首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the ability of several ionic liquids cations for electroosmotic flow modulation in capillary electrophoresis. Organic salts based on phosphonium, sulfonium, cysteinium, ammonium, and guanidinium cations were selected to study this property. In addition, the synergistic effect of these compounds in cyclodextrin chiral separation was also evaluated. In comparison with most studied imidazolium-based ionic liquids, several of the cations studied, are stronger modifiers in terms of electroosmotic flow (EOF) modulation. Phosphonium-based compounds and tri-octyl methylammonium chloride ([Aliquat]Cl) had the strongest ability to reverse EOF both in acidic and in basic conditions and had the lowest EOF reversal concentrations in the presence of hydroxypropyl-β-cyclodextrin. EOF modulation ability of phosphonium cations also contributed to the improvement of chiral separation of DL-propranolol by hydroxypropyl-β-cyclodextrin at lower concentrations in comparison with most commonly used EOF modulators such as tetrabutylammonium phosphate.  相似文献   

2.
Ionic substances with melting points close to room temperature are referred to as ionic liquids. Because ionic liquids are environmentally benign and are good solvents for a wide range of both organic and inorganic materials, interest for their potential uses in different chemical processes is increasing. In this paper, a capillary electrophoretic method for the analysis of basic proteins including lysozyme, cytochrome c, trypsinoge, and α-chymotyypsinogen A is reported. The method, in which 1-alkyl-3-methylimidazolium-based ionic liquids are used as the running electrolytes, leads to a surface charge reversal on the capillary wall. The effects of the alkyl group, imidazolium counterion, and the concentration of the ionic liquids were discussed. The optimum buffer system was a 90 mM 1-ethyl-3-methylimidazolium tetrafluoroborate (1E-3MI-TFB) solution. The applied voltage was −15 kV and detection was performed by monitoring absorbance at 240 nm. Baseline separation, high efficiencies, and symmetrical peaks of four proteins were obtained. The R.S.D. values of migration times and peak areas were <0.68 and <3.0%, respectively. The separation mechanism seems to involve association between the imidazolium cations and the proteins.  相似文献   

3.
A capillary electrophoresis method for separating preservatives with various ionic liquids as the electrolyte additives has been developed. The performances for separation of the preservatives using five ionic liquids with different anions and different substituted group numbers on imidazole ring were studied. After investigating the influence of the key parameters on the separation (the concentration of ionic liquids, pH, and the concentration of borax), it has been found that the separation efficiency could be improved obviously using the ionic liquids as the electrolyte additives and tested preservatives were baseline separated. The proposed capillary electrophoresis method exhibited favorable quantitative analysis property of the preservatives with good linearity (r2 = 0.998), repeatability (relative standard deviations ≤ 3.3%) and high recovery (79.4–117.5%). Furthermore, this feasible and efficient capillary electrophoresis method was applied in detecting the preservatives in soft drinks, introducing a new way for assaying the preservatives in food products.  相似文献   

4.
Chen G  Lin Y  Wang J 《Talanta》2006,68(3):497-503
During the past decade, significant progress in the development of miniaturized microfluidic systems has occurred due to the numerous advantages of microchip analysis. This review focuses on recent advances and the key strategies in microchip capillary electrophoresis (CE) with electrochemical detection (ECD) for separating and detecting a variety of environmental pollutants. The subjects covered include the fabrication of microfluidic chips, ECD, typical applications of microchip CE with ECD in environmental analysis, and future prospects. It is expected that microchip CE-ECD will become a powerful tool in the environmental field and will lead to the creation of truly portable devices.  相似文献   

