共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary A novel method of separating and detecting trace aluminum by capillary zone electrophoresis is described. Aluminum is reacted with lumogallion [4-chloro-3-(2,4-dihydroxyphenylazo)-2-hydroxybenzen-1-sulphonic acid] so that the complex can be selectively and sensitively detected by a laser-induced fluorescence detector after capillary electrophoretic separation. Using the proposed method, limits of detection in the sub parts per billion range are achieved. The technique is applied to the determination of aluminum in human serum. 相似文献
2.
A novel method is presented to detect DNA fragments separated by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection using inverse-flow derivatization. In electrophoresis, the intercalating dye, thiazol orange was only added to the separation buffer at the positive polarity. The negatively charged DNA fragments migrated from the negative polarity to the positive polarity, while the positively charged dye migrated in the opposite direction. When DNA fragments met with dye ions, the DNA–dye complexes were formed. The complexes continued migrating to the positive end, due to their net negative charges. When the complexes passed through the detection window, the fluorescent signals were generated. Importantly, DNA fragments migrated as their native state before DNA–dye complexes were formed. This procedure was used to detect double stranded DNA (dsDNA) and single stranded DNA (ssDNA) fragments, and polymerase chain reaction (PCR) products. The excellent resolution and good reproducibility of DNA fragments were achieved in non-gel sieving medium. This procedure may be useful in genetic mutation/polymorphism detections. 相似文献
3.
Sheng-da Qi Shun-lian Tian Hong-xi Xu Joseph J. Y. Sung Zhao-xiang Bian 《Analytical and bioanalytical chemistry》2009,393(8):2059-2066
Serotonin (5-hydroxytryptamine, 5-HT) plays vital roles in regulating gastrointestinal functions. Thus, the detection of 5-HT
in the gastrointestinal tract is of great importance for biomedical research, medical diagnosis, and pharmaceutical therapy.
This paper presents a simple, sensitive, and fast method for the quantification of luminally released serotonin in the feces
and tissues of the rat proximal colon by means of capillary electrophoresis with laser-induced fluorescence detection. 5-Carboxyfluorescein
N-succinimidyl ester was used for precolumn derivatization of serotonin. The optimal separation and detection conditions were
obtained with an electrophoretic buffer containing 60 mM borate (pH 8.90) and an air-cooled argon-ion laser (excitation at
488 nm, emission at 520 nm). The serotonin concentrations in the feces and tissues of proximal colons were analyzed with this
method, and the average values of serotonin in the feces samples were 1.951 ± 0.446 ng/mg (male) and 2.095 ± 0.533 ng/mg (female)
and 1.397 ± 0.267 ng/mg in rat proximal colon tissues. The results demonstrate that this method can accurately determine luminally
released 5-HT in rats. 相似文献
4.
Capillary array electrophoresis (CAE) is an important high throughput analytical technique. Laser-induced fluorescence (LIF) has been the dominant detection method for CAE owing to its low limit of detection (LOD) and wide linear dynamic range (LDR). Linear LIF scanners were first used in CAE because linear motions of an objective match well with a common planar array of capillaries. A problem with linear scanners is that the motor is required accelerating/decelerating so that all capillaries can be properly scanned, which makes motion control complicated and reduces the duty cycle. Rotary scanners were developed to overcome this problem. While rotary scanners have been successfully applied in CAE, the capillaries have to be arranged in a circular format, which can be inconvenient in some cases. In this report, we describe a cam-based LIF scanner as an alternative technique for CAE detection. In this system, a rotary motor is mechanically linked with a capillary holder via a cam. During operation, the motor carries the cam in a rotary motion that drives an array of capillaries on the holder to move back and forth across the objective for fluorescence detection. Using this design, the capillaries can be parallel-arranged in a plane while the motor acceleration/deceleration is avoided. To demonstrate the feasibility of this approach, we constructed a prototype instrument with a constant-velocity scanning distance of ∼10 mm, a scanning frequency of 3 Hz and a duty cycle of ∼70%. The scanner exhibited a LOD of 69 pM of fluorescein and a LDR of 3.5 orders of magnitude. Multiplexed capillary SDS-PAGE was performed on this scanner for protein separations. 相似文献
5.
