共查询到20条相似文献,搜索用时 15 毫秒
1.
Shu-Chao Wu Chao-Yang Sun Wen-Ni Wang Ying-Ting He Sheng-Hong Hu Cun-Jiang Zheng 《中国化学快报》2013,24(7):633-635
In this paper,separation of Sr from associated elements(Na,K,Ca,Mg,and Ba) was carried out using an extraction chromatographic column packed with Sr selective specific resin consisting of an octanol solution of 4,4’(5’)-bis(t-butylcyclohexo)-18-crown-6 sorbed on an inert polymeric support.Using 8.0 mol/L HNO3 as the eluent,Ba and associated elements were eluted immediately from the column, whereas Sr was strongly retained.The adsorbed Sr could then be stripped from the column as the eluent was changed to 0.05 mol/L HNO3.Complete Sr/Ba separation was demonstrated to be feasible in that Ba could be washed from the column leaving pure Sr by adequate rinsing with 8.0 mol/L HNO3. Furthermore,matrix effect could be effectively eliminated and the selectivity of the method was improved.The method was applied for the determination of Sr in the high purity barium carbonate (BaCO3) product and seawater.The recoveries of Sr in 2 samples were determined to be 93.2%and 109%, respectively. 相似文献
2.
An improved extraction chromatographic resin for the separation of uranium from acidic nitrate media 总被引:1,自引:0,他引:1
The preparation and characterization of a new extraction chromatographic resin exhibiting extraordinarily strong retention of hexavalent uranyl ion over a wide range of nitric acid concentrations and very high selectivity for U(VI) over Fe(III) and numerous other cations is described. This new material (designated U/TEVA-2) comprises a novel liquid stationary phase consisting of an equimolar mixture of diamyl amylphosphonate (DA[AP]) and Cyanex 923® (a commercially available trialkyl-phosphine oxide, TRPO) sorbed on silanized silica or Amberchrom CG-71. Cyanex 923 is shown to be preferable to a related TRPO, Cyanex 925®, due to its lower viscosity and higher selectivity for U(VI) over Fe(III). The retention of uranyl nitrate by the U/TEVA-2 resin, as measured by the k′ values (number of free column values to peak maximum) is >5000 from approximately 0.1 to 8 M HNO3. The ability of the new resin to strongly and selectively retain U(VI) from such a wide range of acid concentrations, along with its favorable physical properties, make it a good candidate for application in the separation and preconcentration of U(VI) from complex environmental, biological, and nuclear waste samples for subsequent determination. 相似文献
3.
The paper describes a research of possible application of UTEVA and TRU resins and anion exchanger AMBERLITE CG-400 in nitrate form for the isolation of uranium and thorium from natural samples. The results of determination of distribution coefficient have shown that uranium and thorium bind on TRU and UTEVA resins from the solutions of nitric and hydrochloric acids, and binding strength increases proportionally to increase the concentration of acids. Uranium and thorium bind rather strongly to TRU resin from the nitric acid in concentration ranging from 0.5 to 5 mol L−1, while large quantities of other ions present in the sample do not influence on the binding strength. Due to the difference in binding strength in HCl and HNO3 respectively, uranium and thorium can be easily separated from each other on the columns filled with TRU resin. Furthermore, thorium binds to anion exchanger in nitrate form from alcohol solutions of nitric acid very strongly, while uranium does not, so they can be easily separated. Based on these results, we have created the procedures of preconcentration and separation of uranium and thorium from the soil, drinking water and seawater samples by using TRU and UTEVA resins and strong base anion exchangers in nitrate form. In one of the procedures, uranium and thorium bind directly from the samples of drinking water and seawater on the column filled with TRU resin from 0.5 mol L−1 HNO3 in a water sample. After binding, thorium is separated from uranium with 0.5 mol L−1 HCl, and uranium is eluted with deionised water. By applying the described procedure, it is possible to achieve the concentration factor of over 1000 for the column filled with 1 g of resin and splashed with 2 L of the sample. Spectrophotometric determination with Arsenazo III, with this concentration factor results in detection limits below 1 μg L−1 for uranium and thorium. In the second procedure, uranium and thorium are isolated from the soil samples with TRU resin, while they are separated from each other on the column filled with anion exchanger in alcohol solutions. Anion exchanger combined with alcohol solutions enables isolation of thorium from soil samples and its separation from a wide range of elements, as well as spectrophotometric determination, ICP-MS determination, and other determination techniques. 相似文献
4.
