首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two different monoliths, both containing phosphoric acid functional groups and polyethylene glycol (PEG) functionalities were synthesized for cation-exchange chromatography of peptides and proteins. Phosphoric acid 2-hydroxyethyl methacrylate (PAHEMA) and bis[2-(methacryloyloxy)ethyl] phosphate (BMEP) were reacted with polyethylene glycol diacrylate (PEGDA) and polyethylene glycol acrylate (PEGA), respectively, in 75-μm i.d. UV-transparent fused-silica capillaries by photo-initiated polymerization. The hydrophobicities of the monoliths were evaluated using propyl paraben under reversed-phase conditions and synthetic peptides under ion-exchange conditions. The resulting monoliths exhibited lower hydrophobicities than strong cation-exchange monoliths previously reported using PEGDA as cross-linker. Dynamic binding capacities of 31.2 and 269 mg/mL were measured for the PAHEMA–PEGDA and BMEP–PEGA monoliths, respectively. Synthetic peptides were eluted from both monoliths in 15 min without addition of acetonitrile to the mobile phase. Peak capacities of 50 and 31 were measured for peptides and proteins, respectively, using a PAHEMA–PEGDA monolith. The BMEP–PEGA monolith showed negligible hydrophobicity. A peak capacity of 31 was measured for the BMEP–PEGA monolith when a 20-min salt gradient rate was used to separate proteins. The effects of functional group concentration, mobile phase pH, salt gradient rate, and hydrophobicity on the retention of analytes were investigated. Good run-to-run [relative standard deviation (RSD) < 1.99%] and column-to-column (RSD < 5.64) reproducibilities were achieved. The performance of the monoliths in ion-exchange separation of peptides and proteins was superior to other polymeric monolithic columns reported previously when organic solvents were not added to the mobile phase.  相似文献   

2.
Rigid monoliths were synthesized solely from poly(ethylene glycol) diacrylates (PEGDA) or poly(ethylene glycol) dimethacrylates (PEGDMA) containing different ethylene glycol chain lengths by one-step UV-initiated polymerization. Methanol/ethyl ether and cyclohexanol/decanol were used as bi-porogen mixtures for the PEGDA and PEGDMA monoliths, respectively. Effects of PEG chain length, bi-porogen ratio and reaction temperature on monolith morphology and back pressure were investigated. For tri- and tetra-ethylene glycol diacrylates (i.e., PEGDA 258 and PEGDA 302), most combinations of methanol and ethyl ether were effective in forming monoliths, while for diacrylates containing longer chain lengths (i.e., PEGDA 575 and PEGDA 700), polymerization became more sensitive to the bi-porogen ratio. A similar tendency was also observed for PEGDMA monomers. Polymerization of monoliths was conducted at approximately 0 °C and room temperature, which produced significant differences in monolith morphology and permeability. Monoliths prepared from PEGDA 258 were found to provide the best chromatographic performance with respect to peak capacity and resolution in hydrophobic interaction chromatography (HIC). Detailed study of these monoliths demonstrated that chromatographic performance was not affected by changing the ratios of the two porogens, but resulted in almost identical retention times and comparable peak capacities. An optimized PEGDA 258 monolithic column was able to separate proteins using a 20-min elution gradient with a peak capacity of 62. Mass recoveries for test proteins were found to be greater than 90, indicating its excellent biocompatibility. All monoliths demonstrated nearly no swelling or shrinking in different polarity solvents, and most of them could be stored dry, indicating excellent stability due to their highly crosslinked networks. The preparation of these in situ polymerized single-monomer monolithic columns was highly reproducible. The relative standard deviation (RSD) values based on retention times of retained proteins were all within 2.2%, and in most cases, less than 1.2%. The RSD values based on peak areas were within 9.5%, and in most cases, less than 7.0%. The single-monomer synthesis approach clearly improves column-to-column reproducibility.  相似文献   

