首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Although nonionic micellar electrokinetic chromatography is used for the separation of charged compounds that are not easily separated by capillary zone electrophoresis, the effect of the hydrophilic moiety of the nonionic surfactant has not been studied well. In this study, the separation of ultraviolet‐absorbing amino acids was studied in electrokinetic chromatography using neutral polyoxyethylene lauryl ether surfactants (Adekatol) in the separation solution. The effect of the polyethylene moiety (the number of repeating units was from 6.5 to 50) of the hydrophobic test amino acids (methionine, tryptophan, and tysorine) was studied using a 10 cm effective length capillary. The separation mechanism was based on hydrophobic as well as hydrogen bonding interactions at the micellar surface, which was made of the polyoxyethylene moiety. The length of the polyoxyethylene moiety of the surfactants was not important in nonionic micellar electrokinetic chromatography mode.  相似文献   

2.
Cao J  Dun WL 《Talanta》2011,84(1):155-159
In this report, a novel means for the separation and sweeping of flavonoids (quercetin, rutin, calycosin, ononin and calycosin-7-O-β-d-glucoside) by microemulsion electrokinetic chromatography using mixed anionic and cationic surfactants as modified pseudostationary phase was presented. The optimized background electrolyte consisted of 0.5% (w/v) ethyl acetate, 2.0% (w/v) SDS, 9 mM DTAC, 4.0% (w/v) 1-butanol and 10 mM sodium borate or 25 mM phosphoric acid. We systematically investigated the separation and preconcentration conditions, including the concentrations of surfactant, types of sweeping, sample matrix, the effect of high salt or acetonitrile, and sample injection volume. It was found that the use of mixed surfactants significantly enhanced the separation efficiency through the change of the efficient electrophoretic mobility of analytes. Compared with normal sample injection, 185-508-fold sensitivity enhancement in terms of limit of detection was achieved through effective sweeping of large sample volume at 50 mbar pressure (up to 45% capillary length). At last, the proposed method was suitable for the determination of Radix Astragali sample.  相似文献   

3.
This study describes for the first time, the ability of a normal stacking mode (NSM) on-line concentration step coupled with water-in-oil (W/O) microemulsion electrokinetic chromatography (MEEKC), using six common penicillin antibiotics (oxacillin, penicillin V, penicillin G, nafcillin, ampicillin, and amoxicillin) as test analytes. Optimization of penicillin separation in the conventional W/O MEEKC system demonstrated that change in the type and concentration of the oil phase (1-butanol) and column temperature had a pronounced effect on the separation. With the subsequent development of the NSM coupled with W/O MEEKC, improved separation and detection sensitivities were observed when an organic solvent plug (1-propanol; 1.04 cm) was placed between the W/O microemulsion and the sample solutions. This could be attributed to the solution viscosity difference between the aqueous sample zone and the organic solvent plug causing the penicillin to be stacked in this 1-propanol plug. The optimal NSM W/O MEEKC provided about 12-fold increase in detection sensitivity compared with conventional sample injection (50 mbar, 3 s). Finally, this proposed method was successfully applied in the analyses of several food samples (porcine organs) spiked with penicillin.  相似文献   

4.
胶束在线扫集毛细管电泳法测定三聚氰胺   总被引:1,自引:0,他引:1  
研究胶束在线扫集毛细管电泳法测定三聚氰胺的可行性,结果表明,与区带毛细管电泳相比,胶束在线扫集毛细管电泳法富集倍数提高约60倍。缓冲体系为140 mmol/L SDS+20 mmol/L NaH2PO4(pH 2.20)+10%(体积分数)甲醇,分离电压-18 kV,进样时间30 s,测量波长214 nm。考察了SDS浓度、pH、进样时间、运行电压等因素对分离测定的影响情况。在优化条件下,三聚氰胺在9 min时出峰,峰面积RSD≤3.7%。方法检出限、线性范围、相关系数分别为:0.13μg/mL、0.50~32.0μg/mL、0.9997。方法可用于奶粉中三聚氰胺的分离测定。  相似文献   

5.
This paper demonstrates in a practical manner the on-column preconcentration of hydrophobic solutes, such as quinine, alkyl phenones, and progesterone, by the sweeping mechanism using polymeric surfactants with highly acidic ionic head groups. The sulfonated and sulfated copolymers used showed high electrophoretic mobilities, high solubility, and good stability in organic/aqueous solutions with low pH values. More than 1000-fold increase in signal was observed for quinine, heptanophenone, and progesterone using sweeping in reversed-flow electrokinetic chromatography at low pH. The detection limit of quinine can be lower than 42 ppb (ng/mL) using a diode array UV detector. Quinine, a cationic hydrophobic solute with a relatively high retention factor, can be concentrated 5800 to 10,000-fold and separated from other hydrophobic solutes using a separation buffer containing a relatively high concentration of organic modifier. Under these conditions, detection of 12.5 ppb of quinine with a signal-to-noise ratio of 15 is achieved. The retention times and peak heights of hydrophobic solutes are shown to be reproducible.  相似文献   

