首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An improved analytical method enabling rapid and accurate determination and identification of bisphenol F diglycidyl ether (novolac glycidyl ether 2-ring), novolac glycidyl ether 3-ring, novolac glycidyl ether 4-ring, novolac glycidyl ether 5-ring, novolac glycidyl ether 6-ring, bisphenol A diglycidyl ether, bisphenol A (2,3-dihydroxypropyl) glycidyl ether, bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether, bisphenol A bis(3-chloro-2-hydroxypropyl) ether, and bisphenol A (3-chloro-2-hydroxypropyl) (2,3-dihydroxypropyl) ether in canned food and their contact packaging materials has been developed by using, for the first time, ultra-performance liquid chromatography coupled with tandem mass spectrometry. After comparison of electrospray ionization and atmospheric pressure chemical ionization in positive and negative-ion modes, tandem mass spectrometry with positive electrospray ionization was chosen to carry out selective multiple reaction monitoring analysis of novolac glycidyl ethers, bisphenol A diglycidyl ether, and its derivatives. The analysis time is only 5.5 min per run. Limits of detection varied from 0.01 to 0.20 ng g(-1) for the different target compounds on the basis of a signal-to-noise ratio (S/N) = 3; limits of quantitation were from 0.03 to 0.66 ng g(-1). The relative standard deviation for repeatability was <8.01%. Analytical recovery ranged from 87.60 to 108.93%. This method was successfully applied to twenty samples of canned food and their contact packaging materials for determination of migration of NOGE, BADGE, and their derivatives from can coatings into food.  相似文献   

2.
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid–liquid microextraction coupled GC–MS system. Microextraction efficiency factors have been investigated and optimized: 9 μL 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 °C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 μL of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235–1174, limit of detection of 0.005–0.68 μg/L (S/N = 3) and linearity range of 0.02–300 μg/L have been obtained. A reasonable repeatability (RSD ≤ 10.4%, n = 5) with satisfactory linearity (0.9995 ≥ r2 ≥ 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%.  相似文献   

3.
A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17β-estradiol, 17α-ethynylestradiol, estriol) and eleven progestogens (17β-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) with electrospray ionization. Among three types of extraction tested (C8 SPDE, C18 SPDE and C18 SPE), the most satisfactory result was achieved using C18 SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1 L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5–3.4 ng/L) and excellent linear dynamic range (1.0–50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17α-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.  相似文献   

4.
A simple, selective, sensitive and inexpensive method of hollow fiber-based liquid–liquid–liquid microextraction (HF-LLLME) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV) detection was developed for the determination of four acidic phytohormones (salicylic acid (SA), indole-3-acetic acid (IAA), (±) abscisic acid (ABA) and (±) jasmonic acid (JA)) in natural coconut juice. To the best of our knowledge, this is the first report on the use of liquid phase microextraction (LPME) as a sample pretreatment technique for the simultaneous analysis of several phytohormones. Using phenetole to fill the pores of hollow fiber as the organic phase, 0.1 mol L−1 NaOH solution in the lumen of hollow fiber as the acceptor phase and 1 mol L−1 HCl as the donor phase, a simultaneous preconcentration of four target phytohormones was realized. The acceptor phase was finally withdrawn into the microsyringe and directly injected into HPLC for the separation and quantification of the target phytohormones. The factors affecting the extraction efficiency of four phytohormones by HF-LLLME were optimized with orthogonal design experiment, and the data was analyzed by Statistical Product and Service Solutions (SPSS) software. Under the optimized conditions, the enrichment factors for SA, IAA, ABA and JA were 243, 215, 52 and 48, with the detection limits (S/N = 3) of 4.6, 1.3, 0.9 ng mL−1 and 8.8 μg mL−1, respectively. The relative standard deviations (RSDs, n = 7) were 7.9, 4.9, 6.8% at 50 ng mL−1 level for SA, IAA, ABA and 8.4% at 500 μg mL−1 for JA, respectively. To evaluate the accuracy of the method, the developed method was applied for the simultaneous analysis of several phytohormones in five natural coconut juice samples, and the recoveries for the spiked samples were in the range of 88.3–119.1%.  相似文献   

