首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Stir bar sorptive extraction is a powerful technique for the extraction and analysis of organic compounds in aqueous matrices. Carbonyl compounds are ubiquitous components in rainwater, however, it is a major challenge to accurately identify and sensitively quantify carbonyls from rainwater due to the complex matrix. A stir bar sorptive extraction technique was developed to efficiently extract carbonyls from aqueous samples following chemical derivatization by O‐(2,3,4,5,6‐pentafluorobenzyl) hydroxylamine hydrochloride. Several commercial stir bars in two sizes were used to simultaneously measure 29 carbonyls in aqueous samples with detection by gas chromatography with mass spectrometry. A 100 mL aqueous sample was extracted by stir bars and the analytes on stir bars were desorbed into a 2 mL solvent solution in an ultrasonic bath. The preconcentration Coefficient for different carbonyls varied between 30 and 45 times. The limits of detection of stir bar sorptive extraction with gas chromatography mass spectrometry for carbonyls (10–30 ng/L) were improved by ten times compared with other methods such as gas chromatography with electron capture detection and stir bar sorptive extraction with high‐performance liquid chromatography and mass spectrometry. The technique was used to determine carbonyls in rainwater samples collected in York, UK, and 20 carbonyl species were quantified including glyoxal, methylglyoxal, isobutenal, 2‐hydroxy ethanal.  相似文献   

2.
Headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography with ion trap mass spectrometric detection and with atomic emission detection (GC-AED) was employed to identify possible odor-impact volatile organic compounds in cupuassu (Theobroma grandiflorum Spreng) liquor, as well as to quantify alkylpyrazines present in these samples. SPME fibers coated with 100 microm polydimethylsiloxane (PDMS), 65 microm PDMS-divinylbenzene (DVB) and 75 microm Carboxen (CAR)-PDMS were tested, the later being chosen for the optimized extraction procedure. The principal compounds found in the sample headspace were 3-methylbutanal, dimethylsulfide, dimethyldisulfide, beta-linalool and several alkylpyrazines (notably tetramethylpyrazine). The procedure for quantitation of the alkylpyrazines, using GC-AED for their separation and detection, allowed the detection of microg g(-1) levels of the analytes in the samples, with acceptable precision (R.S.D. less than 10%).  相似文献   

3.
This report describes the use of PDMS ME coupled with amperometric detection for rapid separation of ascorbic, gallic , ferulic, p‐coumaric acids using reverse polarity. ME devices were fabricated in PDMS by soft lithography and detection was accomplished using an integrated carbon fiber working electrode aligned in the end‐channel configuration. Separation and detection parameters were investigated and the best conditions were obtained using a run buffer consisting of 5 mM phosphate buffer (pH 6.9) and a detection voltage of 1.0 V versus Ag/AgCl reference electrode. All compounds were separated within 70 s using gated injection mode with baseline resolution and separation efficiencies between 1200 and 9000 plates. Calibration curves exhibited good linearity and the LODs achieved ranged from 1.7 to 9.7 μM. The precision for migration time and peak height provided maximum values of 4% for the intrachip studies. Lastly, the analytical method was successfully applied for the analysis of ascorbic and gallic acids in commercial beverage samples. The results achieved using ME coupled with amperometric detection were in good agreement with the values provided by the supplier. Based on the data reported here, the proposed method shows suitability to be applied for the routine analysis of beverage samples.  相似文献   

4.
For monitoring groundwater at tar oil contaminated sites a simple method of analysis was developed for the simultaneous detection of several NSO heterocyclic compounds, homocyclic compounds, mobile two- and three-cyclic PAHs and selected metabolites. The groundwater samples are enriched using SPE with polymer material at pH 4. Chromatographic separation and detection is performed by LC with diode array UV or fluorescence detection. The recoveries of 25 selected compounds were mostly between 80-110% and the detection limits were 0.4-2.4 microg/L for UV detection and for the fluorescence detectable compounds 0.4-140 ng/L. The method was successfully applied to groundwater samples from a wood preserving facility. Especially benzo(b)thiophene showed an increasing dominance downgradient of the source. Detection of metabolites, such as 1-hydroxyiso-, 2-hydroxyquinoline and 2-hydroxy-4-methylquinoline, 2-naphthoic acid, and 1-indanone, indicating in situ biodegradation, was confirmed by LC-ESI-MS analysis.  相似文献   