3.
Poly(glycidyl methacrylate-co-ethylene methacrylate) monoliths have been prepared in 100 μm i.d. capillaries and their epoxy groups hydrolyzed to obtain poly(2,3-dihydroxypropyl methacrylate-co-ethylene methacrylate) matrix. These polymers were then photografted in a single step with 2-acrylamido-2-methyl-1-propanesulfonic acid and acrylic acid to afford stationary phases for a strong and a weak cation exchange chromatography, respectively. Alternatively, poly(ethylene glycol) methacrylate was used for grafting in the first step in order to enhance hydrophilicity of the support followed by photografting with 2-acrylamido-2-methyl-1-propanesulfonic acid or acrylic acid in the second step. These new columns were used for the separation of proteins and peptides. A mixture of ovalbumin, α-chymotrypsinogen, cytochrome c, ribonuclease A and lysozyme was used to assess the chromatographic performance for large molecules while a cytochrome c digest served as a model mixture of peptides. All tested columns featured excellent mass transfer as demonstrated with very steep breakthrough curves. The highest binding capacities were found for columns prepared using the two step functionalization. Columns with sulfonic acid functionalities adsorbed up to 21.5 mg/mL lysozyme while the capacity of the weak cation exchange column functionalized with acrylic acid was 29.2 mg/mL.  相似文献   

4.
Sponge-like material was utilized as novel chromatographic media for high throughput analyses. The pore size of the sponge-like material was several dozen micrometer, and was named spongy monolith because it consists of continuous structured copolymers, which was made of poly(ethylene-co-vinyl acetate), such as monolithic materials including silica monoliths and organic polymer monoliths. The spongy monolith was packed into a stainless steel column (100 mm × 4.6 mm I.D.) and evaluated in liquid chromatography (LC) with an on-line column-switching LC concentration system. The results indicate that the packed column could be used with high flow rates and low back pressure (9.0 mL/min at 0.5 MPa). Furthermore, bisphenol A was quantitatively recovered by on-line column-switching LC concentration with the spongy monolithic column. Additionally, the adsorption capacity and physical strength of the media was enhanced via chemical modification of spongy monoliths using glycerol dimethacrylate. The results compared with original spongy monolith demonstrated that a higher adsorption capacity was achieved on a shorter column, and a stable low back pressure was obtained at high throughput elution even with a longer column.  相似文献   

5.
A simple capillary flow porometer (CFP) was assembled for through-pore structure characterization of monolithic capillary liquid chromatography columns in their original chromatographic forms. Determination of differential pressures and flow rates through dry and wet short capillary segments provided necessary information to determine the mean diameters and size distributions of the through-pores. The mean through-pore diameters of three capillary columns packed with 3, 5, and 7 μm spherical silica particles were determined to be 0.5, 1.0 and 1.4 μm, with distributions ranging from 0.1 to 0.7, 0.3 to 1.1 and 0.4 to 2.6 μm, respectively. Similarly, the mean through-pore diameters and size distributions of silica monoliths fabricated via phase separation by polymerization of tetramethoxysilane (TMOS) in the presence of poly(ethylene glycol) (PEG) verified that a greater number of through-pores with small diameters were prepared in columns with higher PEG content in the prepolymer mixture. The CFP system was also used to study the effects of column inner diameter and length on through-pore properties of polymeric monolithic columns. Typical monoliths based on butyl methacrylate (BMA) and poly(ethylene glycol) diacrylate (PEGDA) in capillary columns with different inner diameters (i.e., 50–250 μm) and lengths (i.e., 1.5–3.0 cm) were characterized. The results indicate that varying the inner diameter and/or the length of the column had little effect on the through-pore properties. Therefore, the through-pores are highly interconnected and their determination by CFP is independent of capillary length.  相似文献   

6.
A polar and neutral polymethacrylate-based monolithic column was evaluated as a hydrophilic interaction capillary electrochromatography (HI-CEC) stationary phase with small polar–neutral or charged solutes. The polar sites on the surface of the monolithic solid phase responsible for hydrophilic interactions were provided from the hydroxy and ester groups on the surface of the monolithic stationary phase. These polar functionalities also attract ions from the mobile phase and impart the monolithic solid phase with a given zeta potential to generate electro-osmotic flow (EOF). The monolith was prepared by in situ copolymerization of a neutral monomer 2-hydroxyethyl methacrylate (HEMA) and a polar cross-linker with hydroxy group, pentaerythritol triacrylate (PETA), in the presence of a binary porogenic solvent consisting cyclohexanol and dodecanol. A typical HI-CEC mechanism was observed on the neutral polar stationary phase for both neutral and charged analytes. The composition of the polymerization mixture was systematically altered and optimized by altering the amount of HEMA in the polymerization solution as well as the composition of the porogenic solvent. The monoliths were tested in the pCEC mode. The resulting monoliths had different characteristics of hydrophilicity, column permeability, and efficiency. The effects of pH, salt concentration, and organic solvent content on the EOF velocity and the separation of nucleic acids and nucleosides on the optimized monolithic column were investigated. The optimized monolithic column resulted in good separation and with greater than 140,000 theoretical plates/m for pCEC.  相似文献   

