首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Modern extraction technique-pressurized liquid extraction (PLE) was optimised for extraction of lycorine and galanthamine (Amaryllidaceae alkaloids) from Narcissus jonquilla ‘Pipit’. Crude extracts were purified on Oasis MCX cartridges, and the alkaloids eluted with 80-100% recoveries using methanol-10% ammonia solution (3:1, v/v). Quantitative results were obtained by both HPTLC-densitometry on silica gel plates and RP-HPLC with diode array (DAD) on XTerra C18 stationary phase. Both methods were fully validated in terms of specificity, precision (including intra- and inter-day measurements), LOD and LOQ values, correlation of UV spectra and linearity of calibration curves. The methods were also well correlated each other with correlation coefficients (r) 0.98823 and 0.99081, respectively, for the mean values of galanthamine and lycorine.Among the investigated solvents methanol and 1% tartaric acid methanolic solution at default conditions (120 °C, p = 60 bar, time: 10 min, one static cycle) permit the highest yields of the total sum of the alkaloids, whereas for toluene the lowest amounts were measured. Lycorine to galanthamine mean ratios were dependant on the type of solvent used, and in toluene galanthamine and related alkaloids were preferably extracted.In temperature experiments for galanthamine, the levels of this compound increased from the temperature of 20 till 150 °C in the investigated solvent systems, then decreased with slight increase from the temperature of 175 to 200 °C in 1% tartaric acid methanolic solution. When lycorine was analysed, similar trends were observed, however the maximum of the concentration was measured at a temperature about 125 °C. The ratios of the mean values of these two compounds differed in temperature-dependant experiments in both solvent systems.Further more, two TLC with bioautography approaches were used in screening for anticholinesterese properties of the extracts. No qualitative differences were found among the different solvent extracts, and AChE inhibition was correlated with galanthamine and related compounds.In conclusion, optimised PLE was much more effective than previously applied hot-solvent extraction, microwave-assisted extraction (MAE) or ultrasound-assisted extraction (USAE).  相似文献   

2.
This work reports the preparation of molecularly imprinted polymer (MIP) particles for selective extraction and determination of selenium ions from aqueous media. Polymerization was achieved in a glass tube containing SeO2, o-phenylenediamine, 2-vinylpyridine (VP), ethyleneglycoldimethacrylate (EDMA), 2,2′-azobisisobutyronitrile (AIBN). The polymer block obtained was ground and sieved (55-75 μm) and the Se-o-phenylenediamine complex was removed from polymer particles by leaching with 2 M of HCl, which leaves a cavity in the polymer particles. The polymer particles both prior to and after leaching have been characterized by IR and thermogravimetric (TG) studies. The effect of different parameters, such as pH, extraction time, type and least amount of eluent for elution of complex from polymer were evaluated. Extraction efficiencies >99% were obtained by elution of the polymers with 15 mL of methanol-acetonitrile mixture (1:2, v/v). The limit of detection of the proposed method followed by hydride generation atomic absorption spectroscopy (HG-AAS) was found to be 3.3 μg L−1 and a dynamic linear range (DLR) of 10-200 μg L−1 was obtained. The relative standard deviations (R.S.D.s) at 30.0 μg L−1 of Se were below than 8.1%. The influence of various cationic interferences on percent recovery of complex was studied. The method was applied to the recovery and determination of selenium in different real samples.  相似文献   

3.
Xu X  Ye H  Wang W  Yu L  Chen G 《Talanta》2006,68(3):759-764
Four flavonoids (rutin, hyperoside, quercitrin and quercetin) in Houttuynia cordata Thunb. and Saururus chinensis (Lour.) Bail. were determined by capillary electrophoresis with wall-jet amperometric detection. The working electrode was a 500 μm diameter carbon disc electrode and the detection potential was +0.95 V (versus Ag/AgCl). Effects of several important factors, such as the running buffer and its corresponding pH and concentration, separation voltage, injection time were investigated to acquire the optimum conditions for separation of these four flavonoids. Baseline separation for the four flavonoids was obtained within 21 min in a 60 cm length capillary at a separation voltage of 15 kV with a 60 mmoL/L Na2B4O7-120 mmoL/L NaH2PO4 buffer (pH 8.8) as running buffer. The relationship between peak currents and analyte concentrations was linear over about two orders of magnitude with detection limits (defined as S/N = 3) ranging from 0.02 to 0.05 μg/mL for all analytes. This method was applied for the determination of the above four flavonoids in H. cordata Thunb. and S. chinensis (Lour.) Bail. with simple extraction procedures, and the assay results were satisfactory.  相似文献   