6.
Huang HY  Lien WC 《Electrophoresis》2005,26(16):3134-3140
In this study, a microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect 13 phenolic compounds (syringic acid, p-cumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), which are present in many plant-derived foods. The effects of cosurfactant, organic modifier, and oil were examined in order to optimize the separation of these phenolic compounds. The amounts of cosurfactant (cyclohexanol) and organic modifier (acetonitrile) were determined as the major influence on the separation selectivity, while the type of oil partially affected the separation resolution of the phenolic compounds. A highly efficient MEEKC separation method was achieved within 14 min by using a microemulsion solution of pH 2.0 containing 2.89% w/v SDS, 1.36% w/v heptane, 7.66% w/v cyclohexanol, and 2% w/v ACN. Furthermore, the present work could demonstrate that the nature of the oil phase has a significant influence on the separation selectivity of phenolic compounds.  相似文献   

7.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

8.
A CD‐modified microemulsion electrokinetic chromatography method has been developed and validated for dexamphetamine sulfate which allows the simultaneous determination of charged and uncharged impurities of the drug including the levorotary (R)‐enantiomer. The optimized background electrolyte consisted of 1.5% w/w SDS, 0.5% w/w ethyl acetate, 3.5% w/w 1‐butanol, 2.5% w/w 2‐propanol and 92% w/w 50 mM sodium phosphate buffer, pH 3.0, containing 5.5% w/w sulfated β‐CD. Separations were performed in a 50.2/40 cm, 50 μm id fused silica capillary at a temperature of 20°C and an applied voltage of ?14 kV. Carbamazepine was used as internal standard. The assay was validated in the range of 0.1–1.0% for the related substances and 0.1–5.0% for levoamphetamine based on a concentration of 3 mg/mL of dexamphetamine sulfate. The LOD of all analytes ranged between 0.05 and 0.2%. In commercial samples of dexamphetamine sulfate, levoamphetamine was found at concentrations between 3.2 and 3.8%, whereas none of the other impurities could be detected.  相似文献   

9.
The elution order of the hop α- and β-acids has been studied under different modes of electrokinetic separation. A model is advanced to explain the shorter migration times of the more hydrophobic β-acids compared to the α-acids in micellar electrokinetic chromatography (MEKC). For quality control of the bitter principles in hops, the ruggedness of electrokinetic separation could be improved by replacing MEKC by microemulsion electrokinetic chromatography (MEEKC).  相似文献   

10.
Youyou Yang  Chenchen Li  Ning Li  Huwei Liu 《Talanta》2010,82(5):1797-6510
In this paper, a micellar electrokinetic chromatography (MEKC) method combined with cation-selective exhaustive injection (CSEI) and sweeping was developed to separate and concentrate four tobacco-specific N-nitrosamines (TSNAs) including N′-nitrosoanabasine (NAB), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) and 4-(methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL). Experimental parameters affecting separation efficiency and enhancement factors were investigated in detail. Under the optimum MEKC condition, NAB, NNK, NNAL and iso-NNAL were baseline separated with high separation efficiencies and good peak shapes. Furthermore, with the preconcentration by CSEI-sweeping-MEKC, the sensitivity enhancement factors for NAB, NNK, NNAL and iso-NNAL in terms of peak areas ranged from 6.0 × 103 to 1.5 × 104, and the detection limits (LOD, S/N = 3) of four TSNAs were in the range of 0.004-0.016 μg/mL. In addition, this method had fairly good repeatability, and the RSDs of retention time and peak area were less than 1% and 5%, respectively. Finally, this method showed promising capabilities in the application of detecting and analyzing TSNAs in human urine samples.  相似文献   