7.
Li Y  Xie X  Lee ML  Chen J 《Journal of chromatography. A》2011,1218(48):8608-8616
Hydrophilic C18 monolithic polymer sorbents were synthesized for use in solid phase extraction (SPE) and in capillary liquid chromatography (LC). The approach involved incorporating both hydrophobic and hydrophilic monomers into a monolithic material, by copolymerization of stearyl methacrylate (SMA), poly(ethylene glycol) methyl ether methacrylate (PEGMEMA) and ethylene dimethacrylate (EDMA) in the presence of selected porogens, to produce translucent mesoporous monolithic materials in bulk (SPE) or white macroporous monoliths inside fused silica capillary columns (capillary LC). A capillary column containing one of the hydrophilic C18 monoliths (i.e. poly(SMA-co-PEGMEMA-co-EDMA) with 15% (w/w) PEGMEMA) demonstrated nearly 35% reduction in retention of polycyclic aromatic compounds and greater than 40% increase in retention of phenols compared to a hydrophobic C18 monolithic column. In addition, the hydrophilic monolith demonstrated significantly improved resolution of phenols. Similar monolithic materials prepared in bulk were ground and sieved to obtain 45-65 μm particles with desired rigidity for SPE. To achieve optimum extraction performance for phenols, several parameters, including sample pH and volume, and eluent type and volume, were investigated. Under optimized experimental conditions, the method demonstrated good sensitivity (1.6 ng/mL LOD) and linearity (R(2)>0.97 for 10-200 ng/mL). Again, incorporation of 15% (w/w) PEGMEMA in the monolith increased the extraction efficiency of phenols in water from approximately 20% to 67-92% compared to a hydrophobic C18 monolithic material. Increased wettability of the sorbent by the aqueous sample matrix and the presence of hydrogen-bonding interactions are responsible for the improved retention of polar compounds.  相似文献   

8.
In this paper, we report on the preparation of a microbore-scale (1 mm i.d.) anion-exchange monolithic column suitable not only for analytical purposes but also for potentially preparative applications. In order to meet the conflicting requirements of high permeability and good mechanical strength, the following two-step procedure was applied. First, an epoxy-containing monolith was synthesized by in situ copolymerization of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) within the confines of a silicosteel tubing of 1.02 mm i.d. and 1/16″ o.d. in the presence of a ternary porogenic mixture of 1-propanol, 1,4-butanediol, and water. The monolithic matrix was subsequently converted into weak anion-exchanger via the ring-opening reaction of epoxy group with diethyl amine. The dynamic binding capacity was 21.4 mg mL−1 for bovine serum albumin (BSA) at 10% breakthrough. The morphology and porous structure of this monolith were assessed by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC). To optimize the separation efficiency, the effects of various chromatographic parameters upon the separation of DNA fragments were investigated. The resulting monolithic anion exchanger demonstrated good potential for the separation of both single- and double-stranded DNA molecules using a gradient elution with NaCl in Tris–HCl buffer (20 mM). Oligodeoxythymidylic acids (dT12–dT18) were successfully resolved at pH 8, while the fragments of 20 bp DNA ladder, 100 bp DNA ladder, and pBR322-HaeIII digest were efficiently separated at pH 9.  相似文献   

