共查询到20条相似文献,搜索用时 10 毫秒
1.
We have analyzed phosphorus in an enzymatically digested DNA molecule using capillary electrophoresis (CE) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). The DNA concentration was quantified by the phosphorus value obtained in the CE-ICP-MS analysis. The CE-ICP-MS measurement, for which the interface device AIF-01 equipped three layered nebulizer was adopted, was achieved with limited μL/min nebulizing without loss of sample in the vaporizing chamber. The samples of nucleotides and free phosphate were separated well in the CE-ICP-MS measurement, and the calibration curve (0.1-10μg/mL) of the phosphorus showed a linear (R(2)=0.999) increase in intensity. After digestion of the 100-bp double-strand DNA sample to deoxyribonucleotide-5'-monophosphates (dNMPs) by phosphodiesterase-I, phosphorus was detected by CE-ICP-MS without further purification steps. In this study, we applied two calculation schemes of DNA analysis using a dNMP concentration obtained from CE-ICP-MS. Comparative CE-ICP-MS analysis with DNA digested to dNMPs showed that the assay gave an equal value obtained from the total DNA quantification using fluorescence detection. The detection limits of the DNA sample obtained from these species and phosphorus in nucleotides using CE-ICP-MS were 3.1-26ng/mL. These LOD values were equal to the conventional fluorescence determination of DNA. 相似文献
2.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article. 相似文献
3.
In this work, a novel and high-efficiency interface has been developed in coupling CE with inductively coupled plasma MS (ICPMS). The interface completely avoids laminar flow in CE capillary caused by the suction of nebulizer, and can be easily and stably operated at room temperature with high analyte transport efficiency to ICPMS. The new interface has a liquid dead volume smaller than 5 nL, which was much smaller than those (65-2500 microL) reported previously for other interfaces. All above features led to a higher sensitivity and a better electrophoretic resolution for CE-ICPMS coupled with this new interface. With the help of this new interface, we have successfully separated and determined five species of arsenic, As(III), As(V), monomethylarsonic acid, dimethylarsinic acid and p-aminophenylarsonic acid using CE-ICPMS within 11 min with a detection limit of 0.046-0.075 ng/mL and an RSD of 2-6% (n=6). 相似文献
4.
The determination of sulfur in biologically relevant samples such as metalloproteins is described. The analytical methodology used is based on robust on-line coupling between capillary electrophoresis (CE) and octopole reaction cell inductively-coupled plasma mass spectrometry (ORC–ICP–MS). Polyatomic ions that form in the plasma and interfere with the determination of S at mass 32 are minimised by addition of xenon to the collision cell. The method has been applied to the separation and simultaneous element-specific detection of sulfur, cadmium, copper, and zinc in commercially available metallothionein preparations (MT) and metallothionein-like proteins (MLP) extracted from liver samples of bream (Abramis brama L.) caught in the river Elbe, Germany. Instrumental detection limits have been calculated according to the German standard procedure DIN 32645 for the determination of sulfur and some simultaneously measured trace elements in aqueous solution. For sulfur detection limits down to 1.3 g L–1 (34S) and 3.2 g L–1 (32S) were derived. For the other trace elements determined simultaneously detection limits ranging from 300 ng L–1 (58Ni) to 500 ng L–1 (66Zn, 55Mn) were achieved. For quantification of sulfur and cadmium in a commercially available MT preparation under hyphenated conditions the use of external calibration is suggested. Finally, the need for proper sample-preparation technique will be discussed. 相似文献
5.
Daniela KretschyAuthor Vitae Gunda KoellenspergerAuthor VitaeStephan Hann 《Analytica chimica acta》2012
This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given. 相似文献
6.
Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry 总被引:1,自引:0,他引:1
S. A. Baker N. J. Miller-Ihli 《Spectrochimica Acta Part B: Atomic Spectroscopy》2000,55(12):1823-1832
The determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS) was investigated. Both capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) modes of operation were studied. The optimal separation of four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5′-deoxyadenosylcobalamin) and a potentially harmful corrinoid analogue (cobinamide dicyanide) was obtained using CZE at a pH of 2.5. Both 20 mM phosphate and 20 mM formate buffers were used with success, although the formate buffer provided improved resolution. The CZE-ICP-MS method was used to quantify cyanocobalamin in a vitamin supplement and the analytical results were in good agreement (±5%) with values obtained by ICP-MS for total Co levels. The solution detection limits for cobalamins using CZE-ICP-MS were approximately 50 ng/ml. MEKC was found to be useful for the screening of vitamin preparations because it provided a rapid means of distinguishing cyanocobalamin (the form most commonly used in vitamin preparations) from free cobalt. The separation of free cobalt and cyanocobalamin using MEKC was achieved in less than 10 min. 相似文献
7.
