attracted much interest in the field of environmental analysis. In the current study, a novel method based on hollow-fiber liquid-phase microextraction with in situ derivatization and gas chromatography–mass spectrometry for the measurement of triclosan in aqueous samples is described. Hollow-fiber liquid-phase microextraction conditions such as the type of extraction solvent, the stirring rate, the volume of derivatizing reagent, and the extraction time were investigated. When the conditions had been optimized, the linear range was found to be 0.05–100 μg l−1 for triclosan, and the limit of detection to be 0.02 μg l−1. Tap water and surface water samples collected from our laboratory and Wohushan reservoir, respectively, were successfully analyzed using the proposed method. The recoveries from the spiked water samples were 83.6 and 114.1%, respectively; and the relative standard deviation (RSD) at the 1.0 μg l−1 level was 6.9%.  相似文献   

4.
A new approach using single-drop microextraction (SDME) and gas chromatography–mass spectrometry for the determination of six haloacetic acids (HAAs) in water samples was presented. n-Octanol was used as extractant and derivatization reagent. HAAs were derivatized both simultaneously during the extraction in the solvent microdrop, and after extraction, inside a glass microvial (1.1 mm I.D.). Trifluoroacetic anhydride (TFAA) was used as the reaction catalyst. The influence of catalyst amount, derivatization time and temperature on the yield of the in-microvial derivatization was investigated. Derivatization reaction was performed using 1.2 μL of TFAA at 100 °C for 20 min. Extraction was performed using 1.8 μL of n-octanol containing TFAA (10%, v/v). Experimental parameters, such as, exposure time, sample pH and extraction temperature were controlled and optimized. Analytical parameters such as linearity, precision and limit of detection were also evaluated. The proposed method was proved to be a suitable analytical procedure for HAAs in water with limits of detection 0.1–1.2 μg/L. The relative recoveries range from 82.5 to 97.6% for all the target analytes. Precision values were from 5.1 to 8.5% (as intra-day relative standard deviation, RSD) and 8.8–12.3% (as inter-day RSD).  相似文献   

5.
A novel technique for derivatization in a gas chromatograph injection port after a one-step extraction of trace perfluorocarboxylic acids (PFCAs) in water with ion pair formation during dispersive liquid–liquid microextraction (DLLME) was investigated. Tetrabutylammonium hydrogen sulfate (TBAHS) was used as the ion pair reagent. PFCA butyl ester derivatives were formed in the GC injection port and then analyzed using gas chromatography coupled to tandem mass spectrometry with negative chemical ionization. According to our analysis, the operative linear range for PFCA detection from 250 pg mL−1 to 2 μg mL−1 with a relative standard derivation (RSD) below 13%. Detection limits were achieved at the level of 37–51 pg mL−1. This method was successfully applied for the analyzing of PFCAs in river water samples from urban and industrial areas without tedious pretreatment. The concentration range over which PFCAs were detected is from 0.6 ng mL−1 to 604.9 ng mL−1.  相似文献   

6.
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid–liquid microextraction coupled GC–MS system. Microextraction efficiency factors have been investigated and optimized: 9 μL 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 °C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 μL of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235–1174, limit of detection of 0.005–0.68 μg/L (S/N = 3) and linearity range of 0.02–300 μg/L have been obtained. A reasonable repeatability (RSD ≤ 10.4%, n = 5) with satisfactory linearity (0.9995 ≥ r2 ≥ 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%.  相似文献   

7.
In this work, solid-phase microextraction coupled with gas chromatography–mass spectrometry was developed to determine trace levels of nitrobenzene compounds in water and soil samples. Graphene was chosen as the extraction material and its composite was coated on a stainless steel wire through sol–gel technique for the solid phase microextraction. The key parameters influencing the extraction efficiency were optimized. Under the optimal conditions, the linearity for the compounds was observed in the range of 0.02–15.0 mg/L for water samples, and 0.2–60.0 mg/kg for soil samples, with the correlation coefficients(r) of 0.9966–0.9987. The limits of detection of the method were 0.0025–0.005 mg/L for water samples, and 0.02–0.04 mg/kg for soil samples. The recoveries for the spiked samples were in the range of 72.0%–113.2%, and the precision, expressed as the relative standard deviations, was less than 12.1%.  相似文献   

8.
In this work, we propose solvent-based de-emulsification dispersive liquid–liquid microextraction (SD-DLLME) as a simple, rapid and efficient sample pretreatment technique for the extraction and preconcentration of organochlorine pesticides (OCPs) from environmental water samples. Separation and analysis of fifteen OCPs was carried out by gas chromatography–mass spectrometry (GC/MS). Parameters affecting the extraction efficiency were systematically investigated. The detection limits were in the range of 2–50 ng L−1 using selective ion monitoring (SIM). The precision of the proposed method, expressed as relative standard deviation, varied between 3.5 and 10.2% (n = 5). Results from the analysis of spiked environmental water samples at the low-ppb level met the acceptance criteria set by the EPA.  相似文献   

