首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
An electrochemiluminescent cholesterol disposable biosensor has been prepared by the formation of assembled layers on gold screen-printed cells. The detection layer is based on the electro-formation of new luminol copolymers with different synthesized biotinylated pyrroles prepared by click-chemistry, offering a new transduction layer with new electroluminescent properties on biosensors. The electrochemiluminescence (ECL) luminol copolymers are electroformed by cyclic voltammetry (five cycles) at pH 7.0 uses a10−3 M biotinylated pyrrole–luminol ratio of 1:10 in PBS buffer. With respect to the recognition layer, cholesterol oxidase was biotinylated by incubation with biotin vinyl sulfone, and immobilized on the copolymer by avidin–biotin interaction. The analytical signal of the biosensor is the ECL enzymatic initial rate working in chronoamperometric mode at 0.5 V excitation potential with 10 s between pulses at pH 9.5. The disposable device offers a cholesterol linear range from 1.5 × 10−5 M to 8.0 × 10−4 M with a limit of detection of 1.47 × 10−5 M and accuracy of 7.9% for 9.0 × 10−5 M and 14.1% for 2.0 × 10−4 M, (n = 5). Satisfactory results were obtained for cholesterol determination in serum samples compared to a reference procedure.  相似文献   

2.
Spectrophotometric flow injection methods were developed for the individual determination of nitrite or nitrate, and for the simultaneous determination of nitrite and nitrate, in soil samples. Nitrite was determined directly using a modified version of the Griess-Ilosvay diazo-coupling reaction, measuring at 543 nm the absorbance of the azo-dye complex formed. Simultaneous nitrite and nitrate determinations were based on on-line nitrate reduction in a micro column containing copperised cadmium. A single chromogenic reagent containing all the necessary reactants was used in both methods. For determinations, the chemical and instrumental variables were optimised by univariate analysis and simplex chemometric method. The optimised conditions gave a linear calibration range between 0.05 and 1.6 µg m L− 1 for N-NO2 and between 0.05 and 7.0 µg m L− 1 for N-NO3. The detection limits for nitrite and nitrate were 22 µg L− 1 and 44 µg L− 1 respectively. The proposed methods allowed up to 35-40 samples per hour to be analysed with good precision. The simultaneous method was successfully used for the determination of nitrite and nitrate in soil samples (the results obtained were validated against those obtained by reference methods). The proposed methods are simpler and faster than conventional methods and could be routinely used in environmental monitoring laboratories.  相似文献   

3.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

4.
A capillary zone electrophoresis (CZE) method for separation of adenosine and N6-isopentenyladenosine (cytokinin) nucleotides was developed, optimized and validated. Aqueous solutions of several amino acids were evaluated as the background electrolyte constituents. Separation of six nucleotides in less than 20 min with high theoretical plate number (up to 400 000 for isopentenyladenosine triphosphate) was achieved using a 100 mM sarcosine/ammonia buffer at pH 10.0. The detection limits of the CZE-UV method are in the low micromolar range (0.69–1.27 μmol L−1). Good repeatability of migration times (within 1.3%), peak areas (within 1.8%) and linearity (R2 > 0.999) was achieved over the concentration range 5–1000 μmol L−1. The method was used to assay the activity of the recombinant Arabidopsis thaliana isopentenyltransferase 1 (AtIPT1). Baseline separation of isopentenylated nucleotides by CE–ESI-MS using a volatile buffer (30 mM ammonium formate; pH 10.0) was accomplished. The identities of the reaction products – isopentenyladenosine di- and triphosphate were confirmed by HPLC-QqTOF-MS. Dephosphorylation of ATP was observed as a parallel reaction.  相似文献   