Capillary electrophoresis dynamic reaction cell™ inductively coupled plasma mass spectrometry (CE-DRC-ICP-MS) for the determination of sulfur-containing amino acids is described. The sulfur-containing amino acids studied include l-cysteine, l-cystine, dl-homocystine and l-methionine. The species studied were well separated using a 70 cm length×75 μm i.d. fused silica capillary while the applied voltage was set at +22 kV and a 10 mmol l−1 disodium tetraborate buffer (pH 9.8) containing 0.1 mmol l−1 EDTA and 0.5 mmol l−1 Triton X-100 was used as the electrophoretic buffer. The sulfur-selective electropherogram was determined at m/z 48 as by using its reaction with O2 in the reaction cell. The method avoided the effect of polyatomic isobaric interferences at m/z 32 caused by and on by detecting as the oxide ion at m/z 48, which is less interfered. The detection limit of various species studied was in the range of 0.047-0.058 μg S ml−1, which corresponded to the absolute detection limit of 1.3-1.6 pg S based on the injection volume of 27 nl. We determined the concentrations of selected sulfur-containing amino acids in urine and nutritive complement samples. The recovery was in the range of 92-128% for various species. 相似文献
8.
An inductively coupled plasma mass spectrometer (ICP–MS) equipped with a dynamic reaction cell (DRC) was used for the determination of Ca and P in foodstuffs. In this study, two different reaction gases, CH4 and O2, were introduced successively through the different channels to alleviate different interferences in the same analysis run. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio for each element. The interfering 40Ar+ at m/z 40 was reduced in intensity by up to five orders of magnitude by using 1.0 mL min–1 CH4 as reaction cell gas in the DRC. On the other hand, by using O2 as the reaction gas, 31P+ was converted to 31P16O+ that could be detected at m/z 47 where there was less interference. The limits of detection for Ca and P were 0.2 ng mL–1 and 0.3 ng mL–1, respectively. This method was used to determine the concentrations of Ca and P and the ratio of Ca to P in NIST SRM 1549 non-fat milk powder and NIST RM 8345 whole milk powder reference materials and an infant milk powder and an infant cereal-rice sample purchased locally. The results for the reference samples agreed satisfactorily with the reference values. The accuracy of the determination was better than 4.1 and 0.9% for Ca and P, respectively. The results for infant milk powder and infant cereal were also found to be in good agreement with the value on the bottle label. Precision (RSD) between sample replicates was better than 4.8% for all the determinations. 相似文献
9.
Aurlien Pitois Laura Aldave de Las Heras Maria Betti 《International journal of mass spectrometry》2008,270(3):118-126
Determination of fission products and of their isotopic composition is of high importance for the characterisation and complete inventory of nuclear fuels. Radiometric and mass spectrometric methods, which are currently used, enable only an incomplete determination of the fission products. Radiometric methods cannot be applied to all fission products and mass spectrometric methods are hindered by the existence of isobaric interferences, therefore a previous chemical separation is required before mass spectrometric analysis. Capillary electrophoresis (CE) has been coupled with inductively coupled plasma mass spectrometry (both ICP-QMS and ICP-SFMS). Typical detection limits of 6 ng/mL and 4 pg/mL for caesium as well as 8 ng/mL and 7 pg/mL for lanthanides have been obtained by CE-ICP-QMS and CE-ICP-SFMS, respectively. In addition to these very low detection limits, the procedures present the advantages to be fast (6 min for caesium and 13 min for lanthanides, respectively), to require a low microliter range sample volume and a nanoliter range injection volume. The radiation dose for the personnel as well as the volume of nuclear liquid wastes generated during the measurements are consequently reduced.The procedures have been applied to nuclear samples from PUREX process and leachates from MOX fuels. 相似文献
10.
高效液相色谱-电感耦合等离子体质谱联用检测食品中的五种硒形态 总被引:7,自引:0,他引:7
建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。 相似文献
11.
