首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The study of pesticide residues belonging to endocrine disrupting chemicals (EDCs) (23 analytes of different chemical classes – organochlorines, organophosphates, pyrethroids, dicarboximides, phtalamides, dinitroanilines, pyrazole, triazinone) in apple matrix with conventional capillary GC–NCI-MS (with methane as reagent gas) in comparison to EI ionization is presented. For sample preparation QuEChERS method was applied. The lowest calibration levels (LCLs) for all pesticides were determined in both modes. Calibration in the NCI mode was performed at the concentration levels from 0.1 to 500 μg kg−1 (R2 > 0.999) and for EI in the range from 5 to 500 μg kg−1 (R2 > 0.99). From LCLs the instrumental limits of detection (LODs) and quantification (LOQs) were calculated. Chemometric study of pesticide signals in two MS modes was performed. Repeatability of all measurements, expressed by the relative standard deviations of absolute peak areas was better than 10% for the majority of compounds. Significantly lower values were obtained for the NCI mode.  相似文献   

2.
A reliable, sensitive and eco-friendly injection-port trimethylsilylated (TMS) derivatization and gas chromatography–tandem mass spectrometry (GC–MS/MS) with furan chemical ionization (furan-CI) method was developed to determine melamine and cyanuric acid in powdered milk samples. The effects of several parameters related to the TMS-derivatization process (i.e., injection-port temperature, residence time and volume of silylating agent) and of various CI agents were investigated. Addition of a solution (3 μL) of bis(trimethyl)silyltrifluoroacetamide (BSTFA) containing 1% trimethylchlorosilane (TMCS) reagent to a 20-μL extract from the powdered milk sample gave an excellent yield of the tris-TMS-derivatives of melamine and cyanuric acid at an injection-port temperature of 90 °C. Furthermore, using furan as the CI agent in conjunction with tandem mass spectrometry provided the greatest sensitivity and selectivity of detection. The limits of quantitation (LOQs) for melamine and cyanuric acid were 0.5 and 1.0 ng/g in 0.5-g of powdered milk samples, respectively. The recoveries from spiked samples – after simple ultra-sonication with 5% dimethyl sulfoxide in acetonitrile coupled with n-hexane liquid–liquid extraction – ranged from 72% to 93% with relative standard deviations of lower than or equal to 18%. In three of four real powdered milk samples, melamine was detected at concentrations ranging from 36 to 1460 ng/g; and cyanuric acid was detected in two of these samples at concentrations of 17 and 180 ng/g.  相似文献   

3.
Methamphetamine and amphetamine were extracted from human whole blood samples using pipette tip solid-phase extraction (SPE) with MonoTip C18 tips, on which C18-bonded monolithic silica gel was fixed. Human whole blood (0.1 mL) containing methamphetamine and amphetamine, with N-methylbenzylamine as an internal standard, was mixed with 0.4 mL of distilled water and 50 μL of 5 M sodium hydroxide solution. After centrifugation, the supernatant was extracted to the C18 phase of the tip (pipette tip volume, 200 μL) by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C18 phase were eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography – mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine and amphetamine spiked into whole blood were more than 87.6 and 81.7%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.5–100 ng/0.1 mL. The limits of detection for methamphetamine and amphetamine were 0.15 and 0.11 ng/0.1 mL, respectively. Intra- and interday coefficients of variation for both stimulants were not greater than 9.6 and 13.8%, respectively. The determination of methamphetamine and amphetamine in autopsy whole blood samples is presented, and was shown to validate the present methodology.  相似文献   

4.
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography–mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500 μg L−1 could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12 μg L−1 for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237 μg L−1 (3,5-DCP) to 0.3623 μg L−1 (2,3,6-TCP).  相似文献   

