首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(16):2721-2731
In the present work a novel strategy for improving and/or tuning the selectivity of gas chromatographic (GC) separation by combining three different stationary phases (SPs) without premixing was introduced. A fused silica fiber coated with polydimethylsiloxane (SE30) and another coated with cyanopropylphenylmethylpolysiloxane (OV1701) were serially inserted into an 8-m polyethylene glycol 20 M (PEG20M) capillary column to form a GC annular column with ternary SP, abbreviating as SE30-OV1701-CF/PEG20M-CC. The separation capability of this ternary SP annular column was compared with a SE30-coated fiber-in-PEG20M-coated capillary annular column and a PEG20M-coated open tubular column by a test mixture of 19 organic compounds. Among these three columns, SE30-OV1701-CF/PEG20M-CC produced the best separation when the SE30-coated fiber and OV1701-coated fiber was 3 and 5 m, respectively. Selectivity can be easily tuned by changing the length of the SP-coated fibers in the ternary SP annular column. The proposed ternary SP annular column shows additional tunability, thus making it a promising tool for separation of organic solvents that are often used in the manufacturing process of pharmaceutical formulations and lacquer thinners.  相似文献   

2.
The influence of a water vapor admixture in helium, nitrogen, and carbon dioxide on capacity coefficients of C3−C5 alcohols and pyridine during chromatography process in capillary columns with polar (PEG-20M) and nonpolar (SE-30) stationary phases was studied. The introduction of a water admixture into the carrier gas, increases the capacity coefficient of polar organic compounds on the capillary column with PEG-20M and has almost no effect on this value in the case of SE-30. The change in retention of polar organic compounds on the capillary column with the PEG-20M polar phase occurs due to a change in the properties of the stationary phase when it adsorbs water from the mobile phase. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 11, pp. 2258–2261, November, 1998.  相似文献   

3.
The gas chromatographic behavior of di-n-alkylketones and isomeric methylcyclohexanones at variable temperatures in the isothermal runs has been studied using three capillary columns coated with SE-30, OV-225, and PEG-40M/KF stationary phases. The retention indices and their temperature increments were determined, and the partial molar free energies of the compounds under study were calculated. A linear dependence of the values of the partial molar free energy of sorption on the homologue number in di-n-alkylketones is not observed for the first member on the nonpolar SE-30 phase and for the third member on the polar OV-225 and PEG-40M/KF phases. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 2, pp. 328–332, February, 1997.  相似文献   

4.
Zhang G  Li Y  Fang Y  Han N  Xu B 《Electrophoresis》2003,24(4):693-699
Octadecyl silyl silica (ODS) phase coated with immobilized polysiloxanes (OV1701, SE-54, SE-30) were synthesized, their characteristics as capillary electrochromatography (CEC) column packing materials were studied. It was found that, although the polysiloxane coatings were different in polarity, the resulting packing materials showed the highest efficiencies when the respective coating ratios (polysiloxane:ODS, w/w) were all 20-30%. As expected, packing materials coated with different polysiloxanes resulted in different selectivity on solute pairs. Separations on these stationary phases were studied with different factors such as pH values and acetonitrile contents of the mobile phases. It was found that all these kind of stationary phases could resist basic mobile phase with a pH value as high as 11.6. Tests were made to analyze polar, basic drugs with CEC using the stationary phases.  相似文献   

5.
Complex organic mixtures, such as coal liquefaction and oil shale products and by-products, are comprised of hundreds or thousands of individual components. State-of-the-art high resolution gas chromatography does not always provide sufficient resolution to allow accurate quantitation or identification of many compounds of interest. The concept of dual capillary column chromatography combines the different resolving characteristics of two capillary columns coated with different stationary phases into a single chromatographic run. In this approach, both columns are connected to the same injection port. Analysis of complex mixtures in this fashion can confirm the identification and quantitation of components on two columns of different polarity with little increased analysis time, can provide a means of obtaining quantitative data for individual components which are known to coelute on any one column, and can alert one to unknown coelution problems that would be undetected by gas chromatographic analysis on a single capillary column. Simultaneous dual column analysis was applied to three samples, the neutral polycyclic aromatic hydrocarbon (PAH) fraction of a Solvent Refined Coal-II (SRC-II) heavy distillate, the nitrogen-containing polycyclic aromatic compound (N-PAC) fraction of an SRC-II heavy distillate, and the basic fraction from a shale oil process water. Fused silica capillary columns coated with SE-54 and Durawax 3 were used for the analyses of the heavy distillate, while SE-54 an Carbowax 20M capillary columns were used for the analysis of the process water.  相似文献   

6.
R. Novina 《Chromatographia》1982,15(11):704-706
Summary A method has been developed using gas chromatography — electron impact mass spectrometry for the determination of the di-0-isopropylidene-sorbofuranose and mono-0-isopropylidene-sorbofuranose. The compounds are separated as their trimethylsilyl derivatives on a capillary column coated with the stationary phase SE-52. The mass spectra show that the silylation reaction is quantitiative and that the isopropylidene groups does not change.  相似文献   