9.
Monoliths were prepared in 530 μm I.D. fused silica capillaries via in situ copolymerization of stearyl methacrylate (SMA) with a dimethacrylate cross-linker in the presence of a binary porogenic solvent containing tert  .-butanol and 1,4-butanediol. Alkyl dimethacrylate cross-linkers other than the monomer were used to tune the monolith properties, and, as a result, an increase in the hydrophobicity of the final monoliths (the methylene selectivity αCH2αCH2 increased from 1.396 to 1.475) was observed through an increase in the molecular chain length between two methacrylate units from the 0.360 nm of ethylene glycol dimethacrylate to the 1.241 nm of 1.9-nonanediol dimethacrylate. Moreover, the hydrophobicity of the final monoliths was also greatly affected by the methyl group branch in the cross-linkers, among which the 2-methyl-1,8-octanediol dimethacrylate (2-Me-1,8-ODDMA) mediated monolith exhibited the highest hydrophobicity (αCH2αCH2 was 1.482) and fastest mass transfer kinetics (C-term was 9.14 ms). Besides the effective separation of six model proteins, the poly(SMA-co-2-Me-1,8-ODDMA) monolith also showed an improved performance in the separation of alkylbenzenes. The theoretical plate numbers reached 83 000 plates/m and 52 000 plates/m for thiourea (nonretained compound) and butylbenzene (retained compound), respectively, when using acetonitrile–water (70:30, v/v) as the mobile phase at a typical linear velocity of 1 mm/s. This improved performance towards small molecules was attributed to an increased mesopore proportion in the monolith and the faster dynamic process of mass transfer arising from novel tailoring of the monolith by choosing a suitable monomer/cross-linker pair.  相似文献   

10.
A novel porous polymer monolith was prepared in situ in a fused-silica capillary using photoinitiated polymerization. Bisphenol A dimethacrylate (BPADMA) was selected as a crosslinker, copolymerized with benzyl methacrylate (BMA) in the presence of a binary porogenic solvent consisting of cyclohexanol and 1-decanol in ≤10 min. The resulting poly(BMA-co-BPADMA) monoliths exhibited good permeability and mechanical stability. Mixtures of alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs) or phenolic compounds were successfully separated by CEC. A similar monolith was also prepared with ethylene dimethacrylate (EDMA) as the crosslinker instead of BPADMA to compare the separation ability of the resulting monoliths. The results indicated that poly(BMA-co-BPADMA) monoliths have better selectivity for aromatic analytes and greater chromatographic stability in higher aqueous mobile phase.  相似文献   

11.
Derivatized β‐cyclodextrin (β‐CD) functionalized monolithic columns were prepared by a “one‐step” strategy using click chemistry. First, the intended derivatized β‐CD monomers were synthesized by a click reaction between propargyl methacrylate and mono‐6‐azido‐β‐CD and then sulfonation or methylation was carried out. Finally, monolithic columns were prepared through a one‐step in situ copolymerization of the derivatized β‐CD monomer and ethylene glycol dimethacrylate. The sulfated β‐CD‐based monolith was successfully applied to the hydrophilic interaction liquid chromatography separation of nucleosides and small peptides, while the methylated β‐CD‐functionalized monolith was useful for the separation of nonpolar compounds and drug enantiomers in capillary reversed‐phase liquid chromatography. The structures of the monomers were characterized by Fourier transform infrared spectroscopy and mass spectrometry. The physicochemical properties and column performance of monoliths were evaluated by scanning electron microscopy and micro high performance liquid chromatography. This strategy has considerable prospects for the preparation of other derivatized CD‐functionalized methacrylate monoliths.  相似文献   

12.
Several monolithic macroporous polymer sorbents (pore size 1–2 µm) based on alkyl methacrylates and ethylene glycol dimethacrylate as a cross-linking agent were prepared by free radical copolymerization in columns 3×150 mm. The influence of compositions of the reaction mixture and porogens and the nature of the alkyl radical in a mixture of monomers on the hydrodynamic and chromatographic characteristics of the monoliths was studied. The monoliths based on n-butyl methacrylate have rigid macroporous morphology and excellent hydrodynamic characteristics (flow rate up to 5 mL min?1). The efficiency of separation of a mixture of benzene and its derivatives in the version of reversed-phase HPLC was shown to increase with an increase in the fraction of a lauryl methacrylate additive (LMA) in the reaction mixture. The maximum separation efficiency (number of theoretical plates (tp)) was 35 000 tp m?1 for the monolith based on n-butyl methacrylate with 7% LMA in the reaction mixture.  相似文献   