4.
N-Methylimidazolium modified magnetic particles (MIm-MPs) were prepared and applied in the solid phase extraction of genomic deoxyribonucleic acid (DNA) from genetically modified soybeans. The adsorption of MIm-MPs for DNA mainly resulted from the strong electrostatic interaction between the positively charged MPs and the negatively charged DNA. The elution of DNA from MPs–DNA conjugates using phosphate buffer resulted from the stronger electrostatic interaction of phosphate ions with MPs than DNA. In the extraction procedure, no harmful reagents (e.g. phenol, chloroform and isopropanol, etc.) used, high yield (10.4 μg DNA per 30 mg sample) and high quality (A260/A280 = 1.82) of DNA can be realized. The as-prepared DNA was used as template for duplex-polymerase chain reaction (PCR) and the PCR products were analyzed by a sieving capillary electrophoresis method. Quick and high quality extraction of DNA template, and fast and high resolution detection of duplex PCR products can be realized using the developed method. No toxic reagents are used throughout the method.  相似文献   

5.
A new method involving headspace single-drop microextraction (SDME) and capillary electrophoresis (CE) is developed for the preconcentration and determination of ammonia (as dissolved NH3 and ammonium ion). An aqueous microdrop (5 μL) containing 1 mmol/L H3PO4 and 0.5 mmol/L KH2PO4 (as internal standard) was used as the acceptor phase. Common experimental parameters (sample and acceptor phase pH, extraction temperature, extraction time) affecting the extraction efficiency were investigated. Proposed SDME-CE method provided about 14-fold enrichment in about 20 min. The calibration curve was linear for concentrations of NH4+ in the range from 5 to 100 μmol/L (R2 = 0.996). The LOD (S / N = 3) was estimated to be 1.5 μmol/L of NH4+. Such detection sensitivity is high enough for ammonia determination in common environmental and biological samples. Finally, headspace SDME was applied to determine ammonia in human blood, seawater and milk samples with spiked recoveries in the range of 96-107%.  相似文献   

6.
An efficient microwave-assisted extraction (MAE) technique has been developed to extract scutellarin from Erigeron breviscapus for rapid determination by high-performance liquid chromatography (HPLC). The maximum yield of scutellarin reached 1.02% in 40 min under the optimal MAE conditions with 80 °C of extraction temperature and 1:10 (w/v) of the solid/liquid ratio. The MAE showed obvious advantages in terms of short duration and high efficiency to extract scutellarin in comparison with heat-flux extraction. The mechanism of the enhanced extraction by microwave assistance was discussed by detecting particle size and specific surface area of plant materials and observing cell destruction of plant material by light microscopy and scanning electron microscopy. The results showed that the plant materials were significantly destroyed due to the cell rupture after MAE treatment. Afterward, the method validation for HPLC-UV analysis was developed. Calibration range was 0.1-100 μg mL−1 for scutellarin, and correlation coefficient R was 0.9993. Limit of detection was less than 0.01 μg mL−1. The intra- and inter-day relative standard deviation (R.S.D.) of scutellarin detection ranged from 1.58% to 2.96% and from 3.32% to 4.19%, respectively. The recovery of the method for scutellarin ranged from 96.7% to 101.9%.  相似文献   

7.
Zhou Q  Gao Y  Xie G 《Talanta》2011,85(3):1598-1602
Present study described a simple, sensitive, and viable method for the determination of bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in water samples using temperature-controlled ionic liquid dispersive liquid-phase microextraction coupled to high performance liquid chromatography-fluorescence detector. In this experiment, 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) was used as the extraction solvent, and bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol were selected as the model analytes. Parameters affecting the extraction efficiency such as the volume of [C8MIM][PF6], dissolving temperature, extraction time, sample pH, centrifuging time and salting-out effect have been investigated in detail. Under the optimized conditions, good linear relationship was found in the concentration range of 1.0-100 μg L−1 for BPA, 1.5-150 μg L−1 for 4-NP, and 3-300 μg L−1 for 4-OP, respectively. Limits of detection (LOD, S/N = 3) were in the range of 0.23-0.48 μg L−1. Intra day and inter day precisions (RSDs, n = 6) were in the range of 4.6-5.5% and 8.5-13.3%, respectively. This method has been also successfully applied to analyze the real water samples at two different spiked concentrations and excellent results were obtained.  相似文献   