7.
A sol-gel chemistry-based polymer coating approach was developed for the preparation of a novel polysiloxane-coated silica stationary phase for capillary liquid chromatography. SE-30, a commercial polysiloxane stationary phase used in gas chromatography, was incorporated into the properly designed sol solution. Then the sol-gel mixture was introduced into a silica gel-packed capillary column by pressure. A thin film of sol-gel SE-30-coating is chemically bonded to the surface of silica gel particles by hydrolytic polycondensation under mild conditions without any free radical cross-linking procedures, therefore the sol-gel approach offers a simple and effective pathway to create a hybrid polymer-coated silica stationary phase. Various factors affecting column making were optimized and discussed in this report. The resulting stationary phase showed good permeability, mechanical robustness, high durability to alkaline mobile phase and satisfactory chromatographic performance in separations of polar and non-polar aromatic compounds. Linear solvation energy relationships (LSERs) studies indicate that the stationary phase has a reversed-phased character with SE-30 providing chromatographic functionality. The solute size and the solute hydrogen bond ability are major factors that principally govern the retention of test solutes.  相似文献   

8.
Summary A new resorcarene derivatives, ethylhexylresorcarene, was synthesized and used as stationary phase in opentubular (capillary) columns. It was combined with heptakis(2,6-di-O-pentyl-3-O-trifluoroacetyl)-β-CD and coated on fused-silica capillary tubes. By studying the chromatographic properties of the mixed stationary phase and its selectivity for different isomers, as well as comparing with the resorcarene and the CD used as individual stationary phases, a synergistic effect was observed on the mixed stationary phase.  相似文献   

9.
S. Boneva  M. Skumov 《Chromatographia》1999,49(7-8):415-418
Summary The separation of some tricyclic spiro esters on fused-silica capillary columns coated with dimethylsiloxane, cyanopropyl methyl siloxane and poly(ethylene glycol) stationary phases was investigated. Retention indices were determined at two temperatures to interpret their chromatographic behaviour. The repeatability of the measurements was 0.2, 0.3 and 0.5 index units. The influence of the polarity of the stationary phases on the chromatographic retention of these tricyclic spiro esters is discussed.  相似文献   

10.
A general method for the trace analysis of benzodiazepine drugs and their major metabolites at single dose therapeutic levels in 0.2 ml blood samples is described. The method involves solvent extraction of blood with toluene, isolation of the analytes using deactivated Amberlite XAD-7 porous polymer beads, and analysis of the cleaned-up extracts by capillary column gas chromatography with electron-capture detection. The clean-up technique eliminates lipids and other interfering material, enabling routine analysis of blood extracts to be carried out with no significant deterioration in column or detector performance over a period of many months. The use of fused-silica capillary columns coated with SE-52 and the correct choice of chromatographic conditions permits underivatised benzodiazepines of widely differing volatilities and polarites to be analysed. Data for 26 benzodiazepines and metabolites are presented.  相似文献   

11.
The graphene oxide (GO) is carbon based material that has high surface area, high adsorption ability, and is stable at high temperature. In this work, the GO phase was prepared and used for gas chromatographic separation. GO nanosheets were covalently bonded onto the inner surface of fused silica capillary column using 3-aminopropyldiethoxymethyl silane as cross-linking agent. The prepared GO nanosheets were characterized with TEM and the GO coating was characterized with SEM. As a high performance stationary phase, GO provides not only a high surface area to increase the phase ratio but also rich functional groups for the formation of hydrophobicity, hydrogen bonding, and π–π electrostatic stacking interactions with volatile aromatic or unsaturated organic compounds. Thus, mixtures of a wide range of organic compounds including alcohols and aromatic compounds were well separated and an efficiency of 1990 theoretical plates per meter for anisole was obtained on GO coated 1.0 m × 200 μm i.d. fused silica capillary column. The experimental results demonstrate that GO coated capillary columns are promising for gas chromatographic separation.  相似文献   

12.
Derivatization of chlorophenols prior to gas chromatographic analysis resulted in a significant improvement of their chromatographic behaviour. Chlorophenols in the form of anisoles, acetates, and pentafluorobenzyl ethers were separated either on a HP-1 wide-bore capillary column or on a capillary column coated with a film of SE-54. Due to an enhancement of the poor electron-capture detection response of mono- and dichlorophenols, pentafluorobenzylation made it possible to determine trace amounts in spiked water. Moreover, simultaneous analysis of phenoxyalkanoic acids was accomplished under the same conditions.  相似文献   

13.
套索冠醚固定相的性能和分离机理研究   总被引:1,自引:0,他引:1  
用3种新合成的套索冠和为固定相,制成石英毛细管柱,测其柱效、惰性、热稳定性、平均极性及选择等性质,实验表明,它们具有良好的色谱性能和分离选择性,适用于对醇、卤代烃、芳香烃等及其异构体的分离。  相似文献   