13.
In this study, high-efficiency LC–MS/MS separations of complex proteolytic digests are demonstrated using 50 mm, 250 mm, and 1 m long poly(styrene-co-divinylbenzene) monolithic capillary columns. The chromatographic performance of the 50 and 250 mm monoliths was compared at the same gradient steepness for gradient durations between 5 and 150 min. The maximum peak capacity of 400 obtained with a 50 mm column, increased to 485 when using the 250 mm long column and scaling the gradient duration according column length. With a 5-fold increase in column length only a 20% increase in peak capacity was observed, which could be explained by the larger macropore size of the 250 mm long monolith. When taking into account the total analysis time, including the dwell time, gradient time and column equilibration time, the 50 mm long monolith yielded better peptide separations than the 250 mm long monolithic column for gradient times below 80 min (nc = 370). For more demanding separation the 250 mm long monolith provided the highest peak production rate and consequently higher sequence coverage. For the analysis of a proteolytic digest of Escherichia coli proteins a monolithic capillary column of 1 m in length was used, yielding a peak capacity of 1038 when applying a 600 min gradient.  相似文献   

14.
Xin P  Shen Y  Qi L  Yang G  Chen Y 《Talanta》2011,85(2):1180-1186
A novel type of poly(N-isopropylacrylamide) grafted E-51 epoxy-based monoliths in a 100 mm × 4.6 mm I.D. stainless steel column with well-controlled three-dimensional skeletal structures has been prepared and proposed for the separation of proteins. The grafted PNIPAAm chain via surface-initiated atom transfer radical polymerization was successfully performed. The proposed method provided a new route to modify the E-51 epoxy-based monoliths for widening their applications. Meanwhile, the temperature and the salt concentration responses of the grafted monolithic columns were investigated. Under the salt gradient, six proteins were well separated in hydrophobic interaction mode. Moreover, for further confirming the application of the prepared monolith was meaningful for proteome analysis in actual system, the separation of human serum sample was performed.  相似文献   

15.
A novel construction strategy of monolithic capillary column for selectively enriching perfluorinated persistent organic pollutants was proposed. The organic–inorganic hybrid fluorous monolithic capillary column was synthesized by a “one‐pot” approach via the polycondensation of γ‐methacryloxypropyltrimethoxy‐silane, then in situ copolymerization of 1H,1H,7H‐dodecafluoroheptyl methacrylate and vinyl group on the precondensed siloxanes. The obtained monolithic columns were systematically characterized. The results demonstrated that the optimal column possessed good mechanical stability and high permeability. The adsorption capacities of the optimized monolithic column for perfluorooctanoic acid and perfluorooctane sulfonate were 0.257 and 0.513 μg/mg, respectively. Adsorption capacities of the monoliths were proved to increasing with increasing the amounts of fluorinated monomers in the fluorous monoliths. Sodium 1‐octanesulfonate, as a comparison compound, was hardly adsorbed on the fluorous monolith. In addition, the trace amounts of perfluorooctanoic acid and perfluorooctane sulfonate in water samples can be successfully concentrated about 160 times to their original concentrations by this monolithic column. These results demonstrated that the capacity and selectivity of the affinity fluorous column is high and can be applied to the selective enrichment for the perfluorinated persistent organic pollutants from environmental samples.  相似文献   

16.
Yang C  Wei Y  Zhang Q  Zhang W  Li T  Hu H  Zhang Y 《Talanta》2005,66(2):472-478
In this study, a 38 mL monolith with homogeneous porous structure was produced by a single polymerization from glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of porogens and an initiator. The uniform temperature distribution within the reaction system was achieved by adding reactant mixture continuously and enhancing the heat transfer ability of the polymerization system. Homogeneous porous structure in the monolith was proved by SEM and the pore size distribution profiles measured by mercury intrusion porosimetry. Experimental results from proteins separation indicated that the dynamic capacity and resolution of radial flow monolithic column were independent of flow rates. Furthermore, the pressure drop on the column was linearly dependent on the flow rate and did not exceed 1.7 MPa even at a flow rate of 50 mL/min, which proved that the prepared monolith could be used in the quick separation and preparation of biopolymers.  相似文献   