5.
Yang X  Zhang X  Li A  Zhu S  Huang Y 《Electrophoresis》2003,24(9):1451-1457
A novel comprehensive two-dimensional (2-D) separation system coupling capillary high-performance liquid chromatography (cHPLC) with microchip electrophoresis (chip CE) is demonstrated. Reversed-phase cHPLC was used as the first dimension, and chip CE acted as the second dimension to perform fast sample transfers and separations. A valve-free gating interface was devised simply by inserting the outlet-end of LC column into the cross-channel on a specially designed chip. A home-made confocal laser-induced fluorescence detector was used to perform on-chip high-sensitive detection. The cHPLC effluents were continuously delivered to the chip and pinched injections of the effluents every 20 seconds were employed for chip CE separation. Gradient elution of cHPLC was carried out to obtain the high-efficiency separation. Free-zone electrophoresis was performed with triethylamine buffer to achieve high-speed separation and prevent sample adsorption. Such a simple-made comprehensive system was proved to be effective. The relative standard deviations for migration time and peak height of rhodamine B in 150 sample transfers were 3.2% and 9.8%, respectively. Peptides of the fluorescein isothiocyanate (FITC)-labeled tryptic digests of bovine serum albumin were fairly resolved and detected with this comprehensive 2-D system.  相似文献   

6.
The separation and UV absorbance detection of four toxic alkaloids, colchicine, thiocolchicine, colchicoside, and thiocolchicoside, on a microchip-based capillary electrophoresis device are reported. To increase the sensitivity of UV absorbance detection, optical cells with extended path lengths were integrated into the separation channel during the microfabrication process. The absorbance values realized on the microchip using these optical cells were proportional to the increase in average depths according to the Beer-Lambert Law, resulting in sensitivity enhancements by as much as five times. Linearity of response was observed from 5.0 to 500 mg L−1 of colchicine, with detection limits ranging from 2 to 6 mg L−1 depending upon the specific alkaloid and the dimension of the optical cell. The extraction of colchicine from spiked milk samples was performed and an average recovery rate of 83% with a relative standard deviation of 3.8% was determined using the optimized conditions on the microchip.  相似文献   

7.
Vickers JA  Henry CS 《Electrophoresis》2005,26(24):4641-4647
There is a need to develop broadly applicable, highly sensitive detection methods for microchip CE that do not require analyte derivatization. LIF is highly sensitive but typically requires analyte derivatization. Electrochemistry provides an alternative method for direct analyte detection; however, in its most common form, direct current (DC) amperometry, it is limited to a small number of easily oxidizable or reducible analytes. Pulsed amperometric detection (PAD) is an alternative waveform that can increase the number of electrochemically detectable analytes. Increasing sensitivity for electrochemical detection (EC) and PAD requires the isolation of detection current (nA) from the separation current (muA) in a process generally referred to as current decoupling. Here, we present the development of a simple integrated decoupler to improve sensitivity and its coupling with PAD. A Pd microwire is used as the cathode for decoupling and a second Au or Pt wire is used as the working electrode for either EC or PAD. The electrode system is easy to make, requiring no clean-room facilities or specialized metallization systems. Sensitive detection of a wide range of analytes is shown to be possible using this system. Using this system we were able to achieve detection limits as low as 5 nM for dopamine, 74 nM for glutathione, and 100 nM for glucose.  相似文献   

8.
Qiu H  Yin XB  Yan J  Zhao X  Yang X  Wang E 《Electrophoresis》2005,26(3):687-693
A simultaneous electrochemical (EC) and electrochemiluminescence (ECL) detection scheme was introduced to both microchip and conventional capillary electrophoresis (CE). In this dual detection scheme, tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) was used as an ECL reagent as well as a catalyst (in the formation of Ru(bpy)3(3+)) for the EC detection. In the Ru(bpy)3(2+)-ECL process, Ru(bpy)3(3+) was generated and then reacted with analytes resulting in an ECL emission and a great current enhancement in EC detection due to the catalysis of Ru(bpy)3(3+). The current response and ECL signals were monitored simultaneously. In the experiments, dopamine and three kinds of pharmaceuticals, anisodamine, ofloxacin, and lidocaine, were selected to validate this dual detection strategy. Typically, for the EC detection of dopamine with the presence of Ru(bpy)3(2+), a approximately 5 times higher signal-to-noise ratio (S/N) can be achieved than that without Ru(bpy)3(2+), during the simultaneous EC and ECL detection of a mixture of dopamine and lidocaine using CE separation. The results indicated that this dual EC and ECL detection strategy could provide a simple and convenient detection method for analysis of more kinds of analytes in CE separation than the single EC or ECL detection alone, and more information of analytes could be achieved in analytical applications simultaneously.  相似文献   