Summary The profile of serum bile acids is a result of their liver metabolism and enterohepatic circulation.In the present work size exclusion chromatography is used for extraction of serum bile acids to optimize the methodology for analyzing serum bile acids by high resolution gas chromatography.Compared to other extraction methods like adsorption-[1–3] or reversed phase chromatography [4,5], this novel technique yielded a satisfactory recovery (75–104%) with high reproducibility. Therefore a reliable determination of serum bile acids is possible. 相似文献
5.
Kostanian AE Berthod A Ignatova SN Maryutina TA Spivakov BY Sutherland IA 《Journal of chromatography. A》2004,1040(1):63-72
In countercurrent chromatography (CCC) both stationary and mobile liquids undergo intense mixing in the variable force field of a coil planet centrifuge and the separation process, like the separation in conventional solvent extraction column, is influenced by longitudinal mixing in the phases and mass transfer between them. This paper describes how the residence time distribution (or the elution profile) of a solute in CCC devices and the interpretation of experimental peaks, can be described by a recently developed cell model of longitudinal mixing. The model considers a CCC column as a cascade of perfectly mixed equal-size cells, the number of which is determined by the rates of longitudinal mixing in the stationary and mobile phases. Experiments were carried out to demonstrate the validation of the model and the possibility of predicting the partitioning behaviour of the solutes. The methods for estimating model parameters are discussed. Longitudinal mixing rates in stationary and mobile phases have been experimentally determined and experimental elution profiles are compared with simulated peaks. It is shown that using the cell model the peak shape for a solute with a given distribution constant can be predicted from experimental data on other solutes. 相似文献
6.
Zornitza Tosheva Antoine Kies Inna Taskaeva 《International journal of environmental analytical chemistry》2013,93(9):653-661
A time-saving and sensitive method for monitoring low concentration (activities) of 210Pb, 232Th, and 230Th and 238U, 234U, and 235U in water samples has been developed. Through the combination of co-precipitation and extraction chromatography by 3M RAD disks and UTEVA (Eichrom) columns effective radiochemical separation of the analytes was carried out. Thorium and uranium activities were determined by alpha spectrometry and lead activity by LSC, respectively. The minimal detectable activities obtained were 0.6?Bq?m?3 for uranium, 0.29?Bq?m?3 for thorium, and 2.5?Bq?m?3 for 210Pb. More than 150 different waters were analysed for uranium content and only 30 for lead and thorium. The investigations are still in progress. 相似文献
7.
For99Tc separation from environmental samples, liquid-liquid extraction, ion-exchange chromatography and coprecipitation, have been described. Although these methods are removing matrix elements, some combinations of them is necessary for purification and concentration of Tc. Besides, the procedures are time-consuming and generally a week or more is needed to purify Tc in the samples. In this study, a novel extraction chromatographic resin for the separation and preconcentration of Tc from several kinds of solutions is described. The material is shown to retain Tc efficiently and selectively from these solutions. Sorbed Tc is readily recovered using 5 ml of 12M HNO3 and the recoveries with95mTc are more than 97% for all sample solutions. 相似文献
8.