8.
This study developed a headspace liquid-phase microextraction (LPME) method by using a single aqueous drop in combination with high performance liquid chromatography (HPLC)-UV detection for the determination of methamphetamine (MAP) and amphetamine (AP) in urine samples. The analytes, volatile and basic, were released from sample matrix into the headspace first, and then protonated and dissolved in an aqueous H3PO4 drop hanging in the headspace by a HPLC syringe. After extraction, this drop was directly injected into HPLC. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the investigated concentration range of 1.0-1500 μg L−1, repeatability of the extraction (R.S.D. < 5%, n = 6), and low detection limits (0.3 μg L−1 for both analytes). Enrichment factors of about 400-fold and 220-fold were achieved for MAP and AP, respectively, at optimum conditions. The feasibility of the method was demonstrated by analyzing human urine samples.  相似文献   

9.
Hui-Xin Liu  Ying Hu  Yong Liu  Ling Yang 《Talanta》2009,79(5):1433-1336
A simple and sensitive method for determination of the O-demethylation activity of rat, dog, minipig, and human liver micrsomes toward paeonol using ultra-performance liquid chromatography with mass detection (UPLC-MS) has been developed. The method uses chemically synthesized O-demethylated metabolite of paeonol (2,4-dihydroxyacetophenone, DHA) as a standard for method validation. Validation was done with respect to specificity, linearity, detection limit, recovery, stability, precision and accuracy. The chromatographic separation was achieved on a UPLC BEH C18 column (50 mm × 2.1 mm i.d., 1.7 μm), with phase of acetonitrile-water (ratio 30:70). Selective ion reaction (SIR) monitor was specific for paeonol, DHA and I.S. The method was specific since there were no interference peaks from the reaction matrix. The calibration curve for DHA was linear from 0.5-100 μM with r2 = 0.9999. The newly developed method has good precision and accuracy. The method was successfully used to determine the kinetics of DHA activities toward paeonol in liver microsomes from different species. Dog liver microsomes (DLMs) were the most active in paeonol O-demethylation (709.7 pmol/min/mg protein) followed by rat liver microsomes (RLMs) (579.6 pmol/min/mg protein), HLMs (569.3 pmol/min/mg protein), and then minipig liver microsomes (PLMs) (417.3 pmol/min/mg protein). The developed method was appropriated for rapid screening paeonol O-demethylation activity in liver microsomes from different species.  相似文献   

10.
In this work a parathion selective molecularly imprinted polymer was synthesized and applied as a high selective adsorber material for parathion extraction and determination in aqueous samples. The method was based on the sorption of parathion in the MIP according to simple batch procedure, followed by desorption by using methanol and measurement with square wave voltammetry. Plackett-Burman and Box-Behnken designs were used for optimizing the solid-phase extraction, in order to enhance the recovery percent and improve the pre-concentration factor. By using the screening design, the effect of six various factors on the extraction recovery was investigated. These factors were: pH, stirring rate (rpm), sample volume (V1), eluent volume (V2), organic solvent content of the sample (org%) and extraction time (t). The response surface design was carried out considering three main factors of (V2), (V1) and (org%) which were found to be main effects. The mathematical model for the recovery percent was obtained as a function of the mentioned main effects. Finally the main effects were adjusted according to the defined desirability function. It was found that the recovery percents more than 95% could be easily obtained by using the optimized method. By using the experimental conditions, obtained in the optimization step, the method allowed parathion selective determination in the linear dynamic range of 0.20-467.4 μg L−1, with detection limit of 49.0 ng L−1 and R.S.D. of 5.7% (n = 5). Parathion content of water samples were successfully analyzed when evaluating potentialities of the developed procedure.  相似文献   