5.
An efficient microwave-assisted extraction (MAE) procedure coupled to gas chromatography–mass spectrometry (GC–MS) with electron impact (EI) and chemical ionization (CI) has been developed to determine five organophosphate flame retardants (OPFRs) in marine and river sediments. The effects of various operating parameters on the quantitative extraction of the OPFRs through MAE were systematically investigated. Selected OPFRs were extracted from the sediments through MAE using 40 mL of acetone at 120 °C for 20 min. The limits of quantitation ranged from 0.1 to 0.4 ng/g (dry weight) in 2 g of the sediment samples. Moreover, as the chlorinated alkyl phosphates present no molecular ions in EI, GC–MS with furan-CI (furan-CI) was applied to confirm their determination in complex environmental samples. The recoveries of the selected OPFRs in spiked sediment samples ranged from 62% to 106% (relative standard derivation, 1−11%). The total concentrations of the selected OPFR residues in marine and river sediments ranged from 1.0 to 12.6 ng/g.  相似文献   

6.
The study describes the determination of mono-hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs), metabolites of PAHs, in human hair. Twelve selected OH-PAHs from two to four rings, generally determined in urine analysis, were investigated as markers of human exposure to PAHs. Following hydrolysis of hair specimens of 50–300 mg with 1 M NaOH, OH-PAHs were extracted using dichloromethane and submitted to an optimized derivatization with (2S,4R)-N-heptafluorobutyryl-4-heptafluorobutoyloxy-prolyl chloride. Compounds were then analyzed using gas chromatography–negative chemical ionization mass spectrometry (GC–NCIMS). The average inter-day and intra-day variability was 12% and 17%, respectively. The average recovery was 52% and the limits of detection and quantification ranged from 20 and 66 pmol/g for 1-OH-phenanthrene (i.e., 3.9 and 12.8 pg/mg) to 311 and 1030 pmol/g for 2-OH-benzo(c)phenanthrene (i.e., 75.9 and 251 pg/mg). The influence of hair washing with water as decontamination step, and enzymatic treatment (β-glucuronidase) to hydrolyze conjugated derivatives were also tested. The application of the developed method to the analysis of 30 hair specimens (17 from non-smoker and 13 from smoker volunteers) demonstrated inter-individual qualitative and quantitative variations. According to the easiness of hair sampling and based on the extended detection windows provided by hair analysis, this method is proposed as a new promising tool for the assessment of human chronic exposure to PAHs.  相似文献   

7.
The present study describes a new environmentally friendly sample pretreatment system based on solid-phase microextraction (SPME) for the sensitive determination of polyphenols. A derivatization process was necessary to convert the polar non-volatile compounds into volatile derivatives. Direct immersion (DI) SPME was used for the adsorption of polyphenols, and then the fiber was placed in the headspace of the derivatizing reagent, bis(trimethylsilyl)trifluoroacetamide (BSTFA). The separation was carried out by coupling gas chromatography with mass spectrometry in the selected ion monitoring mode, after silylation. Optimal extraction conditions were 25 °C for 10 min under continuous stirring using DI and a polyacrylate fiber. After extraction, the fiber was inserted into the headspace of BSTFA (10 μL) and the polyphenols were derivatized for 15 min at 50 °C. Desorption was carried out at 280 °C for 5 min. The method allowed the determination of both isomers cis- and trans-resveratrol, piceatannol, catechin and epicatechin in wine and grapes, and it was validated for linearity, detection and quantitation limits, selectivity, accuracy and precision. Detection limits ranged from 0.05 to 0.9 ng mL−1 at a signal-to-noise ratio of 3, depending on the compound. Recoveries obtained for spiked samples were satisfactory for all compounds.  相似文献   