5.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

6.
A liquid chromatography–tandem mass spectrometry method is proposed for the simultaneous determination of 1,1-dimethylhydrazine, methylhydrazine, N,N-dimethylformamide, 1-methyl-1H-1,2,4-triazole, dimethylguanidine, N-nitrosodimethylamine and 1,1,4,4-tetramethyltetrazene, important rocket fuel pollutants of soils. Chromatographic separation was conducted according to previously published results in an isocratic mode on an analytical column with a Nucleosil-100–5SA sulfo-cation-exchanger. The mobile phase composition was optimised in order to achieve effective separation of all analytes and provide high sensitivity of mass spectrometric detection – an ammonium acetate buffer solution (50 mM, pH 5.4) containing methanol (25%) was used. Detection was performed in the positive electrospray ionisation mode with multiple reaction monitoring (MRM). The parameters of ion source, ion optics, the inlet potentials of the quadrupoles and the collision energy for the detection of the found product ions were optimised. Calibration dependences for all compounds are linear in wide concentration ranges, covering 3–4 orders of magnitude. The detection limits vary from 40 pg mL?1 for dimethylguanidine to 18 ng mL?1 for methylhydrazine. No significant matrix effects were observed in the analysis of acid peaty soil extracts. The method was validated and successfully used to analyse a real soil sample collected at the place of impact of the first stage of a carrier rocket.  相似文献   

7.
A sensitive method was developed for the trace determination of six tetracyclines and ten of their degradation products in influent, effluent, and river waters using liquid chromatography–electrospray tandem mass spectrometry detection, combined with Oasis hydrophilic–lipophilic balance (HLB) cartridge extraction and Oasis mixed-mode strong anion exchange (MAX) cartridge cleanup. Tetracyclines and their products were separated by liquid chromatography in 9.5 min, and the instrument detection limits were generally between 0.03 and 0.1 μg/L except for minocycline (0.5 μg/L). The chromatograms were improved through the MAX cleanup and no apparent matrix effect was found. The recoveries of all the target compounds except for 4-epianhydrochlortetracycline and anhydrochlortetracycline (34–52%) were 75–120% for influent, 61–103% for effluent, and 64–113% for river waters. The method detection limits (MDLs) of the analytes varied in the range of 0.8–17.5 ng/L in all studied matrices. The method was applied for the determination of tetracyclines and their products in a sewage treatment plant (STP) and surface waters in Beijing, China. Oxytetracycline (3.8–72.5 ng/L), tetracycline (1.9–16.5 ng/L), and five products including 4-epitetracycline, 4-epioxytetracycline, isochlortetracycline, anhydrotetracycline, and 4-epianhydrochlortetracycline (5.7–25.3 ng/L) were detected in wastewater, while only oxytetracycline and tetracycline (2.2 and 2.1 ng/L) were detected in surface water samples.  相似文献   

8.
This paper describes an analytical method for four phenolic and salicylanilide anthelmintics authorised for use within the EU (nitroxinil, oxyclozanide, rafoxanide and closantel) in bovine kidney, and the extension of this procedure to include a number of related compounds; ioxynil, niclosamide, salicylanide and 3-trifluoromethyl-4-nitrophenol (TFM). The method comprises a solvent extraction with 1% acetic acid in acetone and clean-up using a mixed-mode anion-exchange solid phase extraction column. Determination is by reversed phase LC–MS/MS. The method was validated to the latest EU requirements (Commission Decision 2002/657/EC) using both spiked and incurred tissues and was subject to second laboratory evaluation.  相似文献   

9.
An in-syringe demulsified dispersive liquid–liquid microextraction (ISD–DLLME) technique was developed using low-density extraction solvents for the highly sensitive determination of the three trace fungicides (azoxystrobin, diethofencarb and pyrimethanil) in water samples by high performance liquid chromatography–mass spectrometry chromatography–diode array detector/electrospray ionisation mass spectrometry. In the proposed technique, a 5-mL syringe was used as an extraction, separation and preconcentration container. The emulsion was obtained after the mixture of toluene (extraction solvent) and methanol (dispersive solvent) was injected into the aqueous bulk of the syringe. The obtained emulsion cleared into two phases without centrifugation, when an aliquot of methanol was introduced as a demulsifier. The separated floating organic extraction solvent was impelled and collected into a pipette tip fitted to the tip of the syringe. Under the optimal conditions, the enrichment factors for azoxystrobin, diethofencarb and pyrimethanil were 239, 200, 195, respectively. The limits of detection, calculated as three times the signal-to-noise ratio (S N−1), were 0.026 μg L−1 for azoxystrobin, 0.071 μg L−1 for diethofencarb and 0.040 μg L−1 for pyrimethanil. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 0.02 μg mL−1 for all the three fungicides. The relative standard deviations varied between 4.9 and 8.2% (n = 5). The recoveries of all the three fungicides from tap, lake and rain water samples at spiking levels of 0.2, 1, 5 μg L−1 were in the range of 90.0–105.0%, 86.0–114.0% and 88.6–110.0%, respectively. The proposed ISD–DLLME technique was demonstrated to be simple, practical and efficient for the determination of different kinds of fungicide residues in real water samples.  相似文献   

10.
11.
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 μl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01–0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.  相似文献   