5.
A multiresidue solid phase extraction-gas chromatography (SPE-GC) method is developed for the analysis of 28 organochlorine (OCPs), organophosphorus (OPPs) and organonitrogen (ONPs) pesticides at ng l− 1 levels in washing water from olive processing. Pesticides are separated from the water matrix, containing estimable amounts of olive oil, by eluting them from a C18 SPE cartridge using dichloromethane. The target compounds are determined in the final extract by gas chromatography using thermionic specific (TSD) and electron capture (ECD) detection. Recoveries range from 79% to 129% in spiked washing water samples and detection limits are between 1 and 4 ng l− 1. The method was successfully applied to determine OCPs, OPPs and ONPs in 25 samples of water collected directly in the inlet and outlet of the washing devices of three olive mills at different locations in Jaén (Spain). The most frequently encountered pesticide residues were terbuthylazine, simazine and diuron. In some of the water samples coming from the inlet of the washing devices, terbuthylazine and diuron measured concentrations were above the concentration limits scheduled by law.  相似文献   

6.
Different solvent-free sample preparation techniques for the enrichment of volatile and semivolatile organic compounds from aqueous samples for subsequent gas chromatographic separation and detection are compared. The methods under study are purge-and-trap, membrane extraction with a sorbent interface in two different configurations, and thermal membrane desorption application. The study has been performed with polar as well as with non-polar compounds in respect to sampling yield, enrichment, repeatability and analysis cycle rate. All experiments have been performed with a mobile GC–MS system.  相似文献   

7.
The awareness of a need for an improved control of environmental contamination levels has led to the development of new hyphenated techniques for the determination of a wide variety of chemical species (e.g., organotins, methyl-mercury, alkyl-lead compounds etc.). These techniques generally involve many analytical steps such as extraction, derivatisation, separation and detection which have to be carried out in such a way that the speciation is not changed during the abalytical process. The need for evaluating the method's performance has led the BCR programme of the European Commission (now Standards, Measurements and Testing programme) to conduct series of interlaboratory studies during the last decade. These projects followed a step-by-step approach for the evaluation of different steps of the analytical methods used, e.g., simple solutions to test the detection, cleaned extract to evaluate the separation, spiked samples to test the extraction and natural samples to evaluate the whole analytical procedures. These collaborative projects allowed most of the sources of errors related to either a technique or a laboratory to be detected and removed. This paper gives an account of discussions of possible errors occurring in speciation analysis and presents examples of technical scrutiny of hyphenated techniques using chromatography as applied to the determination of tributyltin, methyl-mercury and trimethyllead.  相似文献   

8.
An analytical system composed of a purge-and-trap injection system coupled to gas chromatography with mass spectrometric detection (PTI-GC-MS) specific for the analysis of volatile chlorinated hydrocarbons (VCHCs) (chloroform; 1,1,1-trichloroethane; tetrachloromethane; 1,1,2-trichloroethylene; tetrachloroethylene) and trihalomethanes (THMs) (chloroform; bromodichloromethane; dibromochloromethane; bromoform) in water was optimised. Samples were purged and trapped in a cold trap (-100 degrees C) fed with liquid nitrogen (cryo-concentration). In order to make this method suitable also for only slightly contaminated waters, some modifications were made to PTI sample introduction, in order to avoid any air intake into the system. PTI, GC and MS conditions were optimised for halogenated compound analysis and limits of detection (LOD) were evaluated. The proposed method allows analysis of samples whose concentrations range from microg/L to ng/L. It is, therefore, applicable to drinking waters, in analyses required by law, and to slightly contaminated aqueous matrices, such as those found in remote areas, in environmental monitoring. Moreover, by changing cold trap temperature, even sparkling mineral waters can be analysed, thus avoiding CO2 interference during the cryo-concentration phase. Our method has been successfully used on real samples: tap water, mineral water and Antarctic snow.  相似文献   

9.
A new analytical method was developed for the simultaneous determination of estrogenic compounds of natural (estradiol, estriol, estrone) and synthetic origin, both steroidal (ethinylestradiol, mestranol) and non-steroidal (benzophenone, bisphenol-A, diethylstilbestrol, octylphenol, nonylphenol, nonylphenol monoethoxylate carboxylate), in environmental aqueous samples by high-performance liquid chromatography coupled with ion trap-mass spectrometry via electrospray interface (HPLC-ESI-IT-MS). Quantitative MS detection was performed in the negative mode for all compounds except mestranol and benzophenone, which were detected under positive ion conditions. Very low method detection limits (MDLs), between 0.1 and 2.6?ng/L, were achieved in coastal lagoon water samples, while the developed solid-phase-extraction (SPE) procedure permitted simultaneous recovery of all analytes from spiked water samples with yields >70% (7–11 RSD%), except estriol and benzophenone, which were recovered with 60% (9 RSD%) and 50% (11 RSD%) yields, respectively. The proposed method was applied to the analysis of Venice (Italy) lagoon waters, where average concentrations of selected compounds in the 2.8–33?ng/L concentration range were found.  相似文献   