Jiang RM Chang YS Chen SJ Chen JH Chen HC Chang PL 《Journal of chromatography. A》2011,1218(18):2604-2610
In this study, we developed a novel assay that simultaneously detects multiple miRNAs (microRNAs) within a single capillary by combining a tandem adenosine-tailed DNA bridge-assisted splinted ligation with denaturing capillary gel electrophoresis with laser-induced fluorescence. This proposed method not only represents a significant improvement in resolution but also allows for the detection of multiple miRNAs within a single capillary based on the length differences of specified target bridge DNA. The assay's linear range covers three orders of magnitude (1.0 nM to 1.0 pM) with a limit of detection (S/N=3) as low as 190 fM (2.5 zmol). Five miRNAs of Epstein-Barr virus (EBV) were also detected in EBV-infected nasopharyngeal carcinoma cells, while they did not appear in non-virus infected cells. Moreover, the electropherogram indicated that the screening of isomiRs (isomer of miRNA) of BART2 by CE-LIF is feasible by our proposed method. The developed electrophoresis-based method for miRNA detection is fast, amplification-free, multiplexed and cost-effective, making it potentially applicable to large-scale screening of isomiRs. 相似文献
6.
Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of recombinant hirudin (r-hirudin), a specific and reproducible analysis method is required. Capillary electrophoresis (CE) is rapidly becoming an important procedure for the analysis of biological molecules. Recently, CE combined with immunoassay has emerged as a new analytical technique. CE-based immunoassay (CEIA) is a sensitive and specific method combining laser-induced fluorescence (LIF) and immunoassay. Therefore, in this study, we specifically investigated fluorescence labeling and determination of r-hirudin by CEIA with a LIF detector using labeled r-hirudin and polyclonal antibody. r-Hirudin was labeled with fluorescein isothiocyanate (FITC). FITC-labeled r-hirudin was purified using high-performance liquid chromatography (HPLC). The method is based on preincubation of r-hirudin and antibody for 20 min, followed by CE analysis using an uncoated capillary. Free and bound r-hirudin were separated within 5 min using CE with high reproducibility. This study demonstrated that the CEIA method could be applied to quantitative analysis of r-hirudin in biological fluids. 相似文献
7.
This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood. 相似文献
8.
Short oxidized multi-walled carbon nanotubes were functionalized with fluorescein isothiocyanate to form carbon nanotube probes (CNTP). The distribution of CNTP in yeast was quantitatively determined by capillary electrophoresis coupled with laser-induced fluorescence detection. The detection sensitivity for CNTP was greatly improved comparing with UV absorbance and Raman detection. The time- and temperature-dependent influx patterns of CNTP into yeast were obtained. The apparent permeability coefficient for influx of CNTP into yeast was calculated, which suggested that CNTP might permeate into yeast through endocytosis. This study implies that CNTP could be a fine drug transporter and might be wildly used in multidrug resistance research and microorganism detection. 相似文献
9.
Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization. 相似文献
10.
A new capillary electrophoresis (CE) method with laser-induced fluorescence (LIF) detection was developed for the rapid separation and sensitive detection of glutathione (GSH) and glutathione disulfide (GSSH) after derivatization by 4-chloro-7-nitrobenzo-2-oxa-1,3-diazol (NBD-Cl). The derivatization and separation conditions were investigated in detail and the optimums were obtained. Under the optimum experiment conditions, linear relationships between the peak height and concentrations of the analytes in normal and second-derivative electrophoregrams were obtained (0.22-45.00 μM). The detection limits for glutathione and glutathione disulfide in normal and second-derivative electrophoregrams were 0.046 and 0.012 μM and 0.046 and 0.014 μM, respectively. The method was applied to the analysis of glutathione and glutathione disulfide in human plasma and tobacco leaves with satisfactory results. 相似文献
11.