12.
Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography–ESI-mass spectrometry (LC–ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20–6 ng injected), quantitation (excellent linearity; <2% relative standard deviation), and recovery (99–103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.Electronic Supplementary Material Supplementary material is available for this article at  相似文献   

13.
Rifampicin is a semi-synthetic broad-spectrum antibiotic obtained from rifamycin B. It is one of the most effective first-line antituberculosis drugs and is widely used in clinical practice. In the present study, we describe a rapid and sensitive method for the determination of rifampin in aquatic products by stable isotope-dilution high liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). Samples were extracted with the acetonitrile, degreased by hexane, and then concentrated by nitrogen blowing. After separation using a C18 column with a mixture of acetonitrile and water as mobile phase, it was determined by HPLC–MS/MS using the stable isotope-dilution calibration method. The performance of our method was validated. The limit of detection was 0.25 μg kg−1 and the limit of quantification was 0.5 μg kg−1. At the three spiked levels of 0.5, 1.0 and 5.0 μg kg−1, the average recoveries of rifampicin in different aquatic products were between 75.28 and 107.6%, and the relative standard deviation ranged from 0.81 to 13.23%. This method was successfully applied for the determination of rifampin in different kinds of aquatic products and rifampicin residue was found in aquatic products obtained from markets in Beijing, China.  相似文献   

14.
A hydrophilic interaction liquid chromatographic–tandem mass spectrometric (HILIC–MS–MS) method for investigation of the in vivo metabolism of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a potent carcinogen, in rabbit blood has been developed and validated. This method achieved excellent repeatability and accuracy. Recovery ranged from 76.9 to 116.3 % and precision (as RSD) between 0.53 and 6.52 %. Linearity was good for all compounds (R 2?>?0.9990) and the limit of detection (LOD) ranged from 0.016 to 0.082 ng mL?1. Pharmacokinetic analysis indicated that NNK was rapidly eliminated in vivo in rabbit blood and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) was the major metabolite. The hydroxy acid, keto acid, and NNAL-N-oxide were also important metabolites in rabbit blood. It is probable that α-methylene hydroxylation was the major pathway of α-hydroxylation of NNK and NNAL in the rabbit.
Figure
The process of the experiment in this study. NNK solution was injected into rabbit body. Blood samples were obtained and processed, and then transferred into vials. NNK and its metabolites were separated by HILIC column. The ion source of MS is ESI and MRM mode was employed for monitoring ion pairs. The chromatogram of NNK and its metabolites was obtained.  相似文献   

15.
A method using high performance liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) in positive ion mode was developed for the simultaneous analysis of 30 phenolic compounds, including four estrogens, bisphenol A (BPA), 10 hydroxylated polybrominated dephenyl ethers (OH-PBDEs) and 15 bromophenols (BRPs), in blood plasma. In the present method, derivatization with dansyl chloride was employed, and all the derivertized target compounds were well resolved on a 100 mm Xbridge C18 column with acetonitrile and 0.1% formic acid as the mobile phases. Purification procedures, such as liquid–liquid extraction and silica-gel chromatography, were applied to reduce matrix effects in the sample extract and remove excess derivatizing reagents, thus permitting selective and sensitive detection of the target phenolic compounds. The limit of quantification for all analytes, with a signal-to-noise ratio of ∼10, was 2–30 pg/g (plasma weight) except for 6-OH-BDE-137 (30 pg/g) and 3-BRP (60 pg/g). The method was validated for recoveries (68–100%), accuracy (84–110%) and precision (3.7–11%) using charcoal-stripped bovine blood plasma spiked with all target compounds (500 and 5000 pg/mL). Finally, the method was applied to analyze six blood plasma samples from frogs and cormorants, where two natural estrogens, one BPA, one OH-PBDE and four BRPs were detected. The greatest total concentrations of estrogens coincided with the least total concentrations of other phenolic compounds for both species. The proposed method based on derivatization followed by LC–MS/MS provides a novel method to simultaneously monitor multiple groups of phenolic compounds in blood plasma.  相似文献   

16.
An improved selectivity method for the simultaneous determination of four benzotriazoles (benzotriazole, 4-methylbenzotriazole, 5-methylbenzotriazole, and 5,6-dimethyl-1H-benzotriazole) and six benzothiazoles (benzothiazole, 2-hydroxybenzothiazole, 2-benzothiazolamine, mercaptobenzothiazole, 2-methylbenzothiazole, and 2-methylthiobenzothiazole) in aqueous matrices has been developed. Under optimal conditions, analytes are concentrated using a MAX solid-phase extraction (SPE) cartridge, based on divinylbenzene-N-vinylpyrrolidone functionalized with quaternary amine groups, which allows reversed-phase interactions in combination with ionic exchange. Selected compounds are recovered with methanol–acetone 7:3 (v/v) whereas acidic interferences remained attached to the sorbent, and as determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), LOQs for surface, urban and industrial wastewater are in the range of 0.002–0.29 ng/mL. Figures of merit of the method revealed good precision (RSD% <12%), linearity (R 2 > 0.99) and accuracy (%R = 80–100%) for surface waters and effluents allowing direct external standard quantification. For more complex samples, such as urban and industrial raw wastewater, either the standard addition method or pseudo-external standard calibration using matrix matched standards are recommended. Analysis of different real samples, surface, urban wastewater and, for the first time, metal industry wastewater, reflected concentrations up to 310 ng/mL. The methylbenzotriazole isomers ratio was also determined.  相似文献   