14.
The octadecylamine-capped gold nanoparticles (ODA-Au-NPs) were prepared and directly used to coat the capillary wall. The hydrophobic coating acted as the stationary phase for open-tubular gas chromatography (OTGC). The ODA-Au-NPs can be adsorbed tightly onto the inner surface of fused silica capillary column via electrostatic interaction and enhanced interaction of van der Waals between gold nanoparticles and the capillary wall. Thus, the modification of the inner surface of capillary column by ODA-Au-NPs can be achieved simply by flushing the capillary with a solution of ODA-Au-NPs and the resulted ODA-Au-NPs coating is very stable. No perceptible degradation in the ODA-Au-NPs-based separation was observed after ∼1900 sample runs. This type of columns also provided excellent chromatographic performances: high number of theoretical plates, outstanding run-to-run and column-to-column reproducibility, and high selectivity for a wide range of test mixtures. An efficiency of 2474 theoretical plates per meter for chlorobenzene was obtained on an ODA-Au-NPs-modified 1.6 m × 100 μm i.d. fused silica capillary column.  相似文献   

15.
Summary Methylbenzenes, pyridines and pyrazines were investigated on fused-silica and glass capillary columns coated with SE-30 and PEG-40M/KF liquid phases, at two temperatures, 80° and 110°C. The contribution of the methylene groups to the partial molar free sorption energy was determined for methylpyridines and pyrazines. Equations are proposed for the calculation of the retention indices of methyl pyridines and pyrazines. These equations are based on the ortho- and α-effects of the methyl groups. The predicted indices have been experimentally tested for six dimethyl- and trimethylpyridines, and four methylpyrazines. Good accuracy of the calculation permits to use this method for the identification of methylpyridines and pyrazines in complex mixtures. Enlarged text of the paper presented at the Eighth International Symposium on Capillary Chromatography, Riva del Garda, Italy, May 19–21, 1987.  相似文献   

16.
Cyclodextrins with heterocyclic substitution as GC stationary phases   总被引:2,自引:0,他引:2  
Summary Two new cyclodextrin (CD) derivatives, heptakis{2,6-di-O-pentyl-3-O-[3′-(2″-chloro-4″,5″-dioxylmethene)-phenyl-5′-iso-oxazolylmethyl]}-β-CD (CD I) and heptakis{2,6-di-O-methyl-3-O-[3′-(2″-chloro)-phenyl-5′-iso-oxazolylmethyl]}-β-CD (CD II) were synthesized and coated on fused-silica capillary columns. Their chromatographic characteristics, including column efficiency, polarity, selectivity and phase transition were studied and compared with similar β-CD stationary phases. It was found that the heterocycle group has a significant effect on the selectivity of the CD stationary phases. Both stationary phases can be successfully used to separate many di- and trisubstituted benzene positional isomers and show stronger separation ability in separating low-polarity benzene positional isomers than other β-CD stationary phases.  相似文献   

17.
A wide-bore capillary gas chromatographic method has been developed to study the drug matrix effect on the determination of residual solvents in bulk pharmaceuticals. A selective method is achieved on a Restek wide-bore (0.53-mm i.d. x 30 m) open-tubular fused-silica column coated with a 5-micron film of 95% dimethyl-5% diphenyl polysiloxane protected by a phenyl-methyl siloxane deactivated, uncoated fused-silica guard column. Utilizing this method, several common process solvents in weakly acidic, weakly basic, and neutral drug matrices are evaluated by recovery and linearity studies to show whether or not a drug matrix effect exists in their determination.  相似文献   

18.
Li Y  Xiang R  Horváth C  Wilkins JA 《Electrophoresis》2004,25(4-5):545-553
A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

19.
A new simplified method was developed for the preparation of immobilized stationary phase fused silica capillary columns coated with OV-1-vinyl, SE-54, and OV-1701-vinyl. This methodology includes the application of the moderately polar stationary phase OV-1701-vinyl as a surface deactivation agent that may also participate in the dicumyl peroxide initiated free radical immobilization process. Practical details of the procedure are presented and applications of the laboratory-produced columns are illustrated with capillary gas chromatographic separations of standard mixtures. Possible contributions of the OV-1701-vinyl deactivation layer to both crosslinking and surface bonding in the immobilization process are discussed.  相似文献   

20.
A fused-silica capillary gas chromatographic method is described for the determination of dye intermediates in oxidative hair dyes. An appropriate amount of hair dye sample is dissolved in 10 ml of methanol containing 0.25 g of ammonium thioglycolate and an appropriate amount of 2-amino-4-methylphenol as an internal standard. This solution is directly injected into a gas chromatograph. A fused-silica capillary column with cross-linked methyl silicone OV-1 or SE-54 as a liquid phase yields excellent resolution of dye intermediates. Some factors affecting the quantitation of dye intermediates are discussed. The proposed method gave good recoveries and reproducibilities, and permits simultaneous determination of various types of dye intermediates without any pretreatment. The use of a nitrogen-phosphorus detector allows the selective detection of nitrogen-containing dye intermediates. This simple and versatile method is applicable for the determination of dye intermediates in commercial hair dyes.  相似文献   