9.
A simple method to fabricate cylindrical carbon electrodes for use in capillary electrophoresis (CE) microchips is described. The electrodes were fabricated using a metallic wire coated with carbon ink. Several experimental variables were studied in order to establish the best conditions to fabricate the electrode. Finally, the electrodes were integrated in a poly(dimethylsiloxane) microchip and used for the analysis of phenolic compounds. Using the optimum conditions, the analysis of a mixture of dopamine, epinephrine, catechol, and 4-aminophenol was achieved in less than 240 s, showing good linear responses (R2 = 0.999) in the 0.1-190 μM range, and limits of detection (without the use of stacking or a decoupler) of 140 and 105 nM for dopamine and epinephrine, respectively.  相似文献   

10.
Chen G 《Talanta》2007,74(3):326-332
As two important polymorphs of carbon, carbon nanotube (CNT) and diamond have been widely employed as electrode materials for electrochemical sensing. This review focuses on recent advances and the key strategies in the fabrication and application of electrochemical detectors in microchip and conventional capillary electrophoresis (CE) using CNT and boron-doped diamond. The subjects covered include CNT-based electrochemical detectors in microchip CE, CNT-based electrochemical detectors in conventional CE, boron-doped diamond electrochemical detectors in microchip CE, and boron-doped diamond electrochemical detectors in conventional CE. The attractive properties of CNT and boron-doped diamond make them very promising materials for the electrochemical detection in microchip and conventional CE systems and other microfluidic analysis systems.  相似文献   

11.
A capillary electrophoresis (CE) microchip is utilized for the sensitive separation and detection of three trinitroaromatic explosives: 1,3,5-trinitrotoluene (TNT), 1,3,5-trinitrobenzene (TNB) and 2,4,6-trinitrophenyl-N-methylnitramine (tetryl), in the presence of 10 other explosives and explosive derivatives in nonaqueous electrolyte (acetonitrile/methanol 87.5/12.5 (v/v), 2.5 mM NaOH, 1 mM sodium dodecyl sulfate (SDS)). The chemical reaction of bases, e.g. hydroxide or methoxide ions, with trinitroaromatic compounds forms red colored derivatives that can be easily detected using a green light emitting diode (LED) on the microchip. Two surfactants bearing opposite charge, cetyltrimethylammonium bromide (CTAB) and SDS are compared with respect to their effect on separation times, detection limits and resolving powers for separating these explosives. All microchip separations were achieved in <20 s. In the absence of solid phase extraction (SPE), the detection limits obtained for the trinitroaromatic explosives were as follows: TNB, 60 μg/l; TNT, 160 μg/l and tetryl, 200 μg/l. By coupling the microchip separation with ex situ SPE, the detection limits for detecting these three explosives in seawater were lowered by 240 to more than 1000 times: TNB, 0.25 μg/l; TNT, 0.34 μg/l and tetryl, 0.19 μg/l.  相似文献   

12.
This review discusses recent progress in the application of one of the most effective in-line preconcentration techniques used in electrophoresis in capillaries and microchips, electrokinetic supercharging (EKS). Conventionally considered as a transient isotachophoresis (tITP) step put into effect after the electrokinetic sample injection (EKI), EKS presumes that the electrolyte filled into the capillary (or microchip channel) comprises a co-ion acting as a leading ion to stack the injected analytes. Subsequently, to create the tITP state, one needs an additional injection of a suitable terminating ion. As a resulting increase in sensitivity strongly depends on the performance of both EKS stages, two theoretical sections are focused on hints for proper arrangement of EKI and tITP elaborated by means of computer simulation. In particular, factors affecting the injected amount of analytes, different modes of introducing the sample, suitable combinations of leading and terminating ions, and optimization of supporting electrolyte compositions are discussed with an objective to increase the enrichment factors. A comprehensive coverage of recent EKS applications in capillary and microchip electrophoresis, including metal ions, pharmaceuticals, peptides, DNA fragments, and proteins, demonstrates attainable sensitivity enhancements up to two orders of magnitude. This should make this method exportable to other analytes and facilitate its more widespread use to applications that require low limits of detection.  相似文献   