5.
In this work, it was developed a method for the determination of nitrite and nitrate in groundwater by high-resolution continuum source electrothermal molecular absorption spectrometry of NO produced by thermal decomposition of nitrate in a graphite furnace. The NO line at 215.360 nm was used for all analytical measurements and the signal obtained by integrated absorbance of three pixels. A volume of 20 μL of standard solution or groundwater sample was injected into graphite furnace and 5 μL of a 1% (m/v) Ca solution was co-injected as chemical modifier. The pyrolisis and vaporization temperatures established were of 150 and 1300 °C, respectively. Under these conditions, it was observed a difference of thermal stability among the two nitrogen species in the presence of hydrochloric acid co-injected. While that the nitrite signal was totally suppressed, nitrate signal remained nearly stable. This way, nitrogen can be quantified only as nitrate. The addition of hydrogen peroxide provided the oxidation of nitrite to nitrate, which allowed the total quantification of the species and nitrite obtained by difference. A volume of 5 μL of 0.3% (v/v) hydrochloric acid was co-injected for the elimination of nitrite, whereas that hydrogen peroxide in the concentration of 0.75% (v/v) was added to samples or standards for the oxidation of nitrite to nitrate. Analytical curve was established using standard solution of nitrate. The method described has limits of detection and quantification of 0.10 and 0.33 μg mL−1 of nitrogen, respectively. The precision, estimated as relative standard deviation (RSD), was of 7.5 and 3.8% (n = 10) for groundwater samples containing nitrate–N concentrations of 1.9 and 15.2 μg mL−1, respectively. The proposed method was applied to the analysis of 10 groundwater samples and the results were compared with those obtained by ion chromatography method. In all samples analyzed, the concentration of nitrite–N was always below of the limit of quantification of both the methods. The concentrations of nitrate–N varied from 0.58 to 15.5 μg mL−1. No significant difference it was observed between the results obtained by both methods for nitrate–N, at the 95% confidence level.  相似文献   

6.
Zhao Y  Zhao S  Huang J  Ye F 《Talanta》2011,85(5):2650-2654
A sensitive method based on quantum dot (QD)-enhanced capillary electrophoresis-chemiluminescence (CE-CL) detection was developed for simultaneous determination of dopamine (DA) and epinephrine (E). In this work, CdTe QD was added into the running buffer of CE to catalyze the post-column CL reaction between luminol and hydrogen peroxide, achieving higher CL emission. Negative peaks were produced due to the inhibitory effects on CL emission from DA and E eluted from the electrophoretic capillary. The decrease in CL intensity was proportional to the concentration of DA and E in the range of 8.0 × 10−8-5.0 × 10−6 M and 4.0 × 10−8-5.0 × 10−6 M, respectively. Detection limits for DA and E were 2.3 × 10−8 M and 9.3 × 10−9 M, respectively. Using this method, the levels of DA and E in human urine from healthy donors were determined.  相似文献   

7.
A rapid and simple method using capillary electrophoresis (CE) with chemiluminescence (CL) detection was developed for the determination of levodopa. This method was based on enhance effect of levodopa on the CL reaction between luminol and potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in alkaline aqueous solution. CL detection employed a lab-built reaction flow cell and a photon counter. The optimized conditions for the CL detection were 1.0 × 10−5 M luminol added to the CE running buffer and 5.0 × 10−5 M K3[Fe(CN)6] in 0.6 M NaOH solution introduced postcolumn. Under the optimal conditions, a linear range from 5.0 × 10−8 to 2.5 × 10−6 M (r = 9991), and a detection limit of 2.0 × 10−8 M (signal/noise = 3) for levodopa were achieved. The precision (R.S.D.) on peak area (at 5.0 × 10−7 M of levodopa, n = 11) was 4.1%. The applicability of the method for the analysis of pharmaceutical and human plasma samples was examined.  相似文献   