A common method for quantifying cell death is measuring the concentration of lactate dehydrogenase (LDH) released by cells as their membranes become unstable. In cells expressing green fluorescent protein (GFP), degradation of the cell membrane also results in the release of GFP into the surrounding supernatant. In this study, we used capillary electrophoresis with laser-induced fluorescence detection to measure the levels of GFP in supernatants of UBIGFP/BL6 primary macrophages that had been infected with Salmonella typhimurium, treated with staurosporine, or exposed to H2O2, all known inducers of cell death. We also used a standard LDH assay to measure the release of LDH into supernatants. We observed the rate of cell death quantified by release of GFP and LDH into supernatant to be essentially identical, demonstrating that GFP release is at least as good as an indicator of macrophage cell death as the established LDH release method. 相似文献
12.
Benturquia N Couderc F Sauvinet V Orset C Parrot S Bayle C Renaud B Denoroy L 《Electrophoresis》2005,26(6):1071-1079
Serotonin or 5-hydroxytryptamine (5-HT) is a major neurotransmitter in the central nervous system. In this work, a method for analyzing 5-HT in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. A pH-mediated in-capillary preconcentration of samples was performed, and after separation by capillary zone electrophoresis, native fluorescence of 5-HT was detected by a 266 nm solid-state laser. The separation conditions for the analysis of 5-HT in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical bases. Separation of 5-HT was performed using a 80 mmol/L citrate buffer, pH 2.5, containing 20 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and +30 kV voltage. The detection limit was 2.5 x 10(-10) mol/L. This method allows the in vivo brain monitoring of 5-HT using a simple, accurate CE measurement in underivatized microdialysis samples. 相似文献
13.
14.
Valerie A. Frerichs Jennifer K. Herrmann Alfredo Aguirre Luis A. Coln 《Microchemical Journal》2004,78(2):135-142
An analytical method was developed to determine the undecapetide substance P (SP) based on capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. SP was derivatized with the fluorogenic reagent 2,3-naphthalenedicarboxaldehyde (NDA) prior to injection into the CE-LIF system. The pre-column derivatization scheme combined with injection enhancement techniques extends the detectability of SP to the subnanomolar level. Limit of detection (LOD) of 100 pM was achieved without pre-concentrating the sample prior to injection. The reproducibility for six different preparations of a standard sample containing 5 nM of SP was 6.8% RSD and that of the CE migration time was 0.08% RSD. The method was used to determine SP in a saliva sample. 相似文献
15.
16.
A rapid method using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was developed to determine free and protein-bound glutathione (GSH) in human HepG2 hepatocarcinoma cells. The samples were derivatized with 5-iodoacetamidofluorescein (5-IAF), and analyzed at 22 kV using sodium phosphate buffer (10mM, pH 11.4) and an uncoated 58 cm x 75 microm I.D. fused silica capillary. The analysis time was less than 10 min and N-acetylcysteine was used as internal standard. The derivatization conditions, such as reaction time, 5-IAF concentration, running buffer and cartridge temperature were optimized. Argon gas was used in the study to prevent the oxidization of GSH during sample preparation. The optimized method required only 30-40 nl sample per analysis and was fast and sensitive. The method was applied to the analyses of HepG2 cells treated with the small metal chelating agent, pyrrolidine dithiocarbamate (PDTC). The results demonstrate that the amount of protein-bound GSH, which reflects the amount of protein S-glutathionylation, increased in a time-dependent manner upon cell treatment with PDTC, reaching a maximum of over 50% increase 2h post-PDTC. 相似文献
17.