9.
10.
This paper describes a novel, simple and environmentally friendly method for rapid determination of the amide herbicides metoalchlor, acetochlor, and butachlor. It is based on dispersive liquid-liquid microextraction and gas chromatography–mass spectrometry. Factors that may influence the enrichment efficiency, such as type and volume of extraction solvent, type and volume of dispersive solvent, extraction time, and content of NaCl, were investigated and optimized in detail. Under the optimum conditions, the limits of detection of metoalchlor, acetochlor, and butachlor were 0.02, 0.04, and 0.003 μg L−1, respectively. The experimental results indicated that there was linearity over the range 0.1–50 μg L−1 and good reproducibility with relative standard deviations over the range 1.6–3.0% (n = 5). The proposed method has been applied for the analysis of real-world water samples, and satisfactory results were achieved. Average recoveries of spiked herbicides were in the range 80.3–108.8%. All of these indicated that the developed method would be an efficient method for simultaneous determination of the three herbicides in environmental water samples.  相似文献   

11.
A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography–mass spectrometry detection (GC–MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol–gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature, extraction time, and desorption conditions were investigated and optimized. The developed method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. Under the optimized conditions, the detection limit of the method was 5 ng L−1 using selected ion monitoring (SIM) mode. The inter-day and intra-day precisions of the developed method under optimized conditions were below 10%, and the method shows linearity in the range of 20 ng L−1 to 500 μg L−1with the correlation coefficient of >0.99. The optimized method was applied to the sampling of phenol from some biologics production areas. The compared results obtained using current and standard methods were shown to be satisfactory.  相似文献   

12.
In this study, a simple and efficient large volume injection gas chromatography–mass spectrometry (GC-MS) method, via a programmable-temperature vaporizer (PTV) inlet, has been developed and applied in the determination of estrogens in environmental water samples without a prior derivatization process. Three commonly used estrogens estrone, 17 β-estradiol and 17 α-ethynylestradiol were selected as target compounds for this study. It has been demonstrated that the type of gas chromatograph liner and the initial inlet temperature can greatly affect the response intensity of estrogens. Three different types of PTV liners have been studied; the multibaffle liner generated the strongest response intensities towards the estrogen analytes. The results showed that the response intensities of estrogens reduced sharply while the initial inlet temperature increased. Various instrument conditions and sample preparation methods were studied in detail. The optimized method has been validated with good linearity, precision and accuracy. The method detection limit of each estrogen was found to be 0.041 ng/L for estrone, 0.046 ng/L for 17 β-estradiol and 0.031 ng/L for 17 α-ethynylestradiol. To the best of our knowledge, these results represent the best sensitivities achieved for estrogens analyzed in water samples via traditional GC-MS method without a derivatization process. This method has been successfully applied in the analyses of different water samples.  相似文献   

13.
A gas chromatography–mass spectrometric (GC–MS) method has been established for the determination of hydrazine in drinking water and surface water. This method is based on the derivatization of hydrazine with ortho-phthalaldehyde (OPA) in water. The following optimum reaction conditions were established: reagent dosage, 40 mg mL−1 of OPA; pH 2; reaction for 20 min at 70 °C. The organic derivative was extracted with methylene chloride and then measured by GC–MS. Under the established condition, the detection and the quantification limits were 0.002 μg L−1 and 0.007 μg L−1 by using 5.0-mL of surface water or drinking water, respectively. The calibration curve showed good linearity with r2 = 0.9991 (for working range of 0.05–100 μg L−1) and the accuracy was in a range of 95–106%, and the precision of the assay was less than 13% in water. Hydrazine was detected in a concentration range of 0.05–0.14 μg L−1 in 2 samples of 10 raw drinking water samples and in a concentration range of 0.09–0.55 μg L−1 in 4 samples of 10 treated drinking water samples.  相似文献   