10.
Poly(styrene-divinylbenzene) (PS-DVB) membrane extraction disks were used as sorbents for the on-line solid phase extraction of 13 phenols (nitro and chlorophenols) in river and tap waters. Determination was performed by liquid chromatography with electrochemical detection (LC-ED). An acetate buffer-acetonitrile-methanol mixture as mobile phase and amperometric detection at +1100 mV were used. High water volumes, up to 250 ml, can be preconcentrated without loss of phenols (recoveries between 80% and 100%) except for the more polar ones. Moreover, detection limits between 0.01 and 0.1 μg l−1 in tap water and between 0.1 and 1.0 μg−1 in river water were obtained. The method has been applied to the analysis of two river water samples.  相似文献   

11.
Summary The sensitive detection of volatile, methylated selenium and tellurium compounds based on capillary gas chromatography coupled to fluorine-induced chemiluminescence detection is described. The method requires no sample derivatization, and the detection limits for selenides and tellurides (low pg range) are the lowest reported to date. This technique can resolve and speciate complex mixtures of methylated tellurium, selenium, and sulfur gases and is useful for analysis of selenium and tellurium gases in environmental samples that also contain usually interfering reduced sulfur gases. Applications of the technique for analysis of bacterial and fungal headspace samples are presented.  相似文献   

12.
An analytical gas chromatography–mass spectrometry (GC–MS) method using negative ion chemical ionization (NICI) has been investigated for the determination of trace tributyltin (TBT) and triphenyltin (TPhT) compounds in sea water. TBT and TPhT were extracted from samples as chloride under the acidic condition of HCl. Doping of the GC system with a dilute HBr–methanolic solution resulted in direct detection of the chlorides of TBT, TPhT and tripentyltin (TPenT, internal standard). As the result of HBr doping, a sharp peak of the respective organotin bromides appeared: during GC analysis, halogen exchange from the chloride to the bromide occurred. NICI-MS was highly selective and sensitive for the detection of TBT, TPhT and TPenT bromides. In the selected ion monitoring mode of NICI-MS, the minimum detectable amounts defined as the signal equal to three times the standard deviation (3σ) of the baseline noise were 20 and 25 pg ml−1 for TBT and TPhT, respectively. These amounts are approximately 250–400 times better than those in electron impact mode. The combination of GC using an apolar capillary column doped with a dilute HBr–methanolic solution and NICI-MS made it possible to determine TBT and TPhT at less than the ng l−1 level in sea water.  相似文献   

13.
Gaca J  Wejnerowska G 《Talanta》2006,70(5):1044-1050
The simple, quick and effective methods for the analysis of epichlorohydrin (ECH) in water and sewage samples with the use of gas chromatography have been presented. From among all the methods developed, the procedures for monitoring drinking-water quality and the methods which allow the determination of epichlorohydrin in sewage samples have been selected.

The limits of ECH detection have been determined by direct aqueous injection (DAI) into the chromatographic column and an analysis with the application of a flame ionization detector (FID), a mass spectrometry detector (MS), an electron capture detector (ECD) and atomic emission detection (AED) detectors. The method allows the determination of ECH in water samples at the concentration level of 0.1 mg l−1. Moreover, the developed methods of water samples preparation for chromatographic analysis using the following extraction methods: headspace (HS), stripping with adsorption on solid phase, liquid–liquid extraction (LLE), solid phase extraction (SPE) and solid phase microextraction (SPME) have been evaluated. The limits of ECH detection for each procedure with the application of gas chromatography (GC) combined with various detectors have been determined and their statistical evaluation has been presented. The SPME method allowed us to determine ECH in water samples at the concentration levels of 1.0 ng l−1.