8.
A novel analytical system for gas-chromatographic investigation of complex samples has been developed, that combines the advantages of several analytical principles to enhance the analytical information. Decomposition of high molecular weight structures is achieved by pyrolysis and a high separation capacity due to the chromatographic step provides both an universal as well as a selective and sensitive substance detection. The latter is achieved by simultaneously applying electron ionization quadrupole mass spectrometry (EI-QMS) for structural elucidation and [1 + 1]-resonance-enhanced-multi-photon ionization (REMPI) combined with time-of-flight mass spectrometry (ToFMS). The system has been evaluated and tested with polycyclic aromatic hydrocarbon (PAH) standards. It was applied to crude oil samples for the first time. In such highly complex samples several thousands of compounds are present and the identification especially of low concentrated chemical species such as PAH or their polycyclic aromatic sulfur containing heterocyclic (PASH) derivatives is often difficult. Detection of unalkylated and alkylated PAH together with PASH is considerably enhanced by REMPI–ToFMS, at times revealing aromatic structures which are not observable by EI-QMS due to their low abundance. On the other hand, the databased structure proposals of the EI-QMS analysis are needed to confirm structural information and isomers distinction. The technique allows a complex structure analysis as well as selective assessment of aromatic substances in one measurement. Information about the content of sulfur containing compounds plays a significant role for the increase of efficiency in the processing of petroleum.  相似文献   

9.
The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have been evaluated using pyrolysis–gas chromatography–mass spectrometry (Py–GC–MS) and gas chromatography–mass spectrometry (GC–MS). The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC–MS. Two types of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally, the studied biocides—Biotin, New-Des and Nipagine—generally exhibited good inhibiting effects on the microorganisms studied, although some interesting differences were found between them regarding the application method and type of biocide.  相似文献   

10.
Methods for trace determination of sulphur mustard (HD) and some related cyclic sulphur compounds in soil samples have been developed using headspace-trap in combination with gas chromatography–mass spectrometry (GC–MS). Two quite different types of soil were employed in the method optimisation (sandy loam and silty clay loam). Prior to analysis, water saturated with sodium chloride was added to the samples, at a water to soil ratio of 1:1. A detection limit of 3 ng/g was achieved for HD, while the cyclic sulphur compounds 1,4-thioxane, 1,3-dithiolane and 1,4-dithiane could be detected at 0.2–0.7 ng/g. The methods were validated in the concentration range from the limit of quantification (LOQ) to hundred times LOQ. The within assay precision at fifty times LOQ was 6.9–7.3% relative standard deviation (RSD) for determination of the cyclic sulphur compounds, and 15% RSD for determination of HD. Recoveries were in the range of 43–60% from the two soil types. As the technique requires very little sample preparation, the total time for sample handling and analysis was less than 1 h. The technique was successfully employed for the determination of cyclic sulphur compounds in a sediment sample from an old dumping site for chemical munitions, known to contain HD degradation products.  相似文献   

11.
Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL−1, and demonstrated good linearity of R2 from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL−1. Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified.  相似文献   

12.
In this study, a simple and efficient large volume injection gas chromatography–mass spectrometry (GC-MS) method, via a programmable-temperature vaporizer (PTV) inlet, has been developed and applied in the determination of estrogens in environmental water samples without a prior derivatization process. Three commonly used estrogens estrone, 17 β-estradiol and 17 α-ethynylestradiol were selected as target compounds for this study. It has been demonstrated that the type of gas chromatograph liner and the initial inlet temperature can greatly affect the response intensity of estrogens. Three different types of PTV liners have been studied; the multibaffle liner generated the strongest response intensities towards the estrogen analytes. The results showed that the response intensities of estrogens reduced sharply while the initial inlet temperature increased. Various instrument conditions and sample preparation methods were studied in detail. The optimized method has been validated with good linearity, precision and accuracy. The method detection limit of each estrogen was found to be 0.041 ng/L for estrone, 0.046 ng/L for 17 β-estradiol and 0.031 ng/L for 17 α-ethynylestradiol. To the best of our knowledge, these results represent the best sensitivities achieved for estrogens analyzed in water samples via traditional GC-MS method without a derivatization process. This method has been successfully applied in the analyses of different water samples.  相似文献   