14.
Membrane-assisted solvent extraction coupled to large volume injection in a programmable temperature vaporisation injector using gas chromatography–mass spectrometry analysis was optimised for the simultaneous determination of a variety of endocrine disrupting compounds in environmental water samples (estuarine, river and wastewater). Among the analytes studied, certain hormones, alkylphenols and bisphenol A were included. The nature of membranes, extraction solvent, extraction temperature, solvent volume, extraction time, ionic strength and methanol addition were evaluated during the optimisation of the extraction. Matrix effects during the extraction step were studied in different environmental water samples: estuarine water, river water and wastewater (influent and effluent). Strong matrix effects were observed for most of the compounds in influent and effluent samples. Different approaches were studied in order to correct or minimise matrix effects, which included the use of deuterated analogues, matrix-matched calibration, standard addition calibration, dilution of the sample and clean-up of the extract using solid-phase extraction (SPE). The use of deuterated analogues corrected satisfactorily matrix effect for estuarine and effluent samples for most of the compounds. However, in the case of influent samples, standard addition calibration and dilution of the sample were the best approaches. The SPE clean-up provided similar recoveries to those obtained after correction with the corresponding deuterated analogue but better chromatographic signal was obtained in the case of effluent samples. Method detection limits in the 5–54 ng L−1 range and precision, calculated as relative standard deviation, in the 2–25% range were obtained.  相似文献   

15.
16.
Single-drop microextraction (SDME) followed by gas chromatography–mass spectrometry detection was used for the determination of some carbamate pesticides in water samples. The studied pesticides were thiofanox, carbofuran, pirimicarb, methiocarb, carbaryl, propoxur, desmedipham and phenmedipham. Two alternative sample introduction methods have been examined and compared; SDME followed by cool on-column injection (without derivatization) and SDME followed by in-microvial derivatization and splitless injection. Acetic anhydride was used as derivatization reagent. Parameters that affect the derivatization reaction yield and the extraction efficiency of the SDME method were studied and optimized. The analytical performances and possible applications of both approaches were investigated. Relative standard deviations for the studied compounds ranged from 3.2 to 8.3%. The detection limits obtained by the derivatization method were found to be in the range 3–35 ng/L. Using cool on-column injection (without derivatization), the detection limits were between 30 and 80 ng/L.  相似文献   

17.
An at-line analysis protocol is presented that allows the determination of four UV filters, two polycyclic musk compounds and caffeine in water at concentration level of ng L−1. The fully automated method includes analytes enrichment by Microextraction by packed sorbent (MEPS) coupled directly to large volume injection-gas chromatography–mass spectrometry. Two common SPE phases, C8 and C18, were examined for their suitability to extract the target substances by MEPS. The analytes were extracted from small sample volumes of 800 μL with recoveries ranging from 46 to 114% for the C8-sorbent and 65–109% for the C18-sorbent. Limits of detection between 34 and 96 ng L−1 enable the determination of the analytes at common environmental concentration levels. Both sorbents showed linear calibration curves for most of the analytes up to a concentration level of 20 ng mL−1. Carryover was minimized by washing the sorbents 10 times with 100 μL methanol. After this thorough cleaning, the MEPS are re-used and up to 70 analyses can be performed with the same sorbent. The fully automated microextraction GC–MS protocol was evaluated for the influence of matrix substances typical for wastewater. Dilution of samples prior to MEPS is recommended when the polar caffeine is present at high concentration. Real water samples were analyzed by the MEPS-GC–MS method and compared to standard SPE.  相似文献   

18.
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1.  相似文献   

19.
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage. Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results. Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity (detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds were identified and quantified.   相似文献   

20.
Stir-bar-sorptive extraction with liquid desorption followed by large-volume injection and capillary gas chromatography coupled to mass spectrometry in selected ion monitoring acquisition mode (SBSE–LD/LVI-GC–MS(SIM)) has been developed to monitor ultra-traces of four musks (celestolide (ADBI), galaxolide (HHCB), tonalide (AHTN) and musk ketone (MK)) in environmental water matrices. Instrumental calibration (LVI-GC–MS(SIM)) and experimental conditions that could affect the SBSE-LD efficiency are discussed. Assays performed on 30-mL water samples spiked at 200 ng L?1 under optimized experimental conditions yielded recoveries ranging from 83.7?±?8.1% (MK) to 107.6?±?10.8% (HHCB). Furthermore, the experimental data were in very good agreement with predicted theoretical equilibria described by octanol–water partition coefficients (K PDMS/W?≈?K O/W). The methodology also showed excellent linear dynamic ranges for the four musks studied, with correlation coefficients higher than 0.9961, limits of detection and quantification between 12 and 19 ng L?1 and between 41 and 62 ng L?1, respectively, and suitable precision (< 20%). Application of this method for analysis of the musks in real water matrices such as tap, river, sea, and urban wastewater samples resulted in convenient selectivity, high sensitivity and accuracy using the standard addition methodology. The proposed method (SBSE–LD/LVI-GC–MS(SIM)) was shown to be feasible and sensitive, with a low-sample volume requirement, for determination of musk compounds in environmental water matrices at the ultra-trace level, overcoming several disadvantages presented by other sample-preparation techniques.  相似文献   