13.
The use of traditional CE to detect weak binding complexes is problematic due to the fast-off rate resulting in the dissociation of the complex during the separation process. Additionally, proteins involved in binding interactions often nonspecifically stick to the bare-silica capillary walls, which further complicates the binding analysis. Microchip CE allows flexibly positioning the detector along the separation channel and conveniently adjusting the separation length. A short separation length plus a high electric field enables rapid separations thus reducing both the dissociation of the complex and the amount of protein loss due to nonspecific adsorption during the separation process. Thrombin and a selective thrombin-binding aptamer were used to demonstrate the capability of microchip CE for the study of relatively weak binding systems that have inherent limitations when using the migration shift method or other CE methods. The rapid separation of the thrombin-aptamer complex from the free aptamer was achieved in less than 10 s on a single-cross glass microchip with a relatively short detection length (1.0 cm) and a high electric field (670 V/cm). The dissociation constant was determined to be 43 nM, consistent with reported results. In addition, aptamer probes were used for the quantitation of standard thrombin samples by constructing a calibration curve, which showed good linearity over two orders of magnitude with an LOD for thrombin of 5 nM at a three-fold S/N.  相似文献   

14.
This paper presents an inexpensive and easy-to-implement voltage sequencer instrument for use in microchip capillary electrophoresis (MCE) actuation. The voltage sequencer instrument takes a 0–5 V input signal from a microcontroller and produces a reciprocally proportional voltage signal with the capability to achieve the voltages required for MCE actuation. The unit developed in this work features four independent voltage channels, measures 105 × 143 × 45 mm (width × length × height), and the cost to assemble is under 60 USD. The system is controlled by a peripheral interface controller and commands are given via universal serial bus connection to a personal computer running a command line graphical user interface. The performance of the voltage sequencer is demonstrated by its integration with a fluorescence spectroscopy MCE sensor using pinched sample injection and electrophoretic separation to detect ciprofloxacin in samples of milk. This application is chosen as it is particularly important for the dairy industry, where fines and health concerns are associated with the shipping of antibiotic-contaminated milk. The voltage sequencer instrument presented represents an effective low-cost instrumentation method for conducting MCE, thereby making these experiments accessible and affordable for use in industries such as the dairy industry.  相似文献   

15.
Room-temperature ionic liquids (ILs) are liquids that are constituted entirely of ions and can provide a solvent environment quite unlike any other available at room temperature. They continue to attract considerable interest in the chemistry research community as they are good solvents for a wide range of both inorganic and organic materials. In this study, a CZE method has been established for resolving natural flavonoids, quercetin, kaempferol and isorhamnetin in the Chinese herbal extract from Hippophae rhamnoides and its medicinal preparation (Sindacon Tablet). In this method, 1-alkyl-3-methyl-imidazolium-based ILs are used as the additive, and the effects of the alkyl group, imidazolium counterion (anionic part), along with the concentration of IL are investigated and discussed. Baseline separation, high efficiencies and symmetrical peaks of the three flavonoids were obtained. The separation mechanism seems to be the hydrogen-bonding interaction between the imidazolium cations of IL and the flavonoids.  相似文献   