A new an innovative separation method has been developed using N-n-octylaniline (liquid anion exchanger) coated on silica gel. Ruthenium(III) has been extracted quantitatively from 0.05 M hydrochloric acid, striped with aqueous solution of various acids and then determined by spectrophotometric method. Mutual separation scheme for ruthenium(III), iridium(III) and osmium(VIII) has been developed. Ruthenium(III) has been separated from commonly associated elements. Different parameter are studied viz effect of acid concentration, reagent concentration, striping agent, flow rate, foreign ion and synthetic mixture corresponding to alloys. Validity of method has been verified by separation of ruthenium(III) from fissium alloy. 相似文献
9.
Ahmad Hosseini-Bandegharaei Mohammad Saeid Hosseini Yousef Jalalabadi Mehdi Nedaie Masoud Sarwghadi Akram Taherian 《International journal of environmental analytical chemistry》2013,93(1):108-124
The present work proposes the use of a novel extractant-impregnated resin (EIR) as an adsorbent in trace separation and pre-concentration of U(VI) and Th(IV) ions. The new EIR was prepared by impregnating carminic acid onto Amberlite XAD-16 resin beads. The morphology of new EIR was studied by BET surface area measurements and SEM micrographs. A column packed with CA/XAD-16 was used for selective separation and pre-concentration of the metal ions. Maximum adsorption of Th(IV) and U(VI) ions occurred at pHs of 3.50–5.75 and 3.75–6.50, respectively. The adsorbed metals could be eluted sequentially using 0.55?mol?L?1 HCl for U(VI) and 2.25?mol?L?1 HCl for Th(IV). The dynamic capacity of EIR was found to be 0.832 and 0.814?mmol?g?1 for Th(IV) and U(VI), respectively. The tolerance limit of some foreign ions was also studied. The proposed method showed a good performance in analyzing geological reference materials and a synthetic seawater sample. Furthermore, the above procedure was successfully employed for the analysis of natural water samples. 相似文献
10.
The use of a commercially available chelating resin with NTA-type functional groups for concentration of trace metals from seawater is described. Trace metal recoveries from this NTA Superflow chelating resin are pH dependent. At a pH of ≤2 only iron(III) and copper are quantitatively recovered from the resin. Iron(II) cannot be quantitatively recovered from this resin below a pH of 5. However, oxidation of acidified seawater samples (pH 1.7) with H2O2 prior to loading onto the resin has been demonstrated to allow quantitative recovery of total dissolved iron. Deferrioxamine and Rhodoturlic Acid, two commercially available siderophores were used to investigate the effect of strong Fe(III)-binding organic ligands on the ability to retain iron at different pH values. Acidification of seawater samples to pH 1.7 dissociates the iron complexed to these organic ligands, thereby allowing total dissolved iron and copper to be determined. Acidified samples from Monterey Bay were analyzed by a flow injection method coupled to ICP-SFMS detection using the NTA Superflow resin in the pre-concentration step. Results from this study show that when seawater samples are stored acidified (pH 1.7) over time, a portion of iron(III) is reduced to iron(II), thus necessitating the use of H2O2 to reoxidize the Fe(II) to Fe(III) prior to analysis. Total dissolved concentrations of iron and copper can be directly obtained on seawater samples at pH 1.7 with this method, eliminating the need to buffer the sample to a higher pH prior to column loading. This resin has the potential to be used in shipboard or in situ flow injection methods. 相似文献
11.
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results. 相似文献
12.
13.