13.
A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography–mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R 2=0.9932–1.0000), dynamic range (3 orders of magnitude), precision (4–9% RSD), as well as LOD (0.001–0.124 μg L−1) and LOQ (0.004–0.413 μg L−1), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 μg L−1 in river water and 3.76, 13.25, and 0.10 μg L−1 in fish serum, respectively. Natural steroid hormones estrone (E1), 17β-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 μg L−1 in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 μg L−1, respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.  相似文献   

14.
Ribonucleosides are the end products of RNA metabolism. These metabolites, especially the modified ribonucleosides, have been extensively evaluated as cancer-related biomarkers. However, the determination of urinary ribonucleosides is still a challenge due to their low abundance, high polarity and serious matrix interferences in urine samples. In this study, a derivatization method based on a chemical reaction between ribonucleosides and acetone to form acetonides was developed for the determination of urinary ribonucleosides. The derivative products, acetonides, were detected by using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The methodological evaluation was performed by quantifying four nucleosides for linear range, average recovery, precision, accuracy and stability. The validated procedures were applied to screen modified ribonucleosides in urine samples. Improvement of separation and enhancement of sensitivity were obtained in the analysis. To identify ribonucleosides, inexpensive isotope labeling acetone (acetone-d6) and label-free acetone were applied to form ordinary and deuterated acetonides, respectively. The two groups of samples were separated with orthogonal partial least squares (OPLS). The ordinary and deuterated pairs of acetonides were symmetrically distributed in the S-plot for easy and visual signal identification. After structural confirmation, a total of 56 ribonucleosides were detected, 52 of which were modified ribonucleosides. The application of derivatization, deuterium-labeling and multivariate statistical analysis offers a new option for selective detection of ribonucleosides in biological samples.  相似文献   

15.
A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography–mass spectrometry detection (GC–MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol–gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature, extraction time, and desorption conditions were investigated and optimized. The developed method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. Under the optimized conditions, the detection limit of the method was 5 ng L−1 using selected ion monitoring (SIM) mode. The inter-day and intra-day precisions of the developed method under optimized conditions were below 10%, and the method shows linearity in the range of 20 ng L−1 to 500 μg L−1with the correlation coefficient of >0.99. The optimized method was applied to the sampling of phenol from some biologics production areas. The compared results obtained using current and standard methods were shown to be satisfactory.  相似文献   

16.
Reproducible and quantitative gas chromatography–mass spectrometry (GC-MS)-based metabolomics analysis of complex biological mixtures requires robust and broad-spectrum derivatization. We have evaluated derivatization of complex metabolite mixtures using trimethylsilyl cyanide (TMSCN) and the most commonly used silylation reagent N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). For the comparative analysis, two metabolite mixtures, a standard complex mixture of 35 metabolites covering a range of amino acids, carbohydrates, small organic acids, phenolic acids, flavonoids and triterpenoids, and a phenolic extract of blueberry fruits were used. Four different derivatization methods, (1) direct silylation using TMSCN, (2) methoximation followed by TMSCN (M-TMSCN), (3) direct silylation using MSTFA, and (4) methoximation followed by MSTFA (M-MSTFA) were compared in terms of method sensitivity, repeatability, and derivatization reaction time. The derivatization methods were observed at 13 different derivatization times, 5 min to 60 h, for both metabolite mixtures. Fully automated sample derivatization and injection enabled excellent repeatability and precise method comparisons. At the optimal silylation times, peak intensities of 34 out of 35 metabolites of the standard mixture were up to five times higher using M-TMSCN compared with M-MSTFA. For direct silylation of the complex standard mixture, the TMSCN method was up to 54 times more sensitive than MSTFA. Similarly, all the metabolites detected from the blueberry extract showed up to 8.8 times higher intensities when derivatized using TMSCN than with MSTFA. Moreover, TMSCN-based silylation showed fewer artifact peaks, robust profiles, and higher reaction speed as compared with MSTFA. A method repeatability test revealed the following robustness of the four methods: TMSCN?>?M-TMSCN?>?M-MSTFA?>?MSTFA.
Figure
Improved GC-MS profiling of Complex Biological Mixtures by TMSCN based Derivatization  相似文献   