Soichiro Ijiri Kenichiro Todoroki Hideyuki Yoshida Takashi Yoshitake Hitoshi Nohta Masatoshi Yamaguchi 《Journal of chromatography. A》2010,1217(18):3161-3166
Rhodamine 110 (Rho110) has been used in the highly sensitive analysis of monosaccharides, as it reacts with the reducing carbonyl group of the saccharides. The monosaccharide derivatives were investigated by capillary electrophoresis with laser-induced fluorescence detection. The derivatization was performed at 90 °C for 30 min for all monosaccharides. The derivatized monosaccharides were separated using 200 mM borate (pH 10.5) as running buffer within 20 min. The fluorescence intensities of Rho110-derivatives were significantly decreased by the presence of excess reducing agent, but were greatly increased by the addition of potassium hexacyanoferrate(III). The concentration and mass detection limits for monosaccharides were in the range of 1.4–2.8 nM and 36–70 amol, respectively. We have applied this derivatization method to the analysis of the composition of monosaccharides in glycoproteins (ribonuclease B, fetuin, and erythropoietin) following their subjection to strong acid hydrolysis. The results from these analyses were in good agreements with the reported values established previously. 相似文献
18.
Maria Teresa Veledo Cristina Pelaez-Lorenzo Mercedes de Frutos 《Analytica chimica acta》2010,658(1):81-86
Capillary electrophoresis (CE) coupled with laser-induced fluorescence detection (LIF) has allowed to obtain protein fingerprints, which have demonstrated to be useful in microorganisms characterization. In this work, protein fingerprints of two species of Staphylococcus grown in different culture media and submitted to temperature and nitrosative stress were studied by CE-LIF. After the growth of the bacteria, protein extracts were obtained by cell lysis using sonication. The water-soluble fraction of these lysates was derivatized on-capillary with a fluorogenic dye, 3-(2-furoyl)quinoline-2-carboxaldehyde. The fluorescent products were analyzed by CE using phosphate buffer containing submicellar concentrations of sodium pentanesulfate and detected by LIF. Different protein fingerprints were obtained depending on the bacterial specie studied, indicating the usefulness of this method for the identification of different species of the same bacterial genus. It was also demonstrated that the CE protein fingerprints were dependent on the culture conditions, such as growth medium, or on stressing conditions, such as heat shock or nitrosative stress. 相似文献
19.
A simple and sensitive capillary electrophoretic immunoassay (CEIA) was described for the determination of estriol (E3) in pregnant women's serum. The method was based on the competitive reaction of fluorescein-labeled E3 antigen and E3 with limited amounts of monoclonal antibody. The addition of the thermally reversible hydrogel, poly-N-iso propylacrylamide (pNIPA) in the buffer serving as a replaceable packing material, improved the reproducibility of the method. With laser-induced fluorescence detector (LIF), this method can be applied to determine E3 at concentrations lower to 31.6 pg ml−1. Recoveries from human steroid-free serum matrix were greater than 94% with relative standard deviation (R.S.D.) values less than 3.5%. Serum E3 levels of ten normal pregnant women were measured at the range of 10.2-15.6 ng ml−1. 相似文献
20.
Short oxidized multi-walled carbon nanotubes (CNT) were derivatized with fluorescein isothiocyanate (FITC). Capillary electrophoresis
coupled with laser-induced fluorescence (CE–LIF) was then used to separate and detect the fluorescently labeled carbon-nanotube
probes (CNTP) in multidrug-resistant cells (K562A) and the parent cells (K562S). Greater expression of P-glycoprotein in K562A
cells than in K562S cells was confirmed by use of anti-P-glycoprotein antibody and flow-cytometric analysis. Analyses of CNTP
in both cell lines using both CE–LIF and flow cytometry showed that CNTP could traverse the cellular membrane without being
pumped out by P-glycoprotein. The CNTP distributed in both cell lines was analyzed at the single cell level and the results
were compared with those from analysis of ten cells and of the lysate from bulk cells. The results revealed the CE–LIF method
could be used for quantitative analysis of CNT in single cells in studies of drug delivery and multidrug resistance.
相似文献