8.
Separation and simultaneous determination of a number of organic acid anions (oxalate, mellitate, trimellitate and benzoate) and U(VI) with direct UV detection is developed for analysis of uranium carbide (UC) dissolution products by capillary zone electrophoresis (CZE). Reverse polarity mode is used. It is found that complex formation of U(VI) with carbonate, used as a carrier electrolyte, allows U(VI) to be determined, as negatively charged species, in a single run with organic acid anions. Some parameters such as pH value, composition of electrolyte and detection wavelength are optimized. Under the chosen conditions (carbonate buffer (ionic strength of 100 mM), pH 9.8, 0.15 mM tetradecyltrimethylammonium bromide (TTAB)) a complete separation is achieved. Calibration plots are linear in two ranges of concentration for U(VI) (∼1 × 10−5 to 1 × 10−3), mellitate and trimellitate (∼5 × 10−6 to 5 × 10−4), and about one range (∼1 × 10−4 to 5 × 10−3) for oxalate and benzoate. Accuracy of the procedure is checked by the “added-found” method in standard mixture solutions. Relative standard deviation is within the range of 2–10% and the recovery is in the range of 90–110%. This method is applied for the analysis of real UC dissolution samples.  相似文献   

9.
A novel integrated chemiluminescence (CL) flow sensor for the determination of adrenaline and isoprenaline is developed based on the enhancing effect of analytes on CL emission of luminol oxidized by periodate in alkaline solution. The analytical reagents luminol and periodate are immobilized on anion exchange resins, respectively, and packed in a glass tube to construct a reagentless sensor. The proposed sensor allows the determination of adrenaline and isoprenaline over the range from 2.0×10−8 to 1.0×10−5 g ml−1 and 2.0×10−7 to 5.0×10−5 g ml−1, respectively. The detection limits are 7.0×10−9 g ml−1 for adrenaline and 5.0×10−8 g ml−1 for isoprenaline with a relative standard deviation of 1.7% for the 1.0×10−7 g ml−1 adrenaline (n=11) and 2.1% for 1.0×10−6 g ml−1 isoprenaline (n=11). The sample throughput was 60 samples h−1. The sensor has been successfully applied to the determination of adrenaline and isoprenaline in pharmaceutical preparations.  相似文献   

10.
A novel Cu-zeolite A/graphene modified glassy carbon electrode for the simultaneous electrochemical determination of dopamine (DA) and ascorbic acid (AA) has been described. The Cu-zeolite A/graphene composites were prepared using Cu2+ functionalized zeolite A and graphene oxide as the precursor, and subsequently reduced by chemical agents. The composites were characterized by X-ray diffraction, Fourier transform infrared spectra and scanning electron microscopy. Based on the Cu-zeolite A/graphene-modified electrode, the potential difference between the oxidation peaks of DA and AA was over 200 mV, which was adequate for the simultaneous electrochemical determination of DA and AA. Also the proposed Cu-zeolite/graphene-modified electrode showed higher electrocatalytic performance than zeolite/graphene electrode or graphene-modified electrode. The electrocatalytic oxidation currents of DA and AA were linearly related to the corresponding concentration in the range of 1.0 × 10−7–1.9 × 10−5 M for DA and 2.0 × 10−5–2.0 × 10−4 M for AA. Detection limits (<!-- no-mfc -->S/N<!-- /no-mfc --> = 3) were estimated to be 4.1 × 10−8 M for DA and 1.1 × 10−5 M for AA, respectively.  相似文献   

11.
Yue XF  Zhang ZQ  Yan HT 《Talanta》2004,62(1):97-101
A new flow injection catalytic spectrophotometric method is proposed for the simultaneous determination of nitrite and nitrate based on the catalytic effect of nitrite on the redox reaction between crystal violet and potassium bromate in phosphoric acid medium and nitrate being on-line reduced to nitrite with a cadmium-coated zinc reduction column. The redox reaction is monitored spectrophotometrically by measuring the decrease in the absorbance of crystal violet at the maximum absorption wavelength of 610 nm. A technique of inserting a reduction column into sampling loop is adopted and the flow injection system produces a signal with a shoulder. The height of shoulder in the ascending part of the peak corresponds to the nitrite concentration and the maximum of the peak corresponds to nitrate plus nitrite. The detection limits are 0.3 ng ml−1 for nitrite and 1.0 ng ml−1 for the nitrate. Up to 32 samples can be analyzed per hour with a relative standard deviation of less than 2%. The method has been successfully applied for the simultaneous determination of nitrite and nitrate in natural waters.  相似文献   