17.
A novel method based on the coupling of membrane-supported headspace single-drop microextraction with gas chromatography?mass spectrometry (GC–MS) is developed for the determination of chlorobenzenes in water samples. For the determination of five chlorobenzenes, a 15 μL toluene microdrop was placed inside the plastic membrane and exposed for 10 min for headspace extraction while stirring at 1000 rpm. The microdrop was then picked up by a microsyringe and directly injected into the injector block of the GC–MS instrument. Under the optimized operation conditions, the calculated calibration curves gave a high level of linearity for all targets with correlation coefficients range from 0.9945 to 0.9987. The limits of detection range from 0.01 to 0.05 μg/L and the RSDs for most of chlorobenzenes were below 7%. The method is simple, sensitive, and stable for single drop microextraction. Its applicability is demonstrated by the determination of chlorobenzenes in tap water samples.  相似文献   

18.
A new approach using single-drop microextraction (SDME) and gas chromatography–mass spectrometry for the determination of six haloacetic acids (HAAs) in water samples was presented. n-Octanol was used as extractant and derivatization reagent. HAAs were derivatized both simultaneously during the extraction in the solvent microdrop, and after extraction, inside a glass microvial (1.1 mm I.D.). Trifluoroacetic anhydride (TFAA) was used as the reaction catalyst. The influence of catalyst amount, derivatization time and temperature on the yield of the in-microvial derivatization was investigated. Derivatization reaction was performed using 1.2 μL of TFAA at 100 °C for 20 min. Extraction was performed using 1.8 μL of n-octanol containing TFAA (10%, v/v). Experimental parameters, such as, exposure time, sample pH and extraction temperature were controlled and optimized. Analytical parameters such as linearity, precision and limit of detection were also evaluated. The proposed method was proved to be a suitable analytical procedure for HAAs in water with limits of detection 0.1–1.2 μg/L. The relative recoveries range from 82.5 to 97.6% for all the target analytes. Precision values were from 5.1 to 8.5% (as intra-day relative standard deviation, RSD) and 8.8–12.3% (as inter-day RSD).  相似文献   

19.
Dimethyl disulphide (DMDS) is a volatile sulphur compound and is used as a new type of soil fumigant. The objective of this study was to develop an effective method to extract and analyse DMDS residue in soil, then determine the degradation kinetics of DMDS in soil using the above method. The results showed that DMDS extraction from soil by ethyl acetate under static conditions for 60 min gave the best recovery. The extracted DMDS was analysed by gas chromatography–mass spectrometry (GC-MS), and the limit of quantification of DMDS in the soil was 5 μg/kg. The average recoveries of the DMDS at five different concentrations were in the range of 65.4–120.1% with all intra- and inter-day relative standard deviation less than 19.1 and 14.8, respectively. The degradation rates of DMDS in different soils were significantly different and were strongly influenced by the soil pH. The results in the present study will be useful for DMDS environmental behaviour study in future.  相似文献   

20.
A gas chromatography–mass spectrometric (GC–MS) method has been established for the determination of hydrazine in drinking water and surface water. This method is based on the derivatization of hydrazine with ortho-phthalaldehyde (OPA) in water. The following optimum reaction conditions were established: reagent dosage, 40 mg mL−1 of OPA; pH 2; reaction for 20 min at 70 °C. The organic derivative was extracted with methylene chloride and then measured by GC–MS. Under the established condition, the detection and the quantification limits were 0.002 μg L−1 and 0.007 μg L−1 by using 5.0-mL of surface water or drinking water, respectively. The calibration curve showed good linearity with r2 = 0.9991 (for working range of 0.05–100 μg L−1) and the accuracy was in a range of 95–106%, and the precision of the assay was less than 13% in water. Hydrazine was detected in a concentration range of 0.05–0.14 μg L−1 in 2 samples of 10 raw drinking water samples and in a concentration range of 0.09–0.55 μg L−1 in 4 samples of 10 treated drinking water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