11.
In this work, the influences of ionic liquid (IL) as a modifier on microemulsion microstructure and separation performance in MEEKC were investigated. Experimental results showed that synergetic effect between IL 1‐butyl‐3‐methylimidazolium tetrafluoro‐borate (BmimBF4) and surfactant SDS gave a decreased CMC. With increment of IL in microemulsion, negative ζ potential of the microdroplets reduced gradually. The influence of IL on the dimensions of microdroplet was complicated. At BmimBF4 less than 8 mM, IL made microemulsion droplet smaller in size. While at BmimBF4 more than 10 mM, the size increased and reached to a maximum value at 12 mM, where the microdroplets were larger than that without IL. After that, the micreodroplet size decreased again. Relative fluorescence intensity of the first vibration band of pyrene to the third one (I1/I3) enhanced as IL was added to microemulsion, which indicated that this addition increased environmental polarity in the inner core of microdroplets. Prednisone, hydrocortisone, prednisolone, hydrocortisone acetate, cortisone acetate, prednisolone acetate, and triamcinolone acetonide were analyzed with MEEKC modified with IL to evaluate the separation performance. Cortisone acetate and prednisolone acetate could not be separated at all in typical microemulsion. The seven analytes could be separated by the addition of 10 mM BmimBF4 into the microemulsion system. The method has been used for analysis of corticosteroids in cosmetic samples with simple extraction; the recoveries for seven analytes were between 86 and 114%. This method provides accuracy, reproducibility, pretreatment simplicity, and could be applied to the quality control of cosmetics.  相似文献   

12.
建立了微乳液毛细管电动色谱快速测定解热镇痛药中非那西丁、氨基比林和咖啡因的新方法。采用由乙酸乙酯-十二烷基硫酸钠(SDS)-正丁醇-硼砂缓冲液组成的微乳液体系,以氯霉素为内标,3种有效成分在2.5 min内完成分离,峰面积相对标准偏差(RSD)在1.2%~1.6%之间,回收率在95.6%~104.0%之间。实验考察了缓冲溶液的浓度、pH值、SDS浓度以及助表面活性剂的种类、含量对分离测定的影响。该法可用于实际样品分析。  相似文献   

13.
K. D. Altria 《Chromatographia》1999,49(7-8):457-464
Summary Microemulsion Electrokinetic Chromatography (MEEKC) has previously been reported to be useful for the separation of a range of hydrophobic solutes. The previous reports had tended to show relatively long separation times. In this report the separation and operation conditions were optimized and a method was successfully employed in a range of novel applications. High efficiencies, rapid separations and high repeatability were demonstrated. The applications developed included a range of both neutral and charged compounds. Both water-soluble and water-insoluble compounds were also well separated. The novel applications developed included analysis of basic drugs, various aromatic acids, a range of neutral aromatics, profiling of ink components, direct injection of urine for profiling purposes and the analysis of a range of amino acids and their derivatives. The method could also be used for hydrophobicity measurements of the resolved solutes based upon their migration times. This report clearly shows that MEEKC can be widely applied to a range of compounds and is especially useful for complex mixtures containing solutes with varying charge and hydrophobicity.  相似文献   

14.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

15.
A method based on magnetic separation was developed for the extraction of several estrogens (including diethylstilbestrol, estrone and estriol) in water followed by sweeping micellar electrokinetic chromatography (MEKC) analysis with UV detection. Novel magnetic octadecylsilane (ODS) particles were prepared using a silanization method with octadecyl trimethoxysilane as the surface modification reagent of magnetic Fe3O4 particles. Octadecyl trimethoxysilane was covalently immobilized on the magnetic iron oxide particles. The particles were used as the sorbents in the magnetic separation for the extraction of trace amounts of estrogens from water. The extraction condition and efficiency of the particles for the estrogens were investigated. Combining the magnetic ODS particles extraction and sweeping MEKC with UV detection, the estrogens at concentrations as low as ng/mL in water can be detected without interference from other substances in the sample matrix.  相似文献   

16.
Numerous combinations of one-, two-, and three-chiral-component microemulsions have been previously prepared in our group, using N-dodecoxycarbonylvaline (DDCV), 2-hexanol, and ethyl acetate, dibutyl tartrate, or diethyl tartrate. A few results of the various formulations investigated suggested the possible presence of minor impurities in one or more components of the microemulsion. In this study, the purity of the current lots of R- and S-surfactant were measured, as was the subsequent effect of minor impurities on the relevant chromatographic figures of merit (CFOMs) that describe a chiral separation, i.e., efficiency, enantioselectivity, retention, migration window (elution range), and resolution. Two related methods are proposed for correcting enantioselectivities measured in the presence of chiral impurities in the chiral microemulsion.  相似文献   