11.
A hollow fiber renewal liquid membrane (HFRLM) extraction method to determine cadmium (II) in water samples using Flame Atomic Absorption Spectrometry (FAAS) was developed. Ammonium O,O-diethyl dithiophosphate (DDTP) was used to complex cadmium (II) in an acid medium to obtain a neutral hydrophobic complex (ML2). The organic solvent introduced to the sample extracts this complex from the aqueous solution and carries it over the poly(dimethylsiloxane) (PDMS) membrane, that had their walls previously filled with the same organic solvent. The organic solvent is solubilized inside the PDMS membrane, leading to a homogeneous phase. The complex strips the lumen of the membrane where, at higher pH, the complex Cd-DDTP is broken down and cadmium (II) is released into the stripping phase. EDTA was used to complex the cadmium (II), helping to trap the analyte in the stripping phase. A multivariate procedure was used to optimize the studied variables. The optimized variables were: sample (donor phase) pH 3.25, DDTP concentration 0.05% (m/v), stripping (acceptor phase) pH 8.75, EDTA concentration 1.5 × 10−2 mol L−1, extraction temperature 40 °C, extraction time 40 min, a solvent mixture N-butyl acetate and hexane (60/40%, v/v) with a volume of 100 μL, and addition of ammonium sulfate to saturate the sample. The sample volume used was 20 mL and the stripping volume was 165 μL. The analyte enrichment factor was 120, limit of detection (LOD) 1.3 μg L−1, relative standard deviation (RSD) 5.5% and the working linear range 2-30 μg L−1.  相似文献   

12.
A sensitive on-chip acetylcholinesterase (AChE) assay that serves as a basis for the development of a fully integrated on-chip AChE-inhibitor detection assay is presented. The sequential steps required for the on-chip analysis process were integrated into a microchip. Transport and mixing of the reagents occurred by a combination of electroosmosis and electrophoresis using computer-controlled electrokinetic transport. AChE-catalyzed hydrolysis of acetylthiocholine to thiocholine was determined by on-chip reaction of thiocholine with eosinmaleimide, and the resulting thioether was electrophoretically separated and detected by laser-induced fluorescence (LIF). Enzyme-substrate mixing and reaction by confluent flow of reagents was compared with electrophoretically mediated microanalysis (EMMA), based on injection of an enzyme plug, and the utilization of differences in electrophoretic mobility as a driving force for efficient mixing and reaction. Both methods yielded similar results, however the EMMA-plug technique is preferable. The EMMA-plug technique was optimized for length and pushing time of enzyme plug, length of dyes mixture plug, acetylthiocholine concentration, and detector location. Detection of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and paraoxon, two AChE inhibitors, was demonstrated by off-chip mixing of the inhibitor and AChE, followed by the on-chip AChE assay. Limit of detection of VX for 5.5 min incubation and of paraoxon for 8 min incubation was 4 × 10−10 and 4 × 10−7 M, respectively. Utilization of the AChE microchip assay for inhibition kinetics was demonstrated also by evaluation of the inhibitor-enzyme bimolecular reaction constant (ki). The evaluated ki values for VX and paraoxon for AChE from the electric eel were 3.5 × 107 and 1.7 × 105 M−1 min−1, respectively, conforming well to reported values obtained by bulk methods.  相似文献   

13.
There is an increasing need to develop biosensors for the detection of harmful pesticide residues in food and water. Here, we report on a versatile strategy to synthesize functionalized graphene oxide nanomaterials with abundant affinity groups that can capture histidine (His)-tagged acetylcholinesterase (AChE) for the fabrication of paraoxon biosensors. Initially, exfoliated graphene oxide (GO) was functionalized by a diazonium reaction to introduce abundant carboxyl groups. Then, Nα,Nα-bis(carboxymethyl)-l-lysine hydrate (NTA-NH2) and Ni2+ were anchored onto the GO based materials step by step. AChE was immobilized on the functionalized graphene oxide (FGO) through the specific binding between Ni-NTA and His-tag. A low anodic oxidation potential was observed due to an enhanced electrocatalytic activity and a large surface area brought about by the use of FGO. Furthermore, a sensitivity of 2.23 μA mM−1 to the acetylthiocholine chloride (ATChCl) substrate was found for our composite covered electrodes. The electrodes also showed a wide linear response range from 10 μM to 1 mM (R2 = 0.996), with an estimated detection limit of 3 μM based on an S/N = 3. The stable chelation between Ni-NTA and His-tagged AChE endowed our electrodes with great short-term and long-term stability. In addition, a linear correlation was found between paraoxon concentration and the inhibition response of the electrodes to paraoxon, with a detection limit of 6.5 × 10−10 M. This versatile strategy provides a platform to fabricate graphene oxide based nanomaterials for biosensor applications.  相似文献   