12.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   

13.
Carbon nanoparticles (CNPs) and halloysite nanoclay (HNC) modified carbon paste electrode (HNC–CNP–CPE) was developed for the determination of methyl parathion (MP) and ethyl parathion (EP). The electrochemical behavior of these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and potentiometric stripping analysis (PSA). After optimization of analytical conditions employing this electrode at pH 5.0 in acetate buffer (0.1 M), the peak currents were found to vary linearly with its concentration in the range of 1.55 × 10−9 to 3.67 × 10−6 M and 1.21 × 10−9 to 4.92 × 10−6 M for MP and EP, respectively. The detection limits (S/N = 3) of 4.70 × 10−10 M and 3.67 × 10−10 M were obtained for MP and EP, respectively, using PSA. The prepared modified electrode showed several advantages such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of MP and EP in fruits, vegetables, water and soil samples.  相似文献   

14.
A flow injection (FI) method with flame atomic absorption spectrometry (FAAS) detection was developed for the determination and speciation of nitrite and nitrate in foodstuffs and wastewaters. The method is based on the oxidation of nitrite to nitrate using a manganese(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the MnO2 solid phase reagent to Mn(II), which is measured by FAAS. The absorbance of Mn(II) are proportional to the concentration of nitrite in the samples. The injected sample volume was 400 μL with a sampling rate of analyses was 90 h−1 with a relative standard deviation better than 1.0% in a repeatability study. Nitrate is reduced to nitrite in proposed FI-FAAS system using a copperized cadmium microcolumn and analyzed as nitrite. The calibration curves were linear up to 20 mg L−1 and 30 mg L−1 with a detection limit of 0.07 mg L−1 and 0.14 mg L−1 for nitrite and nitrate, respectively. The results exhibit no interference from the presence of large amounts of ions. The method was successfully applied to the speciation of nitrite and nitrate in spiked natural water, wastewater and foodstuff samples. The precision and accuracy of the proposed method were comparable to those of the reference spectrophotometric method.  相似文献   

15.
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 × 10−7 mol L−1 to 8.3 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 × 10−7 mol L−1 and 3.5 × 10−8 mol L−1, respectively. The proposed method was successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level).  相似文献   

16.
Spermine-graft-dextran (Spe-g-Dex) copolymer was synthesized and used as a non-covalent coating for the separation of proteins and neurotransmitters by capillary electrophoresis. The coating was obtained via flushing the capillary with 1.0% Spe-g-Dex copolymer solution for 2 min. Electroosmotic flow (EOF) was strongly suppressed, ranging from −1.60 × 10−9 to 3.65 × 10−9 m2 V−1 s−1. Effect of experimental conditions, such as the copolymer concentration, the concentration and pH of the background electrolyte (BGE), on the Spe-g-Dex coating was investigated. Separation of lysozyme, cytochrome c, ribonuclease A and α-chymotrypsinogen yielded high separation efficiencies ranging from 141 000 to 303 000 plates/m and recoveries from 85.4% to 98.3% at pH 4.0 (284.0 mM sodium acetate–acetic acid buffer, I = 50 mM). Run-to-run repeatabilities and day-to-day, and capillary-to-capillary reproducibilities were all below 1.7%. In addition, Spe-g-Dex coating allowed the successful separation of five neurotransmitters, 5-hydroxytryptamine, dopamine, epinephrine, isoprenaline, dobuamine at pH 4.0 with high separation efficiencies of 290 000–449 000 plates/m.  相似文献   