The presence of chromium in chromium-tanned leather represents a considerable health problem since it can lead to chronic allergic contact dermatitis. Apart from trivalent chromium (Cr(III)), which is used for tanning, leather often contains hexavalent chromium (Cr(VI)), resulting from the oxidation of Cr(III) during the tanning process. This study deals with the chromium compounds in simulated sweat when brought into contact with Cr(III) or Cr(VI) and with chromium-tanned leathers. A capillary electrophoresis (CE) method was developed, with inductively coupled plasma-sector field-mass spectrometry (ICP-SF-MS) for element-specific detection. Two different electrophoretic runs, applying once the positive and once the negative polarity mode, were necessary for the detection of positively and negatively charged chromium species. Although sometimes described in the literature, a pre-run derivatization of the chromium-species was not performed here to prevent species transformation. 50 mmol.L(-1) sodium phosphate at a pH of 2.5 was used as CE separation buffer and as make-up liquid for the CE-ICP-SF-MS interface. When applied to simulated sweat samples incubated with Cr(VI), this method showed that methionine is responsible for the reduction of Cr(VI) into Cr(III), which, at its turn, forms a complex with lactic acid. In the case of sweat plus Cr(III), the latter step was also seen. Applied to simulated sweat in contact with leather samples, the method developed showed the presence of the former species among a much more complex pattern. 相似文献
12.
There is an ongoing debate regarding the mechanism of Pt electrochemical dissolution. However, only off-line methods have so far been used, where separation of Pt species is performed separately from their detection. In this study, ion exchange chromatography coupled to inductively coupled plasma mass spectrometry was used for the first time to separate and detect Pt species generated by the electro-dissolution of a Pt electrode in 0.5 M aqueous H2SO4 solution. Because these species are either neutral or cationic, they were converted to chloro-complexes using 0.1 M KCl to enable their separation by anion exchange chromatography. Chloro-aqua complexes were observed in addition to the two predominant species, namely PtCl42− and PtCl62−. A good linear relationship was observed between the sum of peak areas for all complexes of a given Pt oxidation state and the Pt concentration, with a detection limit of 0.1 μg L−1 being reached for Pt(II) and Pt(IV). Application of this speciation analysis method to real samples generated by potential cycling using cyclic voltammetry (CV) revealed that, in general, at least 80% of Pt was present as Pt(II), irrespectively of the cyclic potential range or of temperature (up to 60 °C). Still, quantitative spike recovery was achieved after adding known amounts of Pt(II) or Pt(IV) to a sample prepared by CV, which demonstrated that no significant species inter-conversion took place. 相似文献
13.
Sylwia Studzińska Sandra Mounicou Joanna Szpunar Ryszard Łobiński Bogusław Buszewski 《Analytica chimica acta》2015
This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of 31P may be used to quantify these compounds at the level of 80 μg L−1, while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L−1. The limit of detection was in the range of 0.07 and 0.13 mg L−1. Accuracy varied with concentration, but was in the range of 3%. 相似文献
14.
为了准确测定茶叶中铬酸铅的含量,为市场监管提供判断依据,本文建立了微波灰化-高效液相色谱-电感耦合等离子体质谱仪测定茶叶中铬酸铅的方法。茶叶样品经微波灰化仪在500 ℃的条件下,灰化50 min后,用0.25 mol·L-1的NaOH和0.14 mol·L-1的Na2CO3混合碱性提取液在90 ℃-95 ℃温度下不间断搅拌提取10 min,提取液经色谱柱分离后,用ICP-MS测定52Cr。研究表明该方法在5.00 μg·L-1-500 μg·L-1范围内,线性良好,相关系数为0.9998,方法检出限低至2.5 mg·kg-1,三水平加标回收率为91.30 %~95.33 %,精密度在1.14 %~1.99 %之间。与电炉灼烧茶叶相比,微波灰化茶具有检出限低,精密度高,准确度良好等特性,能够满足茶叶中铬酸铅的测定。
关键词 微波灰化;高效液相色谱-电感耦合等离子体质谱法;铬酸铅;茶叶 相似文献
15.
On‐line coupling of LC and ICP‐MS has been used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography provided better separation capability (both intra‐ and inter‐element) than size‐exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris–HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, enabling good chromatographic separation, and is acceptable for mass spectrometry too. The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method. The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty. The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
16.
A novel and simple analytical procedure has been developed for the trace-level determination of lanthanides (rare-earth elements) in uranium-bearing materials by inductively coupled plasma sector-field mass spectrometry (ICP-SFMS). The method involves a selective extraction chromatographic separation of lanthanides using TRU™ resin followed by ICP-SFMS analysis. The limits of detection of the method proposed is in the low pg g−1 range, which are approximately two orders of magnitude better than that of without chemical separation. The method was validated by the measurement of reference material and applied for the analysis of uranium ore concentrates (yellow cakes) for nuclear forensic purposes, as a potential application of the methodology. 相似文献
17.