14.
To assess the potential risks associated with the environmental exposure of β-lactam antibiotics (BLAs), the monitoring of the occurrence, distribution, and fate of these emerging contaminants in the environment is required. Herein, we demonstrate a molecularly imprinted solid-phase extraction (MISPE) method for selective and reliable screening of trace BLAs in river and tap water. By developing a low-temperature photopolymerization, highly selective molecularly imprinted polymers (MIPs) for five BLAs (penicillin G, amoxicillin, ampicillin, nafcillin and mezlocillin) were synthesized. Nafcillin was chosen as a pseudo template to make the MIP sorbent (Nafc-MIP), which was used in pseudo-template MISPE for preconcentration of the other four BLAs from river and tap water. The application of pseudo-template MISPE overcomes the template bleeding, which significantly elevates the sample background and restricts the application of MIP for detection of the target BLA below 2 μg/L. The average recoveries of BLAs are in the range of 60–90% when Nafc-MIP was adopted as the selective MISPE sorbent. The developed method was validated, and applied to the screening of trace β-lactam antibiotics in river and tap water. The linearity of the calibration curve for each BLA was observed over the range of 0.1–20 μg/L (r > 0.998). The β-lactam antibiotics were found within the range of 0–9.56 μg/L in river water at the downstream of antibiotics manufacturers, and none were detected in the tap water.  相似文献   

15.
A highly selective, and low cost extractive spectrofluorometric method has been developed for determination of trace concentrations of chromium (III & VI) in water samples using the fluorescent reagent tetraphenylphosphonium bromide (TPP+·Br). The method was based upon solvent extraction of the produced ion associate [TPP+·CrO3Cl] of TPP+·Br and halochromate in aqueous HCl and measuring the fluorescence quenching of TPP+·Br in chloroform at λex/em = 242/305 nm. The fluorescence intensity of TPP+Br decreased linearly on increasing the chromium (VI) concentration in the range of 1-114 μg L−1. The limits of detection (LOD) and quantification (LOQ) of chromium (VI) were 0.43 and 1.42 μg L−1, respectively. Chromium (III) species after oxidation to chromium (VI) with H2O2 in alkaline solution were also determined. Chemical speciation of chromium (III & VI) species at trace levels was achieved. The method was applied for analysis of chromium in certified reference material (IAEA Soil-7) and in tap- and wastewater samples and compared successfully (>95%) with the inductively coupled plasma-mass spectrometry (ICP-MS) results.  相似文献   

16.
A novel solid phase extraction technique for the speciation of trace dissolved Fe(II) and Fe(III) in environmental water samples was developed by coupling micro-column packed with N-benzoyl-N-phenylhydroxylamine (BPHA) loaded on microcrystalline naphthalene to electrothermal vaporization inductively coupled plasma-optical emission spectrometry (ETV-ICP-OES). Various influencing factors on the separation and preconcentration of Fe(II) and Fe(III), such as the acidity of the aqueous solution, sample flow rate and volume, have been investigated systematically, and the optimized operation conditions were established. At pH 3.0 Fe(III) could be selectively retained by micro-column (20 mm × 1.4 mm, i.d.) packed with BPHA immobilized on microcrystalline naphthalene, and Fe(II) passed through the micro-column. Both Fe(II) and Fe(III) could be adsorbed by the micro-column at pH 6.5. Thus, the total Fe could be determined without the need for preoxidation of Fe(II) to Fe(III). The retained Fe(III) or the Fe(II) and Fe(III) was subsequently eluted by 0.1 ml of 1 mol l−1 HCl. The adsorption capacity of the solid phase adsorption material was found to be 45.0 mg g−1 for Fe(III) at pH 3.0 and 65.3 mg g−1 for Fe(II) at pH 6.5, respectively. The detection limit (3σ) of 0.053 μg l−1 was obtained with a practical enrichment factor of 156 at a sample volume of 17 ml. The relative standard deviations of 4.2% and 4.6% (CFe(III) = CFe(II) = 10 μg l−1, n = 7) for Fe(III) and total iron were found, respectively. The method was successfully applied to the determination of trace Fe(II) and Fe(III) in environmental water samples (East Lake water, local tap water and mineral water). In order to validate the method, the developed method was applied to the determination of total iron in certified materials of NIES NO.10-b rice flour and GBW07605 tea leaves, and the results obtained were in good agreement with the certified values.  相似文献   