17.
Microemulsion electrokinetic chromatography (MEEKC) has been developed for fingerprint analysis of resina draconis, a substitute for sanguis draconis in the Chinese market. The microemulsion as the running buffer was made up of 3.3% (w/v) sodium dodecyl sulfate (SDS), 6.6% (w/v) n-butanol, 0.8% (w/v) n-octane, and 10 mmol/L sodium tetraborate buffer (pH 9.2), which was also used as the solvent for ultrasonic extraction of both water- and fat-soluble compounds in the traditional Chinese medicine samples. Four batches of resina draconis obtained from different pharmaceutical factories located in different geographic regions were used to establish the electrophoretic fingerprint. MEEKC was performed using a Beckman PACE/MDQ system equipped with a diode-array detector and with monitoring at 280 nm. The fingerprint of resina draconis comprised 27 common peaks within 100 min. The relative standard deviations of the relative migration time of these common peaks were less than 2.1%. Through repetitive injection of the sample solution six times in 24 h, all relative standard deviations of the migration time and peak area of loureirin A and loureirin B were less than 2.5 and 3.8%, which demonstrated that the method had good stability and reproducibility. The relative peak areas of these common peaks in the electropherograms of four batches of resina draconis were processed with two mathematical methods, the correlation coefficient and the interangle cosine, to valuate the similarity. The values of the similarity degree of all samples were more than 0.91, which showed resina draconis samples from different origins were consistent. On the other hand, high-performance liquid chromatography (HPLC) coupled with photodiode-array detection was also applied to establish the fingerprint of resina draconis. The samples were separated with a LiChrospher C18 column using acetonitrile (solvent A) and water containing 0.1% H3PO4 (solvent B) as the mobile phase in linear gradient elution mode at a flow rate of 0.6 mL/min and detection was at 280 nm. There were only 20 common peaks in the HPLC fingerprint, and the values of the similarity degree of all samples were also more than 0.91. Though the similarity results of fingerprint analysis seemed to be the same, MEEKC resulted in more common peaks and higher separation efficiency for a variety of polarities of the components than HPLC. So, MEEKC was more suitable for development of the fingerprint of resina draconis.  相似文献   

18.
Summary The sweeping concept is extended to capillary zone electrophoresis (CZE) separation of neutral solutes involving complexation with borate. Analogous to the pseudostationary phase in electrokinetic chromatography (EKC), the complexing agent (borate) serves as carrier for sweeping and separation in CZE. Therefore, similar to the retention factor in EKC, the focusing effect in the present system is directly related to the association constant between the analyte and complexing agent. Theoretical and some preliminary experimental studies gerenally suggest that the electrophoretic mobility of the complex and the concentration of the complexing agent affect the resulting length of narrowed zones. Moreover, sweeping using borate is affected by pH since borate complexation is pH dependent. From around 10 to 40-fold improvement in peak heights has been observed experimentally for some neutral test analytes (monosaccharides, catechols, and nucleosides)  相似文献   

19.
采用胶束扫集毛细管电动色谱技术,建立了测定药物中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DZP)和邻苯二甲酸二丁酯(DBP)的方法。电泳缓冲体系含80 mmol/L SDS,20 mmol/L NaH2PO4(pH 2.20),5%甲醇(V/V),分离电压-18 kV,重力进样80s×15.0cm,检测波长225 nm,使用Φ50μm×62.0 cm石英毛细管,有效长度50.0 cm。讨论了磷酸盐浓度、有机改善剂、SDS浓度、分离电压、进样时间等因素的影响,并考察了胶束扫集法对DMP、DEP和DBP的富集能力。在优化条件下,线性关系良好,相关系数大于0.9986,DMP、DEP和DBP的线性范围分别为1.25~240,1.04~200和1.56~200 mg/L,检出限分别为0.26,0.26和0.39 mg/L。方法应用于肠溶片中DMP、DEP和DBP的测定,回收率在93.3%~108%之间,RSD≤5.2%。每次样品测定可在10 min内完成。  相似文献   

20.
In this study, a sample stacking step coupled with microemulsion electrokinetic chromatography (MEEKC) was used to detect and analyze nine aromatic acids (benzoic acid (BA), isophthalic acid (IPA), terephthalic acid (TPA), p-toluic acid (p-TA), 4-carboxylbenzaldehyde (4-CBA), trimesic acid (TSA), trimellitic acid (TMA), o-phthalic acid (OPA), and hemimellitic acid (HMA)) which are common impurities produced during aromatic acid synthesis. First, the presence of both acid and water plugs at the front of the capillary improved the reproducibility in retention time and peak intensity of the tested analytes in the stacking method. Second, the pH and the electrolyte type of acidic plug and sample matrix were found to be the predominant influences on the aromatic acid stacking. The detection limits of these aromatic acids were reduced to the range of 0.00007-0.00032 μg mL−1 by this optimal sample stacking step. This proposed on-line concentration MEEKC method was able to detect trace levels of aromatic acid impurities in commercial aromatic acid products that were not previously possible by the normal MEEKC method. Furthermore, these results in comparison with our previous studies on sample stacking MEEKC method indicated that all acidic species were concentrated by this simple stacking procedure. The sensitivity enhancement, however, was highly dependent on the types of functional groups present in the structures of analytes, and the enhancement was in the order of first the compounds carrying both carboxy and hydroxy groups (e.g. phenolic acid), followed by carboxylic acid compounds (e.g. aromatic acid), and then phenol compounds (e.g. polyphenol).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号