16.
The separation of six kinds of aromatic acids by CZE with 1‐ethyl‐3‐methylimidazolium chloride (EMIMCl) and 1‐ethyl‐3‐methylimidazolium hydrogen sulfate (EMIMHSO4), two kinds of ionic liquids (ILs) as background electrolytes, and acetonitrile as solvent were investigated. The six kinds of aromatic acids can be separated under positive voltage with low IL concentration with either of the two ILs and separation with EMIMHSO4 is better in consideration of peak shapes and separation efficiency. But the migration order is different when the IL is different. Under negative voltage with high IL concentration, the six analytes can be separated with EMIMCl as background electrolytes and the migration order of the analytes is opposite to those with low concentration of EMIMCl as background electrolyte. The separations are based on the combination effects of heteroconjugation between the anions and cations in the ILs and the analytes, of which the heteroconjugation between the anions in the ILs and the analytes plays a dominant role. The heteroconjugation between the anions of the ILs and analytes is proton sensitive and only a very small amount of proticsolvents added into the electrolyte solution can harm the separation. When EMIMCl concentration is high, the heteroconjugation between the IL anions and the proton in the analytes make the effective mobility of the analytes much higher than the EOF and their migration direction reversed. Finally, the six aromatic acids in water samples were analyzed by nonaqueous CE with low concentration of EMIMHSO4 as background electrolytes with satisfactory results.  相似文献   

17.
研究了用微芯片毛细管电泳非接触电导检测系统快速测定加替沙星注射液中加替沙星的方法。对缓冲液的类型、浓度、分离电压以及进样时间等因素进行了优化。最佳条件为:缓冲液5.0 mmol/L HAc,分离电压2.0 kV,进样时间15.0 s。在该条件下,可在1.0 min内实现加替沙星的快速含量测定。线性范围为4.0~150μg/mL,检出限为1.0μg/mL,加标回收率为95.7%~101%,可成功测定注射液中加替沙星的含量。  相似文献   

18.
Potential possibilities of long‐chain ionic liquids based on imidazole (1‐dodecyl‐3‐methylimidazolium chloride and 1‐cetyl‐3‐methylimidazolium chloride) for online sample concentration techniques (field‐amplified sample stacking, head‐column field‐amplified sample stacking, and sweeping) of catecholamines were studied in both capillary zone electrophoresis and micellar electrokinetic chromatography. The use of a high‐conductivity sample matrix in sweeping was found to significantly increase the separation efficiency of analyte up to 2 × 106 theoretical plates per meter and remarkably reduce limits of detection for catecholamines up to 50 ng/mL. This approach was shown to be suitable for the determination of trace amounts of catecholamines in biological fluids.  相似文献   

19.
A capillary zone electrophoresis (CZE)-potential gradient detection (PGD) method coupled with field-amplified sample injection was developed to determine alkali metal, alkaline-earth metal, nickel, lead and ammonium ions. The capillary surface was coated with dialkylimidazolium-based ionic liquid and thus the electroosmotic flow (EOF) of the capillary was reversed. The buffer composed of 7.5 mM lactic acid, 0.6 mM 18-crown-6, 12 mM alpha-cyclodextrin (alpha-CD); it was adjusted to pH 4.0 by 1-hexyl-3-methylimidazolium hydroxide. The 11 cations were baseline separated within 14 min with 5.1-18.9 x 10(4) plates (for 40-cm-long capillary) in separation efficiency, and the detection limits were in the range of 0.27-7.3 ng/ml. The method showed good reproducibility in terms of migration time with RSD < or = 0.90% for run-to-run and < or = 1.65 for day-to-day assessment.  相似文献   

20.
A capillary zone electrophoresis method using only 1-alkyl-3-methylimidazolium-based ionic liquids as background electrolyte for the simultaneous determination of five anthraquinone derivatives including aloe-emodin, emodin, chrysophanol, physcion and rhein in Rhubarb species was described. Ion association constants, Kass, between anthraquinone anions and imidazolium cations were determined by analyzing the electrophoretic mobility change of anthraquinone anions using a non-linear least-squares method and factors contributing to ion associability were systematically clarified. For method optimization, several parameters such as ionic liquids concentration, background electrolyte pH and applied voltage, on the separation were evaluated and the optimum conditions were obtained as follows: 90 mM 1-butyl-3-methylimidazolium tetrafluoroborate (pH 11.0) with an applied voltage of 20 kV. Under these conditions, the method has been successfully applied to the determination of anthraquinones in extracts of two kinds of Rhubarb plants (R. palmatum and R. hotaoense) within 12 min. The method proposed herein was shown to be much simpler than the previously reported methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号