17.
Ganzera M  Lanser C  Stuppner H 《Talanta》2005,66(4):889-894
Ephedra sinica (Ma Huang) preparations have recently gained a lot of attention because of serious side effects associated with their prolonged consumption. Citrus aurantium var. amara is now used as an alternative, despite the fact that similar side effects are suspected. We have developed and validated the first analytical procedure for the simultaneous determination of all major alkaloids from both species. Using the ion-pairing reagent SDS, a C-18 stationary phase (3 μm material) and a pH-gradient for elution enabled the baseline separation of six alkaloids ((±)-octopamine, (±)-synephrine, tyramine, (−)-norephedrine, (+)-pseudoephedrine and (−)-ephedrine) within less than 30 min. The method is sensitive (LOD ≤ 4.6 ng and LOQ ≤ 16.2 ng on-column), selective (l-tyrosine and l-phenylalanine, two closely related amino acids did not interfere), accurate (recovery rates of spiked samples were between 97.5 and 102.0%), repeatable (σrel ≤ 4.6%) and precise (intra-day variation ≤7.7%, inter-day variation ≤7.0%). Without the need of a special sample treatment different matrices (plant material, commercial products) were successfully analyzed for their alkaloid content. Dominant alkaloids were (−)-ephedrine (0.9-1.6%) and/or (±)-synephrine (0.1-3.0%). Whether a product contained Ephedra-alkaloids or not could be determined in all investigated samples unambiguously.  相似文献   

18.
A simple, rapid and sensitive procedure using solid phase extraction and capillary zone electrophoresis for the determination of propranolol (a beta-blocker) and one of its metabolites, N-desisopropylpropranolol, has been developed and validated. The optimum separation of both analytes was obtained in a 37 cm × 75 μm fused silica capillary using 20 mmol/L phosphate buffer (pH 2.2) as electrolyte, at 25 kV and 30 °C, and hydrodynamic injection for 5 s. Prior to the electrophoretic separation, the samples were cleaned up and concentrated using a C18 cartridge and then, eluted with methanol, allowing a concentration factor of 30.Good results were obtained in terms of precision, accuracy and linearity. The limits of detection were 28 and 30 μg/L for N-desisopropylpropranolol and propranolol, respectively. Additionally, a robustness test of the method was carried out using the Plackett-Burman fractional factorial model with a matrix of 15 experiments.The presented method has been applied to the determination of both compounds in human urine.  相似文献   

19.
In this study, a simple and reliable HPLC method for the qualitative and quantitative analysis of cardiac glycosides in Digitalis lanata Ehrh. raw material was developed and applied to healthy and phytoplasma-infected plants. The target analytes cover a broad range of secondary metabolites, including primary, secondary and tertiary glycosides and the corresponding aglycones. The sample preparation was carried out by sonication of the plant material with 70% (v/v) aqueous methanol at room temperature, followed by reversed-phase solid-phase extraction purification from interfering pigments. The HPLC analyses were performed on a Symmetry C18 column (75 mm × 4.6 mm I.D., 3.5 μm), with a gradient elution composed of water and acetonitrile, at a flow rate of 1.0 mL/min. The column temperature was set at 20 °C and the photodiode array detector monitored the eluent at 220 nm. The method was validated with respect to ICH guidelines and the validation parameters were found to be highly satisfactory. The application of the method to the analysis of D. lanata leaves indicated that air-drying was the optimum method for raw material processing when compared with freeze-drying. The analysis of healthy and phytoplasma-infected plants demonstrated that the secondary metabolite mainly affected by the pathogen presence was lanatoside C (153.2 μg/100 mg versus 76.1 μg/100 mg). Considering the importance of D. lanata plant material as source of cardiac glycosides, the developed method can be considered suitable for the phytochemical analysis and for the quality assurance of D. lanata used for pharmaceutical purpose.  相似文献   

20.
Ibrahim S.I. Adam 《Talanta》2009,77(3):1160-1164
A newly simple flow injection wetting-film extraction system coupled to flame atomic absorption spectrometry (FAAS) has been developed for trace amount of cadmium determination. The sample was mixed on-line with sodium diethyl dithiocarbamate and the produced non-charged Cd(II)-diethyl dithiocarbamate (DDTC) chelate complex was extracted on the thin film of diisobutyl ketone (DIBK) on the inner wall of the PTFE extraction coil. The wetting-film with the extracted analyte was then eluted by a segment of the cover solvent, and transported directly to the FAAS for evaluation. All the important chemical and flow parameters were optimized. Under the optimized conditions an enhancement factor of 35, a sample frequency of 22 h−1 and a detection limit of cL = 0.7 μg l−1 Cd(II) were obtained for 60 s preconcentration time. The calibration curve was linear over the concentration range 1.5-45.0 μg l−1 Cd(II) and the relative standard deviation, R.S.D. (n = 10) was 3.9%, at 10.0 μg l−1 concentration level. The developed method was successfully applied to cadmium determination in a variety of environmental water samples as well as waste-water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号