This work demonstrated the feasibility of mercury speciation analysis by anion exchange chromatographic separation with inductively coupled plasma mass spectrometry detection. For the first time, by complexing with the mobile phase containing 3-mercapto-1-propanesulfonate into negatively charged complexes, fast separation of inorganic mercury (Hg2+), monomethylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) was achieved within 5 min on a 12.5-mm strong anion exchange column. The detection limits for Hg2+, MeHg, EtHg and PhHg were 0.008, 0.024, 0.029 and 0.034 μg L−1, respectively. The relative standard deviations of peak height and peak area (5.0 μg L−1 for each Hg species) were all below 3%. The determined contents of Hg2+, MeHg and total Hg in a certified reference material of fish tissue by the proposed method were in good accordance with the certified values with satisfactory recoveries. The relative errors for determining MeHg and total mercury were −2.4% and −1.2%, respectively, with an acceptable range for spike recoveries of 94–101%. Mercury speciation in 11 fish samples were then analyzed after the pretreated procedure. The mercury contents in all fish samples analyzed were found compliant with the criteria of the National Standards of China. 相似文献
18.
电感耦合等离子体质谱技术最新进展 总被引:22,自引:0,他引:22
对1998年以来电感耦合等离子体质谱技术(ICP-MS)的最新进展作一简要回顾。内容包括同位素比值分析、双聚焦扇形磁场高分辨ICP-MS、多接收器磁扇形等离子体质谱仪(MC-ICP-MS)、飞行时间等离子体质谱仪(ICP-TOF-MS)、“冷”等离子体及屏蔽炬技术以及动态碰撞/反应池技术等进展。 相似文献
19.
《Journal of separation science》2017,40(19):3898-3904
We report a simple and highly sensitive method for the simultaneous detection of trace zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate by capillary electrophoresis with inductively coupled plasma mass spectrometry. Zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate were chelated with trans‐1,2‐diaminocyclohexane‐N,N,N′,N′‐tetraacetic acid to form a macromolecule complex. Then, these two compounds were separated by α‐cyclodextrin‐modified capillary electrophoresis within 12 min at a separation voltage of 15 kV and measured by inductively coupled plasma mass spectrometry. The developed method is sensitive with detection limit of 1.9 and 3.0 ng Zn/mL for zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate, respectively. By means of ultrasound‐assisted extraction methods, zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate spiked into cabbage leaves were successfully extracted and determined with a relative standard deviation (n = 5) ≤ 6% and a recovery of 95–107%. 相似文献
20.
锆钛矿组成成分复杂,存在耐高温的锆、钛化合物,不易分解,且铪以类质同象进入锆矿物,导致锆钛矿中的铪含量不均,因此完全分解锆钛矿并准确测定其中含量不同的铪成为一个难题。本文建立了碳酸钠-硼砂高温熔融,以178Hf为分析同位素及50 ng/mL185Re为内标,使用电感耦合等离子体质谱法(ICP-MS)测定锆钛矿中铪的新方法,可准确锆钛矿中含量不均的铪。实验研究了锆钛矿成分及其熔融方法,结果表明碳酸钠-硼砂高温熔融效果最好,可完全溶解耐高温难分解的锆钛矿,当碳酸钠-硼砂质量配比为2:1时熔融效果最佳。电感耦合等离子体质谱法具有检出限低、灵敏度高、线性范围宽等优势,可用于测定锆钛矿中含量不均的铪,ICP-MS蠕动泵转速为45 rpm、雾化流量为1.06 L/min时雾化效率最优。在选定的实验条件下,HfO2质谱强度与其质量浓度在0.01~250 ng/mL范围内呈良好的线性关系,相关系数为0.9997,背景等效浓度为0.029 ng/mL,方法检出限为0.0032 ng/mL。按实验方法对中国国家标准物质中的HfO2进行测定,测定值与认定值一致,相对标准偏差在1.6%~3.2%之间。按实验方法对锆钛矿样品中的HfO2进行测定并进行加标回收率实验,测定结果的相对标准偏差(RSDs,n=9)在0.9~3.4%之间,加标回收率在96%~106%之间,满足国家地质矿产行业标准DZ/T 0130—2006的要求。 相似文献