The results of studies on the choice of the selective methods allowing ECH analysis in sewage samples have been demonstrated. The applied SPME method was found to be a quick and effective technique to determine micro trace amounts of ECH in samples containing high amounts of various organic compounds.  相似文献   


14.
This work presents a rapid method for dichloromethane extraction of aroma compounds from brandies and aqueous-alcoholic wood extracts, in brandy-like ageing conditions, using ultrasound. The dichloromethane extracts were injected in split mode on a gas chromatographic (GC) system, separated on a DB-WAX capillary column and detected by flame ionisation. The method allowed satisfactory quantification of 37 volatile compounds in brandies (alcohols, esters, acids, furanics, aldehydes and phenols) and 16 volatile compounds in aqueous-alcoholic oak extracts. Linear responses were obtained (0.99-1.00). The repeatability and the detection and quantification limits were also evaluated. The analysis of spiked samples showed that matrix effects do not affect the method performance for the majority of the volatile compounds analysed.  相似文献   

15.
16.
研究了快速溶剂萃取-液相色谱/质谱联用技术测定血液中PFAAs的方法。血液样品经过冷冻干燥,利用加速溶剂萃取的方法,最后使用液相色谱-质谱仪分析检测PFAAs成分。方法的回收率为74.6%~128.8%,检出限为1.10~25.1 ng/L。通过对珠江三角洲地区人群血液样本的分析,发现∑9PFAAs的浓度为26.8~557 ng/g,平均值为176±90.1 ng/g。血液中PFAAs的主要成分以PFHxA和PFOS为主,分别占血液中PFAAs浓度的20.97%和66.98%。人群血液中最常见和浓度最高的PFAAs是PFOS,而PFOA浓度相对较低。  相似文献   

17.
A reliable and rapid speciation method for the simultaneous determination of butyl- and phenyltin species in biological samples has been developed. Three extraction procedures are compared: enzymatic hydrolysis and solubilization by ethanoic and hydrochloric acids. Derivatization is performed by the one-step ethylation/extraction procedure using the sodium tetraethylborate reagent directly in the aqueous phase in the presence of an isooctane layer. Analysis is performed using capillary gas chromatography coupled to flame photometric detection. The detection limits are in the range of a few ng(Sn)/g. Analysis of the environmental samples and the certified reference material demonstrates the accuracy of the analytical method.  相似文献   

18.
The presence of vinclozolin in the environment as far as the endocrine disruption effects in biota are concerned has raised interest in the environmental fate of this compound. In this respect, the present study attempts to investigate the feasibility of applying a novel quantitative method, liquid-phase microextraction (LPME), so as to determine this environmental andiandrogen in environmental samples such as water and sediment samples. The technique involved the use of a small amount (3 microL) of organic solvent impregnated in a hollow fiber membrane, which was attached to the needle of a conventional GC syringe. The extracted samples were analyzed by gas chromatography coupled with electron-capture detection. Experimental LPME conditions such as extraction solvent, stirring rate, content of NaCl and pH were tested. Once LPME was optimized, the performance of the proposed technique was evaluated for the determination of vinclozolin in different types of natural water samples. The recovery of spiked water samples was from 80 to 99%. The procedure was adequate for quantification of vinclozolin in waters at levels of 0.010 to 50 microg/L (r> 0.994) with a detection limit of 0.001 microg/L (S/N= 3). Natural sediment samples from the Aliakmonas River area (Macedonia, Greece) spiked with the target andiandrogen compound were liquid-liquid extracted and analyzed by the methodology developed in this work. No significant interferences from the samples matrix were noticed, indicating that the reported methodology is an innovative tactic for sample preparation in sediment analysis, with a considerable improvement in the achieved detection limits. The results demonstrated that apart from analyte enrichment, the proposed LPME procedure also serves as clean-up method and could be successfully performed to determine trace amounts of vinclozolin in water and sediment samples.  相似文献   

19.
A new analytical method has been developed for sample preconcentration and analysis of phenolic compounds in sherry wine using on-line solid-phase extraction(SPE)-HPLC-diode array detection. The samples of wine were injected and adsorbed onto polystyrene divinylbenzene cartridges; a robotic semiflexible system was used to automate the SPE stage. Chromatographic separation was carried out in a Symmetry C18 steel cartridge, with a two-step elution gradient. Peaks were identified by comparing their UV spectra with the library of spectra compiled by the authors.  相似文献   

20.
Profiling methods are needed that separate and detect all the phenolic compounds in a single extract of a food material. These methods must be comprehensive, rapid, and rich in spectral information. Fourteen methods that meet, or have the potential to meet, these criteria have been selected from the recent literature for review. In general, the methods employ a single aqueous methanol extraction, separation on a reversed-phase C column, and detection by UV/vis spectroscopy and mass spectrometry. The variations in extraction, separation, and detection are discussed. An increasingly important aspect of these methods is the archiving of data to permit cross-comparison of samples and standards and retrospective analysis. This review shows that the necessary technology is available to achieve the desired analytical goals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