17.
Filik H  Giray D  Ceylan B  Apak R 《Talanta》2011,85(4):1818-1824
A novel fiber optic spectrophotometric method for nitrite determination in different samples is suggested, based on the reaction of nitrite with Safranin O in acidic medium to form a diazo-safranin, which is subsequently coupled with pyrogallol in alkaline medium to form a highly stable, red azo dye, followed by cloud point extraction (CPE) using a mixed micelle of a nonionic surfactant, Triton X-114, with an anionic surfactant, sodium dodecyl sulphate (SDS). The reaction and extraction conditions (e.g., acidity for diazotization and alkalinity for pyrogallol coupling, and other reagent concentrations, time, and tolerance to other ions) were optimized. Linearity was obeyed in a concentration range up to 230 μg L−1, and the detection limit of the method is 0.5 μg L−1 of nitrite ion. The molar absorptivity for nitrite of the Safranin-diazonium salt (?610 nm = 4 × 103 L mol−1 cm−1) existing in literature was greatly enhanced by pyrogallol coupling and CPE enrichment (?592 nm = 1.39 × 105 L mol−1 cm−1). The method was applied to the determination of nitrite in tap water, lake water and milk samples with an optimal preconcentration factor of 20.  相似文献   

18.
The simultaneous determination of levodopa (LD) and propranolol (PRO) using fluorescence spectrometric technique is described. The method involves measuring the natural fluorescence of these drugs in the micellar media of sodium dodecyl sulfate (SDS) using principal component analysis-feed-forward neural networks (PC-FFNNs). Experimental conditions such as effect of pH and SDS concentration were optimized. Under the optimum conditions, the linear determination ranges of LD and PRO are 2.0 × 10−8 to 1.0 × 10−5 mol L−1 and 3.6 × 10−9 to 1.8 × 10−6 mol L−1, respectively. A set of synthetic binary mixtures of LD and PRO was prepared and their concentrations were predicted by the proposed method. Satisfactory results were obtained by the combination of fluorescence technique with chemometrics methods. The method was successfully applied to the determination of LD and PRO in tap water and in urine samples.  相似文献   

19.
A method was developed for the analysis of four aliphatic diamines by capillary zone electrophoresis using pre-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA)/CN and amperometric detection. The pre-column derivatization reaction conditions including the molar ratio of NDA to amines, the cyanide concentration, the pH value of derivatization buffer, and the reaction time, were investigated. The separation of four derivatives of aliphatic diamines has been optimized by capillary zone electrophoresis (CZE) using end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.7 V versus SCE. The optimum conditions for the separation were 10 mM Tris-H3PO4 (pH 4.0) for the running buffer solution, 15 kV for the separation voltage. The detection limits for diaminopropane, putrescine, cadaverine, diaminohexane were 6.7×10−8, 5.1×10−8, 1.9×10−7 and 3.8×10−7 M, respectively (S/N=3). The proposed method was applied to the determination of aliphatic diamines in a lake water sample by the standard addition method. The recovery of these amines in water was 89.9-107%.  相似文献   

20.
A fluorometric method for quantity analysis of biothiols was developed using a graphene oxide (GO)-based “molecular beacon”-like probe, which consisted of FITC labeled thymine (T)-rich single-stranded DNA (ssDNA), GO and Hg2+ ions. The labeled ssDNA containing T–T mismatches would self-hybridize to duplex in the presence of Hg2+, which can avoid its adsorption on GO and the fluorescence of this GO-based probe was recovered. The fluorescence of the probe quenched after the addition of biothiols such as glutathione (GSH) and cysteine (Cys) owing to thiol groups can selectively competitive ligation of Hg2+ ions with T–T mismatches. In the present work, the GO-based probe was used for the determination of GSH and Cys. Under the optimal conditions, a linear correlation was established between fluorescence intensity ratio I0/I and the concentration of GSH in the range of 2.0 × 10−9–5.0 × 10−7 mol L−1 with a detection limit of 1.0 × 10−9 mol L−1. The linear range for Cys is from 5.0 × 10−9 to 4.5 × 10−7 mol L−1 with a detection limit of 2.0 × 10−9 mol L−1. The proposed method was applied to the determination of GSH in human serum and cell extract samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号