The assay of malondialdehyde (MDA) is widely used in clinical chemistry laboratories to investigate lipid peroxidation in oxidative pathologies. In the present work, the thiobarbituric acid (TBA) reaction was carried out on plasma, human erythrocytes and fibroblasts. The reagents used were those of the fluorimetry MDA kit manufactured by Sobioda. We have defined the application of this kit to high-performance liquid chromatography. This adaptation satisfied the criteria of good analytical practice. The detection limit was 2.5 pmol per injection. The retention time of the MDA-TBA2 peak (4.96 +/- 0.07 min) led to excellent resolution of the complex. The within-assay (6-12%) and between-assay (11-12%) precisions were satisfactory. The analytical recovery of MDA after spiking samples of human plasma with tetraethoxypropane standards varied from 70 to 100%. The mean lipoperoxide concentration determined in 32 healthy adults (20-40 years) was 1.04 +/- 0.23 mumol l-1 in plasma. Applied to the erythrocytes of fifteen laboratory workers, the method furnished physiological values of 0.59 +/- 0.21 mumol l-1. Concentrations were significantly higher in chronic renal dialysis patients (4.15 +/- 2.35 mumol l-1. The MDA content of fibroblasts cultured in standard medium was 0.38 +/- 0.04 mumol per g of protein and increased (5.78 +/- 1.38 mumol per g of protein) if the cells were grown in an iron-enriched medium. This accurate high-performance liquid chromatographic method for detection of MDA is the first one which can be applied to plasma, red blood cells and cultured cells. This technique will prevent false positives and should make inter-laboratory comparisons possible. 相似文献
14.
Small amounts of polyvinyl alcohol (PVA; 0.5-1.5 wt.%) added to extraction resin was synthesized by suspension polymerization. Their effects on the separation of rare earths (RE) were then investigated by conducting a relative comparison with the performance of pure extraction resin. The supporter and extractant of extraction resin were styrene-divinyl benzene copolymer and 2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester (HEH[EHP]), respectively. The size of PVA added extraction resin was reduced by 40% particle size of pure extraction resin. Furthermore, a higher level of PVA addition, shorter effluent range and smaller resolution values were shown in the extraction. In constant PVA added extraction resin, more diluted effluent concentration, longer effluent range and bigger resolution values were shown in the extraction. This could be the result of the bonding force between the rare earths and the extraction resin due to the nature of the interaction between the OH− group in PVA and the OH− group in extractants such as HEH[EHP]. Thus, the bonding force between the RE and extractants was determined by the level of PVA in the resins and the acidity of the effluent solution became another important factor in the extraction performance of the rare earths. As a result, the optimal level of PVA addition and the concentration of effluent for RE (Gd and Tb) separation were determined to be 0.5 wt.% of PVA and 0.05 M HCl of effluent, respectively. 相似文献
15.
Summary An improved analytical method, reversed-phase high-performance liquid chromatography on a narrow-bore C18 column, has been developed for the simultaneous determination of genistein, daidzein, formononetin, and biochanin A. The
method was validated in terms of detection limits, quantitation limits (LOQ), linearity, and precision.LOQ in the 0.04–0.1 μg mL−1 range were calculated, enabling determination of these compounds of nutritional concern at trace levels. Good linearity was
demonstrated over three orders of magnitude of concentration for each analyte (r
2=0.998–1.000). The intra-day repeatability was evaluated in terms ofRSD (%) at two concentration levels for each analyte (RSD (%) <1.8%). Good inter-day reproducibility of data was proved by performing homoscedasticity and ANOVA tests (P>0.05 at the 95% confidence level). The method was applied to the determination of genistein and daidzein in yellow soybeans,
after optimization of the method for extraction of isoflavonoid aglycones from soybeans by experimental design, i.e. central
composite design. Extraction recoveries up to 87±4% were obtained when the corresponding glycosidic forms (genistin and daidzin)
were added to soybean samples. 相似文献
16.