17.
A simple and cost effective sample pre-treatment method, dispersive liquid–liquid microextraction (DLLME), has been developed for the extraction of six fluoroquinolones (FQs) from chicken liver samples. Clean DLLME extracts were analyzed for fluoroquinolones using liquid chromatography with diode array detection (LC-DAD). Parameters such as type and volume of disperser solvent, type and volume of extraction solvent, concentration and composition of phosphoric acid in the disperser solvent and pH were optimized. Linearity in the concentration range of 30–500 μg kg−1 was obtained with regression coefficients ranging from 0.9945 to 0.9974. Intra-day repeatability expressed as % RSD was between 4 and 7%. The recoveries determined in spiked blank chicken livers at three concentration levels (i.e. 50, 100 and 300 μg kg−1) ranged from 83 to 102%. LODs were between 5 and 19 μg kg−1 while LOQs ranged between 23 and 62 μg kg−1. All of the eight chicken liver samples obtained from the local supermarkets were found to contain at least one type of fluoroquinolone with enrofloxacin being the most commonly detected. Only one sample had four fluoroquinolone antibiotics (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin). Norfloxacin which is unlicensed for use in South Africa was also detected in three of the eight chicken liver samples analyzed. The concentration levels of all FQs antibiotics in eight samples ranged from 8.8 to 35.3 μg kg−1, values which are lower than the South African stipulated maximum residue limits (MRL).  相似文献   

18.
19.
An in-line matrix cleanup method was used for the simultaneous extraction of 15 sulfonamides and two metabolites from manure samples. The ultrasound/microwave-assisted extraction (UMAE) combined with solid–liquid–solid dispersive extraction (SLSDE) procedure provides a simple sample preparation approach for the processing of manure samples, in which the extraction and cleanup are integrated into one step. Ultrasonic irradiation power, extraction temperature, extraction time, and extraction solvent, which could influence the UMAE efficiency, were investigated. C18 was used as the adsorbent to reduce the effects of interfering components during the extraction procedure. The extracts were concentrated, and the analytes were analyzed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) without any further cleanup. The isotopically labeled compounds sulfamethoxazole-d 4, sulfamethazine-d 4, sulfamonomethoxine-d 4, and sulfadimethoxine-d 6 were selected as internal standards to minimize the matrix effect in this method. The recoveries of the antibiotics tested ranged from 71 to 118 % at the three spiking levels examined (20, 200, and 500 μg?·?kg-1). The limits of detections were 1.2–3.6 μg?·?kg-1 and the limits of quantification were 4.0–12.3 μg?·?kg-1 for the sulfonamides and their metabolites. The applicability of the method was demonstrated by analyzing 30 commercial manure samples. The results indicated that UMAE–SLSDE combined with LC–MS/MS is a simple, rapid, and environmentally friendly method for the analysis of sulfonamides and their metabolites in manure, and it could provide the basis for a risk assessment of the antibiotics in agricultural environments.  相似文献   

20.
A simple, fast and high-throughput LC–tandem mass spectrometry method was developed and validated to simultaneously measure liraglutide and insulin degludec in rat plasma. After protein precipitation, plasma samples were subjected to gradient elution using an InertSustain Bio C18 column with 1000/20/1 water/acetonitrile/formic acid (v/v/v) and 1000/1 acetonitrile/formic acid (v/v) as the mobile phase. The method was validated from 1.00 to 500 ng/mL of liraglutide and insulin degludec. Further, the extraction recovery from the plasma was 41.8%–49.2% for liraglutide and 56.5%–69.7% for insulin degludec. Intra- and inter-day precision of liraglutide was 3.5%–9.4% and 8.4%–9.8%, respectively, whereas its accuracy was between −12.6% and −1.3%. Intra- and inter-day precision of insulin degludec was 5.2%–13.6% and 11.8%–19.1%, respectively, showing an accuracy between −3.0% and 9.9%. As a result, the method was successfully applied to a pharmacokinetics study of liraglutide and insulin degludec following a single-dose subcutaneous administration to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号