17.
A phenylboronic acid-silica hybrid monolithic column for capillary liquid chromatography (cLC) was prepared through one-pot process by using 4-vinylphenylboronic acid (VPBA) and alkoxysilanes simultaneously. The effects of the molar ratio of tetramethyloxysilane/γ-methacryloxypropyltrimethoxysilane (TMOS/γ-MAPS), amount of VPBA, and the volume of diethylene glycol (DEG) on the morphologies, permeabilities and pore properties of the prepared VPBA-silica hybrid monolithic columns were studied in detail. A relatively uniform monolithic structure with high porosity was obtained with optimized ingredients. A series of cis-diol-containing compounds, alkylbenzenes, amides, and anilines were utilized to evaluate the retention behaviors of the VPBA-silica hybrid monolithic column. The result demonstrated that the prepared VPBA-silica hybrid monolithic column exhibited multiple interactions including hydrophobicity, hydrophilicity, as well as cation exchange apart from the expected affinity interaction. The run-to-run, column-to-column and batch-to-batch reproducibility of the VPBA-silica hybrid monolith were satisfactory with the relative standard deviations (RSDs) less than 1.63% (n = 5), 2.02% (n = 3) and 2.90% (n = 5), respectively, indicating the effectiveness and practicability of the proposed method. In addition, the VPBA-silica hybrid monolithic column was further applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA), respectively. The successful applications suggested the potential of the VPBA-silica hybrid monolith in proteome analysis.  相似文献   

18.
The objective of this article was to investigate the feasibility of epoxy resin-based monoliths prepared by stepwise polymerization and column preconcentration of metal ions using large-scale monolithic matrix. A novel macroporous polymer monolith matrix was prepared from epoxy resin (EP) and ethylenediamine (EDA) and pore-forming reagent (polyethylene glycol, PEG-1000) by in situ step-addition polymerization. The morphology of the resulting polymer monolith was characterized by scanning electron microscopy (SEM). A solid-phase extraction (SPE) cartridge prepared from a simple glass-tube was used for the preconcentration and determination of Pb(II) combined with flame atomic absorption spectroscopy (FAAS). The characteristics of the monoliths for the extraction of Pb(II) in aqueous solution were investigated. The experimental results showed that trace Pb(II) ions could be quantitatively preconcentrated in the pH range of 4.0-9.0 with recoveries of >95%. The maximum static adsorption capacity of the monolith adsorbent was 106.8 mg g−1. The column was eluted by 1.0 mol L−1 HNO3 and recovery of Pb(II) was more than 97%. Moreover, the polymer monolith adsorbent shows superior reusability and stability. The precision and the accuracy of the proposed procedure were satisfactory by analyzing a standard reference material and three natural water samples. It was shown that the EP-EDA monolith was suitable for the preconcentration of environmental Pb(II) as an ion-selective SPE adsorbent.  相似文献   

19.
A new method for the fixation of polymethacrylate monoliths within titanium tubing of up to 0.8 mm I.D. for use as a chromatographic column under elevated temperatures and pressures is described. The preparation of butyl methacrylate–ethylene dimethacrylate-based monolithic stationary phases with desired porous structures was achieved within titanium tubing with pre-oxidised internal walls. The oxidised titanium surface was subsequently silanised with 3-trimethoxysilylpropyl methacrylate resulting in tight bonding of butyl methacrylate porous monolith to the internal walls, providing stationary phase stability at column temperatures up to 110 °C and at operating column pressure drops of >28 MPa. The titanium housed monoliths exhibited a uniform and dense porous structure, which provided peak efficiencies of up to 59,000 theoretical plates per meter when evaluated for the separation of small molecules in reversed-phase mode, under optimal conditions (achieved at 15 μL/min and temperature of 110 °C for naphthalene with a retention factor, k = 0.58). The developed column was applied to the reversed-phase isocratic separation of a text mixture of pesticides.  相似文献   

20.
An ionic‐liquid‐based polymer monolithic column was synthesized by free radical polymerization within the confines of a stainless‐steel column (50 mm × 4.6 mm id). In the processes, ionic liquid and stearyl methacrylate were used as dual monomers, ethylene glycol dimethacrylate as the cross‐linking agent, and polyethylene glycol 200 and isopropanol as co‐porogens. Effects of the prepolymerization solution components on the properties of the resulting monoliths were studied in detail. Scanning electron microscopy, nitrogen adsorption–desorption measurements, and mercury intrusion porosimetry were used to investigate the morphology and pore size distribution of the prepared monoliths, which showed that the homemade ionic‐liquid‐based monolith column possessed a relatively uniform macropore structure with a total macropore specific surface area of 44.72 m2/g. Compared to a non‐ionic‐liquid‐based monolith prepared under the same conditions, the ionic‐liquid‐based monolith exhibited excellent selectivity and high performance for separating proteins from complex biosamples, such as egg white, snailase, bovine serum albumin digest solution, human plasma, etc., indicating promising applications in the fractionation and analysis of proteins from the complex biosamples in proteomics research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号