N,N,N',N'-tetraoctyl diglycolamide (TODGA) has been used as the stationary phase in an extraction chromatography resin (XCR) material prepared for evaluating the uptake and the separation behaviour of (90)Y and (90)Sr from acidic feeds. Chromosorb-W was used as the solid support material while the feed solution was usually 4M HNO(3). The batch uptake studies have suggested almost no Sr(II) uptake while Y(III) uptake increased with acidity up to 4M HNO(3) beyond which a decrease in the K(d,w) values were observed. Column studies were carried out and breakthrough profiles were obtained for both Y(III) and Sr(II). No breakthrough of Y(III) was noticed even when >50 column volumes of the feed (carrier free (90)Y at 4 M HNO(3)) was passed through the column while about 20 column volumes were required for the breakthrough of Y(III) when the feed contained 1 g/L Y in 4 M HNO(3) spiked with (90)Y tracer. The reusability of the column was also studied which indicated in the deterioration of the column performance as shown by the sharp fall in the breakthrough volumes and was attributed to the probable leaching of the reagent from the support material. The role of absorbed dose was also investigated for Y(III) uptake. Separation of carrier free (90)Y tracer was carried out by loading the column with (90)Sr and eluting with 0.01M solutions of HNO(3) as well as EDTA. The purity of the product was ascertained by half-life method. 相似文献
17.
Pankaj Maharjan Milton T.W. Hearn W. Roy Jackson Kirthi De Silva Brad. W. Woonton 《Journal of chromatography. A》2009,1216(50):8722-8729
A temperature-responsive ion-exchange resin (ItBA) has been prepared by grafting poly(N-isopropylacrylamide-co-acrylic acid-co-tert-butylacrylamide; ItBA) onto cross-linked agarose. A carboxymethylated ion exchanger (CM) of similar charge density was also prepared. Maximum adsorption capacities (Bmax) for lactoferrin at 20 °C and 50 °C were determined for both resins by batch adsorption procedures. Dynamic adsorption and desorption characteristics of the CM and ItBA with lactoferrin were established, as well as the ability of ItBA to selectively adsorb and desorb lactoferrin in the presence of other proteins. With the CM-agarose resin there was no significant difference between the Bmax values obtained at 20 °C and 50 °C. However, for the agarose-based ItBA resin the Bmax value at 50 °C was almost three times higher than the Bmax value at 20 °C. Dynamically, lactoferrin adsorbed to the ItBA packed column at 50 °C with a significant proportion of the adsorbed lactoferrin desorbed by reducing the temperature to 20 °C. In addition, anionic proteins did not adsorb to the ItBA packed column, and did not interfere with the dynamic adsorption/desorption behaviour of lactoferrin. These results indicate that this new temperature-responsive agarose-based ItBA resin has potential for the fractionation of whey proteins, with good selectivity for cationic proteins. 相似文献
18.
Twenty-one commercially available phenyl type RPLC packing materials have been characterized in terms of their surface coverage, hydrophobic selectivity, shape selectivity, hydrogen bonding capacity, ion exchange capacity at pH 2.7 and 7.6 and aromatic selectivity (i.e. pi-pi interaction). The phases have been compared to their corresponding C-alkyl phases, three pentafluorophenyl phases and a series of experimental phenyl phases of known bonding chemistry. Principal component analysis has been used to provide a graphical comparison of the differences and similarities between the phases. The phase's aromatic selectivity was found to be dependent on the length of the alkyl spacer between the silicon atom and the phenyl ring. 相似文献
19.
N,N,N′,N′-tetraoctyl diglycolamide (TODGA) has been used as the stationary phase in the extraction chromatographic separation of actinides and other metal ions from pure nitric acid as well as from simulated high-level waste (SHLW). Chromosorb-W was found to be a better support material amongst the different solid supports evaluated viz. chromosorb-W, chromosorb-102, XAD-4 and XAD-7. Uptake profiles of various metal ions, such as U(VI), Pu(IV), Am(III), Eu(III), Fe(III), Sr(II) and Cs(I) were obtained as a function of acidity by batch studies using TODGA/chromosorb-W. Effect of macro concentration of Nd, Fe and U suggested that the uptake of Am(III) is mainly influenced by the presence of trivalent lanthanide ions. Breakthrough capacity of the resin material for Am(III) in presence of macro amount of Eu(III) was determined in the successive cycles of loading and elution. Loading capacity of the column was found to be 20 mg of Eu/g of the resin material. Elution studies of Am(III) suggested that 0.01 M EDTA was effective amongst different eluents used. 相似文献